JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20250427003Floor Support · corrodedAFT GALLEY AREA LH CTR FLOOR BEAM UPPER SHEET BETWEEN FR 85-86 IS CORRODED. (LEVEL 2 CORROSION) (MAJOR REPAIR) REMOVED AND REPLACED AFT GALLEY AREA LH CENTER FLOOR BEAM SHEET BETWEEN FRAMES 85-86 IAW EMB 175 SRM 51-40-08SDR SIMA20250427001Gusset · corrodedAFT GALLEY AREA RH OUTBD SPLICE AT FR 90 IS CORRODED. (LEVEL 2 CORROSION). REMOVED AND REPLACED AFT GALLEY AREA RH OUTBD SPLICE AT FR90 IAW EMB 175 SRM 51-40-08SDR SIMA20250427002Floor Support · corrodedSSI 53-23-005 AFT GALLEY AREA RH CTR FLOOR BEAM UPPER SHEET BETWEEN FR 85-86 IS CORRODED. (LEVEL 2 CORROSION). REMOVED AND REPLACED AFT GALLEY AREA RH CTR FLOOR BEAM UPPER SHEET BETWEEN FR 85-86 IAW EMB 175 SRM 51-40-08SDR DALA2025050203392Support Channel · corroded(LOG 0936408) CORROSION CHANNEL SUPPORT LOCATED BS767 PLUS 5 INCHES AND LBL 8.10 AT AFT CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON CHANNEL SUPPORT LOCATED BS767 PLUS 5 INCHES AND LBL 8.10 AT AFT CARGO AS PER B737-800 SRM 53-00-53-2R PROCEDURE 2 REPAIR 2.SDR DALA2025050203389Support Channel · corroded(LOG 0936423) CORROSION CHANNEL SUPPORT LOCATED BS767 PLUS 5 INCHES AND RBL 3 AT AFT CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON CHANNEL SUPPORT CHANNEL SUPPORT LOCATED BS767 PLUS 5 INCHES AND RBL 3 AT AFT CARGO COMPARTMENT ASPER B737-800 SRM 53-00-53-2R.SDR DALA2025050103349Floor Support · corrodedSHIP 3142 DISC: CORROSION LOWER SILL LOCATED AT FR 68 LH SIDE AT AFT GALLEY AREA (SSI 534147 ). C/A: PERFORMED REPAIR LOWER SILL LOC ON FR68 LH SIDE AT AFT GALLEY AREA AS PER A319 SRM 53-41-14-300-001 STEP 2, FIGURE 001, SHEET 4,PRINCIPLE 7 AND A319 SRM 51-42-SDR DALA2025043003330Door Sill · corroded***CORROSION*** ON FWD CARGO COMPARTMENT DOOR LOWER SILL FASTENER HOLES, BETWEEN FR-24 AND FR-29. WORK ACCOMPLISHED ON ER/A 625727-14 REV-ORIGINAL SECTION 1-2-3. (LP# 0936112)SDR REXA2025042800514Floorbeam · corrodedFS280 LH FLOOR CROSSBEAM IS CORRODED. REMOVED FS280 L/H FLOOR CROSSBEAM, IAW CRJ-700 SRM 51-42-41-001-001-A01, 51-42-06-001-001-A01, 51-42-13-001-001-A01. INSTALLED FS 280.00 L/H FLOOR CROSSBEAM, P/N: CC670-34094JP-1S, IAW GREO 670-53-11-579, REV. B, DATE 20SDR SWI2025F01112Floor Support · corrodedINTERNAL STRUCTURE, FLOOR BEAM RBL9 HAS CORROSION AND SCRATCHES BETWEEN FS1015 TO FS1088, HN00238047 (C-CHECK RO 8/21/2025) REMOVED FLOOR BEAM SECTION FROM F/S 1006 TO F/S 1088 IAW CRJ 900 SRM 53-00-41-201-001-A03 AND INSTALLED NEW FLOOR BEAM SECTIOSDR SWI2025F01111Floor Support · corrodedINTERNAL STRUCTURE, FLOOR BEAM LBL9 HAS CORROSION AND SCRATCHES BETWEEN FS1000 TO FS1088, HN00238046 (C-CHECK RO 8/21/2025) REMOVED AND INSTALLED NEW FLOOR BEAM SECTION FROM F/S 1006 TO F/S 1080 IAW CRJ 900 SRM 53-00-41-201-001-A03 AND REO 690-53-61-SDR SWI2025F01110Floor Support · corrodedINTERNAL STRUCTURE, FLOOR BEAM LBL27 HAS CORROSION AND SCRATCHES BETWEEN FS1000 TO FS1088, HN00238044 (C-CHECK RO 8/21/2025) REMOVED FLOOR BEAM SECTION FROM F/S 977 TO F/S 1060 IAW CRJ 900 SRM 53-00-41-201-001-A03 AND INSTALLED NEW (-16) FLOOR BEAMSDR SWI2025F01109Floor Support · corrodedRIGHT FLOOR SILL IS CORRODED FS280 €“ 319 (C-CHECK RO 8/21/2025) INSTALLED NEW R/H FLOOR SILL BETWEEN F/S 280 TO F/S 319 IAW CRJ 900 SRM 51-42-06-001-001-A01 AND CRJ 900 SRM 51-42-13-001-001-A01 AND DWG SH690-32170 REV. AD ,COMPLIED WITH 51-900-1002-SKSDR SWAA2025060664574Intercostal · elongatedELONGATED HOLES ON INTERCOSTAL LOCATED BS 540 BTW BL 0 TO LBL 24.75 WL 208.1 AT PASSENGER CABIN 2025-290920 <[01]. REMOVED BREAKE ASSY PANEL LOCATED BS 540 BTW BL 0 TO LBL 24.75 WL 208.1 AT PASSENGER CABIN DUE TO NO FOUND ALLOWABLE DAMAGE ON B737-700 SRM 53-3SDR SWAA2025060664575Angle · crackedCRACK ON ANGLE LOCATE FLOOR STRUCTURE BS 695 LBL 24.75 AT PASSENGER CABIN 2025-290926 <[01]. TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 29-JAN-26; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 28-SDR SWAA2025060564372Angle · crackedCRACK ANGLE THAT ATTACH LANYARD LOCATED ABOVE CUT OUT PANEL 142KW BS 787 MORE 4 INCHES BTW STRINGERS 24R AND 23R AFT CARGO 2025-290884<[01] REPLACED ANGLE THAT ATTACH LANYARD LOCATED ABOVE CUT OUT PANEL 142KW BS 787 MORE 4 INCHES BTW STRINGERS 24R AND 23R AFT SDR SWAA2025060564576Angle · crackedCRACK ON ANGLE LOCATE FWD FACE BS 695 RBL 1 WL 208.1 AT PASSENGER CABIN 2025-290929<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 29-JAN-26; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 28-JAN-2SDR SIMA20250426001Gusset · corrodedSSI 53-23-005: AFT GALLEY RH CENTER FLOOR BEAM SPLICE AT FR 90 CORRODED (LEVEL 2 CORROSION). RAR AFT GALLEY RH CENTER FLOOR BEAM SPLICE AT FR 90 IAW EMB 170 SRM 51-40-08SDR SIMA20250426002Shear Panel · corrodedSSI 53-23-005: AFT GALLEY RH SHEAR PANEL CORRODED AND HAS NUMEROUS CORRODED RIVETS (LEVEL 2 CORROSION). RAR AFT GALLEY RH SHEAR PANEL IAW ERJ 170 SRM 51-40-08.SDR AALA202505223531Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL FRM BS 950 TO BS 967 AT RBL 48. REPLACE INTERCOSTAL PER AARD 51-00-05-1.SDR SWAA2025052164584Bracket · crackedRT AC BAY BRACKET ASSY PN: 212A1116-1 IS CRACKED (MARKED) <[01]. REMOVED AND REPLACED RT AC BRACKET ASSY I.A.W. B737 AMM 20-50-11-910-801; TABLE 204. T/W ID: ATS348 DATE:11/2025; [02] CORRECTIVE ACTION COMPLETED.SDR AALA202505219214Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 950, LBL 24. REPLACED INTERCOSTAL PER AARD 51-00-05-01.SDR AALA202505200542Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL FROM BS 500D TO BS 500I AT S26R. REPLACED TRANSITION PANEL PER SRM 51-40-02-0G.SDR AALA202505207630Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 957, RBL 49. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202505208601Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE WEB AT STA 991.5, RBL 34. REPLACED WEB PER AARD 51-00-05-1.SDR AALA202505200857Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 950, LBL 51. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202505209943Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 950, LBL 25. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202505204236Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR SUPPORT AT BS 951, LBL 17. REPLACED SUPPORT PER AARD 51-00-01-5.SDR AALA202505201462Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 950, LBL 26. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202505205990Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL FROM BS 947.5 TO BS 967 AT LBL 52. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202505065469Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL FROM BS 500 TO BS 500A AT S26R. REPLACED TRANSITION PANEL PER AARD 51-00-05-1.SDR AALA202507316594Web · corrodedCORROSION IN SECTIONS 4 AND 7. AIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE WEB AT BS 989 AND RBL 33. REPLACED WEB PER AARD 51-00-05-1.SDR SWAA2025060657629Vapor Barrier · cracked(CUSTOMER REQUEST) CRACK ON VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN RBL 40 TO RBL 55 RH SIDE WHEEL WELL COMPARTMENT 2025-290824 <[01]. TOOL USED: CALIPER: P/N: 500-197-30; S/N: A23304055; DUE DATE: 10-NOV-25; [02] TOOL USED: SCALE P/N 91847 S/N AE-409317 DUSDR SWAA2025060657630Vapor Barrier · cracked(CUSTOMER REQUEST) CRACK ON VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN RBL 40 TO RBL 55 LH SIDE WHEEL WELL COMPARTMENT 2025-290832 (CUSTOMER REQUEST) CRACK ON VAPOR BARRIER LOCATED AT BS 663.75 BETWEEN LBL 40 TO LBL 55 LH SIDE WHEEL WELL COMPARTMENT <[01]. TOSDR ASAA2025042558150Floor Support · corrodedIN FWD GALLEY FLOOR STRUCTURE HAS AN AREA OF CORROSION IN FLOOR PANEL SCREW HOLE, JUST AFT OF STA 294.5 & LBL 10 INCHES. MARKED IN RED. GROUNDED - YES. DISPLACED CABLES MLGEA-L AND EA-L AND EB-L IAW B737-900 AMM 20-10-91. RECONNECTED AND ADJUSTED CABLE MLGEA-LSDR AALA202505206594Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE WEB AT STA 986.5, FROM RBL 30 TO RBL 34. REPLACED WEB PER AARD 51-00-05-1.SDR AALA202505206225Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE WEB AT STA 988, RBL 32. REPLACED WEB PER AARD 51-00-05-1.SDR JJBA20250507038Support · crackedCENTER FUSE I, BTW FRAME 15-16 AND BTW 9R-7R, SUPPORT ASSEMBLY FOUND CRACKED. CENTER FUSE I BTW FRAME 15-16 AND BTW STR 9R-7R SUPPORT ASSEMBLY REMOVED AND REPLACEDSDR AALA202505066365Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT INTERCOSTAL FROM BS 847 TO BS 856, AT S25R. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR JJBA20250505007Floor Support · crackedALLY FLOOR SUPPORT ON CENTER OMEGA BEAM FOUND CRACKED AT FR20 UNDER CROSSBEAM. ALLY FLOOR SUPPORT ON CENTER OMEGA BEAM AT FR 20 REMOVED AND REPLACEDSDR AALA202505018297Threshold · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LAVATORY 4F1L THRESHOLD AND FLOOR PANEL. REPLACED LAVATORY MODULE THRESHOLD (AALA202505019467) AND FLOOR PANEL (AALA202505018297) PER EA 363911.SDR AALA202505019467Threshold · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LAVATORY 4F1L THRESHOLD AND FLOOR PANEL. REPLACED LAVATORY MODULE THRESHOLD (AALA202505019467) AND FLOOR PANEL (AALA202505018297) PER EA 363911.SDR CALA2025042904315Angle · crackedRIGHT-SIDE CENTER WING BOX APPROXIMATELY STA 663 RBL 20 LATERAL ANGLES CRACKED (DOT #93-024) (REF AAR N/R 9963548) (FOR ESFR PURPOSES) ESFR UPDATEDSDR DALA2025042803298Shear Plate · crackedSHIP 3085 CRACK SHEAR PLATE BTW FR 69 TO FR 70 STR 23R AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SHEAR PLATE AND FASTENERS LOCATED BTW FR 69 TO FR 70 STR 23R AT AFT GALLEY AREA AS PER A321 SRM 51-42-11 (0933226)SDR DALA2025042803289Intercostal · corroded(LOG 0932149) CORROSION WEB - INTERCOSTAL LOCATED BS787 TO BS 794 AND AT LEVEL STR25 R AFT CARGO COMPARTMENT. REPLACED WEB - INTERCOSTAL AND FASTENERS LOCATED BS 787 TO BS 794 AND AT LEVEL STR25R AFT CARGO COMPARTMENT AS PER B737-800 SRM 51-10-02-0G ITEM 9, SRSDR DALA2025042803272Support · crackedSHIP 6710 CRACK ON SUPPORT STRUCTURE (2 EAS) ON STA 418 TO STA 460 OVER S24L AT E&E BAY. CORRECTIVE ACTION: SUMMARY OF NRC 00357. SUPPORT STRUCTURE ON STA 460 OVER S24L AT E&E BAY WAS REPAIRED PER PRI 625765-14 REV 0, ER/A 625765-14 REV ORIGINAL SECTION I: REPSDR 2025FA0000332Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, JUST AFT OF FR75 LH SIDE Z SECTION FOUND WITH CORROSION (LEVEL 2).SDR 2025FA0000330Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR78 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000329Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR80 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000327Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR70 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000326Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR78 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).
Back to JASC 5320