SDR R61A2021090300688Floor Support · corrodedINTERNAL FUSELAGE, AFT GALLEY FLOOR SUPPORT STRUCTURE, L/H OB FLOOR BOARD SUPPORT ANGLE FR 88-90 FOUND CORRODED. REMOVED AND REPLACED IAW ERJ-175 SRM 51-42-01 AND 51-43-03.SDR R61A2021090300686Support Angle · corrodedINTERNAL FUSELAGE, AFT GALLEY FLOOR SUPPORT STRUCTURE, R/H OB FLOOR BOARD SUPPORT ANGLE FR 88-90 FOUND CORRODED. REMOVED AND REPLACED IAW ERJ-175 SRM 51-42-01 AND 51-43-03SDR R61A2021090300685Shear Panel · corrodedINTERNAL FUSELAGE, AFT GALLEY FLOOR SUPPORT STRUCTURE, CENTER SHEAR PANEL AT FR 87-88 BETWEEN L/H AND R/H SEAT TRACK FOUND CORRODED IN PREVIOUSLY BLENDED AREA. REMOVED AND REPLACED IAW ERJ-175 SRM 51-42-01.SDR R61A2021090300684Gusset · corrodedINTERNAL FUSELAGE, AFT GALLEY FLOOR STRUCTURE, GUSSET PLATE FOUND CORRODED ON FR 90 FLOOR BEAM R/H SIDE. REMOVED AND REPLACED IAW ERJ-175 SRM 51-41-02.SDR AALA202109019614Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=8.00 IN, W=8.00 IN, D=0.007 IN, ON FORWARD CARGO AREA RIGHT HAND TRANSITION PANEL LOCATED FROM STA 500A TO STA 500I AT RBL 26. REPLACED TRANSITION PANEL PER SRM 53-0053-2R-5.SDR AALA202109017486Shield · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=1.00 IN, W=1.25 IN, D=0.030 IN, ON FORWARD CARGO AREA RIGHT HAND SHIELD LOCATED FROM STA 492 TO STA 500A AT RBL 60. REPAIRED SHIELD PANEL PER SRM 51-10-02-OG.SDR SWIA2021083160634Angle · corrodedCORROSION INSIDE OF FUSELAGE ON ANGLE BETWEEN FRAMES 86 AND 87 AND STRINGERS 27R AND 28R. REMOVED AND REPLACED ANGLE BETWEEN FRAMES 86 AND 87 AND STRINGERS 27R AND 28R, INSIDE OF FUSELAGE REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR IPXA2021083173356Bracket · crackedINSPECTION TYPE:1CLT MLG W/W FWD LOWER BRAKE ACCUMULATOR SUPPORT BRACKET IS CRACKED.REMOVED AND REPLACED CRACKED LT MLG W/W FWD LOWER BRAKE ACCUMULATOR SUPPORT BRACKET IAW SRM 51-33-01. (MINOR)SDR IPXA2021083173355Stiffener · crackedINSPECTION TYPE:1CLT MLG W/W O/B AFT WALL 2ND VERTICAL STIFFENER FROM FWD IS CRACKED.REMOVED AND REPLACED CRACKED LT MLG W/W O/B AFT WALL 2ND VERTICAL STIFFENER FROM FWD IAW SRM 51-33-01. (MINOR)SDR DALA2021082304956Plate · corrodedSHIP 650 IN REF. TO NRC 00270: CORROSION OUT LIMITS ON SIDE PLATE RH BTW STA 654 TO STA 655, STA 662 TO STA 664 AND STA 680 TO STA 681 AT AFT CARGO COMP. CORRECTIVE ACTION: SUMMARY OF NRC 00950: CORROSION OUT LIMITS ON SIDE PLATE RH BTW STA 654 TO STA 655, STASDR DALA2021082304955Plate · corrodedSHIP 650 IN REF NRC 268: CORROSION ON SIDE PLATE LH BETWEEN STA 669 TO 670 UPPER SIDE AND LOWER FLANGE AT FWD CARGO COMPARTMENT(C1). CORRECTIVE ACTION: SUMMARY OF NRC 00951: CORROSION LEVEL 2 CORROSION ON SIDE PLATE LH BETWEEN STA 669 TO 670 UPPER SIDE AND LOWSDR DALA2021082004852Web · corrodedSHIP 3264 CORROSION FLOOR STRUCTURE WEB LOWER SURFACE AT LEVEL OF -Y1162 STR 23RH AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB PER A320 SRM 51-42-11 AND A320 SRM 51-72-11. (1917577)SDR DALA2021082004851Web · corrodedSHIP 3264 CORROSION FLOOR STRUCTURE WEB LOWER SURFACE AT LEVEL OF Y1162 STR 23 AT AFT GALLEY AREA AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB PER A320 SRM 51-42-11 AND A320 SRM 51-72-11. (1917571)SDR DALA2021082004848Floor Support · corrodedSHIP 3264 CORROSION FLOOR BEAM +Y1162.5 BTW FR68/69 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11 AND A320 SRM 51-42-11. (1917841)SDR DALA2021082004847Floor Support · corrodedSHIP 3264 CORROSION FLOOR BEAM -Y1162.5 BTW FR 68/69 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1917567)SDR CALA2021082001384Fitting · corrodedA3NB-53-3-6185 MAIN CABIN LH AFT DOOR SILL AT Y1732 FR68 FLOOR SUPPORT ANGLE AND FILLER CORRODED.(DOT38-28)() REMOVED REPAIR ANGLE IAW SR, 51-42-11. FABRICATED NEW REPAIR ANG LE AND FILLER TRAVELER #2111567542 FILLER MATERIAL ID:7075T6 371 " B/N3288578 LOCATORSDR CALA2021082001383Floor Support · damagedA3NB-53-3-6185 MAIN CABIN FLOOR SUPPORT Y765 FR68 UPPER SURFACE DAMAGED. (DOT 38-31)() REPLACED FLOOR BEAMP/N: D5347219220000 BATCH: 0002716632 IAW A32 0 SRM 51-42-11 AND SRM 51-72-11-911-001.SDR MASA20210819376Stiffener · crackedFS202.75 FORWARD STIFFENER AT BL 0.0 WL 100 CRACK. DISCOVERED DURING FS202 INSPECTION 12/04/2019. TEMPORARY REPAIR INCORPORATED UNDER MESA RO# CRJ7-53-4254 WO# 719028485. PERMANENT REPAIR ACCOMPLISHED BY INCORPORATION OF MESA EO CRJ7/9-53-4002 R2 WO# 721011366SDR SWAA2021092708634None · corrodedSUPPLEMENTAL INFORMATION: CORROSION AFT CARGO BAY TRACK TIE DOWN BS 727B +10 RBL 14 WL 156 ; / [01] REMOVED CORROSION ON AFT CARGO BAY TRACK TIE DOWN BS 727B+10 RBL 14 WL 156. AREA DIMENSIONS D=0.030' X LENGTH= 0.9' X W=0.8'. ORIGINAL THICKNESS 0.063'. REMAINISDR SWAA2021092708622Rail · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON RAIL AT AFT CARGO BAY BS773 LBL12 WL157. ; / ; [13] INSTALLED REPAIR PARTS ON RAIL AT AFT CARGO BAY BS773 LBL12 WL157.I.A.W. SRM53-00-53-2R-2; REPAIR 2;ALTERNATIVE 5; REPAIR INSTRUCTIONS P AND Q.; [14] VERIFIED INSTALLATISDR SWAA2021092708613Support · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS867- BS887 RBL21 WL168. ; / [11] INSTALLED NEW ACB FLOOR TO SIDEWALL SUPPORT BS 867 TO BS 887 RBL 21 WL 168 IAW SRM 51-40-02 AND DWG # 146A7500; [12] CORRECTED MEASUREMENTS; [1SDR SWAA2021092708603Channel · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON RAIL AT AFT CARGO BAY BS773 LBL8 WL157. ; / [01] REMOVED CORROSION ON AFT CARGO BAY RAIL AT BS 773 LBL 8 WL 157. AREA MEASUREMENTS D=0.010' X L=1.9' X W=0.8' ORIGINAL THICKNESS 0.063' REMAINING THICKNESS 0.053'. FOUND TO SDR SWAA2021092708631None · crackedSUPPLEMENTAL INFORMATION: AFT CARGO BAY TRACK TIE DOWN CRACKED BS 727E RBL 14 WL 156 ; / [01] UPON FURTHER EVALUATION OF CRACK L= 0.2' ORIGINAL MATERIAL THICKNESS 0.063'. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 PARAGRAPH 4B(1) DETAIL (A) AND (B).; [02]SDR SWAA2021092708628Support · corrodedSUPPLEMENTAL INFORMATION: CORROSION AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 797 TO BS 727 LBL 21 WL 156 ; / [01] REMOVED CORROSION IN AFT CARGO BAY FLOOR TO SIDE WALL ALL SUPPORT BS 797 TO BS 727 LBL 21 WL 156 IAW SRM 53-00-53-1A-2 L= 2.5 INCH ; W= 1.5; D= SDR SWAA2021092708605Tie Down · crackedSUPPLEMENTAL INFORMATION: AFT CARGO BAY TRACK TIE DOWN CRACKED BS 767 RBL 14 WL 156 ; / [01] UPON FURTHER EVALUATION OF CRACK L= 0.25' ORIGINAL MATERIAL THICKNESS 0.063'. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 PARAGRAPH 4B(1) DETAIL (A) AND (B).; [02]SDR SWAA2021092708602Channel · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON RAIL AT AFT CARGO BAY BS773 RBL8 WL157. ; / [01] REMOVED CORROSION ON AFT CARGO BAY RAIL AT BS 773 RBL 8 WL 157. AREA MEASUREMENTS D=0.012' X L=1.9' X W=0.8' ORIGINAL THICKNESS 0.063' REMAINING THICKNESS 0.051'. FOUND TO SDR SWAA2021092708597Strap · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON STRAP AT AFT CARGO BAY BS842 RBL18 WL162. ; / [01] REMOVED CORROSION ON STRAP AT AFT CARGO BAY BS842; RBL18; WL162; REWORKED AREA: L=1.3'; W=1'; D=0.020'; NOMINAL THICKNESS= 0.100'; WAS FOUND OUT OF LIMIT IAW SRM 51-10-02SDR SWAA2021092708596Track · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON TRACK AT AFT CARGO BAY BS867 - BS787 RBL13 WL163. ; / [01] REMOVED CORROSION ON AFT CARGO BAY TRACK AT BS 787 - BS867 RBL 13 WL 163. AREA MEASUREMENTS D=0.015' X L=1.9' X W=0.8' ORIGINAL THICKNESS 0.063' REMAINING THICKNESDR SWAA2021092708595None · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON TRACK TIEDOWN AT AFT CARGO BAY BS867 LBL3 WL165. ; / [01] REMOVED CORROSION ON AFT CARGO BAY TRACK TIE DOWN BS 867 LBL 3 WL 165. AREA DIMENSIONS D=0.042' X LENGTH= 1.8' X W=0.9'. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53SDR SWAA2021092708592None · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON FLOOR SPLICE SUPPORT TAB AT AFT CARGO BAY BS887 LBL8 WL169. ; / [01] CORROSION FOUND ON ACB FLOOR SPLICE SUPPORT TAB BS 887 LBL 8 WL 169 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENTSDR SWAA2021092708591Support Angle · crackedSUPPLEMENTAL INFORMATION: CRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT ACB BS918 RBL11 WL171. ; / [01] CRACK AT SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT ACB BS918 RBL11 WL171; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ON SRM PART WILL BE REPAIR BY RSDR SWAA2021092708590Support Angle · crackedSUPPLEMENTAL INFORMATION: CRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT ACB BS914 RBL11 WL171. ; / [01] CRACK AT SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT ACB BS914 RBL11 WL171; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ON SRM PART WILL BE REPAIR BY RSDR SWAA2021092708635None · crackedSUPPLEMENTAL INFORMATION: AFT CARGO BAY BULKHEAD SUPPORT PANEL CRACKED BS 727 RBL 5 WL 163 ; / [01] DAMAGE FOUND ON ACB BULKHEAD SUPPORT ANGLE BS 727 RBL 5 WL 163 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-1SDR SWAA2021092708621Rail · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON RAIL AT AFT CARGO BAY BS773 LBL3 WL157. ; / [01] REMOVED CORROSION ON AFT CARGO BAY RAIL BS 773 LBL3 WL 157. AREA DIMENSIONS D=0.010' X LENGTH=3' X W=0.9'. ORIGINAL THICKNESS 0.063' REMAINING THICKNESS 0.053'. FOUND TO BESDR SWAA2021092708619Shield · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON FWD SHIELD AT AFT CARGO BAY BS767- BS787 RBL21 WL157. ; / [01] REMOVED CORROSION ON FWD SHIELD AT ACB BS 767 - BS 787 RBL21 WL 157 IAW SRM 51-10-02-0G-0 AREA 20' X 1.2' X 0.012'. FOUND TOBE OUT OF LIMITS DUE TO NO ALLOWABSDR SWAA2021092708614Shield · corrodedSUPPLEMENTAL INFORMATION: CORROSION ON AFT SHIELD AT AFT CARGO BAY BS847 - BS867 RBL21 WL164. ; / [01] REMOVED CORROSION ON AFT SHIELD AT ACB BS 847 - BS 867 RBL 21 WL 164 IAW SRM 51-10-02-0G-0 AREA 20' X 1' X 0.010'. FOUND TOBE OUT OF LIMITS DUE TO NO ALLOWABSDR SWAA2021100808703Bracket · crackedSUPPLEMENTAL INFORMATION: CRACK BRACKET LOCATED BS 947.5 AT LEVEL STR 26L AT AFT CARGO COMPARTMENT ; 2021-369414 / [01] REMOVED BRACKET LOCATED BS 947.5 AT LEVEL STR 26L AT AFT CARGO COMPARTMENT.MEASURE OF CRACK IS:L=0.600.TOOL USED:CALIB PIE DE REY P/N:DIGITASDR REXA2021101100839Stringer · corrodedSTRINGER 20R CORRODED NEAR FS 319.70. REMOVED AND REPLACED STR 20R SEGMENT FROM FS280-FS 319.SDR SWAA2021092708611Sidewall Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS887 - BS907 RBL21 WL171. ; / ; [15] INSTALLED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM BS 887 - BS 947 RBL 21; WL 171 IAW SRM 51-40-02 AND DWG 147A7500; ID:003 AND REV:B.; [16] VERIFIED CORRECTIVE ASDR SWAA2021092708633Tie Down · corrodedCORROSION AFT CARGO BAY RAIL BS 727B +2 LBL 3 WL 156 ; / [01] REMOVED CORROSION ON AFT CARGO BAY TRACK TIE DOWN BS 727B+10 RBL 14 WL 156. AREA DIMENSIONS D=0.013' X LENGTH= 0.8' X W=0.6'. ORIGINAL THICKNESS 0.063'. REMAINING MATERIAL 0.050'. FOUND TO BE OUT OFSDR SWAA2021092708627Support · corrodedCORROSION AFT CARGO BAY TO SIDEWALL SUPPORT BS 767 TO BS 722B RBL 22 WL 156 ; / [01] REMOVED CORROSION AFT CARGO BAY TO SIDE WALL; SUPPORT BS 767 TO BS 722 RBL; 22 WL 156 MEASURES: L= 1' W= 1.400' W= 0.020' THIKNES REMANENT 0.020' TOOL USED ID: 1225 S/N: UNKNOSDR COEA2021091605816Threshold · corrodedWO 229094 NR 100007 HEAVY CHECK COE/MAJOR REPAIR: INTERNAL FUSELAGE, PAX THRESHOLD UPPER SURFACE HAS LEVEL 2 CORROSION FWD AND AFT OF FRAME 38. CORRECTIVE ACTION: REPAIRED PER SRAS DO/TS-3037/09...5270 DATED 9/10/2021, ISSUE B.SDR SWAA2021091508496Scuff Plate · crackedFWD CARGO AFT CORNER SCUFF PLATE CRACKED / FWD CARGO AFT CORNER SCUFF PLATE WELDED ON WORK ORDER 42581-1600-0001SDR SWAA2021091548682Intercostal · corrodedAFT CARGO STA 747-767 RBL 22 INTERCOSTAL CORRODED ON UPPER FASTENER HOLES ; / [01] REMOVED CORRODED INTERCOSTAL; [02] REMOVED AND REPLACED INTERCOSTAL; [03] INSPECTED AS REQUIRED; [04] REMOVED AND REPLACED INTERCOSTAL PER SRM 51-40-02; [05] VERIFY WORK ACCOMPLSDR AALA202109144482Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=1.00 IN, W=1.00 IN, D=0.005 IN, ON FLOOR WEB LOCATED AT STA 995 AND LBL 34. REPAIRED PER EA 330079.SDR AALA202109146685Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=0.125 IN, W=0.125 IN, D=0.03 IN, AROUND FASTENER HOLE ON FLOOR BOARD SUPPORT LOCATED AT STA 995 AND LBL 34. REPLACED SUPPORT PER SRM 51-40-02.SDR HNAA2021091300453Floor Support · corrodedPAX DOOR ENTRANCE FWD AND AFT FLOOR BOARD SUPPORT BRACKETS ARE CORRODED AROUND SCREW HOLES. REMOVED AND REPLACED PAX DOOR CUTOUT FWD AND AFT FLOOR SUPPORTS IAW EMB-145 SRM 51-40-02.SDR FDEA202108182278Stiffener · corrodedAFT CARGO COMPARTMENT R/H TUNNEL VERTICAL STIFFNER CORRODED UNDER NUT PLATE ON LOWER AREA AT STA 1841. (DOT 5) 0004092897 : REECE JR., RONALD S - 10-SEP-2021 17:49 WEB ASSEMBLY REPAIRED IAW SRM 53-00-01 GENERAL REPAIR #8 FIGURE 8 SHEETS 1-3 AND DRAWING ASDR AALA202109084575Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF LH TRANSITION PANEL IN FWD CARGO COMPARTMENT BETWEEN STA 506 AND STA 500I AT LBL 27, MEASURING L=3.0 IN, W=3.0 IN, D=0.015 IN. REPLACED TRANSITION PANEL WITH NEW IAW AARD 51-00-05-01, DRAWING 143A7500, AND SRM 53-00-5SDR SWAA2021090708354Gusset · crackedFCB GUSSET BS 500D STRINGER 21 L/H IS CRACKED ; / [01] EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM A
Back to JASC 5320