JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021071285013Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT AFT CARGO BAY BS794 - 847 RBL26 WL157. ; / [01] REMOVED SUB THRESHOLD WEB. IAW SRM 51-40-02; [02] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS IAW SRM 53- 60- 15 -1A -1 ; REMOVED CORROSION ON SUBTHESHOLD WEB AT AFT CARGO SDR SWAA2021071285007Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727B - BS767 RBL20 WL156. ; / [01] REMOVED ACB FLOOR TO SIDEWALL SUPPORT R/H BS 727-767 RBL 20 IAW SRM 51-40-02; [02] VERIFIED REMOVED; [03] RECEIVED NEW ZEE ASSEMBLE LOT #1460159; [04] LOCATED AND DRILSDR SWAA2021071285001Support · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS767- BS787 RBL21 WL157. ; / [01] REMOVED ACB FWD SHIELD IAW SRM 51-40-02.; [02] VERIFIED REMOVAL; [03] UPDATED MEASURMENTS; [04] LOCATED; DRILLED; AND COUNTERSANK AFT CARGO BAY FWD SHIELD BS 767-BS787 RBL21 WL157 IAW SDR SWAA2021071285029Shield · corrodedCORROSION ON AFT SHIELD AT FWD CARGO BAY BS500 - BS500A RBL23 WL156. ; / [01] REMOVED FWD CARGO BAY SHIELD BS 492 - BS 500A RBL23 WL156 IAW SRM 51-40-02-0G-0; [02] THERE IS NO SRM ALLOWABLE DAMAGE FOR FWD CARGO BAY SHIELD. PART TO BE REPAIR BY REPLACEMENT IAW SDR SWAA2021071285022Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT FWD CARGO BAY BS442 RBL25 WL156. ; / [01] REMOVED SUB THRESHOLD WEB IAW 51-40-02; [02] REMOVED DAMAGE FROM SUB THRESHOLD IN A 1.2LX.9W AREA. ORIGINAL THICKNESS IS .045 IAW SRM 53-30-15-01-1 FIG 5 ITEM 3. SRM 51-10-02; SRM 53-30SDR FDEA202106161551Longeron · corrodedAFT CARGO - STATION 1897 LONGERON 44 RIGHT FOUND WITH SURFACE CORROSION. AFT CARGO - STATION 1897 LONGERON 44 RIGHT SURFACE CORROSION REMOVED AS PER SRM 51-21-01-OG AND FOUND CRACKED. CRACKED LONGERON 44 RIGHT AT STATION 1897 CARRIED OUT REPAIR AS PER SRM SDR SWAA2021070785236Support Bracket · corrodedCORROSION SUPPORT BRACKET (STIFFERNER) LOCATED BS1088 BETWEEN RBL11 TO LBL11 AND WL217 APPROX ON APU COMPARTMENT ; 2021-282400 / [01] TOOL USED: PRECISION RADIUS GAUGE PN:S167C SN:AE-27309 DUE DATE:05-AUG-21.; [02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015SDR SWAA2021070684620Shield · corrodedFWD CARGO COMPT. STA 492+4'; RBL25; WL156 SHIELD HAS CORROSION UPPER SURFACE DOT A-21-31 ; / [01] BLENDED AND REMOVED CORROSION ON FWD CARGO R/H SHIELD STA 492+4 IAW SRM 53-30-15-1A-1 STEP 2A[1]; [02] MATERIAL THICKNESS IS .032 MATERIAL LOSS IS .006 MAT REMAINSDR SWAA2021070684673Transition Panel · corrodedDOT 68-034 AFT PIT STA 767+3 RBL22 TRANSITION PANEL UPPER AND LOWER SURFACES HAVE CORROSION ; / [01] REMOVED CORROSION; INSPECTED WITH 10X MAG GLASS; NO DEFECTS IAW SRM 53-60-15-1A-1; [02] ORIGINAL T= .050' LOSS OF .007' REMAINING T= .043' FOUND TO BE OUT OF LSDR SWAA2021070684657Transition Panel · corrodedDOT 61-034 AFT PIT STA 747+2 LBL22 TRANSITION PANEL UPPER SURFACE HAS CORROSION ; / [01] REMOVED CORROSION FROM BS 747+2 LBL 22; ORIGINAL T= .040'; LOSS OF .015' REMAINING .025' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL A-A TOOLING # 21461SDR SWAA2021070684630Transition Panel · corrodedDOT 35-034 AFT PIT STA 727E+18' RBL 22 TRANSITION PANEL UPPER SURFACE HAS CORROSION ; / [01] REMOVED CORROSION FROM BS 727E+18 RBL 22; ORIGINAL T= .040'; LOSS OF .020' REMAINING .020' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL A-A TOOLING #SDR SWAA2021063084703Baffle · crackedFWD CARGO COMP. BAFFLE BETWEEN STA 500A TRHU 500B STR.25L IS CRACKED ; / [01] REMOVED BAFFLE AS REF. B737-700 SRM 51-40-02-0G-0; [02] CUTED BAFFLE THROUGH ITS WEB FROM THE TOP FLANGE TO THE LIGHTING HOLE TO FACILITATE WIRE BUNDLE INSTALATION AS REF. B737-700 SSDR JJBA20210616036Floor Support · corrodedCF3, LH OMEGA BEAM LOWER FLANGE CORRODED FROM FR 45-46 TO 52-53. LH OMEGA BEAM LOWER FLANGE FROM FR 45-46 TO 52-53 IS OUT OF LIMIT. LH OMEGA BEAM FR 45-46 TO 52-53 REMOVED FOR REPLACEMENT. LH OMEGA BEAM CROSS BEAM O/B FR49 AND CROSS BEAM MIDDLE FR49-50 REMOVEDSDR JJBA20210616030Floor Support · corrodedCF1 BTW FR 21-23, LH BEAM FLOOR SUPPORT LIP CORRODED. CF1 BTW FR 21-23, LH BEAM FOUND CRACKED AFTER INVESTIGATION. CF1 BTW FR 21-23, LH BEAM REPLACED.SDR JJBA20210616028Support · corrodedCF2 RH SILL #1 CORRODED. CF2 RH SIDE FRAME 25 UNDER SILL NO 1 CUT FOR REPAIR. CF2 RH SIDE FRAME 25, BTW STR 15R-16R T BAR REMOVED FOR ACCESS. CF2 RH SIDE FRAME 25 UNDER SILL NO 1 REPAIRED. CF2 RH SIDE FRAME 25, BTW STR 15R-16R T BAR REINSTALLEDD.SDR SCNA20210618068Support · crackedA CRACK APPROXIMATELY 3/4 INCHES UNDERNEATH A WEATHER RADAR SUPPORT FLATFORM AT RIGHT SIDE IN EE BAY JUST FWD OF EE BAY DOOR. REPAIRED WEATHER REDAR SUPPORT PLATFORM IN EE BAY IAW B737-800 SRM 51-20-13-2R REP. 1.SDR CALA2021061800886Shear Panel · corrodedA3NB-53-3-6222 MAIN CABIN FLOOR LH SHEAR PLATE AT FR69-70 CORROD ED.(DOT 38-44)() REMOVED AND REPLACED SHEAR PLATGE P/N #D5347112420000 BATCH#0003 640061 MAIN CABIN FR.69 TO FR70 L/H IAW SRM 51-42-11. SFR 102568 4 .SDR DALA2021061703299Floor Support · corrodedSHIP 3238 CORROSION FLOOR BEAM +Y1162.5 LOCATED FR 68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1842633)SDR DALA2021061703298Floor Support · corrodedSHIP 3238 CORROSION FLOOR BEAM -Y765 LOCATED BTW FR 67 TO FR 68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1842629)SDR DALA2021061703295Intercostal · corrodedAFT CARGO INTERCOSTAL ABOVE STR 30 IS CORRODED AT FRAME 1028, AFT SIDE. NRC 247: SUMMERY - REPLACED INTERCOSTAL ABOVE STR 30 AT FRAME 1028 PER B717 SRM 53-20-04 PROCEDURE 3. (LP #1842038)SDR SWIA2021082060529Striker · corrodedSERVICE DOOR LOWER SILL SEAL STRIKER FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL SEAL STRIKER REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01, 51-21-16-001-001-A01 TEMP REV-51-0068 AND DWG SH670-31950 REV -Y, SEE CONTINUE CARD FOR PERTINSDR SWIA202160527Fitting · corrodedSERVICE DOOR SURROUND STRUCTURE LOWER SILL WEB FLOOR PROTECTOR FITTING AT F/S 322 CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL THRESHOLD ATTACH FITTING AT F/S 322.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG SH670-31950 REV Y, SEESDR SWIA2021082060526Web · corrodedSERVICE DOOR LOWER SILL FLOOR WEB PROTECTOR CORRODED AT F/S330.00 (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL THRESHOLD ATTATCH FITTING AT F/S 333.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV-Y. COMPLIED WITH 51-900-1002SDR AALA202107262429Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT GALLEY AREA SHEAR PLATE LOCATED BETWEEN FR69 TO FR70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11-801 AND DWG D53474180.SDR SWAA2021072284714Intercostal · crackedCRACKED INTERCOSTAL AT B.S. 312-328; R.B.L. 33; W.L. 208.1. ; / [01] REMOVED INTERCOSTAL FROM BS 312-BS 328 RBL 33 WL208.1IAW SRM 51-40-02-0G-0; [02] CORRECTED MEASUREMENTS; [03] REMOVED INTERCOSTAL FROM BS 312-BS 328 RBL 33 WL208.1IAW SRM 51-40-02-0G-0; [04] SDR SWAA2021072284719Intercostal · crackedCRACKED INTERCOSTAL AT B.S. 312-328; L.B.L. 47; W.L. 208.1. ; / [01] REMOVED INTERCOSTAL FROM BS 312-328 LBL47 WL 208.1 IAW SRM 51-40-02-0G-0; [02] LOCATED AND DRILLED NEW INTERCOSTAL P/N 141A5410-12 AT BS 312-328 LBL47 WL 208.1 IAW SRM 51-40-05-0G-0 AND DWG #SDR SWAA2021072284720Fitting · corrodedCORROSION ON FORWARD ENTRY DOOR GIRT BAR FORWARD ATTACH POINT FITTING ON THE FLOOR. ; B.S. 312; L.B.L. 60; W.L. 208.1. / [01] CORROSION FOUND ON FWD ENTRY DOOR GIRT BAR FWD ATTACH POINT FITTING BS 312 LBL 56 WL 208.1 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ONSDR SWAA2021072284723Channel · corrodedCORROSION ON FORWARD SERVICE DOOR MOP SILL AT B.S. 312-344; R.B.L. 56; W.L. 208.1. ; / [01] VERIFIED APPLICABILITY OF SRM 53-10-15-01-2 IDENTIFICATION -2 FOR IDENTIFICATION AND SRM 53-10-15-1A-2 DAMAGE-2 FOR ALLOWABLE LIMIT; [02] REMOVED CORROSION FROM FORWARDSDR SWAA2021072284722Channel · corrodedCORROSION ON FORWARD ENTRY DOOR MOP SILL AT B.S. 312-344; L.B.L. 56; W.L. 208.1. ; / [01] REMOVED CORROSION FROM FORWARD ENTRY DOOR MOP SILL BS 312-BS 344 LBL 56 WL 208.1 IN AREA OF 2'X 1' ORIGINAL MATERIAL THICKNESS 0.090' IAW SRM 51-10-02-0G-0; [02] VERIFIEDSDR SWAA2021071684792Seat Track · corrodedCORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN BS 500D+7-520 LBL 25 WL 208. ; / [01] REMOVED CORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN STA 500D+7-520; LBL 25; WL 208. MAX MATERIAL REMOVED WAS .034' .5' BY 1' ON TOP AND .007' 1' BY 1' IN WELL. OUT OF LSDR SWAA2021071684793Seat Track · corrodedCORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN BS 500D+8-520 LBL 45 WL 208. ; / [01] REMOVED CORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN STA 500D+8-520; LBL 45; WL 208. MAX MATERIAL REMOVED WAS .033' .5' BY 1' ON TOP AND .005' 1' BY 1' IN WELL. OUT OF LSDR SWAA2021071684807Seat Track · corrodedCORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN BS 540-620 LBL 25 WL 208. ; / [01] REMOVED CORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN STA 540-620; LBL 25; WL 208. MAX MATERIAL REMOVED ON TOP WAS .025' .5 BY 1'; .018' 1' BY 1' IN WELL. OUT OF LIMITS PER SDR AALA202107131940Stiffener · damagedAIRCRAFT IN BASE MAINTENANCE: ON STIFFENER AT STA927 RBL 24.75 FOUND DAMAGE ON INCOMING VISUAL INSPECTION. REPLACED STIFFENER IAW B737-NG SRM 51-40-02.SDR AALA202107139710Stiffener · damagedAIRCRAFT IN BASE MAINTENANCE: STIFFENER AT STA LBL 24.75 FOUND DAMAGED ON INCOMING VISUAL INSPECTION. REPLACED STIFFENER IAW BAC DWG 147A5350 & B737-NG SRM 51-40-02.SDR AALA202107125573Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED AREA ON LOWER SILL LOCATED FROM FR 66 TO FR 68 AND STRG 23R AT AFT GALLEY AREA. REPLACED LOWER SILL IAW A319 SRM 51-72-11-911-001, SRM 51-42-11-801 AND DWG D53480505.SDR AALA202107086870Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED AREA ON LOWER SILL AT FR68 AND STR 23L. PERFORMED PERMANENT REPAIR ON LOWER SILL FR68 AT LEVEL STR23L AT AFT GALLEY AREA, IAW A319 SRM 53-41-14-300-001.SDR SWAA2021070283277Scuff Plate · crackedAFT CARGO DOOR FORWARD CORNER SCUF PLATE IS CRACKED ; / [01] UPDATED MEASUREMENTS; [02] RECIEVED REPAIRED AFT CARGO; FWD CORNER SCUFF PLATE FROM BACKSHOP. ALL WORK ACCOMPLISHED ON AAR WORK ORDER# 42268-1600-0035 IAW SRM 53-30-15-2R-1.; [03] ITEM 2 CORRECTING ASDR A6WA202106307806Channel · dentedAFT EQUIPMENT COMPARTMENT FUSELAGE FRAME CHANNEL FROM FS 689.5 TO FS 694.00 STR 24 LH HAS MULTIPLE DENTS. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED DAMAGED FRAME CHANNEL AND REPLACED WITH FABRICATED FRAME CHANNEL AT FS 689.5 TO FS 694.00 STR 24 LH. NEW CHASDR AALA202106288071Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED AREA ON FLOOR BEAM Y1292 FROM FR64 TO FR66. REPLACED FLOOR BEAM Y1292 IAW A319 SRM 51-42-11-801, SRM 51-72-11-911-001 AND DWG D53472000.SDR AALA202106226598Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM Y765 FR66 AT AFT GALLEY AREA, MEASURING L=0.645 INCHES W= 0.330 INCHES D= 0.035 INCHES. REPLACED FLOOR BEAM Y765 FR64 TO FR66 AT AFT GALLEY AREA.SDR DALA2021061703294Floor Support · corrodedFLOOR SUPPORT CORRODED AT L-1 DOORWAY APPROX. 11 IN INBD OF FLOOR PAN, FROM STA 160 TO STA 200. SUMMARY - NRC 001-0024:2040-0024/001 00358: REPLACED FLOOR SUPPORT PER BAC DWG 9936534. (LP #1841878)SDR DALA2021061503235Strap · wornSHIP 651 WEAR ON STRAP STA 1667 LBL 0 Z -8 AT PAX CABIN. CORRECTIVE ACTION: SUMMARY OF NRC 00439. STRAP STA 1667 LBL 0 Z -8 AT PAX CABIN WAS REPAIRED. PER B757-200 SRM. (1840930)SDR DALA2021061503234Floor Support · corrodedSHIP 651 CORROSION ON FLOOR SUPPORT BTW STA 710 AND STA 720 AND LBL 62 (W2 AREA) (L2 ENTRY AREA) PASSENGER CABIN. CORRECTIVE ACTION: SUMMARY OF NRC 00650: CORROSION LEVEL 2. FLOOR SUPPORT WAS REPLACED PER B757-200 S.R.M.SDR SWIA2021082060525Angle · corrodedSERVICE DOOR LOWER SILL ANGLE BETWEEN F/S319.00 AND 349.00 FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL ANGLE BETWEEN F/S 319 AND F/S 349 REPLACED IAW CRJ 900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV-Y. COMPLIED WITH 51-900-10SDR SWIA2021082060524Angle · corrodedSERVICE DOOR LOWER SILL ANGLE AT F/S 346.00 FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL ANGLE AT F/S 346.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV-Y. COMPLIED WITH 51-900-1002-SKY. SEE CONTINUE CARD FOR SDR SWIA2021082060523Angle · corrodedSERVICE DOOR LOWER SILL ANGLE AT F/S 339.00 FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL ANGLE AT F/S 339.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV-Y. COMPLIED WITH 51-900-1002-SKY. SEE CONTINUE CARD FOR PSDR SWIA2021082060521Angle · corrodedSERVICE DOOR LOWER SILL ANGLE AT F/S 330.00 FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL ANGLE AT F/S 330.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH67O-31950 REV-Y. COMPLIED WITH 51-900-1002-SKY. SEE CONTINUE CARD FORSDR SWIA2021082060520Angle · corrodedSERVICE DOOR ANGLE ON LOWER SILL AT F/S321.00 FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL ANGLE AT F/S 321.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV-Y. COMPLIED WITH 51-900-1002-SKY. SEE CONTINUE CARD FOSDR SWIA2021082060519Angle · corrodedSERVICE DOOR LOWER SILL MOUNTING ANGLE FOUND CORRODED (C-CHECK RO 8/18/2021) SERVICE DOOR LOWER SILL FLOOR PANEL MOUNTING ANGLE REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV-Y. COMPLIED WITH 51-900-1002-SKY. SEE CONTINUNE CARD FSDR SWIA2021081860336Floor Support · corroded* RH FLOOR SILL HAS CORROSION FROM FS 280 TO FS 319 MARKED (C-CHECK RO 8/16/2021) REMOVED AND REPLACED NEW RIGHTHAND CABIN FLOOR SILL BETWEEN FS280.00 TO FS319.00 STRINGER17R IAW CRJ 700 SRM 51-42-06-001-001-A01 / 51-42-21-001-001-A01 / 51-42-13-001-001
Back to JASC 5320