JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026020364520Transition Panel · corrodedAFT CARGO RT SIDEPLATE (TRANSITION PANEL) IS CORRODED MULTIPLE SPOTS STA 727-787. GROUNDED - YES. REMOVED CORROSION, DUE TO 100% MAT LASS, FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 53-00-53-1A-2, FABRICATED, LOCATED, DRILLED & INSTALLED NEW TRANSITION PANELSDR AALA202602053744Baffle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FORWARD CARGO COMPARTMENT BAFFLE BETWEEN BS 500H AND 500I AT S26L. REPLACED BAFFLE PER AARD 51-00-05-1.SDR SWAA2026030966984Support Angle · crackedCRACKED SUPPORT ANGLE, BS 867, S2 - 3R. REPLACED THE SUPPORT ANGLE AND FASTENERS IAW SRM 51-40-02-0G-0 AND DWG 146A7901, SHEET 66, REV A.SDR CALA2026030914400Floor Support · crackedMAIN CABIN FLOOR SUPPORT INTERCOSTAL BETWEEN STA 312 AND 328 IS CRACKED ON THE FLOOR UPPER ATTACH FLANGE AT APPROX LBL45. LOCATED AND DRILLED INTERCOSTAL IAW SRM 51-40-05. REMOVED AND REPLACED CRACKED FLOOR SUPPORT AT BS 312 AND STA 328 IAW DWG 141A5400 IAW SSDR SWAA2026030566956Support Bracket · crackedCRACK SUPPORT BRACKET LOCATED BS 540 AT LEVEL LBL 6 AT LT & RT AIR CONDITIONING BAYS. REPLACED SUPPORT BRACKET LOCATED BS 540 AT LEVEL LBL 6 AT LT/RT AIR CONDITIONING BAYS IAW SRM 51-10-02, ITEM 9, AND DWG 212A1101, SHEET 11, REV -.SDR SWAA2026030566957Support Bracket · crackedCRACKED SUPPORT BRACKET, BS 540, RBL 6 IN THE LT & RT AIR CONDITIONING BAYS. REPLACED THE SUPPORT BRACKET IAW SRM 51-10-02-0G, & DWG 212A1101, SHEET 11, REV -,SDR SWIA2026030475409Floor Support · corrodedRIGHT FLOOR SUPPORT FR 87, Y+10 CORRODED. REMOVED AND REPLACED THE FLOOR SUPPORT FR 85-89 Y+10.5" IAW SRM 51-40-08. NO FURTHER ACTION REQUIRED.SDR AALA202602186613Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23R BTW FR69 AND FR70 AT AFT GALLEY AREA L= 1.008 IN. MAINTENANCE REPLACED SHEAR PLATE, AND FASTENERS LOC. ON STR 23R BTW FR69 AND FR70 AT AFT GALLEY AREA I.A.W. A319 SRM 51-42-11-801, A319 SRM 51-72-11-911-SDR AALA202602181116Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23L BTW FR69 AND FR70 AT AFT GALLEY AREA L=1.025 IN. MAINTENANCE REPLACED SHEAR PLATE, AND FASTENERS LOC. ON STR 23R BTW FR69 AND FR70 AT AFT GALLEY AREA I.A.W. A319 SRM 51-42-11-801, A319 SRM 51-72-11-911-0SDR 2026FA0000106Bracket · crackedFLAP HANDLE FORWARD SUPPORT BRACKET FOUND CRACKED. NOTED AREA OF STRESS/CRACK A LACK OF RADIUS. REPLACED WITH FACTORY NEW BRACKET.SDR DALA2026021100971Strap · corrodedFUSELAGE UPPER LOBE INTERIOR STRUCTURE FOUND STRAP CORROSION AT STA 903 S-18R. REPAIR IAW ER/A 631779-14. (1431906)SDR YENA2026020400127Structure · crackedDURING HEAVY MAINTENANCE: CRACK FLOOR STRUCTURE UPPER SECTION CONNECTION LOC FR 66 AT LEVEL STR 23KH AT AFT GALLEY AREA (1EA); REMOVED AND REPLACED FLOOR STRUCTURE UPPER SECTION CONNECTION LOC FR 66 AT LEVEL STR 23LH SIDE AT AFT GALLEY AREA (1EA)IAW A320 SRM 5SDR YENA2026020400120Web · corrodedDURING HEAVY MAINTENANCE: CORROSION FLOOR STRUCTURE WEB LOC. BTW FR69/70 AT LEVEL STR23L AT AFT GALLEY AREA (1 EA) (CPCP FINDING); REF AEROMAN NR 2025-682631 WO 2025 413/1 REMOVED AND REPLACED FLOOR STRUCTURE WEB LOC BTW FR69 TO FR70 AT LEVEL STR23L AFT GALLEYSDR CALA2026020413547Web · corrodedMAIN CABIN AFT WET AREA WEB HAS CORROSION ON UPPER SURFACE BETWEEN BS 986.5 AND BETWEEN LBL-24 & LBL-45. R & R NEW WET SUPPORT IAW DWG 147A5116, REV.A, SRM 51-40-02.SDR SWAA2026030966764Web · crackedCRACKED WEB, BS 312 - 328, RBL 33. REPLACED THE WEB IAW SRM 51-10-02, ITEM 9, & DWG 141A5400, REV -, SHEET 39.SDR JJBA20260220072Floor Support · crackedRIGHT OMEGA BEAM AT FR 61, DAMAGE FOUND AROUND 1EA AFT FLOORBOARD ATTACHMENT HOLE. REPAIRED CRACK AT OMEGA BEAM AT FR 61 AROUND AFT FLOORBOARD ATTACHMENT HOLE.SDR JJBA20260220067Support · corrodedAFT WET AREA 1EA FRAME SUPPORT AND FASTENER AT FR 60, STR 20L, HAS CORROSION, REMOVED AND REPLACED AFT WET AREA 1 EA FROM SUPPORT AND FASTENERS AT FR60 STR 20LSDR JJBA20260220066Floor Support · corrodedLH OMEGA BEAM AT FRAME 49 REQUIRES DOUBLER REPAIR. REMOVED CORROSION AND REPAIRED LH OMEGA BEAM AT FR 49SDR JJBA20260220065Floor Support · corrodedL/H OMEGA BEAM AT FR 28.11 REQUIRES REPAIR DOUBLER. REMOVED CORROSION AND REPAIRED LH OMEGA BEAM LAND FRAME 23-28SDR JJBA20260220064Floor Support · damagedL/H OMEGA BEAM AT FR 28.3 REQUIRES REPAIR DOUBLER. REMOVED CORROSION AND REPAIRED LH OMEGA BEAM LAND FRAME 23-28.SDR JJBA20260220063Floor Support · damagedCENTER OMEGA BEAM AT FR 24.6 REQUIRES REPAIR DOUBLER. REMOVED CORROSION AND REPAIRED CENTER OMEGA BEAM AT FR 24.6SDR DALA2026020500841Plate · corrodedCORROSION ON SIDE PLATE RT BTW BS 500 TO 500A, 500A TO 500B, 500B TO 500C, 500D TO 500E, 500E TO 500F, 500F TO 500G, 500G TO 500H, 500H TO 500I, 500I TO 500J, 500J TO 500K, 500K TO 500L AT FWD CARGO COMPARTMENT. SIDE PLATES REPLACED PER B737-900 SRM 5SDR AALA202602053099Support Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR STRUCTURE SUPPORT PLATE LOCATED BETWEEN STA 739 TO STA 755 .5 RIGHT HAND SIDE AT FORWARD CARGO COMPARTMENT. REPLACED SUPPORT PLATE PER SRM 51-40-02-0G.SDR DALA2026020200748Floor Support · corrodedCORRODED FLOOR SUPPORT -Y1162.5, BTWN FR 68 TO FR 69 AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND SRM 51-42-11, AND DWG D53472189, AND DWG D53472780. MEASUREMENT OF CORROSION: L= 0.850 INCH W= 0.668 INCH D= 0.036 INCH.SDR DALA2026020200741Fitting · corrodedCORROSION CENTER FITTING LOCATED BTW FR 66 TO FR 68 RH SIDE LOWER SILL AT AFT GALLEY AREA (SSI 534147). REPLACED CENTER FITTING LOC. BTW FR 66 TO FR 68 RH SIDE LOWER SILL AT AFT GALLEY AREA IAW SRM 51-42-11, A320 SRM51-72- 11, DWG D53480505, ISSUE: FE. MEASSDR VNAA20260329020Fitting · corrodedCORROSION FLOOR FITTING ON ACCESS 307 (2EAS) ON GALLEY 3. FLOOR FITTING ON ACCESS 307 (2EAS) ON GALLEY 3 WERE REPLACED PER CMM 25-33-13SDR SWAA2026030966425Floor Support · corrodedCORRODED FLOOR SUPPORT, BS 947.5 - 967, LBL 24, WL 208.1. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 147A5650, SHEET 5, REV E.SDR SWAA2026030966426Angle · corrodedCORRODED ANGLE, FLOOR STRUCTURE BS 992.8, RBL 31, WL 208.1. REPLACED THE ANGLE IAW SRM 51-40-02, AND DWG 147A5700, SHEET 123, REV A.SDR SWAA2026030566543Angle · crackedCRACKED ANGLE, BS 400, STRINGER 26L. REPLACED THE ANGLE IAW SRM 51-40-02, & DWG 143A7505, SHEET 137, REV -. THE ANGLE WAS REPLACED DUE TO NO ALLOWABLE DAMAGE LIMITS IN SRM 53-00-53-1A-2.SDR SWAA2026030566537Angle · crackedCRACKED ANGLE, BS 500G, STRINGER 26L FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-40-02, & DWG 143A7505, SHEET 138, REV -.SDR SWAA2026030566548Angle · crackedCRACKED ANGLE, BS 500H, STRINGER 26R, FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-40-02, & DWG 143A7505, SHEET 139, REV -.SDR SWAA2026030566544Angle · crackedCRACKED ANGLE, BS 500G, STRINGER 26L, REPLACED THE ANGLE IAW SRM 51-40-02, & DWG 143A7505, SHEET 138, REV -.SDR SWAA2026030566545Angle · crackedCRACKED ANGLE, BS 500G, STRINGER 26R. REPLACED THE ANGLE IAW SRM 51-40-02, AND DWG 143A7505, SHEET 138, REV -.SDR SWAA2026030566546Angle · crackedCRACKED ANGLE, BS 500H, STRINGER 26L. REPLACED THE ANGLE IAW SRM 51-40-02, & DWG 143A7505, SHEET 139, REV -.SDR SWAA2026030566549Support Bracket · crackedCRACKED SUPPORT BRACKET, BS 727. REPLACED THE SUPPORT BRACKET IAW SRM 51-10-02-0G-0, ITEM 9, SRM 51-40-02-0G-0, AND DWG 144A2600, SHEET 1084, REV-.SDR SWAA2026030566538Angle · crackedCRACKED ANGLE, BS 500H, STRINGER 26R. REPLACED THE ANGLE, IAW FASTENERS IAW SRM 51-40-02-0G, SRM-51-10-02-0G-0, ITEM 9, & DWG 143A7505, SHEET 138, REV-.SDR SWAA2026030566547Angle · crackedCRACKED ANGLE, BS 500H, STRINGER 26L. REPLACED THE ANGLE & FASTENERS IAW SRM 51-40-02, & DWG 143A7505, SHEET 139, REV -.SDR SWAA2026030566540Gusset · crackedCRACKED GUSSET ANGLE, BS 500I, STRINGER 19R. REPLACED THE GUSSET ANGLE IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, AND DWG 143A7902, SHEET 256, REV B.SDR SWAA2026030566539Gusset · crackedCRACKED GUSSET ANGLE, BS 500I, STRINGER 21R, FWD CARGO BAY. REPLACED THE GUSSET ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG 143A7902, SHEET 257, REV B.SDR HNAA2026030400183Floor Support · corroded00437 MID FLOOR GUSSET FROM FR 45 TO FR 47 HAS CORROSION. REMOVED AND REPLACED CENTER OMEGA BEAM FROM FR 46 - FR 53 (GUSSET P/N 145-30634-011) PER EMB 145 SRM 51-40-02-PR.SDR HNAA2026030400182Floor Support · corrodedMID FLOOR GUSSET FROM FR 38 TO FR 45 HAS CORROSION,. REMOVED AND REPLACED WITH NEW FROM STOCK MID FLOOR GUSSET FROM FR 38 TO FR 45 IAW EMB145 SRM 51-40-02-PR. REMOVED AND REPLACED WITH NEW FROM STOCK MID FLOOR GUSSET FROM FR 38 TO FR 45 IAW EMB 145 SRM 51-40SDR HNAA2026030400181Floor Support · corrodedFLOOR SILL FROM FR 35 TO FR 39, LH, HAS CORROSION. REMOVED AND REPLACED FLOOR SILL FROM FR 35 TO FR 39 LH. REF EMB145 SRM 51-40-02.SDR REXA2026021300056Web · corrodedRIGHT BS 280 LOWER WEB CORRODED AT RBL 12. ON FURTHER INVESTIGATION, FOUND RT LOWER WEB TO BE HEAVILY CORRODED BEYOND REPAIRABLE DAMAGE LIMITS IAW SRM 53-11-10-201-003-A01. RT LOWER WEB FABRICATED, LOCATED, DRILLED, AND TRIMMED TO FIT IAW SRM 53-11-10-201-00SDR SWAA2026021266482Support Angle · crackedBS 867, LBL 12, WASTE COMPARTMENT PANEL, SUPPORT ANGLE CRACKED. R & R THE SUPPORT ANGLE IAW SRM 51-40-02. INSPECTED IAW SRM 51-40-02-0G-0-D00069.SDR AALA202602068964Shear Panel · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN SHEET-SHEAR BETWEEN FR 68 AND FR 69 AT S23L. REPLACED SHEET SHEAR PER SRM 51-72-11-911-001.SDR AALA202604068454Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23R BTW FR69 AND FR70 AT AFT GALLEY AREA. MEASURE L: 1.098 INCH.SDR AALA202603238053Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR SWAA2026030966090Intercostal · crackedCRACKED INTERCOSTAL, BS 277 - 294.5, BL 0. REPLACED THE INTERCOSTAL IAW SRM 51-10-02, ITEM 9, & DWG 141A5400, SHEET 20, REV-.SDR SWAA2026030966259Support Angle · crackedCRACKED SUPPORT ANGLE, BS 727, RBL 24.5 AND LBL 24.5, WL 156. REPLACED THE SUPPORT ANGLE IAW SRM 51-10-02, ITEM 9.SDR SWIA2026013075421Angle · brokenRBL9 ANGLE AT FS 280.00 BROKEN. REPAIRED RBL9 ANGLE AT FS 280 IAW REO 601R-53-11-4048
Back to JASC 5320