SDR R61A2026082400237Splice · corrodedDURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE FR 90 BL 0 SPLICE FOUND WITH CORROSION. REMOVED AND REPLACED SPLICE IAW EMB 170/175 SRM 51-43-01.SDR R61A2026082400236Shear Panel · corrodedDURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE BETWEEN FR 87-88 MIDDLE SHEAR PANEL FOUND WITH CORROSION. REMOVED AND REPLACED SHEAR PANEL IAW EMB 170/175 SRM 51-42-01.SDR R61A2026082400235Shear Panel · corrodedDURING HEAVY CHECK AFT WET AREA FLOOR STRUCTURE BETWEEN FR 87- 88 L/H SHEAR PANEL FOUND WITH CORROSION. REMOVED AND REPLACED SHEAR PANEL IAW EMB 170/175 SRM 51-42-01 AND 51-42-02SDR MASA20260807190Floor Support · corrodedDURING HEAVY CHECK INSPECTIONS OF CFIII WET AREA, CORRODED FLOOR SUPPORT BEAM FR 86 TO FR 89 R/H, RBL 11 REMOVED AND REPLACED IAW ERJ 175 SRM 51-41-01 AND SRM 51-43-01. NRC # 4502680-1000-0050 REV 46 DATED DEC-30-2021 AND REV 45 DATED MAY-28-2021.SDR MASA20260807188Plate · corrodedDURING HEAVY CHECK INSPECTIONS INTERNAL CFIII CORRODED FLOOR SUPPORT PLATE AT FR 85 TO FR 86 RT, RBL 11, HAS BEEN REMOVED AND REPLACED IAW ERJ 175 SRM 51-41-01, SRM 51-43-01. NRC# 4502680-1000-0046, REV 45 MAY-28-2021. REV46 DEC-03-2021.SDR AALA202608048264Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL AT STATION 312 TO 328, LBL48. MAINTENANCE REPLACED INTERCOSTAL AT STATION 312 TO 328, LBL48 PER AARD 51-00-05-1.SDR AALA202607318060Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: INTERCOSTAL CRACKED AT STATION 277 TO 294.5. MAINTENANCE REPLACED INTERCOSTAL AT STATION 277 TO 294.5 PER AARD 51-00-05-1.SDR DALA2026073104438Floor Support · corrodedPER MTX REQUESTED OI, FOUND CORROSION ON FLOOR SUPPORT BEAM FR 76-78, AT RBL 37. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0196:2531-4003/015 00578 COMPLIED WITH ERA 635283-14 PRI REV 0, 1, 2, AND ERA 635283-14 RSDR UIEA2026061200465Web · corrodedM/D BS 1180 RHS O/B BELOW FLOOR INTERCOSTAL WEB FOUND CRACK(<P>WEB CRACK AREA REPAIRED AS PER SRM 51-10-02 AND NEW WEB HOLES TRANSFERRED AS PER SRM 51-40-05 AND NEW WEB INSTALLED AS PER SRM 51-40-02. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026061300469Floor Support · corrodedM/D STA 1200 LBL 105 BELOW FLOOR INTERCOSTAL WEB FOUND CRACKED(<P>WEB REPAIRED AS PER RI-53-40-18377 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026061300475Fitting · crackedRH BS 1480 LONGERON EXTENSION FITTING RADIUS AREA FOUND 1EA CRACK(<P>LONGERON EXTENSION FITTING REPLACED AS PER ATLAS AIR EO 4453A818 REV 20 PART 4. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026061500489Panel · nickedM/D LHS BS 1620 TO 1720 DADO PNL AFT EDGE FOUND NICKED. DADO PANEL NICK AREA REPAIRED AS PER RI-25-21-18349 REV A. NO FURTHER DEFECTS NOTED.SDR UIEA2026061500492Floor Support · crackedAFT CARGO STA 1920 RT O/B WALKAWAY FLOOR PNL CUTOUT SUPPORT FOUND 1EA CRACKED. SUPPORT REPAIRED AS PER ATLAS AIR EA-4425A268 REV 1. NO FURTHER DEFECTS.SDR UIEA2026061500493Profile · crackedM/D BS 1140 TO 1160 RHS O/B RBL 116" L PROFILE FASTENER HOLE FOUND CRACK(<P>ANGLE CRACK AREA REPAIRED AS PER RI-53-44-18392 REV A. NO FURTHER DEFECTS NOTED </P>)SDR UIEA2026061500495Panel · crackedAFT CARGO STA 1920 RH O/B WALKWAY FLOOR PANEL AFT CUTOUT FOUND 1EA CRACKED. PANEL CRACK AREA REPAIRED AS PER ATLAS AIR EA-4425A268 REV 1. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026061700514Channel · crackedRT STA 840 UPPER DECK TENSION TIE FWD CHANNEL FOUND CRACK. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026061800527Frame · crackedLH STA 720 UPPER DECK FRAME 1EA FASTENER HOLE CRACK. CRACK FASTENER HOLE REPAIRED AS PER ATLAS AIR EO 4453A301 REV 12 ITEM 4F. NO FURTHER DEFECTS NOTED.SDR UIEA2026062200534Channel · crackedL/H STA 720 UPPER DECK TENSION TIE FWD CHANNEL UPR FLANGE CRACKED. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026062500541Angle · corrodedNR 1 PACK LOWER ASSY AFT LOWER SUPPORT ANGLE CORROSION. ANGLE FABRICATED AS PER BOEING DWG 65B41701 & PL AND NEW ANGLE HOLES TRANSFERRED AS PER SRM 51-40-05 AND NEW ANGLE INSTALLED AS PER SRM 51-40-02. NO FURTHER DEFECTS NOTED.SDR UIEA2026062500542Angle · corrodedNR 2 PACK LOUVER ASSY AFT LOWER ANGLE CORROSION. ANGLE FABRICATED AS PER BOEING DWG 65B41701 AND PL AND NEW ANGLE HOLES TRANSFERRED AS PER SRM 51-40-05 AND NEW ANGLE INSTALLED AS PER SRM 51-40-02. NO FURTHER DEFECTS NOTED.SDR UIEA2026062500543Channel · crackedSTA 740 LH UPPER DECK TENSION FWD CHANNEL FOUND FASTENER HOLE CRACKED. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026062500544Channel · crackedLH STA 760 UPPER DECK TENSION TIE FWD CHANNEL FOUND 2EA FASTENER HOLES CRACKED. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026062500545Channel · crackedRH BS 720 UPPER DECK TENSION TIE AFT CHANNEL 1EA FASTENER HOLE CRACKED. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026062700546Channel · crackedRH STA 860 UPPER DECK TENSION TIE FWD CHANNEL 1EA FASTENER HOLE CRACKED TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS.SDR UIEA2026062700547Channel · crackedSTA 780 LH UPPER DECK TENSION TIE FWD CHANNEL ONE EACH FASTENER HOLE CRACKED. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026062700548Channel · crackedSTA 820 LH UPPER DECK TENSION TIE AFT CHANNEL 1EA FASTENER HOLE CRACK. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED.SDR UIEA2026062700549Channel · crackedSTA 860 LH UPPER DECK TENSION TIE AFT CHANNEL 2EA FASTENER HOLES CRACK. TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTEDSDR UIEA2026062900553Channel · crackedRH STA 760 UPR DECK TENSION TIE FWD CHANNEL 2EA FASTENER HOLES CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. <SPAN>NO FURTHER DEFECTS NOTED</SPAN></P>)SDR UIEA2026062900554Channel · crackedRH STA 900 UPPER DECK TENSION TIE AFT CHANNEL 1EA FASTENER HOLE CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. <SPAN>NO FURTHER DEFECTS NOTED</SPAN></P>)SDR UIEA2026063000555Channel · crackedRH STA 800 UPPER DECK TENSION TIE AFT CHANNEL 1EA FASTENER HOLE CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. <SPAN>NO FURTHER DEFECTS NOTED</SPAN></P>)SDR UIEA2026063000556Channel · crackedRH STA 740 UPPER DECK TENSION TIE FWD CHANNEL 2EA FASTENER HOLES CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. <SPAN>NO FURTHER DEFECTS NOTED</SPAN></P>)SDR UIEA2026070100566Channel · crackedLH STA 920 UPPER DECK TENSION TIE FWD CHANNEL 1EA FASTENER HOLE CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026070700577Channel · crackedLH STA 880 UPPER DECK TENSION TIE FWD CHANNEL 1EA FASTENER HOLE CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1 AND RI-53-20-18366 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026070700579Channel · crackedRH STA 880 UPPER DECK TENSION TIE FWD CHANNEL 2EA FASTENER HOLES CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1 AND RI-53-20-18365 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026070700580Channel · crackedLH STA 840 UPPER DECK TENSION TIE FWD CHANNEL FOUND CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1 AND RI-53-20-18364 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026071300600Floor Support · crackedLOWER CHORD ( 2EA ) FASTENER HOLES CRACK AT M/D STA 1220 LH O/B BELOW FLOOR INTERCOSTAL WEB FWD LOWER.(<P>LOWER CHORD REPAIRED AS PER RI-53-40-18378 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026071300601Floor Support · crackedLOWER CHORD 3EA FASTENER HOLE CRACK AT M/D STA 1200 RH BELOW FLOOR INTERCOSTAL WEB FWD LOWER AREA(<P>LOWER CHORD REPAIRED AS PER RI-53-40-18382 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026071400605Support · damagedFX AIR COND BAY #2 PACK HEAT EXCHANGER FWD I/B SUPPORT TRIANGLE PLATE MOUNT BOLT HOLE ELONGATED(<P>LOCAL FABRICATED PLATE P/N 69B40167-1 AS PER RI-21-52-18421 REV A AND BOEING DRAWING 69B40167. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026071600609Fitting · crackedM/D BS 1920 LBL 107" TO LBL 116" SUPPORT WATER DAM FTG CRACK(<P>SUPPORT WATER DAM FTG REPAIRED AS PER RI-53-60-18432 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026071900611Floor Support · crackedLOWER CHORD 2EA FASTENER HOLES CRACK AT M/D STA 1220 RH O/B BELOW FLOOR INTERCOSTAL WEB FWD LOWER AREA(<P>LOWER CHORD REPAIRED AS PER RI-53-40-18381 REV A.NO FURTHER DEFECTS NOTED </P>)SDR UIEA2026072000612Web · crackedM/D STA 1200 LBL 105 - LBL 109 BELOW FLOOR INTERCOSTAL WEB FWD LWR CHORD ( 2EA ) FASTENER HOLES CRACK(<P>LOWER CHORD REPAIRED AS PER RI-53-40-18377 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026072000614Channel · crackedSTA 900 LH UPPER DECK TENSION TIE AFT CHANNEL EA FASTENER HOLE CRACK(<P>TENSION TIE REPAIRED AS PER SRM 53-20-30-2R-1 REPAIR 1 AND RI-53-20-18410 REV A. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2026072600656Web · corrodedLOWER CHORD FASTENER HOLE CRACK AT M/D BS 1180 LH O/B BELOW FLOOR INTERCOSTAL WEB LOWER AREA(<P>LOWER CHORD REPLACED AS PER SRM 51-10-02 AND NEW CHORD HOLES TRANSFERRED AS PER SRM 51-40-05 AND NEW CHORD INSTALLED AS PER SRM 51-40-02. NO FURTHER DEFECTS NOTED.SDR JR2R20260729429Strap · corrodedRBL10 BETWEEN FR 85 TO FR 86 UPPER STRAP CORRODED. REPLACEDSDR JR2R20260729439Strap · corrodedLBL10 BETWEEN FR 85 TO FR 86 UPPER STRAP CORRODED. REPLACEDSDR JR2R20260729445Gusset · corrodedFR 90, LBL 10 GUSSET CORRODED. REPLACEDSDR JR2R20260729432Splice · corrodedFR87 TO FR88 O/B DOUBLER SPLICE CORRODED. REPLACEDSDR JR2R20260729431Floor Support · corrodedRBL10 BETWEEN FR87 TO FR89 FLOOR SUPPORT CORRODED. REPLACED.SDR JR2R20260729420Floor Support · corrodedBETWEEN FR19 TO FR20 O/B FLOOR SUPPORT BEAM IS CORRODED. REPAIRED PER ETD.SDR VNAA202610060018Fitting · corrodedCORROSION ON FWD/AFT HINGE HOUSINGS ON LOWER SILL OF THRESHOLD AT PASSENGER DOOR. FWD AND AFT HINGE (FITTING) HOUSINGS ON LOWER SILL AT PASSENGER DOOR WERE EVALUATED THEREFORE IS OUT LIMITS PER SRM 53-21-23-101-001-A02 AND WERE REPLACED PER SRM 51-42-21-001-
Back to JASC 5320