JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2025092361331Floor Support · crackedINTERCOSTAL BETWEEN FRAME STATION 312 AND 328 RBL 40 CRACKED. GROUNDED - YES. REMOVED INTERCOSTAL BETWEEN FRAME STATION 312 AND 320 RBL 40 IAW B737-700 SRM 51-40-02-0G-0 INSTALLED NEW INTERCOSTAL N.P 141A5410U140 TAG AS34740 BETWEEN FRAME STATION 312 AND 328 RSDR IPXA2025100100289Floor Support · crackedMAIN DECK FLOOR STRUCTURE AT FRAME 79, -Y1580.5 ANGLE CRACKED. REMOVED CRACKED ANGLE. IAW SRM 51-40-21-001. INSTALLED ANGLE IAW SRM 51-40-21-001.SDR IPXA2025100100260Floor Support · crackedMAIN DECK FLOOR STRUCTURE AT FRAME 79 AT Y1580.5 ANGLE CRACKED. REMOVED CRACKED ANGLE IAW SRM 51-40-21-001. INSTALLED ANGLE IAW SRM 51-40-21-001.SDR DALA2025092907033Threshold Web · corroded(LOG 1214002) AFT CARGO DOORWAY THRESHOLD WEB CORRODED. EVALUATED & REPLACED THE AFT CARGO LOWER MAIN SILL WEB IAW B737- 900 SRM 53-60-15-1-A1 & SRM 51-40-02-0G.SDR CALA2025092609293Bracket · crackedRIGHT FWD CARGO COMPARTMENT AT AFT AIR CONDITIONING DISTRIBUTION BAY AT BS 500I, STR 19R HAS BRACKET CRACKED. REMOVED AND REPLACED RIGHT FWD CARGO COMPARTMENT GUSSET AT AFT AIR CONDITIONING DISTRIBUTION BAY AT BS 500I, STR 19-R IAW SRM 51-40-02-0G-0 AND DWG SDR DALA2025092406971Fitting · corrodedCORROSION OUT OF LIMITS ON FITTINGS (2 EAS) LBL 24 AND LBL 46 AT FLOOR STRUCTURE W4 WHERE ORIGINAL THICKNESS= 0.100" AND ORIGINAL THICKNESS= 0.520" , LBL 46 REMAINING THICKNESS =0.068" AND REMAINING THICKNESS =0.494"; LBL 24 REMAINING THICKNESS = 0.073" REMAINSDR DALA2025092406965Floor Support · corrodedCABIN FLOOR SUPPORT FR74 TO FR75 Y= -794 & Y= -1137 CORRODED. REPAIRED PER ERA 629147-14. (1213407)SDR AALA202509247576Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR SUPPORT BETWEEN FR 68 AND FR 69 AT+Y1162.5. REPLACED FLOOR SUPPORT PER SRM 51-72-11.SDR F3LA202509230296Floor Support · corrodedAIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INSPECTION FOUND CABIN FLOOR SUPPORT Y-254 AT FR.20 CORRODED. PERMANENT REPAIR WAS PERFORMED IN FLOOR SUPPORT Y-254 AT FR.20 AS PER EA N2-53R-39779 REV ORIG.SDR F3LA202509230295Floor Support · corrodedAIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INSPECTION FOUND CABIN FLOOR SUPPORT Y254 AT FR.16-18 CORRODED. REQUIRES REPLACEMENT AS PER SRM 51-72-11 REV 45.
CORRECTION ACTION: FLOOR SUPPORT Y254 AT FR.16-18 REPLACED AS PER SRM 51-72-11 SDR F3LA202509230294Shear Plate · crackedAIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INSPECTION OF THE AFT CABIN FLOOR STRUCTURE A CRACK WAS FOUND ON LH SHEAR PLATE BETWEEN FR69 TO FR 70. REPLACEMENT IS REQUIRED. PERFORMED REPLACEMENT OF LH SHEAR PLATE I.A.W. SRM-51-72-11 REVSDR SWI2025F01674Intercostal · corrodedINTERCOSTAL AT STGR 21LH BETWEEN FS333.00 AND FS349.00 HAS CORROSION ON UPPER WEB. (MARKED) (C-CHECK RO 11/30/2025)REPLACED INTERCOSTAL AT STGR 21 LH BETWEEN FS333.00 AND FS349.00 REF. DWG# SH670-31810 REV AE AND CRJ700 SRM 51-42-06-001-001-A01. C/W 51-900-SDR VNAA202511260004Intercostal · corrodedCORROSION ON INTERCOSTAL ATTACHED TO STGR 20RH BTW FS 310.00 AND FS 319.00 AT MAIN AVIONICS COMPARTMENT. INTERCOSTAL ATTACHED TO STGR 20RH BTW FS 310.00 AND FS 319.00 AT MAIN AVIONICS COMPARTMENT WAS EVALUATED DUE EXCESSIVE DAMAGE PER CRJ-700 SRM 53-21-23-10SDR SWAA2025110317055Shield · corrodedCORROSION ON AFT SHIELD BS 500-500A, S27R WL 156. REMOVED AND REPLACED FCB AFT SHIELD IAW SRM 51-40-02-0G-0 AND DWG 143A0080 REV -.SDR AALA202510308393Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING BETWEEN FR 15 AND FR 16 RIGHT AND DOOR STOP 7. REPLACED INTERCOSTAL FITTING SRM 51-42-11.SDR AALA202510077496Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL LOCATED FROM BS 328 TO BS 344 AT LBL 45. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202509230614Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR SUPPORT BETWEEN FR 68 AND FR 70 AT +Y160.5. REPLACED FLOOR SUPPORT PER SRM 51-72-11.SDR AALA202509238198Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR SUPPORT BETWEEN FR 68 AND FR 70 AT -Y160.5. REPLACED FLOOR SUPPORT PER SRM 51-72-11.SDR DALA2025092306936Floor Support · corrodedCORROSION ON FLOOR SUPPORTS BTW STA 312 TO 344 LBL12 AT CPAX. FLOOR SUPPORTS BTW STA 312 TO 344 LBL12 AT CPAX WERE REPLACED AND INSTALLED PER B737-800 SRM 51-40-02-0G.SDR FDEA202509221760Fitting · not reportedDOORS - CARGO DOOR/HYD SYS - DETAILED VISUAL INSPECTION OF THE MAIN DECK CARGO DOOR (MDCD) ACTUATOR BEARING FITTINGS AT FRAME 23 AND 24 - AOT A52W016-24 COMPLIED WITH EO: 6-5230-E0378588 B P5. TITLE: DOORS - CARGO DOOR/HYD SYS - DETAILED VISUAL INSPECTION SDR REXA2026052600625Support Angle · crackedCRACK AT LOWER SUPPORT ANGLE OF EXTERNAL SERVICE PANEL. CRACKED LOWER SUPPORT ANGLE OF EXTERNAL SERVICE PANEL WAS REPLACED IAW SRM 51-42-06-001-001-A01SDR SWI2025F01670Support Angle · corrodedSERVICE DOOR SURROUND HAS CORROSION ON 3EA STEP PLATE SUPPORT ANGLES. (MARKED) (C-CHECK RO 11/30/2025)REMOVED & REPLACED 03 EA. STEP PLATE SUPPORT ANGLES PN: SH670-31982-1 AT SERVICE DOOR SURROUND REF CRJ700 SRM 51-42-06-001-001-A01.COMPLIED WITH 51-900-1002SDR AALA202511073567Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION INTERNAL STRUCTURE LOWER CORNER FITTING FR66 RH SIDE IN PASSENGER CABIN MEASURE CORROSION ARE L=1.43 INCH W=1.22 INCH D=0.002 INCH. MAINTENANCE REPLACED CORNER FITTING LOC ON INTERNAL STRUCTURE LOWER FR66 RH AT LEVEL STRSDR FDEA202509211943Profile · corrodedBULK CGO COMPT FLOOR BEAM PROFILE UPPER SKIN CORRODED AT FR66 - FR67, Y-805 POSITION. INSTALLED THE FABRICATION PROFILE WITH FASTENERS AT BULK CARGO COMPARTMENT FR66 - FR67, Y-805 IAW SRM 53-17-15-001, CONFIG-3, PAGE.80 AND 90, FIG.8(SHEET-1) & 51-41-21-001,SDR FDEA202509211942Profile · corrodedBULK CARGO COMPT FLOORBEAM PROFILE UPPER SKIN CORRODED AT FR67 - FR68, Y46.7 POSITION. INSTALLED FABRICATION PROFILE WITH FASTENERS AT BULK CARGO COMPARTMENT FR67 - FR68, Y46.7 IAW SRM 53-17-15-001, CONFIG-3, PAGE.80 & 90, FIG.8(SHEET-1) & 51-41-21-001, PARASDR FDEA202509211939Profile · corrodedBULK CARGO COMPT FLOORBEAM PROFILE UPPER SKIN CORRODED AT FR67 - 68, Y625 POSITION. INSTALLED THE FABRICATION PROFILE WITH FASTENERS AT BULK CARGO COMPARTMENT FR 67 - 68, Y625 IAW SRM 53-17-15-001, CONFIG-3, PAGE.82 AND 90, FIG.8 (SHEET-1), & 51-41-21-001, PARSDR ASAA2025092161462Plate · corrodedAFT CARGO L/H SIDEPLATE HAS MULTIPLE AREAS OF CORROSION BETWEEN STA 727+4 TO STA 767. GROUNDED - YES. REMOVED CORR, FOUND TO BE OUT OF LIMITS REPAIRED SIDEPLATE IAW B737-700 SRM 53-00-53-2R-5W= 1.25 O= .040 R= .000 L= 3.75 D= .040.SDR ASAA2025092161329Plate · corrodedFWD CARGO RT SIDEPLATE HAS MULTIPLE AREAS OF CORROSION BETWEEN STA 500 AND STA 500D. GROUNDED - YES. REMOVED CORROSION, FOUND TO BE OUT OF LIMTIS IAW B737-700 SRM 53-00-53-1A-2. REPAIRED SIDE PLATE IAW B737-700 SRM 53-30-53-01-2 AND SRM 51-40-02-0G-0 W= 1.25 OSDR SWAA2025092616871Scuff Plate · corrodedCORROSION ON CORNER PLATE (2EA) OF THRESHOLD SCUFF PLATE AT AFT CARGO COMPARTMENT. REPLACED CORNER PLATE (2EA) OF THRESHOLD SCUFF PLATE AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02; ITEM 9 AND DWG 453A2611; SHEET 1; REV C.SDR DALA2025092206915Floor Support · damagedINBOARD FLOOR PANEL ATTACH HOLES DAMAGED ON LONGITUDINAL - BEAM F5347821420900 AT Y1137.1 BETWEEN FR75. COMPLIED WITH ERA 629147-14 REV ORIG. (1209577)SDR DALA2025092206912Floor Support · damagedOUTBOARD FLOOR PANEL ATTACH HOLES DAMAGED ON LONGITUDINAL - BEAM F5347821220700 AT Y794.3 BETWEEN FR75. COMPLIED WITH ERA 629147-14 REV ORIG. (1209576)SDR DALA2025092206899Support · corrodedCORROSION LOWER SILL LOC. AT LEVEL FR 68 RH AT AFT GALLEY AREA. PERFORMED PERMANENT REPAIR (ANGLE AND SHIM) LOC. AT LEVEL FR 68 RH AT AFT GALLEY AREA AS PER A321 SRM 53-41-14-300-001. (LP 1210588)SDR SWAA2025110316500Scuff Plate · crackedAFT CARGO DOOR FWD CORNER SCUFF PLATE IS CRACKED. RECEIVED NEW AFT CARGO DOOR FWD CORNER SCUFF PLATE ITEM 146A8341-07. IT WILL BE INSTALL ON TASK CARD TTG8Q0157507.SDR SWAA2025110316512Fitting · crackedCRACKED FITTING, BS 559+8, LBL 6, WL 148.5. RECEIVED NEW FITTING. REMOVED AND REPLACED THE FITTING IAW SRM 51-40-02-0G-0, AND AIPC 53-12-11-25 FIG 2.SDR R61A2025101700437Strap · corrodedDURING C-CHECK CF III FR77 STR27R FOUND CORRODED WTB RETAINER STRAP. REMOVED AND REPLACED WTB RETAINER STRAP IAW SRM 51-42-02 AND 51-43-02SDR ASAA2025092061455Baffle · corrodedTHE BAFFLE BETWEEN STA 500G-500H HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED BAFFLE IAW DWG 143A7505 REV- NO SRM LIMITS.SDR ASAA2025092061453Baffle · corrodedTHE BAFFLE BETWEEN STA 500F-500G HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED BAFFLE BETWEEN STA 500F-500G PER BAC DWG 143A7505 REV. B. NO SRM LIMITS.SDR ASAA2025092061451Baffle · corrodedTHE BAFFLE BETWEEN STA 500H-500I HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED BAFFLE IAW DWG 143A7505 REV B NO SRM LIMITS.SDR CALA2025100909831Channel · corrodedAFT CARGO BAY, BS 1300 RT SIDE BRACKET SUPPORT ATTACHED IN THE FRAME FOUND WITH CORROSION. REMOVED AND REPLACED ONE CHANNEL IAW SRM 51-40-02-0G -1, VIA T25/1832218.SDR CALA2025100909830Channel · crackedTWO CRACKS FOUND ON LT WHEEL WELL DOOR SEAL SUPPORT CHANNEL BS 1060, LBL 50. REMOVED AND REPLACED 149N7550-95 VIA T25/831393 IAW SRM 51-40-02 -0G-1 RESTORED SURFACE PROTECTION IAW SRM 51-20-01-0G AND AMM 5 1-21-15.SDR IPXA2025092555955Bracket · crackedAFT CARGO-AFT REAR BULKHEAD FR54 1EA ANGLE CRACKED AT -Y1456 I/B SIDE-109-23 VWV 91195430.REMOVED AFT CARGO-AFT REAR BULKHEAD FR54 1EA ANGLE AT Y0, IAW A300-600 SRM 51-40-21. FABRICATED NEW ANGLE, IAW UPS GMM 09-08 AND A300-600F SRM 53-15-18.INSTALLED NEW ANGLSDR IPXA2025092556039Bracket · crackedAFT CARGO-AFT REAR BULKHEAD FR54 1EA ANGLE CRACKED AT Y1456 O/B SIDE-109-22 VWV 91195430. REMOVED AFT CARGO-AFT REAR BULKHEAD FR54 1EA ANGLE IAW A300-600 SRM 51-40-21.FABRICATED NEW ANGLE, IAW UPS GMM 09-08 AND A300-600F SRM 53-15-18.INSTALLED NEW ANGLE IAW A3SDR IPXA2025092556055Bracket · crackedAFT CARGO-AFT REAR BULKHEAD FR54 1EA ANGLE CRACKED AT -Y1456 O/B SIDE-109-24 VWV 91195430.REMOVED AFT CARGO-AFT REAR BULKHEAD FR54 1EA ANGLE AT -Y1456 O/B SIDE, IAW A300-600 SRM 51-40-21.FABRICATED NEW ANGLE IAW UPS GMM 09-08 PARAGRAPH 09.08.01.04 AND A300-600SDR DALA2025092907036Transition Panel · corroded(LOG 1216177) FWD CARGO RH TRANSITION PANEL CORRODED AROUND NUTPLATES STA 500-500L. REMOVED AND REPLACED FWD CARGO R/H TRANSITION PANEL FROM STA 500 TO STA 500L IAW B737-900 SRM 53-00-53, 51-10-02.SDR CALA2025092609291Floor Support · corrodedAFT CABIN FLOOR RT CREASE BEAM CORRODEED BETWEEN BS 1340 - 1405 UNDER FLOORBOARD 252FF AND 252GF. CORRODED CABIN FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-40-02 AND SRM 51-40-05.SDR SWAA2025092316611Panel · crackedFWD CARGO PANEL 122AW HAS MULTIPLE CRACKS WITHIN 2 INCHES OF THE EDGE. REPAIRED CARGO PANEL 122AW IAW EA# M-21-125-00669.SDR SWAA2025092316610Panel · cracked141FW HAS MULTIPLE CRACKS WITHIN 2 INCHES OF THE EDGE. REMOVED AFT CARGO PANEL 141FW IAW AMM 25-52-10. FOUND MULTIPLE BROKEN NUT PLATES. REMOVED AND REPLACED AFTER CARGO PANEL 141FW IN REF TO AMM 255-52-06.SDR SWAA2025092316469Panel · crackedAFT CARGO PANEL 142FW HAS 2 CRACKS COMING FROM CAP STRIP AREA. PATCHED CRACKS PER EA M-21-125-00669.SDR REXA2026052800858Stringer · corrodedIN REFERENCE TO NRC 00604: CORROSION ON STRINGER 19RH, 20RH AND 21RH IN STA. FS= 437 TO FS= 453 AT MAIN AVIONICS COMPARTMENT. (E/E) SUMMARY OF NRC 677 CORROSION ON STRINGER 20RH AND 21RH IN STA. FS= 437 TO FS= 453 AT MAIN AVIONICS COMPARTMENT WERE EVALUATED OSDR REXA2026052800853Bracket · corrodedCORROSION ON WEB FLOOR PROTECTOR THEIR ANGLES (8 EAS) AT SERVICE DOOR SURROUND STRUCTURE BTW FS 319.70 TO FS 349.00. CORROSION ON WEB FLOOR PROTECTOR THEIR ANGLES (8 EAS) AT SERVICE DOOR SURROUND STRUCTURE BTW FS 319.70 TO FS 349.00. WAS REMOVED PER CRJ900 SR
Back to JASC 5320