SDR SWAA2021072788183Support · corrodedFWD CARGO COMP DOOR CUTOUT AREA PANEL SUPPORT SHIELD SEVERAL SCREW HOLES CORRODED FROM BS 500A TO BS 500 RBL 25-R MKD 126-8. ; / [01] INSPECTED FWD CARGO R/H ZEE CHANNEL STA500A TO 500; CORROSION IS AROUND AND AT FASTENER HOLES; FOUND OUT OF LIMITS REF. B737-7SDR SWAA2021072788195Channel · corrodedCORROSION'' FWD CARGO COMP L/H ZEE CHANNEL SEVERAL FASTENER HOLES WITH EVIDENCE OF SURFACE CORROSION AT FRAME BS 500D TO BS 490 . ; / [01] CORROSION AROUND THE HOLES FOUND OUT OF LIMITS AT FWD CARGO COMPARTMENT ZEE CHANEL FLOOR SUPPORT BETWEEN FS 396-500D IN RSDR REXA2021072200512Post · corrodedVERTICAL POST AT FS 280.00 STGR 25R IS CORRODED AT THE BOTTOM. REMOVED AND INSTALLED NEW SERVICEABLE VERTICAL POST P/N: CC670-34180-8 AT F.S.280 BY REMOVING AND INSTALLING 1 BOLT. IAW CRJ 900 SRM 51-44-02-001-001-A01 AND 51-42-06-001-001-A01.SDR SWAA2021072188077Angle · corrodedCORROSION FWD CARGO COMP STA 500D FLOOR SUPPORT BETWEEN LEFT AND RIGHT ZEE ANGLE ; / [01] REMOVED SURFACE CORROSION AT FLOOR SUPPORT Z ANGLE ON FWD CARGO COMPONENT BETWEEN LEFT AND RIGHT REF B737-700 SRM 51-10-02-0G-0; [02] ORIG. MAT. : 0.071'; MAT. REMOVED : SDR R61A2021070800543Reinforcement · corrodedMID WING TO BODY FAIRING STRUCTURE AT FR 45, REINFORCEMENT U-RIB FOUND CORRODED. MID WING TO BODY FAIRING STRUCTURE AT FR 45, CORRODED REINFORCEMENT U-RIB , REMOVED AND REPLACED IAW EMBRAER 170-175 SRM 51-41-01.SDR SWAA2021070687796Scuff Plate · crackedAFT CARGO CENTER SCUFF PLATE CRACKED AT AFT CORNER ; / [01] RECIEVED CENTER SCUFF PLATE FROM BACKSHOP ON WORK ORDER 42401-1000-0001. CENTER SCUFF INSTALLED ON TTG8Q004E0V5; [02] VERIFIED ITEM 1<BR>AUDIT C/WSDR IPXA2021070671326Bracket · crackedINSPECTION TYPE:A300AFT CARGO LH Y1456 BRACKET A5341076521800 CRACKED.FABRICATED AND INSTALLED IAW SRM 53-15-18 AND 51-40-21.SDR IPXA2021070671323Bracket · crackedINSPECTION TYPE:A300AFT CARGO FWD BULKHEAD LH Y450 IB & OB BRACKET CRACKED 2 EACH.FABRICATED AND INSTALLED IAW SRM 53-15-18 AND 51-40-21.SDR SIMA20210625005Floor Support · corrodedSSI . L/H OMEGA BEAM IS CORRODED AT FRAME 59.(LEVEL 1 CORROSION) (MAJOR REPAIR)-C/A-COMPLETED REPAIR TO LH OMEGA BEAM AT FRAME 59 INBD SIDE IAW SRM 53-00-10, FIG 204.SDR SIMA20210625004Bracket · crackedBAGGAGE DOOR AFT UPPER BRACKET FOR DOOR LIFTING MECHANISM IS CRACKED.-C/A-COMPLETED REPAIR TO BAGGAGE DOOR AFT UPPER BRACKET FOR DOOR LIFTING MECHANISM IAW SRM 51-40-02.SDR SIMA20210625003Door Sill · corrodedCARGO DOOR SILL HAS AREAS OF CORROSION. (LEVEL1 CORROSION) MAJOR REPAIR-C/A-COMPLTED INSTALLATION OF CARGO DOOR SILL IAW SRM 51-40-02.SDR DALA2021062803502Floor Support · corrodedSHIP 3161 - CORROSION FLOOR BEAM +Y1162 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM LOC. BTW FR.68 TO FR.69 AT AFT GALLEY AREA AS PER A319 SRM 51-72 AND DWG. (1853139)SDR DALA2021062803497Floor Support · corrodedSHIP 3161 - CORROSION FLOOR BEAM -Y1292 LOCATED BTW FR 66 TO FR 68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1292 LOCATED BTW FR.66 TO FR.68 AT AFT GALLEY AREA AS PER A319 SRM 51-42 AND DWG.(1853132)SDR DALA2021062803496Floor Support · corrodedSHIP 3161 - CORROSION FLOOR BEAM -Y1162 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1162 LOCATED BTW FR.68 TO FR.69 AT AFT GALLEY AREA AS PER A319 SRM 51-42 AND DWG. (1853131)SDR DALA2021062803495Web · corrodedSHIP 3161 - CORROSION WEB FRAME 20 L1 AT LEVEL STGR 23L FWD GALLEY AREA. REPLACED WEB FRAME 20 AT LEVEL STR.23L FWD GALLEY AREA AS PER A319 SRM 51-42 AND DWG. (1853123)SDR DALA2021062803494Floor Support · corrodedSHIP 3161 - CORROSION FLOOR BEAM + Y1292 LOCATED BTW FR 66 TO FR 68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y1292 LOC BTW FR.66 AT AFT GALLEY AREA AS PER A319 SRM 51-72 AND DWG.(1853112)SDR DALA2021062703471Intercostal · corrodedSHIP 651 DURING INSPECTION MAINTENACE FOUND HIDDEN CORROSION LEVEL 2 ON INTERCOSTAL. INTERCOSTAL REPAIRED PER SRM 51-70-13. (LP 1853136)SDR DALA2021062703469Web · out of limitsSHIP 651 DURING INSPECTION MAINTENANCE FOUND OUT OF LIMITS THICKNESS MEASSUREMENT INSPECTION ON WEB STA 1634-1635. WEB STA 1634-1635 WAS REPAIRED PER SRM 51-70-13. (LP 1852858SDR DALA2021062503452Floor Support · damagedSHIP 663 IMPROPERLY HOLE ON FLOOR STRINGER ON STA 730 AND 2.90 LBL AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00330. STRINGER ON STA 730 TO 840 AND 2.90 LBL AT FWD CARGO COMPARTMENT WAS REPLACED PER B757-200 SRM. (1852476)SDR MASA20210625238Intercostal · corrodedFORWARD E&E BAY INTERCOSTAL CORRODED AT STGR 27L FS 349|R&R INTERCOSTAL IAW SRM 51-42-06SDR SWIA202160731Angle · corrodedPAX DOOR SILL ANGLE CORRODED ON FRONT AND BACK SIDES FS 310.00 TO FS 349.00 (C-CHECK RO 9/3/21) REMOVED CORRODED PAX DOOR LOWER SILL ANGLE AND INSTALLED NEW SERVICEABLE PART LAW CRJ-200 SRM 51-42-21, 51-42-06, AND 51-42-15 REVISION 38B - 25 NOV 2020. COMPSDR SWIA202160726Angle · corrodedCLIPS AT FS 280.00 STR 27 AND STR 25L ARE CORRODED (C-CHECK RO 9/3/21) REMOVED IB AND OB CLIPS FROM FS 280 STR 26L AND FOUND TO BE DIRT/DEBRIS ONLY. CLEANED DIRT/DEBRIS AND REINSTALLED IAW CRJ 200 SRM 51-24-06 AND 51-42-21. REMOVED AND REPLACED IB AND OB SDR REXA2021082400602Floor Support · corrodedFLOOR BEAM AT RBL 9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 1000.00 TO F.S. 1098.00 - REMOVED & REPLACED FLOORBEAM LBL9 AT FS 1000.00-1095.00 IAW EA CRJ953-11818. RESTORED SURFACE IAW CRJ900 SRM 51-25-00-001-001-A01.SDR REXA2021082400601Floor Support · corrodedFLOOR BEAM AT LBL9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 1000.00 TO F.S. 1098.00. - REMOVED VAPOR BARRIER ATTACHED TO FLOOR BEAM AT LBL9 FROM FS 1000 TO FS 1098 FOR ACCESS TO CORROSION. INSTALLED 12EA NEW NUTPLATES IAW CRJ 900 SRM 51-42-15-001-001-A01. PSDR SWIA202160469Stringer Clip · corrodedUPON REMOVAL FOUND STRINGER CLIP AT FS1031+2 STR18L TO HAVE CORROSION (C-CHECK RO 8/18/2021) REMOVED AND REPLACED STRINGER CLIP AT F.S. 1031+2 AT STGR 18L, REF CRJ 900 SRM 51-42-06-001-001-A01 AND BOMBARDIER DWG MM670-36023 REV B / COMPLIED WITH SKYWESTSDR SWIA2021081960454Stiffener · cracked*CRACK ON 909.00 LH WEB STIFFENER (C-CHECK RO 8/18/2021) COMPLIED REPAIR ON L/H SIDE FUSELAGE FAIRING SUPPORT STRUCTURE AT FS 909.0 PER BOMBARDIER REO 670-53-82-478 REV -A DATED 2014-11-12SDR SWIA2021081060228Intercostal · corrodedCORROSION PRESENT ON INTERCOSTAL BETWEEN FS581.00-FS597.00 AND STGR 23L-22L (C-CHECK RO 8/6/2021) BLENDED, EVALUATED: ORIGINAL THICKNESS- 0.080", REMAING THICKNESS- 0.069", MATERIAL LOSS- 0.011", MATERIAL LOSS ALLOWABLE- NONE. OUT OF LIMITS. REF CRJ700SDR SWAA2021080488334Channel · corrodedCORROSION ON AFT ENTRY DOOR MOP SILL BS 964-986 LBL 52 WL 208. ; / [01] REMOVED CORROSION ON AFT ENTRY DOOR MOPSILL STA 964-986; LBL 52; WL 208. MAX MATERIAL REMOVED WAS .015' 1' BY 1' FROM .080'. OUT OF LIMITS PER SRM 53-70-15-01-1; SRM 53-70-15-1A-1; SRM 51-SDR SWAA2021080488335Channel · corrodedCORROSION ON AFT SERVICE DOOR MOP SILL BS 960-986 RBL 52 WL 208. ; / [01] REMOVED CORROSION ON AFT SERVICE DOOR MOPSILL STA 960-986; RBL 52; WL 208. MAX MATERIAL REMOVED WAS .012' 1' BY 1' FROM .080'. OUT OF LIMITS PER SRM 53-70-15-01-1; SRM 53-70-15-1A-1; SRMSDR SWAA2021080287851Strap · corrodedCORROSION STRAP BTS BS 767 TO BS 787 AND BTW STR 25R TO STR 25L AT AFT CARGO COMPARTMENT ; 2021-295447 / [01] REPLACED STRAP LOC BS 767 TO BS 787 STR 25R TO STR 25L AT AFT CARGO COMPARTMENT. IAW B737-700 SRM 51-10-02.; [02] REPLACED STRAP LOC BS 767 TO BS 787 SDR SWAA2021080287853Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BS 690 RBL 24.5 INBARD LOWER SIDE CENTER SECTION ; 2021-295460 / [01] REPLACED SUPPORT ANGLE AND FASTENER LOCATED BS 690 RBL 24.5 INBOARD LOWER SIDE CENTER SECTION I.A.W. B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 111A6000 SHSDR SWAA2021072788153Web · corrodedFWD CARGO DOOR LOWER SILL WEB WITH EVIDENCE OF SURFACE CORROSION AROUND FASTENERS BETWEEN BS 460 AND BS 480 RBL-30 . MID 126-01 ; / [01] LOCATED AND DRILLED NEW WEB AS PER B737-700 SRM 51-40-05-0G-0.; [02] VERIFIED WORK PERFORMED; [03] OK TO TREAT AND PRIME; [SDR SWAA2021072788154Strap · corrodedFWD CARGO COMP FLOOR PANEL SUPPORT STRAP ABOVE STGR 26-R EVIDENCE OF SURFACE CORROSION AROUND FASTENER HOLE BS 439 RBL-22 . MKD 126-02 ; / [01] INSPECTED AREA; CORROSION IS IN AND AROUND THE FASTENER HOLES AREA; FOUND OUT OF LIMITS REF. B737-7 SRM 51-10-02-0G-SDR SWAA2021072788170Channel · corroded**CORROSION** AFT CARGO FLOOR STRUCTURE ZEE CHANNEL AT RBL-17 BETWEEN BSTA 747-767 WITH CORROSION ; / [01] REMOVED CORROSION AT AFT CARGO FLOOR STRUCTURE R/H ZEE CHANNEL AT RBL-17 BTW STA #747 TO STA #767 AS PER REFERENCE B737-700 SRM 51-10-02-0G-0;[06] LOCATESDR ASAA2021062435487Bracket · crackedRH WING MLG SUPPORT BEAM UPPER STABILIZER LINK FWD Z-ANGLE BRACKET AT AFT SPAR IS CRACKED. GROUNDED - YES. REMOVED CRACKED Z-ANGLE BRACKET / CLIP AND INSTALLED NEW Z-ANGLE BRACKET / CLIP IAW B737-700 SRM 51-40-02-0G-0 PARA 7.SDR SWAA2021072188158Channel · corrodedFWD CARGO COMP FLOOR PANEL SUPPORT ZEE CHANNEL SCREW HOLES WITH SURFACE CORROSION FROM BS 500D TO BS 500A RBL-25 MKD 126-07. ; / [01] INSPECTED FWD CARGO R/H ZEE CHANNEL STA500A TO 500D; CORROSION IS AROUND AND AT FASTENER HOLES; FOUND OUT OF LIMITS REF. B737-SDR SWAA2021071387311Floor Support · corrodedAFT CARGO INTERCOSTAL BS 887 RBL 21.5 HAS CORROSION ; / [01] REMOVED INTERCOSTAL; STA 867 TO STA 887; RBL 21.5 PER SRM 51-40-02.; [02] REMOVED CORROSION PER SRM 53-00-53-1A-2 AND FOUND TO BE OUT-OF-LIMITS PER SRM 53-00-53-1A-2.; [03] INSPECTED 2. MICHAEL BECK SDR SWAA2021071287488Web · crackedCRACK WEB - INTERCOSTAL LOCATED BETWEEN BS500A TO BS500B AND STR26R FWD CARGO COMPARTMENT ; 2021-282490 / [01] TOOL USED CALIPER P/N 700-113-10 S/N 0019289 DUE DATE 25-MAR-22; [02] TOOL USED PN/ NORTEC 600D; SN/ 200048001; DE DATE/ 24FEB22; [03] TOOL USED CALISDR SWAA2021071287487Web · crackedCRACK WEB - INTERCOSTAL LOCATED BETWEEN BS500 TO BS500A AND STR26L FWD CARGO COMPARTMENT ; 2021-282489 / [01] TOOL USED CALIPER P/N:700-113-10; S/N:0023244; DUE DATE: 28-SEP-21; [02] REPLACE WEB-INTERCOSTAL LOCATED BETWEEN BS500 TO BS500A AND STR26L FWD CARGO SDR SWAA2021071287489Support · crackedCRACK ANGLE - SUPPORT LOCATED BS500B FWD FACE AND STR26L FWD CARGO COMPARTMENT ; 2021-282491 / [01] TOOL USED CALIPER P/N:700-113-10; S/N:0023244; DUE DATE: 28-SEP-21; [02] REPLACED ANGLE SUPPORT AND FASTENERS LOCTED BS 500B FWD FACE AND STR. 26L FWD CARGO COMSDR R61A2021071000559Attach Fitting · corrodedCORROSION FOUND ON AFT WING TO BODY FAIRING ATTACHMENT LANDING, FRAME 78. AFT WING TO BODY FAIRING ATTACHMENT LANDING AT FR 78 REPLACED WITH NEW IAW E170 SRM 51-41-02, AND 51-41-01, 51-43-04SDR SWAA2021070687334Angle · crackedFWD CARGO COMPT. STA 520 LBL 25 Z-ANGLE HAS CRACK AT FASTENER HOLE DOT A-21-43 ; / [01] VERIFIED MATERIAL ID FOR REPAIR PARTS BAC1496-444-7075-T6 TAG# A18195 IAW SRM 53-00-53-2R-5 REPAIR 5; [02] CUTOUT DAMAGE SECTION OF Z-ANGLE AT BETWEEN STA.440 460 IAW SRM 5SDR AALA202107013820Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND IN COUNTER SINK HOLES ON FUEL PANEL 640HB LOCATED AT STA 13-14, STR 8-11. REPLACED FUEL PANEL 640HB PER SRM 57-27-11-283-002.SDR JJBA20210624039Support Bracket · crackedFRM SUPPORT BRACKET CRACKED IN AFT CARGO COMP. AT BULK HEAD UPPER SURFACE BETWEEN OIL ANNOIR, X=24389.5. REMOVED SHEAR CLIP IN AFT CARGO COMP. AFT BULK HEAD. FABRICATED SUPPORT BRACKET, SHEAR CLIP MAT USED 7075 T6 .032". INSTALLED SHEAR CLIP ON AFT CARGO AT BUSDR DALA2021062503464Web · corroded(LOG 1851287) DURING INSPECTION CORROSION WAS FOUND AT MAIN LOWER SILL WEB FWD CARGO. MAIN LOWER SILL WEB AT FWD CARGO COMPARTMENT WAS REPLACED PER DWG 143A8120 AND B737-800 SRM 51-40-02.SDR CALA2021062500960Floor Support · corrodedA3NB-25-3-6221 DOT 42-026 AFT CABIN FLOOR SUPPORT BEAM CORREDED FR66 Y1292 LAV MOUNT AREA (). REPLACED AFT CABIN FLOOR SUPPORT BEAM FR66 Y1292 IAW SRM 51-42-1 1.SDR CALA2021062500956Floor Support · corroded(A3NB-53-3-6185O) MAIN CABIN, AFT CABIN FR66-67 Y254-765 FLOOR B EAM 24IN. FROM CENTERLINE HAS CORROSION ON UPPER SURFACE. REMOVED AND REPLACED FLOOR BEAM P/N D5347209400800, BATCH:000271 6526 IAW A319 SRM 51-42-11.SDR CALA2021062500953Floor Support · corroded(A3NB-53-3-6185) MAIN CABIN, AFT CABIN FR68-67 Y765 FLOOR BEAM H AS CORROSION ON TOP SURFACE. DOT 102-131 (). REPLACED FLOOR BEAM WITH NEW FLOOR BEAM PN#D5347219220000 IAW A3 19 SRM 51-42-11. FR 67-68 Y765.SDR CALA2021062500952Floor Support · corroded(A3NB-53-3-6040) DOT 42-032 FWD CABIN FLOOR SUPPORT BEAM HAVE CO RROSION FR20 TO FR 21 -Y765() REMOVED OLD AND INSTALLED NEW FLOOR BEAM P/N D5311281400200 BATC H 003786788, IAW A319, SRM 51-42-11 ATTACHED FORM 44-0008.SDR CALA2021062500951Floor Support · corroded(A3NB-53-3-6038) MAIN CABIN FLOOR STRUCTURE Y503 HAS CORROSION A ND SCRATCHES AROUND FASTENER HOLES C-15-16 P/N. REPLACED FLOOR BEAM P/N:D5311282600200 BATCH:0003804422 IAW A319 SRM 51-72-11-911-001. ATTACHED FORM 44-0008.
Back to JASC 5320