As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INTERNAL STRUCTURE, FLOOR BEAM LBL9 HAS CORROSION AND SCRATCHES BETWEEN FS1000 TO FS1088, HN00238046 (C-CHECK RO 8/21/2025) REMOVED AND INSTALLED NEW FLOOR BEAM SECTION FROM F/S 1006 TO F/S 1080 IAW CRJ 900 SRM 53-00-41-201-001-A03 AND REO 690-53-61-1587. REV. -- DATED: 2025-05-15. COMPLIED WITH ALL STEPS OF REO 690-53-61-1587. REV. -- DATED: 2025-05-15. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR WORK PERFORMED.