JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024041564266Web · corrodedCORROSION ON FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B LBL-3<[01] REMOVED AND REPLACED FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B LBL-3 IAW SRM 51-40-02 AND DWG:146A7500 REV:A;[02] VERIFIED CORRECTIVE ACTION & MEASUREMENTS FISDR SWAA2024041564270Support · corrodedCORROSION ON ACB FLOOR TO SIDEWALL SUPPORT STA-727 TO 767 RBL-20<[01] REMOVED FABRICATED AND INSTALLED ACB FLOOR TO SIDEWALL SUPPORT BS 727 TO BS 767 RBL20 WL 156 MATERIA USING BAC1496-377#7075T62 LOT:1549286-2 IAW SRM 51-40-02- DWG 146A7502 REV:- AND DWG 146ASDR SWAA2024041564297Shield · corrodedCORROSION ON ACB FWD SHIELD.<[01] CORROSION ON ACB FORWARD SHIELD FOUND TO BE OUT OF ALLOWABLE DAMAGE LIMITS DUE TO NO ALLOWABLE GIVEN IN SRM. REPAIR BY REPLACEMENT IAW SRM 51-10-02;[02] VERIFIED.SDR SWAA2024041564298Strap · corrodedCORROSION ON FWD FLOORBOARD STRAP ACB STA-767+3''<[01] RECEIVED NEW ACB FLOOR BOARD T-STRAP BS 767+3' FROM STORES. PART IS TO BE INSTALLED ON CUSTOMER CARD #TTG8Q00RJLCR.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024041564299Strap · corrodedCORROSION ON NUT-PLATE STRAP ACB STA-787+3'' RBL-21<[01] REMOVED AND INSTALLED NEW NUT-PLATE STRAP ON AFT CARGO BAY BS 787+3'; RBL 21 I.A.W. SRM 51-40-02-0G-0; DWG# 146A8340 SHEET 19;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2024041564284Strap · corrodedCORROSION ON TENSION STRAP THRESHOLD AREA ACB DOOR<[01] REMOVED AND INSTALLED NEW TENSION STRAP ON ACB P/N 146A8128U14 I.A.W. SRM 51-40-02-0G-0 DWG.# 146A8120SDR SWAA2024041564285Web · corrodedCORROSION ON THRESHOLD WEB ACB<[01] UPDATE TO WATERLINE;[02] CERTIFY;[03] 01 - REMOVED AND REPLACED PER [SRM 51-40-02-0G-0-A00729 (GENERAL - FASTENER INSTALLATION AND REMOVAL - AIRFRAME - PERMANENT)]<BR><BR>TASK CARD COMPLETED.;[04] VERIFIED CORRECTIVE ACTION SDR R61A2024041200174Web · corrodedCREW OXYGEN REINFORCEMENT WEB FOUND CORRODED ON CFI FWD CARGO BTWN FR23-24 S21R. MX REPLACED PN 170-67676-001 IAW SRM 51-41-01, 51-43-03SDR ASAA2024031648950Floor Support · crackedINTERCOSTAL CRACKED AT L1 DOOR FLOOR STRUCTURE. GROUNDED - YES. REMOVED AND REPLACED INTERCOSTAL IAW B737-800 SRM 51-40-02-0G-0.SDR SWAA2024040564170Support Plate · corrodedREJECTED OK TO INSTALL RH FLOOR TO SIDEWALL SUPPORT PLATE; CORROSION ON INTERCOSTAL; BS 747 TO 767; RBL 21; UNDERSIDE OF UPPER FLANGE AT NUTPLATE HOLES.<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD # TTG8Q00S3H60.;[02] THIS TASK CARD WILL BE ACCSDR SWAA2024040564171Angle · corrodedCORROSION ON BS947 LOWER CENTER BULKHEAD SUPPORT ANGLE; RBL 23 ON UNDERSIDE OF FLANGE<[01] REMOVED AND REPLACED LOWER CENTER BULKHEAD SUPPORT ANGLE AT BS 947 P/N 149A8118-29 LOT: 1519863-1 IAW SRM 51-40-02 AND DWG 149A8117.;[02] VERIFIEDSDR SWAA2024040564172Angle · corrodedCORROSION ON BS947 LOWER RIGHT BULKHEAD SUPPORT ANGLE; RBL 24 ON UNDERSIDE OF FLANGE<[01] REMOVED AND REPLACED NEW ACB BS 947 RH BULKHEAD SUPPORT ANGLE ; IAW SRM 51-40-02 AND DWG # 149A8118.;[02] VERIFIEDSDR SWAA2024040364435Scuff Plate · crackedFORWARD SERVICE DOOR SCUFF PLATE IS CRACKED ALONG EDGE. (MARKED)<[01] STEPS # 1 AND STEP # 4 COMPLETE;;[02] REPAIR COMPLETE;[03] VERIFIED TASK COMPLETEDSDR IPXA2024040117865Shear Plate · crackedCRACK FOUND AT FWD SIDE OF FRAME 65 STR 42 ON INTERCOSTAL. INSTALLED SHEAR PLATE AT FWD SIDE OF FRAME 65 STR 42 IAW A300 SRM 51-40-21 PARAGRAPH 6 AND 7.SDR DALA2024032103577Diaphragm · crackedCRACK AND PUNCTURE ON DIAPHRAGM BTW STA X=-44 AND X=-56 FROM STA Y=257 APPROX AT PASSENGER CABIN. SUMMARY OF NRC 00707: DIAPHRAGM BTW STA X=-44 AND X=-56 FROM STA Y=257 APPROX AT PASSENGER CABIN WAS REPAIRED PER B717-200 SRM 53-00-55-2R-4 REPAIR 4 AND 53-00-00SDR CALA2024031900781Floor Support · cracked(SUPPORT TASK) MAIN CABIN FLOOR STRUCTURE INTERCOSTAL LOCATED AT STA 344-360 BL0 CRACKED. T REPLACED INTERCOSTAL 141A5410N147 LOCATED AT STA 344-360 BL0 IAW B737-900ER SRM 51-40-05, SRM 51-40-02 AND BOEING DWG 141A5400 S HEET 32 REV-.SDR DALA2024031803398Shield · corroded(LOG 0249310) AFT CARGO DOOR, AFT SHEILD HAS MULTIPLE AREAS OF CORROSION STA 847-867, RBL 25, WL 70. REMOVED AND REPLACED AFT SHIELD FROM STA: 847-867, RBL = 25, WL 70 AT AFT CARGO IAW B737 SRM 51-40-02-0G AND DWG = 146A8127.SDR DALA2024031803396Web · corroded(LOG 0247799) AFT CARGO DOOR THRESHOLD WEB HAS CORROSION ON UPPER SURFACE. REMOVED AND REPLACED AFT CARGO DOOR THRESHOLD WEB STA 794 TO 847 IAW B737-800 SRM 51-40-02-0G, DWG 146A8340.SDR AALA202403185985Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR INTERCOASTAL AT STA 537.45, RBL 2. REPLACED INTERCOSTAL PER SRM 51-40-05.SDR DALA2024031703384Intercostal · corrodedAIRCRAFT 0699, CORROSION ON INTERCOSTAL ON STRINGER 28L STA 1400 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: INTERCOSTAL ON STRINGER 28L STA 1400 AT AFT CARGO COMPARTMENT WAS FABRICATED AND REPLACED PER B757-200 DWG 146N5400 REV. U AND B757-200 SRM 51-40 -02-SDR 2024FA0000911Bracket · crackedFLAP HANDLE FORWARD SUPPORT BRACKET FOUND CRACKED. NOTED AREA OF STRESS/CRACK A LACK OF RADIUS. REPLACED WITH FACTORY NEW BRACKET.SDR 2024FA0000906Support Bracket · crackedFLAP HANDLE FORWARD SUPPORT BRACKET FOUND CRACKED. NOTED AREA OF STRESS/CRACK A LACK OF RADIUS. REPLACED WITH FACTORY NEW BRACKET.SDR REXA2024103001201Drain Pan · deformedFS 280 RH DRAIN PAN HAS SEVERAL ELONGATED HOLES AND POPPED RIVETS. REPAIRED IAW ENDEAVOR AIR EA CRJ953-16255 REV A DATED 3/25/2024.SDR SWAA2024042664037Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED BS 727D CEILING AREA AFT CARGO COMPARTMENT 2024-195702 CRACK ANGLE - SUPPORT LOCATED BS727A TO BS747 CEILING AREA AFT CARGO COMPARTMENT<[01] PERFORMED DETAILED VISUAL INSPECTION ON ANGLE - SUPPORT LOC. AT BS727A TO BS747 CEILING ASDR SWAA2024041964200Scuff Plate · crackedCRACK SCUFF PLATE FWD CORNER AT FWD CARGO COMPARTMENT 2024-206148<[01] TOOL USED DIGITAL CALIPER P/N:500-196-30; S/N: A23329368; DUE DATE: 06/MAR/25.;[02] TOOL USED: RADIOMETER PHOTOMETER. P/N: XRP-3000. S/N: 1753759. DUE DATE: 12-APR-24.;[03] REPAIRED THE FWDSDR SWAA2024041863556Channel · corrodedCORROSION FOUND AFT CARGO RH 'Z' CHANNEL FROM STA 727B TO STA 727C RBL 21 WL 155.5 HAS SPOT OF CORROSION.<[01] REMOVED AND REPLACED R/H Z-CHANNEL AT AFT CARGO COMPT FROM STA 727 TO STA 767 RBL 21 PER REF SRM 51-40-02-0G-0 AND DWG #146A7500;[02] VERIFIED 1.SDR SWAA2024041863550Channel · corrodedCORROSION FOUND AFT CARGO RH 'Z' CHANNEL FROM STA 727D TO STA 727E RBL 21 WL 155.5 HAS SPOTS OF CORROSION.<[01] R/H Z-CHANNEL WAS REMOVED AND REPLACED ON TASK CARD TTG8Q00S52GA.;[02] VERIFIED 1.SDR SWAA2024041863557Channel · corrodedCORROSION FOUND AFT CARGO RH 'Z' CHANNEL FROM STA 727E TO STA 747 RBL 21 WL 155.5 HAS SPOTS OF CORROSION.<[01] R/H Z-CHANNEL WAS REMOVED AND REPLACED ON TASK CARD TTG8Q00S52GA.;[02] VERIFIED 1.SDR SWAA2024041863558Channel · corrodedCORROSION FOUND AFT CARGO RH 'Z' CHANNEL FROM STA 747 TO STA 767 RBL 21 WL 155.5 HAS SPOTS OF CORROSION.<[01] R/H Z-CHANNEL WAS REMOVED AND REPLACED ON TASK CARD TTG8Q00S52GA.;[02] VERIFIED 1.SDR SWAA2024041864013Support Angle · corrodedCORROSION ** AFT OF AFT CARGO COMPARTMENT R/H LOWER SIDEWALL SUPPORT ANGLE LOWER END UNDER AROUND DOME NUT PLATE MKD DOT<[01] REMOVED AND REPLACED LWR FLOOR SUPPORT ANGLE AT AFT CARGO COMPT STA 947 PER REF SRM 51-40-02-0G-0 AND DWG #149A8117;[02] VERIFIED STEPSDR SWAA2024041864146Support · corroded**CORROSION** FWD CARGO AFT BULKHEAD R/H LOWER SUPPORT HAS CORROSION AT UPPER SURFACE I/B END MKD (107-002)<[01] REMOVE CORROSION AT FWD CARGO AFT BULKHEAD R/H LOWER SUPPORT PER REF SRM 51-10-02-0G-0; EVALUATED REWORKED AREA; ORIGINAL MAT:0.071'; MAT LOSS:0.00SDR SWAA2024041864148Support Plate · corroded**CORROSSION** FWD CARGO R/H SIDE PLATE SUPPORT UPPER SURFACE BETWEEN STA 480+12' AND 500A HAS CORROSION AROUND FASTENER HOLES MKD (107-004)<[01] REMOVED AND REPLACED NEW PLATE (SHIELD) AT FWD CARGO R/H SIDE FROM STA 480+12' TO STA 500A PER REF SRM 51-40-02-0GSDR SWAA2024041563769Floor Support · crackedCRACKED INTERCOSTAL AT STA 344+9; LBL 11; WL 208.1.<[01] UPDATED MEASUREMENT TABLE AND STEPS 1-3;[02] UPDATED STEPS 4;5;[03] STEP 5 COMPLETE;[04] MEASURMENT TABLE EDIT. PART IS NOT RII FOR REMOVAL AND REPLACEMENT.;[05] CERTIFY EDIT TO MEASUREMENT TABLE;[06] STSDR SWAA2024041563776Floor Support · crackedCRACKED INTERCOSTAL AT STA 344+9 BL 0; WL 208.1<[01] STARTED FASTENER REMOVAL IAW SRM 51-40-02-0G-0;[02] UPDATED STEPS 1-3;[03] STEPS 4;5 UPDATED;[04] UPDATED MEASUREMENT TABLE;[05] STEP 5 COMPLETE;[06] EVALUATED CRACKED INTERCOSTAL AND FOUND IT TO BE OUT OF LSDR SWAA2024041563770Floor Support · corrodedCORROSION ON INTERCOSTAL FASTENER HOLES AT STA 328+3; AND STA 328+11; LBL 12; WL 208.1<[01] UPDATE STEPS 1;2;[02] UPDATED MEASUREMENT TABLE;[03] UPDATE STEP 3;[04] STEP 3 COMPLETE.;[05] ADDED SUMMARY STATEMENT TO STEP 3.;[06] SUMMARY STATEMENT: INTERCOSTAL OUTSDR SWAA2024041563771Floor Support · crackedCRACKED INTERCOSTAL AT STA 312+8; LBL 46; WL 208.1<[01] UPDATED MEASUREMENTS TABLE;[02] REMOVED AND REPLACED INTERCOSTAL AT BS312-BS328 LBL46; PER SRM 51-40-02 AND DWG#141A5400.;[03] VERIFIED ACTION #2SDR SWAA2024041563782Floor Support · crackedCRACKED INTERCOSTAL AT STA 277+7 AND 277+13; BL 0; WL 208.1<[01] REMOVED AND REPLACED INTERCOSTAL AT BS 277-BS294.5 PER SRM 51-40-02 AND DWG#141A5400.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563783Support · corrodedCORROSION ON R1 DOOR THRESHOLD SUPPORT FROM STA 294+9 TO 312+13; RBL 58-60; WL 209.<[01] UPDATED P/N;[02] CERTIFY;[03] REMOVED CORROSION ALONG FSD R1 DOOR THRESHOLD SUPPORT AT RBL55; WL208; BS58-60 + 5'; L:1' X W:1' D: 0.013' FROM ORIGINAL THICKNESS IS 0.090' SDR SWAA2024041563780Channel · corrodedCORROSION ON R1 MOP SILL FROM STA 294.5 TO STA 328; RBL 55-61; WL 208 TO 209.<[01] UPDATE TO P/N;[02] CERTIFY;[03] REMOVED AND REPLACED MOP SILL BETWEEN BS 259 TO BS 360; RBL 53;WL 208 PER SRM 51-40-02 AND DWG 141A8310 REV.-.SDR SWAA2024041563779Floor Support · crackedCRACKED INTERCOSTAL AT STA 312+5; RBL 30; STA 208.<[01] UPDATED TABLE;[02] UPDATED STEPS 1-4;[03] REMOVED AND REPLACED INTERCOSTAL PER SRM 51-40-02-0G-0 AND DWG: 141A5400.;[04] UPDATED MEASUREMENTS TABLE.SDR SWAA2024041563777Channel · corrodedCORROSION ON L1 DOOR MOP SILL FROM STA 294.5+16 TO STA 344; LBL 55-61; WL 208.2<[01] UPDATED MEASUREMENT TABLE;[02] UPDATE STEPS 1;2;[03] PARTIAL UPDATE STEP 3;[04] STEP 3 COMPLETE;[05] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024041563800Shear Web · corrodedCORROSION ON SHEAR WEB AFT WET AREA STA-1016 LBL-3 WL 208.<[01] UPDATED MEASUREMENTS TABLE;[02] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.;[03] UPON FSDR SWAA2024041563801Shear Web · corrodedCORROSION ON SHEAR WEB AFT WET AREA STA-1016 RBL-3 WL 208<[01] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.;[02] UPDATED MEASUREMENTS TABLE.;[03] VERIFISDR SWAA2024041563804Shear Web · corrodedCORROSION ON SHEAR WEB AFT WET AREA STA-1016 LBL-40 APPROX. WL 208<[01] UPON FURTHER INVESTIGATION FOUND PRIMER CHIPPED AND RIVETS DAMAGED AT BS 1006+3 AND 1006+4 AND 1016. CLEANED AREA AROUND THE FASTENERS AT BS 1006+3 AND 1006+4 AND WEB AT BS 1006 PER SRM 51SDR HNAA2024040800317Floor Support · corrodedE028189 CENTER OMEGA BEAM GUSSET #2 HAS CORROSSION. RAR CENTER OMEGA BEAM GUSSET#2 IAW EMB 145 SRM 51-40-02. SEE WIPS AND TASK FOR DETAILS.SDR JJBA20240404010Floor Support · corrodedAT CF1 FLOOR STRUCTURE AREA, CORROSION FOUND ON R/H SILL BTW FR 19-20. FLOOR STRUCTURE AREA, ON R/H SILL BTW FR19-20 LAYOUR PERFORMED AND DOUBLE REPAIR PART FABRICATED. AT CF1 FLOOR STRUCTURE AREA, ON R/H SILL BTW FR19-20 CUT-OUT PERFORMED AND DOUBLE REPAIR PSDR HNAA2024040100245Floor Support · corroded00210 LH Y-479 FLOOR BEAM CAP IS CORRODED BETWEEN FRM48 AND FRM50. REMOVED AND REPLACED LH Y-479 FLOOR BEAM CAP BETWEEN FRM46 AND FRM53 IAW EMB-145 SRM 51-40-02-PRSDR HNAA2024040100243Floor Support · corroded00206 CENTER Y 0 FLOOR BEAM CAP IS CORRODED BETWEEN X11990 AND X13200. : INSTALLED NEW SERVICEABLE CENTER Y 0 FLOOR BEAM CAP BETWEEN X11990 AND 13200 IAW EMB145 SRM 51-40-02.SDR JJBA20240322079Door Sill · corrodedCF1 RH SIDE SERVICE DOOR FWD SILL CORRODED AT FR 18 AND 20 AROUND ANCHOR NUT. CF1 RH SIDE SERVICE DOOR FWD SILL BLENDED AT FR18 AND FR20 AROUND ANCHOR NUT AND FOUND OUT OF LIMITS. RH SIDE SERVICE DOOR FWD SILL AT FR18 REPAIR CARRIED OUT. RH SIDE SERVICE DOOR SSDR DALA2024032103574Floor Support · corrodedCORROSION ON FLOOR SUPPORT BTW STA Y=160-200 X=6, X=0 AND X=-6. SUMMARY OF NRC 00620: CORROSION LEVEL 2. FLOOR SUPPORTS BTW STA Y=160-200 X=6, X=0 AND X=-6 WERE REPLACED PER B717-200 SRM 51-41-01-0G, 51-41-02-0G, AND 51-41-05-0G. (LP #0246907)
Back to JASC 5320