JASC 5320
Service difficulty reports · 216,056
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026080404483Scuff Plate · corrodedDURING C2 + 6 YEAR (HEAVY) CHECK IN MSP, MTC WAS ACCOMPLISHING AA 5331-01297-01C MOD WHEN THEY REPORTED CORROSION UNDER THE SCUFF PLATE, ON THE SUBJECT (PN C02313004-007 LOWER SILL, C02313004-005 ASSY.) AT SCUFF PLATE ATTACH FASTENER HOLE LOCATIONS 1 AND 9. MASDR CALA2026080218188Angle · corrodedPASSENGER CABIN AFT WET AREA FLOOR STRUCTURE BS 995 RBL 40 ANGLE FOUND CORRODED. REMOVED AND REPLACED MAIN CABIN AFT WET AREA ANGLE AT BS 995 IAW SRM 51-40-02-0G-0 AND DWG 147A5700.SDR CALA2026080218184Support Bracket · corrodedAFT CARGO, FWD OF BS 1440, STR 27R BILGE AREA, SUPPORT BRACKET HAS CORROSION. REMOVED FABRICATED AND REPLACED ANGLE AT AFT CARGO FWD OF BS 1440, S27R BILGE AREA IAW SRM 51-40-05, 51-40-02 AND DWG 146N 5398, REV A, RESTORED SURFACE PROTECTION AND APPLIED TOP CSDR SWAA2026090849637Floor Support · crackedCRACK ON FLOOR SUPPORT BTW BS 344 TO BS 360 RBL 51 WL 208.1. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG 141A5400, SHEET 14, REV -.SDR SWAA2026090804567Floor Support · corrodedCORRODED FLOOR SUPPORT, BS 947.5 - 967, LBL 50, WL 208.1. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, & DWG 147A5650, SHEET 55, REV A.SDR SWAA2026090823969Floor Support · corrodedCORROSION ON INTERCOSTAL LOCATED BTW BS 947.5 TO BS 967 RBL 50 WL 208.1 AT AFT GALLEY AREA . REPLACED INTERCOSTAL LOCATED BTW BS 947.5 TO BS 967 RBL 50 WL 208.1 AT AFT GALLEY ARE IAW B737-800 SRM 51-10-02 ITEM 9 SRM 51-40-02 AND DWG 147A5650 SHEET 71 REV A.SDR SWAA2026090875602Fitting · corrodedCORROSION ON FITTING LOCATED BTW BS 992.8 TO BS 1016 LBL 31 WL 208.1 AT AFT GALLEY AREA. REPLACED FITTING LOCATED BTW BS 992.8 TO BS 1016 LBL 31 WL 208.1 AT AFT GALLEY AREA IAW SRM 51-40-02 AND DWG 147A5700 SHEET 121 REV A.SDR SIMA20260730007Bracket · corrodedLEVEL 2 CORROSION AFT CARGO ? FR 80-81, STR 24R-27R CORROSION AT MULTIPLE LOCATIONS. (MAJOR REPAIR). AFT CARGO, FR80, STR 26R SHEAR CLIP REQUIRES REPLACEMENT DUE TO 100% MATERIAL LOSS. LOCATED AND DRILLED NEW SHEAR CLIP IAW E175-SRM 51-40-02 (PN# 170-85667-001SDR SWAA2026090768218Web · crackedCRACKED WEB LOCATED BTW BS 312 TO BS 328 LBL 47.5 WL 208.1. REPLACED THE WEB IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 141A5400, SHEET 26, REV -.SDR SWAA2026090775577Support Angle · crackedCRACK CARGO LINER SUPPORT ANGLE LOCATED BS 727B AND AT LBL 20 UPPER POSITION AT AFT CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON CARGO LINER SUPPORT ANGLE LOCATED BS 727B AND AT LBL 20 UPPER POSITION AT AFT CARGO COMPARTMENT IAW SRM 51-70-11-2R-0 .SDR SWAA2026090796735Floor Support · crackedCRACKED FLOOR SUPPORT LOCATED BTW BS 277 - 294.5, RBL 1, WL 208.1, FWD GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02 SRM 51-10-02 PARAGRAPH 9, AND DWG 141A5400, SHEET 20, REV- .SDR SWAA2026090219233Shield · corrodedCORRODED SHIELD WEB, BS 500 - 500A, RBL 21, WL156 IN THE FWD CARGO BAY. REPLACED SHIELD WEB IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, DWG 143A0080, SHEET 39, REV -.SDR SWAA2026090260931Tie Clip · crackedCRACKED TIE CLIP, BILGE AREA BS 500I, STR26L. REPLACED THE TIE CLIP IAW SRM 51-40-02, AND DWG 143A1234, SHEET 19, & SHEET 20, REV-.SDR SWAA2026090235638Support Angle · corrodedCORRODED SUPPORT ANGLE, BS 500I LBL 21 - RBL21, WL 156 IN THE FWD CARGO BAY. REPLACED THE SUPPORT ANGLE IAW SRM 51-10-02, ITEM 9, & SRM 51-40-02.SDR SWAA2026090259031Support Angle · crackedCRACK CARGO LINER SUPPORT ANGLE BS 727B LBL 51 AT AFT CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON CARGO LINER SUPPORT ANGLE BS 727B, LBL 51 IAW SRM 51-70-11-2R-0, SHEET 2, FIGURE 201.SDR SWAA2026090218272Tie Clip · crackedCRACKED TIE CLIP, BILGE AREA, BS 500I STR 26R IN THE FWD CARGO BAY. REPLACED THE TIE CLIP IAW SRM 51-40-02-0G, & DWG 143A1234, SHEET 20, REV -.SDR SWAA2026090278295Angle · crackedCRACKED ANGLE LOCATED FWD SIDE OF FRAME BS 500H, STR 26L IN THE FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-40-02-0G-0, & DWG 143A7505, SHT 117, REV-.SDR SWAA2026090250385Support Angle · crackedCRACKED CARGO LINER SUPPORT ANGLE BS 727D, LBL 51 IN THE AFT CARGO BAY. PERFORMED A REPAIR OF THE SUPPORT ANGLE BS 727D, LBL 51 IAW SRM 51-70-11-2R-0, REPAIR GENERAL. SRM 51-40-02. SRM 51-10-02.SDR SWAA2026090289879Intercostal · crackedCRACKED INTERCOSTAL LOCATED BTW BS 500A TO 500B AND RBL21 FWD CARGO BAY. REPLACED INTERCOSTAL IAW SRM 51-40-02-0G, & DWG 143A7505, SHEET 137, REV -.SDR IPXA2026082630906Stringer · crackedSTRINGER 19L CRACKED, FWD & AFT SIDE OF BS 740. ACCOMPLISHED A REPAIR IAW EO-98289-REQ0002, REV 1, SRM 53-20-03-2R-5, REV 49, EGAT WORK SHEET 60592, & EGAT EI F2026A53M-1753, SEQUENCE A, REV 0.SDR SWAA2026081753371Intercostal · crackedINTERCOSTAL, BS 259 - 277, LBL 11, WL 207.5 WAS CRACKED AT BS 259+3. REMOVED AND INSTALLED THE INTERCOSTAL IAW SRM 51-40-02-0G, & DWG 141A5210, REV-.SDR AALA202608113505Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK ON INTERCOSTAL AT STA 312 TO 328, RBL 38. MAINTENANCE REMOVED AND REPLACED NTERCOSTAL AT STA 312 TO 328, RBL 38 IAW AARD 51-00-05-1 AND BOEING DRAWING #141A5410.SDR MASA20260807200Shear Panel · corrodedDURING HEAVY CHECK INSPECTIONS OF CFIII WET AREA, CORRODED RT SHEAR PANEL AT FR 87 TO FR 88 RT. REMOVED AND REPLACED IAW SRM 51-42-01. NRG #4502680-1000-0060, REV 45 DATED MAY-28-2021.SDR MASA20260807195Floor Support · corrodedDURING HEAVY CHECK, INSPECTIONS OF CFIII WET AREA, CORRODED FLOOR SUPPORT HAS BEEN REMOVED AND REPLACED IAW SRM 51-41-01 & SRM 51-41-02. NRC 4502680-1000-0055, REV 45.SDR MASA20260807194Floor Support · corrodedDURING HEAVY CHECK, INSPECTIONS CF ILL, WET AREA, CORRODED FLOOR SUPPORT ANGLE AT FR 90 TO FR 91 RT, RBL 11 REMOVED AND REPLACED IAW SRM 51041-01 AND SRM 51-41-02. NRG# 4502680-1000-0054, REV 45.SDR MASA20260807189Floor Support · corrodedDURING HEAVY CHECK, INSPECTIONS OF CFIII WET AREA, CORRODED FLOOR SUPPORT BEAM REMOVED AND REPLACED WITH NEW IAW ERJ 175 SRM 51-43-03 AND SRM 51-41-01. NRG# 4502680-1000-0049, REV 50, DATED OCT-20-2023, AND REV AND REV 45 DATED MAY-28-2021.SDR CALA2026080218155Panel · corrodedAFT CARGO, FR 59-62, S38R, FLOOR PROFILE HAS MULTIPLE SPOTS OF CORROSION. REMOVED AND REPLACED CORRODED PROFILE PANEL WITH A NEW PROFILE PANEL. APPLIED SURFACE PROTECTION COATING.SDR CALA2026080218153Seal · damagedAFT CARGO, FR 53, STR 31-32L, VERTICAL PROFILE HAS SCRIBE MARK DOWN THE CENTER. REMOVED AND REPLACED SECTION SEALING AT AFT FR 53 STR 31-32L IAW 51-43-11.SDR CALA2026080218151Tie Down · corrodedAFT PIT FR 57 STR 42-41L. TIE DOWN PROFILE HAS CORROSION. REMOVED AND REPLACED PROFILE PLATE IAW SRM 51-42-11.SDR DALA2026080204455Shear Plate · corrodedLEVEL 2 CORROSION, UPPER FUSELAGE, AFT PAX CABIN, SHEAR PLATE CORRODED AT -Y1150 BETWEEN FR 69 TO FR 70. REPLACED SHEAR PLATE AT PAX CABIN -Y1150 BETWEEN FR 69 TO FR 70 IAW SRM 51-72-11-977-001, PARA 2, SRM REV 158.00, & AIRBUS REF DWG D53474180. (LP: 172925SDR CALA2026073118126Channel · corrodedAFT CARGO, UNDER INN SCUFF PLATE, TRANSITION PANEL, ALONG OF BS 1380 - 1440 HAS CORROSION. REMOVED CORROSION EVALUATED TRANSITION PANEL FOUND TO BE WITHIN LIMITS IAW SRM 53-60-53-01-1 DETAIL 1. INSTALLED TRANSITION PANEL REMOVED FOR ACCESS AND NEW WEB AFT CSDR CALA2026073118124Strap · crackedAFT CARGO, BS 1580 - 1600 CEILING STRAP CRACKED. REMOVED ANGLE CLIP DAMAGE IAW SRM 51-40-02, RECIERED NEW ANGLE CLIP FROM TRAVELER T26/1871532, LOCATED AND DRILLED IAW SRM 51-40 -02, TREATED AND PRIMED IAW SRM 51-20-01, TOP COATED IAW AMM 51- 212-15, INSTALLSDR VNAA202610060022Shear Panel · corrodedCORROSION ON SHEAR PANEL STA FS=1096 FROM LBL=28 TO RBL=28 AT AFT BAGGAGE BAY FLOOR STRUCTURE. SHEAR PANEL STA FS=1096 FROM LBL=28 TO RBL=28 AT AFT BAGGAGE BAY FLOOR STRUCTURE WAS REPAIRED PER REO 670-53-61-1080 REV - -SDR VNAA202610060016Drip Tray · corrodedINITIAL INSPECTION: CORROSION ON DRAIN PAN STA FS=280 LBL 13 AT PASSENGER CABIN. DRIP TRAY ASSY (DRAIN PAN) FS=280 LBL 13 AT PASSENGER CABIN WAS EVALUATED THEREFORE AREA IT IS OUT OF LIMITS PER SRM 53-21-43-101-001-A03 AND REPLACED PER CRJ900 SRM 51-42-10-001SDR VNAA202610060004Channel · damagedCORROSION ON NUT CHANNEL IN THE LH/RH MLG WHEEL WELL STRUCTURE, NEXT TO THE MLG UPLOCKS. NUT CHANNEL IN THE LH/RH MLG WHEEL WELL STRUCTURE, NEXT TO THE MLG UPLOCKS WERE REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01 AND CRJ-900 SRM 51-41-02-001-001-A01SDR REXA2026091001788Support · crackedCRACK AT CORNERS SUPPORT OF THE JB 6 MODULE AT FWD EQUIPMENT COMPARTMENT. SUPPORT OF THE JB 6 MODULE AT FWD EQUIPMENT COMPARTMENT WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01SDR SWAA2026090844421Support Angle · crackedCRACKED SUPPORT ANGLE, BODY FAIRING, BS 500I STR 19L. REPLACED SUPPORT ANGLE IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 116A3010, SHEET 59, REV A, DWG 116A3110, SHEET 8, REV -, & DWG 149A7101, SHEET 11, REV -.SDR ASAA2026072968477Web · corrodedAFT WET AREA WEB STA 987 RBL 50 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW 737-800 SRM 53-70-15-1A-1, REMOVED AND REPLACED SHEAR WEB IAW B737-800 SRM 51-40-02SDR ASAA2026072968480Floor Support · corrodedAFT WET AREA INTERCOSTAL STA 947 TO STA 967 LBL 50 CORRODED. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1, REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0 AND AMM 20-50-11-910-801.SDR ASAA2026072968475Support Angle · corrodedAFT WET AREA L/H WEB ANGLE SUPPORT STA 997 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED SUPPORT ANGLE IAW B737-800 SRM 51-40-02-0G-0. W= .5" O= .05" R= .043" L= 2" D= .007".SDR ASAA2026072968472Support Angle · corrodedAFT WET AREA L/H WEB SUPPORT ANGLE STA 1016 TO STA 987 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED SUPPORT ANGLE IAW B737-800 SRM 51-40-02-0.SDR ASAA2026072968467Web · corrodedAFT WET AREA WEB AT STA 987 LBL 50 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS, REMVOED AND REPLACED IAW B737-800 SRM 51-40-02-0G-0.SDR SWAA2026090280547Tie Clip · crackedCRACKED TIE CLIP, BS 277 STR 10R IN PAX CABIN. REPLACED TIE CLIP IAW SRM 51-40-02-0G-0, SRM 51-10-02, ITEM 9, & DWG 141A1110, SHT 54, REV -.SDR SWAA2026083127160Stiffener · corrodedCORROSION FLOOR STRUCTURE STIFFENER ON BS 947 AT LEVEL LBL 52 AND WL 208.1 AT AFT GALLEY AREA 2026-456142 REPLACED STIFFENER (INTERCOSTAL) AND FASTENERS LOCATED BTW BS 947 TO BS967 AT LEVEL LBL 52 AND WL 208.1 AT AFT GALLEY AREA IAW B737-8 SRM-51-40-02 AND DWGSDR ASAA2026072968163Shield · corrodedAFT PIT SHIELD FWD OF DOOR HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED AFT PIT SHIELD FWD OF DOOR, IAW B737-800 SRM 51-40-02-0G-0, STEP: 4.B & 5.B. (W: 1" / O: .050" / R: .040 / L: 2" / D: .010" ).SDR R61A2026082400244Rib · crackedDURING HEAVY CHECK CRACK FOUND ON LT HORIZONEAL STAB RIB 14. REMOVED AND REPLACED RIB 14 IAW SRM 51-41-02SDR R61A2026082400243Floor Support · crackedDURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE, FR 85 RBL 28AND FR 86 LBL 28 THREE FLOOR SUPPORT FOUND CRACKED. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-41-01.SDR R61A2026082400241Bracket · crackedDURING HEAVY CHECK CF III INTERNAL LT OUTBOARD SEAT TRACK TO FRAME 84 BRACKETS CRACKED. REMOVED AND REPLACED LT OTBD SEAT TRACK IAW SRM 51-43-03 AND 51-41-01.SDR R61A2026082400240Gusset · corrodedDURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE FR 91 RBL 25 GUSSET PLATE FOUND WITH CORROSION. REMOVED AND REPLACED GUSSET PLATE IAW EMB 170/175 SRM 51-41-02.SDR R61A2026082400238Floor Support · corrodedDURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE BETWEEN FR 87-90 RBL 40 PAN SUPPORT FOUND WITH CORROSION. REMOVED AND REPLACE PAN SUPPOT IAW EMB 170/175 SRM 51-42-01 AND 51-43-01
Back to JASC 5320