SDR SWAA2021070178429Web · corrodedCORROSION WEB - INTERCOSTAL LOCATED BTW BS 767 TO BS 787; AT LEVEL STR 25R AND RBBL 21 AT AFT CARGO COMPARTMENT ; 2021-255279 / [01] TOOL USED P/N: NORTEC 500D; S/N: 500X1693P030456;CAL DUE DATE: 30-NOV-21; [02] REPLACED WEB-INTERCOSTAL LOCATED BTW BS 767 TO BSDR SWAA2021061478458Gusset · crackedGUSSET CRACKED AT STR19 L/H BS500D WL170 / VERIFIED LOCATING AND DRILLING OF NEW GUSSET IAW SRM 51-40-05; DWG 143A7902. OK TO INSTALL.; INSTALLED GUSSET AT B/S 500D STR 19 L/H LO# 1457203-12 IAW SRM 51-40-02 AND DWG 143A7902 REV:-; VERIFIED INSTALLATINO OF GUSSDR SWAA2021061478457Gusset · crackedGUSSET CRACKED AT STRINGER 19 R/H BS500D 154 ; GUSSET CRACKED AT STRINGER 19 R/H BS500D WL170 / INSTALLED GUSSET AT B/S 500D STR 19 R/H LOT#1453293-4 IAW SRM 51-40-05 AND DWG 143A7902 REV:-; REFERENCE ADDED FOR INSTALLATION PER SRM 51-40-02; VERIFIED INSTALLATSDR AALA202106071096Cover · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON JOINT COVER LOCATED AT LEVEL -Y81 AND FR14. REPLACED JOINT COVER PER SRM 51-72-11-911-001 AND DWG D53112829.SDR V0XD20210606001Angle · corrodedFLOOR 1/4 TURN ON THE FWD SIDE OF THE 280 CROSSBEAM IS CORRODED. CORRECTIVE ACTION: REMOVED AND REPLACED THE 1/4 TURN ANGLE(PN: CC670-34-95-1) ON THE FWD SIDE OF THE 280 CROSSBEAM IAW CRJ 900 SRM 51-42-06SDR CALA2021053100748Shear Web · corrodedAFT CABIN RH SHEAR WEB AT FR 70 LOWER SURFACE HAS CORROSION AND UPPER SURFACE HAS TOOL MARK A3NB-53-3-6222. GENERATED BY N078570 ON NR 9294610/HAECO NR 24610 REMOVED AND REPLACED CORRODED SHEAR WEB AT FR 70-69 LOWER SURFAC E IAW A320 SRM 51-42-11-001 SDR. ACCOSDR FDEA202105281415Floor Support · crackedFOUND BULK CARGO COMPARTMENT STRINGER CRACK AT STA1958.00 LBL8.2 BULK CARGO COMPARTMENT AT STA1958 LBL 8.2 CRACKED STRINGER REPAIRED AS PER B777 SRM 53-70-53-2R REPAIR 2 REV 38. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100SDR SWIA202160695Intercostal · corrodedINTERCOSTAL BETWEEN FS295 AND FS310 STRINGER 20R FOUND CORRODED. SH670-32047-951. (C-CHECK RO 8/31/21) INTERCOSTAL BETWEEN FS295 AND FS310 STRINGER 20R SH670-32047-951 WAS REMOVED AND REPLACED IAW CRJ 700 SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01. FSDR SWAA2021063078297Strap · corrodedCORROSION. ** AFT WET AREA GALLERY FLOOR SUPPORT. WEB STRAP BETWEEN STA 1006 & 1016 LBL 3 ; / [01] REMOVED CORROSION AT AFT WET AREA GALLEY SUPPORT WEB STRAP BETWEEN STA 1006-1016 LBL 3 AS PER B737-700 SRM 51-10-02-0G-0; NO SRM ALLOWABLE DAMAGE EXIST.; [02] VESDR SWAA2021063078296Web · corrodedCORROSION ** AT AFT WET GALLERY SUPPORT FLOOR. WEB FORWARD OF AFT PRESSURE BULKHEAD STA 1016 LBL 4 TO LBL15 ; / [01] REMOVED CORROSION AT WEB STA 1016 AND LBL 4-16 AS PER B737-700 SRM 51-10-02-0G-0; NO SRM ALOWABLE DAMAGE EXIST; [02] REMOVED FASTENER (75%) AS SDR SWAA2021063078290Floor Support · crackedAFT WET AREA FLOOR. SUPPORT INTERCOSTAL APPEAR CRACK AND HAS ELONGATED HOLES BETWEEN STA 927 & 947 BL -0 ; / [01] PERFORMED HFEC INSP ON AFT WET AREA FLOOR SUPPORT INTERCOSTAL B/W STA 927 & 947 BL-0; IAW B737 NDT P6 51-00-00 PROC.23; CRACK CONFIRMED.<BR>TOOL USDR SWIA202158827Floor Panel · corrodedCORROSION- FWD WET AREA, RH SILL PANEL HAS 2EA AREAS OF CORROSION BETWEEN FR 18-19 AS MARKED. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED RH SILL PANEL BETWEEN FR 18-19 AS MARKED. REF EMB SRM 51-40-08 APLLIED SURFCE PROTECTION PER SRM 51-23-06SDR SWIA202158825Support Bracket · brokenAFT WET AREA- 2EA PANEL SUPPORT BRACKETS BROKEN OFF ON FR 86 ON RH & LH SIDE AS MARKED. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED AFT WET AREA- 2EA PANEL SUPPORT BRACKETS ON FR 86 ON RH & LH SIDE AS MARKED.REF: EMB SRM 51-40-08 APPLIED SURFACE PROTECTSDR SWIA202158824Gusset · corrodedCORROSION- AFT WET AREA, RH INBD GUSSET PLATE HAS CORROSION ON FR 89 AS MARKED. (C-CHECK RO 6/18/2021) / REMOAVED AND REPLACED RH INBD GUSSET PLATE FR 89 REF SRM 51-40-08SDR SWIA202158823Gusset · corrodedCORROSION- AFT WET AREA, RH INBD GUSSET PLATE HAS CORROSION ON FR 90 AS MARKED. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED RH INBD GUSSET PLATE FR 90 REF SRM 51-40-08SDR SWIA202158822Gusset · corrodedCORROSION- AFT WET AREA, RH OUTBD GUSSET PLATE HAS CORROSION ON FR 90 AS MARKED. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED RH OUTBD GUSSET PLATE FR 90 REF SRM 51-40-08SDR SWIA202158821Floor Support · corrodedCORROSION- AFT WET AREA, RH OUTBD PANEL SUPPORT(FR88-90) HAS AREAS OF CORROSION AS MARKED. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED RH OUTBD PANEL SUPPORT(FR88-90 REF SRM 51-40-08SDR SWIA202158820Support · corrodedCORROSION- AFT WET AREA, LH OUTBD PANEL SUPPORT(FR88-90) HAS CORROSION ON FWD END AS MARKED. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED LH OUTBD PANEL SUPPORT(FR88-90) REF SRM 51-40-08SDR SWIA202158819Shear Panel · corrodedCORROSION- AFT WET AREA, RH SHEAR PANEL HAS AREAS OF CORROSION AS MARKED. FR-87-88. (C-CHECK RO 6/18/2021) / REMOVED AND REPLACED RH SHEAR PANEL AFT WET AREA FR 87-FR 88 REF SRM 51-40-08SDR SIMA20210527008Floor Support · crackedCARGO DOOR SILL FLOOR SUPPORT ANGLES AT FRAME 66 AND 67 ARE CRACKED. -C/A-RAR CARGO DOOR SILL SUPPORT ANGLES AT FRAME 66 AND 67 IAW SRM 51-40-02.SDR SWAA2021061477943Panel · crackedPANEL 344JB HAS CRACKED FASTENER HOLE. ; / REPLACED PANEL 344JB.; REPLACED PANEL 344JB; PANEL WILL BE INSTALLED ON CUSTOMER CARD NUMBER TTG8Q004T9HE.; VERIFIED REPLACED PANEL 344JB; PANEL WILL BE INSTALLED ON CUSTOMER CARD NUMBER TTG8Q004T9HE.SDR AALA202106119010Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF Z-ANGLE AT STA 990 BETWEEN RBL 34 AND RBL 47, MEASURING L=1.0 IN, W=1.0 IN, D=0.05 IN. REPLACED Z-ANGLE WITH NEW IAW AARD 51-00-05-1.SDR AALA202106119009Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF Z-ANGLE BETWEEN STA 991 AND STA 1014 AT RBL 32, MEASURING L=1.0 IN, W=1.0 IN, D=0.05 IN. REPLACED Z-ANGLE WITH NEW IAW AARD 51-00-05-1 AND DRAWING 147A5700.SDR ASAA2021052735070Strap · corrodedR-1 MOP SILL STRAP STA. 286-307 CORRODED. GROUNDED - YES. REMOVED AND REPLACED STRAP IAW 737-900 SRM 51-40-02-0G-0W-.5" O-.200" R-.0" L-1" D-.200".SDR ASAA2021052735020Floor Support · crackedFLOOR PANEL SUPPORT INTERCOASTAL CRACKED STA. 312-328 RBL 32. GROUNDED - YES. REMOVED AND REPLACED INSTERCOSTAL IAW 737-900 SRM 51-40-02-0G-0.SDR SWAA2021060778298Web · corrodedCORROSION ON AFT WET AREA FLOOR SUPPORT WEB STRAP STA 1016 RBL 20. REMOVED CORROSION. NO LIMITS FOUND IN SRM. REMOVED PART IAW SRM 51-40-02-0G-0, LOCATED & DRILLED HOLES AT NEW STRAP IAW SRM 51-40-05-0G-0. REMOVED AND INSTALLED THE NEW STRAP IAW SRM 51-40SDR V0XD20210606006Angle · corrodedPASSENGER DOOR SURROUND STRUCTURE, THE KICK ANGLE IS CORRODED. CORRECTIVE ACTION: REMOVED AND REPLACED KICK ANGLE(PN:SH670-31875-3S) IAW CRJ 900 SRM 51-21-23, 51-40-11, 51-40-00.SDR SWIA202158612Support Angle · crackedCARGO DOOR CUTOUT, UPPER BEAM AFT SUPPORT ANGLE IS CRACKED. FS 621.00 AT WL 115.08. (FILED CLOSED) REMOVED AND REPLACED CARGO DOOR CUTOUT, UPPER BEAM AFT SUPPORT ANGLE IN REF TO SRM 51-42-21. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLETED M-337.SDR ASAA2021052734938Baffle · corrodedAFT PIT BAFFLE CHANNEL STA 847 TO 867 IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED AFT PIT BAFFLE CHANNEL AT STA 847 TO 867 IAW B737-900 SRM 51-40-02-0G-0 W: 2 O: .040 R: 0 L: 2 D: .040.SDR SWAA2021060177663Floor Support · crackedFORWARD CARGO A/C DISTRIBUTION BAY FLOOR SUPPORT INTERCOSTAL CENTER LEFT IS CRACKED AT STA 540 ; / REMOVED AND REPLACED FLOOR SUPPORT PER AMM 20-50-11-201 AND SRM 51-40-02SDR SWAA2021060177664Floor Support · crackedFORWARD CARGO A/C DISTRIBUTION BAY FLOOR SUPPORT INTERCOSTAL CENTER RIGHT IS CRACKED AT STA 540 ; / REMOVED AND REPLACED FLOOR SUPPORT PER AMM 20-50-11-201 AND SRM 51-40-02SDR SWAA2021060177809Support Bracket · crackedAFT GALLEY SERVICE DOOR LINER PAN CRACKED ON FWD ATTACH SUPPORT ; / REMOVED AND REPLACED CRACKED PAN SUPPORT BRACKET I.A.W. SRM 51-40-02.SDR IPXA2021052769884Shear Web · corrodedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR SHEAR WEB SPLICE PLATE FROM STA440-560, LBL 50 HAS CORROSION OUT OF LIMITS. REPAIRED IAW UPS EO B757-5330-80324-A AND EA 757-5330-27-A2596 REV-.SDR R61A2021052700451Door Sill · corrodedWHILE IN HEAVY CHECK - AFT SERVICE DOOR SILL CORRODED AROUND AFT GIRT BAR FLOOR FITTING AS MARKED. REMOVED AND REPLACED AFT SERVICE DOOR LOWER BEAM REF: EMB SRM 51-40-08. RESTORED SURFACE PROTECTION TO AFT SERVICE DOOR CORNER RESTS, LOWER BEAM AND RH SHEAR PASDR R61A2021052700450Upper Sheet · corrodedWHILE IN HEAVY CHECK - CORROSION ON UPPER SHEET AT R/H FLOOR BEAM. NEAR FRAME 86. REMOVED AND INSTALLED NEW UPPER SHEET AT R/H FLOOR BEAM. REF SRM 51-40-08SDR R61A2021052700449Upper Sheet · corrodedWHILE IN HEAVY CHECK - CORROSION ON UPPER SHEET AT L/H FLOOR BEAM. NEAR FRAME 86. REMOVED AND INSTALLED NEW UPPER SHEET AT L/H FLOOR BEAM. REF SRM 51-40-08. PERFORMED.SDR R61A2021052700448Support Angle · corrodedWHILE IN HEAVY CHECK - CORROSION ON RIGHT HAND FUSELAGE INTERCOSTAL, UNDERFLOOR AFT OF FRAMES 90 AND 91. REMOVED AND REPLACED RIGHT HAND FUSELAGE INTERCOSTAL, UNDERFLOOR AFT OF FRAMES 90 AND 91. RESTORED SURFACE PROTECTION. REF EMB SRM 51-40-- 08, 51-23-06SDR R61A2021052700447Shear Panel · corrodedDURING HEAVY CHECK - CORROSION ON, L/H SHEAR PANEL, VARIOUS AREAS BETWEEN FRAME 87-88. AS MARKED. REMOVED AND INSTALLED NEW L/H SHEAR PANEL BETWEEN FRAME 87-88. REF SRM 51-40-08.SDR SIMA20210527001Receptacle · crackedSTIFFENER ON AFT SIDE OF FRAME 68 FOR CARGO DOOR HOLD OPEN RECEPTACLE HAS A 1/2" CRACK-C/A-INSTALLED NEW STIFFENER IAW SRM 51-40--02SDR JR2R20210527691Doubler · corrodedDOUBLER FWD OF R1 DOOR ON FLOOR STRUCTURE CORRODEDSDR SWAA2021070177818Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED BS380 TO BS400 ON BL 0 AT FWD GALLEY AREA. REPLACED ANGLE-SUPPORT LOC. BTW BS 380 TO BS 400 AND BL 0 FWD GALLEY AREA I.A.W. B737-700 SRM 51-10-02 TEM 9 AND DRAWING #143A5400 REV 'D'.SDR SWAA2021070177820Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS847 TO BS867 AT LBBL22 AT AFT GALLEY AREA (1 EA). REPAIRED WEB-INTERCOSTAL FLOOR STRUCTURE LOCATED BS 847 TO BS 867 AT LBBL 22 AT AFT GALLEY AREA IAW EA 21-153-01653.SDR SWAA2021070177821Angle · crackedCRACK ANGLE - SUPPORT LOCATED BS380 TO BS400 ON RBL 42 AT FWD GALLEY AREA (1 EA) ; 2021-255218 / [01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 22-JAN-22. TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DSDR SWAA2021063077766Floor Support · corrodedAFT CARGO FLOOR SUPPORT AT STRINGER 25L 'Z' CHANEL IS CORRODED B/S 700-847 ; / [01] REMOVED AND REPLACED Z-CHANNEL IAW B737-7 SRM 51-40-02-0GH-0; [02] VERIFIED INSTALLATION OF Z-CHANNEL.SDR SWAA2021063077764Floor Support · corrodedAFT CARGO RIGHT FLOOR SUPPORT 'Z' CHANNEL AT STRINGER 25R IS CORRODED AT 700-767 ; / [01] REMOVED CORROSION AT AFT CARGO R/H ZEE CHANNEL FROM 727 TO767 AS PER B737-700 SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS DUE TO EXFOLIATION CORROSION AS PER B737-700 SRSDR SWAA2021063077763Floor Support · crackedFWD PASSENGER COMPARTMENT FLOOR STRUCTURE;SHOWS INTERCOSTAL UPPER MID SURFACE CRACKED;BETWEEN B.S.312 AND B.S.328 RBL 32.0 W/L 207.54 ; / [01] INSTALLED EWIS PROTECTION IN AREA AT EAT 312 TO 328 RBL 32.0 REF B-737 700 AMM 20-60-07-913-801; [02] VERIFIED. EWIS SDR ASAA2021052635154Channel · corrodedAFT CARGO L/H TRANSITION PANEL STA 727 TO 787 CORRODED. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS FOUND TRANSITION PANEL SIDE PLATE ZEE TO BE OUT OF LIMITS IAW B737-900 SRM 53-00-53-1A-2 REPAIRED TRANSITION PANEL IAW B737-900 SRM 53-00-53-2R-5 REPAISDR SWAA2021062877519Panel · chafedPANEL 192DR HAS CHAFING DAMAGE AT I/B EDGE / [01] VERIFIED APPLICABILITY OF SRM 53-40-70-OI-1 FOR IDENTIFICATION AND SRM 53-40-70-1A-1 FOR ALLOWABLE DAMAGE; [02] DAMAGE FOUND ON PANEL 192DR ON WING TO BODY FAIRING AT I/B EDGE; 5'X0.6'X0.020'; ORIGINAL THICKNESSDR IPXA2021062470927Adapter · corrodedINSPECTION TYPE:SEGMAIN COMPARTMENT SEAT TRACK CLS FITTING AT FR 33 Y-6 HAS CORROSION.REMOVED AND REPLACED CLS ADAPTER PER EO# A300-5310-80603-ASDR REXA2021062400459Support · crackedAFT EQUIP. BAY DOOR CUTOUT LH SIDE SUPPORT STRUCTURE IS CRACKED. REMOVED AND REPLACED AFT EQUIPTMENT BAY DOOR CUTOUT L/H SIDE SUPPORT STRUCTURE IAW CRJ200 SRM 51-42-06.
Back to JASC 5320