JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2021062500950Floor Support · corroded(A3NB-53-3-6038) MAIN CABIN FLOOR STRUCTURE Y765 HAS CORROSION A ND SCRATCHES AROUND FASTENER HOLES C-12-16 P/N D5311281300251. D OT 102-118 (). REMOVED AND REPLACED FLOOR BEAM WITH NEW FLOOR BEAM P/N D5311281 400200, BATCH 003786788. IAW A319 SRM 51-42-11, FRSDR SWIA2021090360702Strap · damagedDISCREPANCY TRANSFERED FROM CAMP CARD 22928499: JOB# 910139123 OP: 2 REMOVE AND REPLACE LOWER LH STRAP AT F.S 202.75 REF: DWG: CC670-34125 PER STEP1 OF REPAIR INSTRUCTION OF MHIRJ REO 670-53-11-1704 REV: -- DATE: 2021-06-17 (C-CHECK RO 8/31/21) REPAIRED LOSDR SWIA2021081960377Door Sill · corrodedAFT BAGGAGE-BAY DOOR SILL HAS EVIDENCE OF CORROSION IN MULIPLE LOCATIONS. MARKED (C-CHECK RO 8/18/2021) REMOVED AND REPLACED AFT BAGGAGE-BAY DOOR SILL PER CRJ700 SRMS 51-42-06-001-001-A01, 51-42-13-001-001-A01, 51-42-21-001-001-A01 & DWG NO MM670-35085 SDR SWAA2021080487616Floor Support · crackedCRACKED FLOOR SUPPORT BS 344-360 LBL 11 WL 208. ; / [01] REMOVED CRACKED FLOOR SUPPORT BS344-360 LBL11 WL208 PER SRM 51-40-02-0G-0.; [02] LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-05-0G-0 AND DWG 141A5410.; [03] UPDATED MEASUREMENT TABLE AND REQUEST SDR SWAA2021080486991Floor Support · corrodedCORROSION ** AFT CARGO COMPARTMENT L/H SIDE FLOOR SUPPORT Z CHANNEL FROM STA 727B TO STA 847 S-25L ; / [01] REMOVED CORROSION AT AFT CARGO COMPARTMENT L/H SIDE FLOOR SUPPORT Z CHANNEL FROM STA. 727B TO STA. 847 S-25L PER B737-700 SRM 51-10-02-0G-0; [02] VERIFISDR SWAA2021080487601Support · corrodedBS 500B-500C RBL24.5 WL157 FLOOR TO SIDEWALL SUPPORT IS CORRODED. / [01] EVALUATED CORROSION FROM BS 500B-500C FOUND DEEPEST LOCATION AT BS 500B+10 FOUND 0.015 REMOVED FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566A SSDR SWAA2021080487613Support · corrodedCORROSION ON FLOOR TO SIDE WALL SUPPORT BS 767-793; RBL 21; WL 156 ; / [01] EVALUATED CORROSION FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORROSION TO BE OUT OF LIMITS DUE TO NO ALLOWABLSDR SWAA2021080487611Support · corrodedCORROSION ON FLOOR TO SIDE WALL SUPPORT BS 727+4-847; LBL21; WL 156 ; / EVALUATED CORROSION FROM BS 727+4 TO 847 FOUND DEEPEST LOCATION AT BS 787 FOUND 0.015 REMOVED FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566A S/NSDR SWAA2021080487610Web · corrodedFORWARD CARGO BAY BS440-494 RBL 25 WL157 SUBWEB THRESHOLD IS CORRODED. / [01] EVALUATED CORROSION FROM BS 440-494 FOUND DEEPEST LOCATION AT BS 460 FOUND 0.015 REMOVED FROM ORIG 0.045 FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-1 USING DEPTH GAUGE P/N ATS400 SDR SWAA2021080487609Support · corrodedBS500D LBL24.5-RBL24.5 WL157 AFT BULKHEAD PANEL SUPPORT IS CORRODED. / [01] EVALUATED CORROSION FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORROSION TO BE OUT OF LIMITS DUE TO NO ALLOWABLSDR SWAA2021080487608Support · corrodedBS500-500C LBL24.5 WL157 FLOOR TO SIDEWALL SUPPORT IS CORRODED. / [01] EVALUATED CORROSION FROM BS 500-500C FOUND DEEPEST LOCATION AT BS 500B FOUND 0.015 REMOVED FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566A S/N UNKSDR SWAA2021080487607Support · corrodedCORROSION ON FLOOR TO SIDE WALL SUPPORT BS 727+4-767 RBL 21; WL 156 ; / [01] EVALUATED CORROSION FROM BS 727+4 TO 767 FOUND DEEPEST LOCATION AT BS 747 FOUND 0.015 REMOVED FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566SDR SWAA2021080487606Shield · corrodedBS 420-440 RBL24.5 WL157 FLOOR TO SIDEWALL SHIELD IS CORRODED. / [01] EVALUATED CORROSION FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORROSION TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMASDR SWAA2021080487605Shield · corrodedBS 494-500A RBL24.5 WL157 FLOOR TO SIDEWALL SHIELD IS CORRODED. / [01] EVALUATED CORROSION FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORROSION TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMSDR SWAA2021080487617Support Angle · corrodedCORROSION ON FWD ENTRY DOOR I/B THRESHOLD SUPPORT ANGLE BS 316 -338 LBL 60 WL 208. ; / [01] REMOVED CORROSION ON FWD ENTRY DOOR I/B SUPPORT ANGLE STA 316-338; LBL 60; WL 208. MAX MATERIAL REMOVED WAS .014'; 22' BY 1' FROM .080' OUT OF LIMITS PER SRM 51-10-02-0SDR SWAA2021072787536Floor Support · crackedINTEROSTAL BETWEEN FSTA 328 AND STA 312 LBL 46'HOLE CRACKED ; / [01] INSTALLED EWIS PROTECTION STA.312 LBL 46; REF.B737-7 AMM 20-60-07-913-801; [02] VERIFIED EWIS INSTALLATION; [03] LOCATED AND DRILLED INTERCOSTAL REF. B737-7 SRM 51-40-05-0G-0; DRW #141A5400; SDR SWAA2021072787537Floor Support · crackedINTERCOSTAL BETWEEN FSTA 344 TO FSTA 360 BL 0 HOLE CRACKED. ; / [01] INSTALLED EWIS PROTECTION REF. B737-7 AMM 20-60-07-913-801; [02] LOCATED AND DRILLED INTERCOSTAL REF. B737-7 SRM<BR>51-40-05-0G-0; [03] TREATED AND PRIMEDHOLES REF. B737-7 SRM 51-20-01-0G-0; SDR SWAA2021072787538Floor Support · crackedINTERCOSTAL BETWEEN FSTA 344 TO FSTA 360 LBL 12' HOLE CRACKED. ; / [01] INSTALLED EWIS PROTECTION REF. B737-7 AMM 20-60-07-913-801; [02] VERIFIED EWIS PROTECTION INSTALLATION; [03] REMOVED FASTENERS AT INTERCOSTAL BETWEEN FLOOR BEAM FS 344-360 LBL 12'IN REF B7SDR SWAA2021072787539Floor Support · crackedINTERCOSTAL BETWEEN FSTA 344 TO FSTA 360 RBL 12' HAS HOLE CRACKED. ; / [01] INSTALLED EWIS PROTECTION FS344-360; RBL12; REF. B737-7 AMM 20-60-07-913-801; [02] REMOVED INTERCOSTAL AT MAIN CABIN FLOOR STRUCTURE BETWEEN FS 344-360 RBL 12' IN REF B737-700 SRM 52-4SDR ASAA2021062335376Floor Panel · delaminated[PARTS RACK] FWD CARGO COMPARTMENT FLOOR PANEL 131CF HAS 2 EA TEMPORARY REPAIRS. PERMANENT REPAIR REQUIRED. GROUNDED - YES. PERFORMED PERMANENT REPAIR ON FWD CARGO COMPARTMENT FLOOR PANEL 131CF AT 2EA. AREAS IAW A320-214 SRM; 53-02-00-300-004 PARA. 2.A; A/C: NSDR ASAA2021062335375Floor Panel · delaminated[PARTS RACK] FWD CARGO COM0PARTMENT FLOOR PANEL 131BF HAS 2 EA TEMPORARY REPAIRS, PERMANENT REPAIR REQUIRED. GROUNDED - YES. REPAIRED FWD CARGO COMPARTMENT FLOOR PANEL 131BF AT 3EA. AREAS, PERFORMED PERMANENT REPAIRS IAW A320-214 SRM: 53-02-00-300-004 PARA. 2.SDR IPXA2021071371622Stiffener · corrodedINSPECTION TYPE:2CAFT AVI COMPT VERTICAL STIFFENER AT STA 470 BULKHEAD BELOW SERVICE DOOR IS CORRODED.REMOVED AND REPLACED CORRODED AFT AVI COMPT VERTICAL STIFFENER AT STA 470 BULKHEAD BELOW SERVICE DOOR IAW SRM 51-33-01. (MINOR)SDR R61A2021071000557Shear Plate · corrodedCORROSION FOUND ON CENTER FUSELAGE III, FLOOR SUPPORT STRUCTURE MID SHEAR PANEL AT FR 87-88. CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE MID SHEAR PANEL AT FR 87-88 HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER SRM 51-42-01SDR R61A2021070800544Gusset · corrodedCORROSION FOUND ON CENTER FUSELAGE III FLOOR STRUCTURE MID GUSSET PLATE AT FR 90. CENTER FUSELAGE III FLOOR STRUCTURE MID GUSSET PLATE AT FR 90 HAS BEEN REPLACED WITH NEW AND REINSTALLED IAW EMBRAER 170/175 SRM 51-41-02SDR R61A2021070800542Support · corrodedCORROSION FOUND ON CENTER FUSELAGE III FLOOR SUPPORT R/H PROFILE AT FR 89. CENTER FUSELAGE III FLOOR SUPPORT R/H PROFILE AT FR 89 HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER 170-175 SRM 51-42-01SDR SWAA2021062887534Floor Support · crackedINTERCOSTAL BETWEEN FS 328 AND 312 RBL 34' HOLE CRACKED. ; / [01] INSTALLED EWIS PROTECTION AT FS 312-328; RBL34' AREA; REF. B737-7 AMM 20-60-07-913-801; [02] VERIFIED EWIS INSTALLATION; [03] REMOVED INTERCOSTAL; LOCATED AND DRILLED NEW INTERCOSTAL FS 312-328;SDR DALA2021062803493Shear Plate · corrodedSHIP 3161 - CORROSION SHEAR PLATE LOCATED BTW FR 69 TO FR 70 AND STR 23LH AND 23RH AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SHEAR PLATE (2E/A), SUPPORT WEB (2E/A), BRACKETS (2E/A) LOCATED BTW FR.69 TO FR.70 AND STR.23LH AND 23RH AT AFT GALLEY AREA AS PESDR DALA2021062403425Stiffener · crackedSHIP 3238 CRACK FOUND ON CWB FRONT SPAR VERTICAL STRINGER POSITION 2 Y765 ZONE 1 AT FR 36. CORRECTIVE ACTION: REPAIRED PER ER/A 591742-14AD REV.0, REV.1 AND ER/A 591742-14AD REV. ORIGINAL. (1850857)SDR DALA2021062403423Stiffener · crackedSHIP 3238 CRACK FOUND ON CWB FRONT SPAR VERTICAL STRINGER POSITION 3 Y254 ZONE 2 AT FR 36. CORRECTIVE ACTION: REPAIRED PER ER/A 591742-14AD PRI REV.0, REV.1 AND ER/A 591742-14AD REV. ORIGINAL. (1850720)SDR DALA2021062403421Stiffener · crackedSHIP 3238 CRACK FOUND ON CWB FRONT SPAR VERTICAL STRINGER POSITION 3 Y254 ZONE 1 AT FR 36. CORRECTIVE ACTION: REPAIRED PER ER/A 591742-14AD REV 0, REV 1, AND ER/A 591742-14AD REV. ORIGINAL (1850715)SDR DALA2021062403420Stiffener · crackedSHIP 3238 CRACK FOUND ON CWB FRONT SPAR VERTICAL STRINGER POSITION 4 -Y254 ZONE 2 AT FR 36. CORRECTIVE ACTION: REPAIRED PER ER/A 591742-14AD AND PRI REV.0, REV.1 AND ER/A 591742-14AD REV. ORIGINAL. (1850713)SDR DALA2021062403419Stiffener · crackedSHIP 3238 CRACK FOUND ON CWB FRONT SPAR VERTICAL STRINGER POSITION 5 -Y765 ZONE 2 AT FR 36. CORRECTIVE ACTION: REPAIRED PER ER/A 591742-14AD REV.0, REV.1 AND 591742-14AD REV. ORIGINAL. (1850709)SDR SWIA202160466Support · corrodedPAX DOOR FWD ANGLE SUPPORT HAS EXFOLIATED CORROSION (C-CHECK RO 8/18/2021) REMOVED AND REPLACED WITH NEW PAX DOOR FWD ANGLE SUPPORT REF BOMBARDIER DWG 601R31702 REV. N AND CRJ 900 SRM 51-42-06-001-001-A01. LEAK CHECK GOOD / COMPLIED WITH SKYWEST FORM M-SDR SWAA2021080486957Support Web · corrodedCORROSION ** AFT WET AREA GALLEY FLOOR SUPPORT WEB AT STA 1016 RBL 7 TO RBL 26 MKD DOTS ; / [01] REMOVED FLOOR SUPPORT WEB AT AFT CABIN WET AREA STA 1016 R/H PER REF B737-700 SRM 51-40-02-0G-0.; [02] FOUND HOLE AT CORROSION AREA ON MAIN CABIN R/H FLOOR SUPPORTSDR SWAA2021080487205Support Channel · corrodedCORROSION FOUND ON FLIGHT DECK FLOOR INTERCOSTAL SUPPORT CHANNEL BETWEEN BS 259.5 AND BS 270; BL 0; WL 208 ; / [01] VERIFIED APPLICABILITY PER SRM 53-10-51-1A-1 PAR 4.B(2)(A) FIGURE 105/ALLOWABLE DAMAGE 1 DETAIL E; [02] REMOVED CORROSION ON SUPPORT CHANNEL BS2SDR SWAA2021080486948Floor Support · corrodedCORROSION. ** AFT WET AREA FLOOR BEAM UPPER SURFACE RBL 9 STA 986 TO STA 1006 MKD DOTSB ; / [01] STARED REMOVING CORROSION AT FLOOR SUPPORT UPPER SURFACE (INTERCOSTAL) FOUND EXFOLIATION THROUGHOUT MORE THAN 50% OF MATERIAL .FOUND TO BE OUT LIMITS REF B737-700 SDR SWAA2021080486971Clevis · corrodedCORROSION ** AT O/H BIN SUPPORT BRACKET CLEVIS @ STA 887 BETWEEN S-5 R & 6R MKD DOT ; / [01] REMOVED AND REPLACED FITTING IAW. B-737-700 SRM 51-40-02-0G-0; [02] FINAL INSPECTION; FITTING REPLACEMENT.SDR SWAA2021071587032Intercostal · crackedCRACKED INTERCOSTAL COMMON TO FLOOR PANEL 241AF BS 380-400 BL 0 WL 208 ; / [01] DAMAGE EVALUATION; NO ENTRIES FOUND ON SRM FOR CRACKS ON INTERCOSTAL BS380-400 BL0 WL208 PART TO BE REPLACED I.A.W SRM 51-10-02-0G-0 PAR 9.C; [02] REMOVED INTERCOSTAL BS 380-400; WSDR SWAA2021071587033Intercostal · crackedCRACKED INTERCOSTAL COMMON TO FLOOR PANEL 231KF BS 500D-520 BL 0 WL 208 ; / [01] DAMAGE EVALUATION; NO ENTRIES FOUND ON SRM FOR CRACKS ON INTERCOSTAL BS500D-BS520 BL0 WL208 PART TO BE REPLACED I.A.W SRM 51-10-02-0G-0 PAR 9.C; [02] REMOVED INTERCOSTAL BS500D-BSSDR REXA2021071300498Seat Track · corrodedFLOOR SEAT TRACK AT RBL9 FROM FS 349 TO FS 485 IS CORRODED. REMOVED AND REPLACED FLOOR SEAT TRACK AT RBL 9 FROM FS 349 TO FS 348 IAW CRJ 900 AMM 53-00-49-400-801-A12 AND SRM 53-00-49-201-002-A01.SDR SWAA2021071386876Angle · corrodedCORROSION AFT CARGO R/H TRANSITION ANGLE BS727E+6 TO BS767 ; / [01] TRANSITION ANGLE BEING REPLACED FROM BS 727 - 767 ON TTG8Q005JK1X.; [02] 1. TRANSITION ANGLE BEING REPLACED FROM BS 727 - 767 ON TTG8Q005JK1X. C/W INSPECTION.; [03] FAULT COMPLETE.SDR SWAA2021071286786Support · damagedFLOOR TO SIDEWALL SUPPORT ELONGATED FASTENER HOLE. ; FORWARD CARGO BAY; FLOOR TO SIDEWALL SUPPORT HAS ELONGATED FASTENER HOLE AT BS 500A+9.5; LBL20; WL156. / [01] EVALUATED ELONGATED FASTENER HOLE ON FCB FLOOR TO SIDEWALL SUPPORT L/H BS 500A+10' LBL21 WL156. DSDR SWAA2021071287062Support · corrodedCORROSION SUPPORT ZEE LOCATED BS727 TO BS767 AND STR25R AFT CARGO COMPARTMENT ; 2021-282482 / [01] TOOL USED CALIPER P/;: 700-113-10 S/N:0033158 DUE DATE:14-JUL-21; [02] TOOL USED CALIPER P/;: 700-113-10 S/N:0033158 DUE DATE:14-JUL-21; [03] FABRICATED SUPPORT SDR SWAA2021071287063Web · crackedCRACK WEB - INTERCOSTAL LOCATED BETWEEN BS927 TO BS947.5 AND STR25R AFT CARGO COMPARTMENT ; 2021-282484 / [01] REPLACED WEB INTERCOSTAL LOCATED BETWEEN BS927 TO BS947.5 AND STR25R AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02; B737-700 SRM 51-10-02 ITEM 9 ANSDR IPXA2021070971481Stiffener · crackedINSPECTION TYPE:2CAFT CARGO COMPARTMENT STEP UP BULKHEAD STIFFENER CRACK AT STA.1841 STRINGER 46R.REMOVED,FABRICATED AND REPLACED CRACKED STIFFENER IAW SRM 51-33-01 AND 51-31-01 (MINOR).SDR ASAA2021062235294Transition Panel · corrodedAFT CARGO COMPARTMENT R/H FLOOR TRANSITION PANEL IS PUNCTURED AND GOUGED BETWEEN STA 727J AND 727KDOT:S245. GROUNDED - YES. EVALUATED AFT PIT RH TRANSITION PANEL BETWEEN STA 727J & 727K : ORIGINAL MAT .040" MATERIAL LOSS .040", NO MATERIAL REMAINING . OUT OF LSDR ASAA2021062235289Transition Panel · corrodedFORWARD CARGO PIT TRANSITION PLN R/H STATION 500H TO 500I HAS SEVERAL AREAS OF MINOR CORROSION DOT:A262. GROUNDED - YES. EVALUATED FWD CARGO R/H TRANSITION PNL @ STA 500H TO 500I ORIGINAL MAT'L THK'S .040 REMOVED .012 MATERIAL, :028 REMAINING FOUND TO BE OUT OSDR ASAA2021062235268Angle · corrodedFORWARD CARGO PIT AFT BULKHEAD STATION 500L FROM TRANSITION PLN LEFT TO RIGHT AND ON UP RITE STRUCTURE HAS EXFOLIATED CORROSION. GROUNDED - YES. FOUND R/H AND BOTTOM BULKHEAD ANGLES AT STATION 500L TO BE OUT OF LIMITS DO TO NO LIMITS GIVEN. REMOVED AND REPLACESDR ASAA2021062235265Transition Panel · corrodedAFT CARGO COMPARTMENT R/H FLOOR TRANSITION PANEL HAS MULTIPLE SPOTS OF LIGHT SURFACE CORROSION ON THE UPPER SURFACE BETWEEN APPROX 13" FWD OF STA 727J AND STA 767 (MARKED)DOT: S244. GROUNDED - YES. EVALUATED RH AFT PIT TRANSITION PANEL 13" FWD OF STA 727J TO SSDR SWAA2021070887144Plate · corrodedCORROSION ON PLATE AFT CARGO BAY BS847 RBL23 WL156 ; / [01] CORROSION ON PLATE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.; [02] RECEIVED NEW PLATE ON BFG P.O #823171 /2. NEW PART WILL BE INSTALLED ON FAULT # TTG8Q004VHYV; [03] VERIFIE
Back to JASC 5320