JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021072283153Support · corrodedCORROSION R/H FLOOR TO SIDEWALL SUPPORT BS 727B+10; RBL 21; WL 154 ; / [01] BLENDED CORROSION DAMAGE ON R/H FLOOR TO SIDEWALL SUPPORT BS 727B+10; RBL 21; WL 154 PER SRM 51-10-02-0G-0. REMOVED .013' MATERIAL IN A .5' X 1.2' AREA. ORIGINAL THICKNESS IN AREA IS .SDR SWAA2021072283161Support · corrodedCORROSION R/H FLOOR TO SIDEWALL SUPPORT BS 727D+18 - 727E+6; RBL 21; WL 154 ; / [01] BLENDED MULTIPLE AREAS OF CORROSION DAMAGE ON R/H FLOOR TO SIDEWALL SUPPORT BS 727D+18 - 727E +6 ; RBL 21; WL 154 PER SRM 51-10-02-0G-0. REMOVED .012' MATERIAL IN THE DEEPEST SDR SWAA2021072283165Support · corrodedCORROSION L/H FLOOR TO SIDEWALL SUPPORT BS 797; LBL 21; WL 154 ; / [01] REMOVED CORROSION; FLOOR TO SIDEWALL SUPPORT AT BS 797; RBL21; WL 154 PER SRM51-10-02-0G-0 MEASURE L=1.5'X W=0.75'X D=0.010' MAX. MAT LOSS IS 0.010'; REMAINING THICKNESS IS 0.010'; ORIGINASDR SWAA2021072283170Shield · corrodedCORROSION AFT CARGO BAY FWD SHIELD BS 785; RBL 21; WL 154 ; / [01] VERIFIED APPLICABILITY IAW SRM 53-60-15-0L-1 NOT ALLOWABLE DAMAGE PARTS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-20-02 STEP 9C; [02] VERIFIED APPLICABILITY IAW SSDR SWAA2021072283174Shield · corrodedCORROSION AFT CARGO BAY AFT SHIELD BS 857; RBL 21; WL 154 ; / [01] VERIFIED APPLICABILITY IAW SRM 53-60-15-0L-1 NOT ALLOWABLE DAMAGE PARTS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-20-02 STEP 9C; [02] VERIFIED; [03] REMOVED ACB SSDR SWAA2021072283166Threshold · corrodedCORROSION AFT CARGO BAY SUBTHRESHOLD BS 809; RBL 30; WL 154 ; / [01] REMOVED CORROSION ON AFT CARGO BAY SUBTHRESHOLD B.S 809 RBL 30 WL154 MAX. MATERIAL LOSS L=44';W=2';D=0.007' FOUND OUT OF LIMITS IAW SRM 53-60-15-1A-1 STEP 4G (2)(B) FIG 103 AND DWG 146A8123 TSDR SWAA2021072283163Support · corrodedCORROSION L/H FLOOR TO SIDEWALL SUPPORT BS 767 - 777; LBL 21; WL 154 ; / [01] REMOVED CORROSION; FLOOR TO SIDEWALL SUPPORT AT BS 767-777; RBL21; WL 154 PER SRM51-10-02-0G-0 MEASURE L=3'X W=2'X D=0.015' MAX. MAT LOSS IS 0.015'; REMAINING THICKNESS IS 0.015'; ORSDR SWAA2021071683225Seat Track · corrodedCORROSION ON CABIN SEAT TRACK; ON CROWN AND IN WELL; BS 445-460; RBL 25; WL 208 ; / [01] REMOVED CORROSION ON CABIN SEAT TRACK ON CROWN AND IN WELL; STA 445-460; RBL 25; WL 208. MAX MATERIAL REMOVED WAS .026' .5' BY 1' ON TOP; .008' 1' BY 1'IN WELL. OUT OF LIMSDR AALA202107134001Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO RIGHT TRANSITION PANEL HAS CORROSION LOCATED AT 500F+6, STR L24 R. REPLACED CORRODED TRANSITION PANEL PER SRM 53-30-53-2R.SDR AALA202107136107Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON TRANSITION PANEL LOCATED FROM 500C TO 500H, WATERLINE 360, BUTT LINE 540. INSTALLED ZEE ANGLE CHANNEL ASSEMBLY PER SRM 51-40-02.SDR AALA202107137655Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON TRANSITION PANEL LOCATED AT 727G-767, BUTT LINE 44. REPLACED TRANSITION PANEL PER SRM 51-40-02.SDR AALA202107134717Transition Panel · corrodedAIRCRAFT WAS IN BASE MAINTENANCE: CORROSION FOUND ON TRANSITION PANEL LOCATED AT STA 727H, LEFT BUTT LINE 44. REPLACED TRANSITION PANEL PER SRM 51-40-02.SDR SWAA2021071283256Scuff Plate · crackedCRACK ON SCUFF PLATE FWD POSITION AFT CARGO COMPARTMENT ; 2021-282336 / [01] REPAIRED SCUFF PLATE FWD POSITION AFT CARGO COMPARTMENT IAW BOEING 737-700 SRM 53-60-15-2R-1 REPAIR 1 PARAGRAPH 4.B AND BAC 5975.; [02] REPAIRED SCUFF PLATE FWD POSITION AFT CARGO COMSDR SWAA2021070683093Scuff Plate · crackedFWD CARGO FWD CORNER SCUFF PLATE CRACKED AT PREVIOUSLY WELDED AREA ; / [01] RECIEVED WELD REPAIRED FWD CARGO; FWD CORNER SCUFF PLATE FROM BACKSHOP ON AAR WORK ORDER # 42401-8100-0001 IAW SRM 53-30-15-2R-1.; [02] VERIFIED STEP 1.<BR>AUDIT C/WSDR HNAA2021070100309Floor Support · corrodedL/H FLOOR SILL #3 IS CORRODED AT A PREVIOUS BLEND BETWEEN FRAMES 29-30. REMOVED AND INSTALLED SERVICEABLE LH #3 FLOOR SILL IAW EMB145 SRM 51-40-02.SDR SWAA2021063083177Support · corrodedCORRODED R/H FLOOR TO SIDEWALL SUPPORT BS 880, RBL 22; WL 160. REMOVED CORROSION IAW SRM 51-10-02-0G-0. REMOVED .011' MATERIAL IN A .5' X 1.0' AREA. ORIGINAL THICKNESS IS .040'. OUT OF LIMITS IAW SRM 53-00-53-1A-2 STEPS 4. A. (2)(A) FIGURE 103 DETAIL D. REMSDR AALA202106306387Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO RIGHT TRANSITION PANEL AT STA 500F AND 24R IS CORRODED. REPLACED TRANSITION PANEL REF SRM 53-30-53-2R.SDR SWIA202159190Splice · corrodedCORROSION AS MARKED ON RH FLOOR BEAM SPLICE FR 91. (C-CHECK RO 6/28/2021) BLENDED AND EVALUATED RH FLOOR BEAM SPLICE FR91. MEASUREMENTS .6"L X .35"W X .008"H. NOMINAL THICKNESS .04", REMAINING THICKNESS .032". ITEMS IS OUT OF LIMITS PER REF SRM 51-75-16SDR SWIA202159189Splice · corrodedCORROSION AS MARKED ON RH FLOOR BEAM SPLICE FR 89 (C-CHECK RO 6/28/2021) REMOVED CORROSION FROM RH FLOOR BEAM SPLICE AT FR 89. 100% MATERIAL LOSS. FOUND OUT OF LIMITS REF EMB SRM 51-10-03. REMOVED AND REPLACED RH FLOOR BEAM SPLICE AT FR 89 REF SRM 51-40SDR SWIA202159188Floor Support · corrodedCORROSION AS MARKED ON RH FLOOR BEAM INTERCOSTAL FR 90-91. (C-CHECK RO 6/28/2021) BLENDED AND EVALUATED RH FLOOR BEAM INTERCOSTAL FR 90-91. MEASUREMENTS .8"L X .55"W X .012"H. NOMINAL THICKNESS .04", REMAINING THICKNESS .028". ITEM IS OUT OF LIMITS PERSDR SWIA202159187Doubler · corrodedCORROSION FOUND ON LEFT FLOOR DOUBLER 170-12118-001 AT FRAME 16 AFT RIGHT CORNER (C-CHECK RO 6/28/2021) REMOVED AND REPLACED NEW DOUBLER ON L/H FR 16 , REF. SRM: 51-40-08SDR SWIA202159184Support · corrodedRH SILL HAS CORROSION RIGHT SIDE BETWEEN FRAME 18/19 (C-CHECK RO 6/28/2021) REMOVED AND REPLACED RH SILL BETWEEN FRAME 18-19 PER SRM 51-40-08 APLLIED TOP COAT PER SRM 51-23-06SDR SWIA2021062959183Floor Support · corrodedCORROSION AS MARKED ON RH FLOOR BEAM UPPER AND LOWER SURFACES FR 86-87. (C-CHECK RO 6/28/2021) REMOVED AND REPLACED RH BEAM FR84-90 REF EMB SRM 51-40-08SDR REXA2021061400472Floorbeam · corrodedJ-ANGLE @ FS 280.00 BETWEEN LBL 9 AND RBL 9 IS CORRODED. REMOVED & REPLACED FS 280 J ANGLE IAW SRM 51-42-06-001-001-A01,51-25-16-001-001-A01.SDR REXA2021062900467Angle · corrodedANGLE @ FS 349.00 STGR 20R HAS CORROSION. R & R UNSERVICEABLE ANGLE @ FS 349 STGR 20R WITH A SERVICEABLE ANGLE IAW CRJ 900 SRM 51-42-06-001-001(A01) AND REMOVED CORROSION ON STGR
20R IAW ENDEAVOR AIR EA #CRJ953-11647 DATED 6/9/21 REV IR.SDR REXA2021062900429Floor Support · corrodedFLOORBEAM AT LBL27 CORRODED IN MULTIPLE SPOTS FROM FS 977.00 TO FS 1098.00. COMPLIED WITH CRJ 900 SRM 53-00-44-201-001-A03 FOR REPLACEMENT OF LBL27 FLOORBEAM.SDR REXA2021062900437Floor Support · corrodedR/H FLOOR SILL AT RBL36 HAS 3 AREAS OF CORROSION BETWEEN FS 280.00 AND FS 319.70. REMOVED AND REPLACED R/H FLOOR SILL AND FLOOR SILL DOUBLER BETWEEN FS 280 TO FS 319.70 IAW CRJ900 SRM 51-42-06-001-001-A01 AND 51-42-13-001-001-A01. REMOVED AND REPLACED R/H SDR REXA2021062900438Floor Support · corrodedR/H FLOOR SILL AT RBL36 HAS 3 AREAS OF CORROSION BETWEEN FS 280.00 AND FS 319.70. REMOVED AND REPLACED R/H FLOOR SILL AND FLOOR SILL DOUBLER BETWEEN FS 280 TO FS 319.70 IAW CRJ900 SRM 51-42-06-001-001-A01 AND 51-42-13-001-001-A01. REMOVED AND REPLACED R/H FLOSDR REXA2021062900447Longeron · corrodedCORROSION FOUND ON RH LONGERON, AFT OF STRG 25R, BTW FS 333-349. REPAIRED CORROSION ON STR R25 BETWEEN FS 333 TO FS 349 IAW APPROVED REO 690-53-21-1380, REV.(P1).SDR AALA202106290485Stiffener · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED STIFFENER LOCATED FROM FR11 TO FR12 AND Y765 IN COCKPIT AREA. REPLACED STIFFENER PER SRM 51-42-11-801, SRM 51-72-11-911-001 AND DWG D53113448.SDR AALA202106295111Stiffener · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED STIFFENER LOCATED FROM FR11 TO FR12 AND Y1292 IN COCKPIT AREA. REPLACED STIFFENER PER SRM 51-42-11-801, SRM 51-72-11-911-001 AND DWG D53113448.SDR MASA20210628247Intercostal · corrodedCORROSION ON INTERCOSTAL 20R BTW FS319-349 AND CLEATS AT E/E COMPARTMENT. (FUS).|DAMAGED INTERCOSTAL 20R BTW FS319-349 AT E/E COMPARTMENT. (FUS) WAS REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01 PAR.6.C AND SRM 51-42-21-001-001-A01 PAR.6.C.SDR MASA20210628246Intercostal · corrodedCORROSION ON INTERCOSTAL 20R BTW FS310-319 AND CLE ATS AT E/E COMPARTMENT. (FUS)|DAMAGED INTERCOSTAL 20R BTW FS310-319 AT E/E COMPARTMENT. (FUS) WAS REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01 PAR.6.C AND SRM 51-42-21-001-001- A01 PAR.6.C.SDR MXIA2021062210001Sidewall Panel · detachedTHERE WAS A MOMENTARY BAGGAGE COMPARTMENT FIRE WARNING CAS MESSAGE ON CLIMB OUT FROM KFHB. BEFORE THE FLIGHT CREW COULD TAKE ANY ACTION THE WARNING EXTINGUISHED. THE MESSAGE DURATION WAS APPROXIMATELY 2 SECONDS. NO CORRECTIVE ACTION WAS TAKEN BY THE FLIGHT CRESDR MASA20210614234Intercostal · corrodedFWD E&E BAY INTERCOSTAL CORRODED RH SIDE FS319-FS333 STGR 20R|R&R INTERCOSTAL IAW SRM 51-42-06SDR CALA2021061400874Fastener · missingPDA 3 PER PDA INSPECTION, FOUND ONE FASTENER MISSING ON PANEL #196AR FWD ROW 2ND FROM INBD. REF IPD 53-36-01-07A ITM#10. NEW FASTENER INSTALLED. NO OTHER DAMAGE NOTED. OK FOR SVC. ADD EMP:U114956SDR CALA2021061400866Floor Support · corrodedA3NB-53-3-6222 MAIN CABIN FLOOR RH SHEAR PLATE AT FRFR69-70 CORR ODED. (DOT 38-43)SDR MK1Y20210614005Web · puncturedLOWER WEB, FLOOR BEAM, STA246, RBL 50-80. MAINTENANCE FOUND A PUNCTURE IN LOWER WEB OF STA 246 FLOOR BEAM AT APPROXIMATELY RBL 75.0 THIS DAMAGE WAS FOUND TO BE OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 LIMITS.SDR SWIA2021082060516Floor Support · corroded*AREAS OF CORROSION ON LH PRESSURE FLOOR SILL WATER RAIL CHANNEL BETWEEN FS 720.00 €“ 830.00. AREAS MARKED. REPAIRED CORROSION DAMAGE TO WATER DRAIN CHANNEL IAW REO 690-53-41-274 REV-- DATED 2021-07-07, C/W TASKCARD 51-900-1002-SKY, SEE CONTINUATION FOR WSDR SWIA2021082060515Floor Support · corroded*MULTIPLE AREAS OF CORROSION ON RH PRESSURE FLOOR SILL ANGLE BETWEEN FS 720.00 €“ 847.00. AREAS MARKED. (C-CHECK RO 8/18/2021) REMOVED CORROSION FROM RH PRESSURE FLOOR SILL ANGLE BETWEEN FS720 - FS847 AND FOUND REWORKED AREA TO BE ACCEPTABLE AS IS REF SDR SWIA2021081860330Door Sill · corroded* PAX DOOR SILL UPPER ANGLE IS CORRODED AROUND MULTIPLE NUTPLATE HOLES. (C-CHECK RO 8/16/2021) REMOVED AND REPLACED PAX DOOR SILL UPPER ANGLE CRJ700 SRM 51-42-06-001-A01, SRM 51-42-21-001-A01 AND DRAWING # SH670-31810 REV. Y. PRESSURIZATION LEAK CHECK GSDR SWIA2021081860327Intercostal · corroded* INTERCOSTAL 21L AT APPROX. FS 333.00 IS CORRODED. (C-CHECK RO 8/16/2021) REMOVED AND REPLACED INTERCOSTAL IN FWD CABIN BETWEEN FS333.00 TO FS347.00 STRINGER21L IAW CRJ 700 SRM 51-42-06-001-001-A01 / 51-42-21-001-001-A01 AND DRAWING #SH670-31810 REV AESDR SWAA2021071282923Baffle · crackedBAFFLE CLIP IS CRACKED ON FWD SIDE OF BS 500B LBL25 WL 155 ; / [01] REMOVED BAFFLE CLIP BS 500B LBL 25 WL 155 PER SRM 51-40-02-0G-0; [02] UPDATED MEASUREMENT TABLE; [03] LOCATED AND DRILLED NEW CLIP AT BS 500B LBL 25 WL 155 PO# 827746/1 PER SRM 51-40-05-0G-0 ASDR MASA20210706261Web · crackedCRACK AT UPPER WEB OF ADG COMPARTMENT, BELOW OF SETTLEMENT AREA OF ADG PUMB. UPPER WEB OF ADG COMPARTMENT, BELOW OF SETTLEMENT AREA OF ADG PUMB WAS REPAIRED PER CRJ 900 SRM 53-11-43-201-001-A01.SDR MASA20210706260Intercostal · corrodedCORROSION ON INTERCOSTALS (3EAS) BTW FS 349-364, STGR 26R-26L. CORROSION IN INTERCOSTAL BTW FS 349-364, STGR 26LH WAS REMOVED PER CRJ 900 SRM 51-21-06-001-001-A01AND WAS FOUND WITHIN LIMITS PER CRJ 900 SRM 53-21-23-101-003-A02. INTERCOSTALS BTW STGR 27-26LH ANSDR HNAA2021070100308Gusset · corrodedRH OMEGA BEAM GUSSET #3 CORRODED. REMOVED AND REPLACED RH OMEGA BEAM GUSSET #3 IAW EMB145 SRM 51-40-02.SDR HNAA2021070100302Floor Support · corrodedCARGO DOOR CUTOUT LOWER FLOOR SILL CORRODED. REMOVED AND PERFORMED INSTALLATION OF SERVICEABLE CARGO DOOR CUTOUT LOWER SILL IAW EMB 145 SRM 51-40-02.SDR AALA202107013244Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND CORROSION ON FUEL 540NB PANEL AT RIBS 18-19 AND STR 8-11. REPLACED FUEL PANEL REF SRM 57-27-11.SDR REXA2021062900466Intercostal · corrodedAVIONICS BAY AT FS 364.00 INTERCOSTALS AT STRINGER 27 LEFT AND RIGHT CORRODED. REMOVED & REPLACED INTERCOSTALS AT 27L & 27R IAW SRM 51-42-21-001-001-A01 REMOVED AND REINSTALLED AVI DOOR PROX SWITCH OP CKS GOOD IAW AMM 52-70-08-000/400-801-A01 & AMM 57-42-00-SDR SWAA2021062882868Strap · corrodedAFT CARGO COMP. FLOOR STRAP ON ST 772.5 AND RBL 21.00 IS CORRODED AROUND NUTPLATE HOLE ; / [01] FLOOR STRAP OUT OF LIMITS CORROSION FOLIATED REF B737-700 SRM-53-00-53-1A-2; [02] VERIFIED STEP 1; [03] RECEIVED NEW FLOOR STRAP PN 146A9401-4 AAR TAG A56662; FLOOR