JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022071125533Bulkhead · delaminatedDELAMINATED BULKHEAD PANEL 121HW FIBER PLY FWD CARGO COMPARTMENT 2022-268391 / [01] REPAIRED BULKHEAD PANEL 121HW IAW B737-700 AMM 25-52-01-300-804 AND AMM 25-52-00-200-803.;[02] REPAIRED BULKHEAD PANEL 121HW IAW B737-700 AMM 25-52-01-300-804 AND AMM 25-52-00-SDR SWAA2022071125534Bulkhead · delaminatedDELAMINATED BULKHEAD PANEL 121EW FIBER PLY FWD CARGO COMPARTMENT 2022-268392 / [01] REPAIRED BULKHEAD PANEL 121EW IAW B737-700 AMM 25-52-01-300-804 AND AMM 25-52-00-200-803.;[02] REPAIRED BULKHEAD PANEL 121EW IAW B737-700 AMM 25-52-01-300-804 AND AMM 25-52-00-SDR SWAA2022070725578Floor Panel · crackedAFT CARGO FIBERGLASS FLOOR PANEL JUST FORWARD OF THE METAL FLOOR PANEL IS CRACKED. / [01] REMOVED AND REPLACED AFT CARGO FLOOR PANEL REF BOEING 737 AMM 25-52-10.SDR SWAA2022080125463Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 312 TO BS 328 AT LEVEL RBL 31 FWD GALLEY AND LAV 2022-372861 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 312 TO BS 328 AT LEVEL RBL 31 FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG # 141A5SDR SWAA2022080125464Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AT LEVEL BL0 FWD GALLEY AND LAV 2022-372862 / [01] REPLACED WEB-INTERCOSTAL LOCATED ON FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AT LEVEL BL0 FWD GALLEY AND LAV IAW SRM B737-700 51-10-02 ITEM SDR SWAA2022080125460Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 312 TO BS 328 LBL 45.5 FWD GALLEY AND LAV 2022-372860 / [01] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 312 TO BS 328 LBL 45.5 FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DWG# 141A5400 REV SDR R61A2022072700472Crossbeam · corrodedCF III PAX CABIN AT FR 84 FROM RBL 12 TO RBL 33 CORRODED. R&R CROSSBEAM IAW SRM 51-43-03, 51-41-01.SDR AALA202207258095None · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR CREASE ANGLE AT BS 968 AND RBL 52. REPLACED CREASE ANGLE PER SRM 51-40-01.SDR AALA202207252734Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR INTERCOSTAL AT BS 957 AND LBL 50. REPLACED INTERCOSTAL PER SRM 51-40-01.SDR AALA202207180672Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON INTERCOSTAL LOCATED AT BS 962 AND LBL 50. REPLACED INTERCOSTAL PER AARD 51-00-05.SDR AALA202207184111Mount Bracket · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON L1 ENTRY DOOR AFT GIRT BAR MOUNT BRACKET LOCATED AT BS 344, LBL 52. REPLACED MOUNT PER SRM 51-40-02.SDR AALA202207184641Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON INTERCOSTAL FASTENER HOLE LOCATED AT BS 958 AND LBL 50. REPLACED INTERCOSTAL PER SRM 51-40-01.SDR CALA2022070401638Support Beam · corrodedB757-53-3-0572 R-4 DOOR THRESHOLD SUPPORT BEAM UPPER SIDE CORRODED APPROX 6 INCHES IN FRONT OF AFT DRAIN LINE CUTOUT. TRANSCRIBED FROM HAECO GSO NRC 9282803SDR AALA202207274234Web · corrodedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO DOOR THRESHOLD WEB HAS CORROSION LOCATED AT STA 827 AND RIGHT BUTT LINE 26. REMOVED AND REPLACED SERVICEABLE AFT CARGO DOOR THRESHOLD PER 53-00-53.SDR REXA2022072101646Floor Support · corrodedFLOOR BEAM AT FS 1004.00 TO FS 1088.00 LBL 27.00 CORRODED REMOVED CORRODED FLOOR BEAM AND REPLACED WITH NEW FLOOR BEAMSDR FDEA202207021668Web · crackedCABIN - STATION 1250.75 TO STATION 1256.75 R3 DOOR CUT OUT FORWARD UPPER JAMB WEB BOX FOUND CRACKED. CABIN AT STATION 1250.75 TO STATION 1256.75 R3 DOOR CUTOUT FORWARD UPPER JAMB WEB BOX , CRACKED AREA REPAIRED AS PER E.A.#: 1-5310-T0369327 PART 1 , TITLE SDR FDEA202207021671Floor Support · corrodedCABIN - RIGHT HAND STATION 2003 X = - 22 FLOOR SUPPORT FOUND CORRODED. CABIN - AT RIGHT HAND FLOOR SUPPORT STATION 2003 , X = - 22 CORROSION EVALUATED , FOUND EXFOLIATED AND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 REPAIR GENERAL. CORRODED FLOOR SUSDR FDEA202207021670Floor Support · corrodedAFT CARGO AND WASTE TANK COMPARTMENT STATION 1990 TO STATION 2000 , X - 25 CEILING FLOOR SUPPORT FOUND WITH CORROSION. AFT CARGO AND WASTE TANK COMPARTMENT CEILING , AT FLOOR SUPPORT STATION 1990 TO STATION 2000 , X = - 25 CORROSION EVALUATED FOUND EXFOLIASDR FDEA202207021669Floor Support · corrodedLOWER AFT CARGO COMPARTMENT BETWEEN STATION 1897 AND STATION 1925 X - 57 CEILING FLOOR SUPPORT FOUND WITH CORROSION. LOWER AFT CARGO COMPARTMENT CEILING , AT FLOOR SUPPORT STATION 1897 AND STATION 1925 , X = - 57 CORROSION EVALUATED , FOUND EXFOLIATED AND SDR AALA202207149667None · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND TRANSITION PANEL LOCATED FROM BS 500A TO BS 500I, AT S25R. REPLACED TRANSITION PANEL PER SRM 51-40-02.SDR ASAA2022070139444Web · corrodedMAIN CABIN AFT FLOOR DECK PLATE STA 1016 AND LBL 34 HAS CORROSION AT GALLEY FITTING. GROUNDED - YES. REMOVED CORROSION ORIG .050, REMAIN, .042, LOSS OF .008,FOUND OUT OF LIMITS IAW B737-800 SRM 53-70-51.REMVOED AND REPLACED WEB IAW BAC DWG 147A5700 AND B737-80SDR ASAA2022070139341Floorbeam · corrodedMAIN CABIN AFT FLOORBEAM AT STA987, FLOORBEAM HAS MULTABLE SPOTS OF CORROSION ALONG LENGTH. GROUNDED - YES. REMOVED AND REINSTALLED 5EA INTERCOSTAL, 4EA ANGLES AND WEBS STA 986-1068,REMOVED T-CAP FROM STA 987, FABBED ,LOCATED, DRILLED AND INSTALLED NEW T-CAP, SDR SWAA2022080424881Bulkhead · crackedCRACK BULKHEAD PANEL 142MW AT AFT CARGO COMPARTMENT 2022-354413 / [01] FABRICATED BULKHEAD PANEL 142MW AT AFT CARGO COMPARTMENT IAW B737-700 AMM 25-52-01-201-801 STEP 1 (C) (F) AND DWG 453A2510 REV:-. MATERIAL USED CONOLITE P/N A60SG4W 60144 PO: 2021 223548 1.SDR SWAA2022080124893Scuff Plate · crackedCRACK ON AFT CORNER SCUFF PLATE AT AFT CARGO COMPARTMENT 2022-372693 / [01] REPAIRED AFT CORNER SCUFF PLATE AT AFT CARGO COMPARTMENT IAW BOEING 737-700 SRM 53-60-15-2R-1 REPAIR 1 AND BAC 5975.SEE INDIVIDUAL SIGNOFFS BELOW.;[02] JOB TASK COMPLETED.SDR ASAA2022070139242Floor Panel · corrodedMAIN CABIN FLOOR STA 947 LBL 6, T CAP CORRODED DOT: N082 GROUNDED - YES. REMOVED CORROSION, ORIGINAL THICKNESS .180 PER B737-800 SRM 53-70-51 MAT LOSS .019, AREA NEW THICKNESS .171, AREA OUT OF LIMTIS PER B737-800 SRM 53-70-51 COMPLETED REPAIR PER B737-800 SRMSDR ASAA2022070139241Intercostal · corrodedMAIN CABIN FLOOR AT STA 947 TO STA 967, LBL25, INTERCASTAL HAS CORROSION AT FASTENER HOLE.DOT: N090 GROUNDED - YES. REMOVED CORROSION FROM INTERCOSTAL @ STA967 TO ST967 LBL 25. ORIGINAL THICKNESS .090", REMAINING .075 LOSS OF .015 FOUND OUT OF LIMITS IAW B737 SDR ASAA2022070139225Web · corrodedAFT CARGO DOOR CUTOUT - THRESHOLD SKIN @ DOOR SILL FROM FRAME 787-847 -EARLY SIGNS OF CORROSION.ALSO TO HAVE SCRIBE LINES, SCRATCHES AND BARE METAL AREAS ALONG ITS LENGTH.RED MARKED. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO DOOR CUTOUT THRESHOLD SKIN FROSDR ASAA2022070139224Floor Panel · delaminatedFWD WET AREA FLOOR PNL 145 PN:141A5810-236 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED DAMAGE ON FWD WET AREA PNL 145 P/N 141A5810-236 WITH FIBERGLASS DOUBLER WET LAY UP REPAIR IAW B737-800 SRM 53-00-50-2R-1.SDR ASAA2022070139223Floor Panel · delaminatedFWD WET AREA FLOOR PNL 100 PN:141A5810-454 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED DAMAGE TO FLOOR PNL P/N 141A5810 WITH FIBERGLASS DOUBLER WET LAY UP REPAIR IAW B737-800 SRM 53-00-50-2R-1.SDR ASAA2022070139222Floor Panel · delaminatedFWD WET AREA FLOOR PNL 200 PN:141A5810-121 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR TO FWD WET AREA FLOOR PANEL 200 P/N 141A5810-121 IAW B737-800 SRM 53-00-50-2R-0.SDR ASAA2022070139221Floor Panel · delaminatedFWD WET AREA FLOOR PNL 260 PN:141A5810-189 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED FWD WET AREA FLOOR PNL PN 141A5810-189 DAMAGE WITH FIBERGLASS DOUBLER REPAIR WET LAY UP IAW B737-800 SRM 53-00-50-2R-1.SDR ASAA2022070139220Floor Panel · delaminatedFWD WET AREA FLOOR PNL 160 PN:141A5810-155 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED DAMAGE TO FLOOR PNL 141A5810-155 WITH FIBERGLASS DOUBLER WET LAY UP REPAIR IAW B737-800 SRM 53-00-50-2R-1.SDR ASAA2022070139219Floor Panel · delaminatedFWD WET AREA FLOOR PNL 60 PN: 141A5810-175 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED FWD WET AREA FLOOR PNL PN: 141A5810-175 DAMAGES IAW B737-800 SRM 53-00-50-2R.SDR ASAA2022070139218Floor Panel · delaminatedAFT WET AREA FLOOR PNL 170 PN:147A5810-136 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR OF AFT WET AREA FLOOR PANEL 147A5810-136 IAW ASA B737-800 SRM SRM 53-00-50-2R-1.SDR ASAA2022070139217Floor Panel · delaminatedAFT WET AREA FLOOR PNL 305 PN:147A5810-27 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED DAMAGE TO FLOOR PANEL P/N 147A5810-27 WITH FIBERGLASS DOUBLER LAY UP REPAIR IAW B737-800 SRM 53-00-50-2R-1.SDR ASAA2022070139216Floor Panel · delaminatedAFT WET AREA FLOOR PNL 335 PN:147A5810-28 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. REPAIRED AFT WET AREA FLOOR PNL 335 P/N 147A5810-28 DAMAGE WITH FIBERGLASS DOUBLER REPAIR WET LAY UP IAW B737-800 SRM 53-00-50-2R-1.SDR ASAA2022070139215Floor Panel · delaminatedAFT WET AREA FLOOR PNL 245 PN:147A5810-137 DAMAGED AND REQ REPLACEMENT. GROUNDED - YES. REPAIRED AFT WET AREA FLOOR PANEL 245 PN: 147A5810-137 DAMAGES IAW B737-800 SRM 53-00-50-2R.SDR ASAA2022070139214Floor Panel · delaminatedAFT WET AREA FLOOR PNL 145 PN:147A5810-123 DAMAGED AND REQ. REPLACEMENT. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR OF AFT WET AREA FLOOR PANEL P/N 147A5810-123 IAW ASA B737-800 SRM 53-00-50-2R REPAIR 1.SDR SWAA2022072524858Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 22 BS 727J+5; BS 727J+10; BS 747+6; BS 747+10; BS 747+14; BS 747+18; BS 767+2; BS 767+6; BS 767+14; BS 767+18. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+6' RESDR SWAA2022072524853Threshold · corrodedCORROSION ON AFT CARGO BAY THRESHOLD AT RBL26 BS 787+16-807; RBL26 BS 807+5; RBL26 BS 807+7-10; RBL26 BS 807+14-18; RBL26 BS 827+4; RBL26 BS 827+6; RBL26 BS 827+9; RBL26 BS 827+12; RBL21 BS 827+19. CORROSION ON AFT CARGO BAY THRESHOLD AT RBL 26 BS 787+16-807 RSDR R61A2022072000454Gusset · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 RH GUSSET AT FR90 FOUND CORRODED. REPLACED GUSSET PN 170-60259-001 IAW SRM 51-41-02. AC RETURNED TO SERVICESDR R61A2022072000452Shear Tie · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 FUSE MID SHEAR PANEL AT FR 87-88 FOUND CORRODED. REPLACED SHEAR PANEL PN 170-65928-001 IAW SRM 51-42-01, 51-43-03. AC RETURNED TO SERVICESDR R61A2022072000451Shear Tie · corrodedWHILE AC WAS IN FOR HVY CK FOUNDCF3 FUSE 3 RH SHEAR PANEL AT FR 87-88 FOUND CORRODED. REPLACED SHEAR PANEL PN 170-91919-001 IAW SRM 51-42-01, 51-42-02, 51-43-01. AC REMAINS IN YQG FOR COMPLETIONSDR AALA202207187677Shield · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON SHIELD LOCATED AT STA 767-790. AND STR 25. REMOVED AND REPLACED SHIELD PER SRM 51-40-02.SDR AALA202207182950Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT LEFT HAND TRANSITION PANEL LOCATED FROM BS 500A TO BS 500I AT S26L. REPLACED TRANSITION PANEL PER SRM 51-40-02.SDR R61A2022071600443Panel · corrodedFWD SECTION R/H SIDE SILL PNL BETWEEN FR 12-14 CORRODED. R&R IAW EMB 170/175 SRM 51-41-02 AND 51-43-02.SDR R61A2022071500438Shear Panel · corrodedCNTR FUSE III MID SHEAR PNL AT FR 87-88 CORRODED. R&R IAW SRM 51-42-01 AND 51-43-03.SDR R61A2022071500437Shear Panel · corrodedCNTR FUSE III R/H SHEAR PNL AT FR 87-88 CORRODED . R&R IAW SRM 51-42-01, 51-42-02 AND 51-43-01.SDR R61A2022071500434Gusset · corrodedCNTR FUSE III R/H GUSSET AT FR 90 CORRODED. R&R IAW SRM 51-41-02SDR IPXA2022070183680Panel · damagedINSPECTION TYPE:A300AFT CARGO FLOOR PANEL 151SF EDGES DAMAGEREPAIR IAW SREO A300-5320-42722-F
Back to JASC 5320