JASC 5321
Service difficulty reports · 49,369
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021122345978Floor Panel · delaminatedAFT CABIN WET AREA FLOOR PANEL # 241ABF EDGE DELAMINATED AND SEVERAL DAMAGED INSERTS MKD ; / [01] REPAIRED DELAMINATED AREA AND REMOVED & REPLACED DAMAGED INSERTS AT FLOOR PANEL 241ABF. REF B737-700 SRM 53-00-50-2R-0; SRM 53-00-50-2R-9 PARAGRAPH 4 AND SRM 53-0SDR YENA2021113000822Doubler · corrodedDURING HEAVY MAINTENANCE, INITIAL INSPECTION(CPCP FINDING): CORROSION ON DOUBLER FLOOR STRUCTURE W1 (UNDER FWD. LAVATORY).; SUMMARY OF TOMEX WO 1708 NRC 00371: DOUBLER FLOOR STRUCTURE W1 (UNDER FWD. LAVATORY) WAS REPLACED PER EMB 190 SRM 51-41-02 PAR.4 &PAR.6;SDR YENA2021113000809Seat Track · corrodedDURING HEAVY MAINTENANCE, INITIAL INSPECTION: (CPCP FINDING RELATED R.C. 53-23-005-0417).CORROSION IN FASTENERS PERIPHERY OF CENTER SEAT TRACK LOCATED @ Y=300 AND BTWN FR 84-85 IN C.F.III PASSENGER CABIN FLOOR STRUCTURE.; SUMMARY: SEAT TRACK LOCATED AT Y=300.0SDR YENA2021113000798Floor Support · corrodedDURING HEAVY MAINTENANCE, INITIAL INSPECTION: (CPCP FINDING): CORROSION ON DOUBLER FLOOR STRUCTURE W1 (UNDER FWD. LAVATORY).; SUMMARY TOMEX WO 1708 NRC 00371: DOUBLER FLOOR STRUCTURE W1 ( UNDER FWD LAVATORY) WAS REPLACED PER EMB 190 SRM 51-41-02 PAR.4 & PAR.6.SDR DALA2021112207150None · noneCORROSION ON MEMBRANE FROM STA Y=184 TO Y=200 BTW X=-50 AND X=-53 AT W1 AREA. (CPCP CARD 2021-2001). SUMMARY OF NRC 00199: CORROSION LEVEL 2, REPAIR WAS PERFORMED ON MEMBRANE FROM STA Y=184 TO Y=200 BTW X=-50 AND X=-53 AT W1 PER B717 SRM 51-70-10-2R PROCEDURE SDR DALA2021111907143None · noneSHIP 192 AFT CARGO COMPARTMENT FOUND FRAME WEB UPPER CHORD SURFACE CORROSION AT STA1197+66 BETWEEN S-34R AND S-35R. CORRECTIVE ACTION: THE CORROSION AREA REPAIRED AS PER B767-300 SRM53-00-07-2R-4 (2023028)SDR SWIA202163521None · crackedCOCKPIT BEAM AT RBL12.00 JUST FWD OF FS280 IS CRACKED. (C-CHECK RO 1/7/2022) REMOVED AND INSTALLED NEW COCKPIT RBL 12.00 FLOOR BEAM SECTION -34, AND REINSTALLED PRE EXISTING REPAIR PARTS -36, -38, -40, -42 IAW CRJ700 SRM 53-11-43-201-003-A01 TYPE 4 REPSDR SWAA2021121345628Floor Panel · elongatedELONGATED HOLE FLOOR PANEL 231ZF AT PASSENGER CABIN ; 2021-525936 / [01] TOOL USED: HOT BONDER; P/N: HCS9200B; S/N: 18175478; DUE DATE: 05/AUG/22.; [02] TOOL USED: SCALE PN: SCA-301; SN: AE-412132 DUE DATE: 24/FEB/22.; [03] TOOL USED: HOT BONDER P/N: HCS9200B SDR DALA2021111907133None · noneSHIP 3266 AFT CABIN UTILITY AREA FLOOR BEAM Y1292 AT FR 68 HAS CORROSION. CORRECTIVE ACTION: R/R AFT CABIN FLOOR BEAM PER A320 SRM 51-42-11. (2022410)SDR DALA2021111907132None · noneCORROSION ON AFT CARGO DOOR JAMB (CCT). SUMMRY OF NRC 00030: CORROSION LEVEL 2, DOOR JAMB WAS REPAIRED (PERMANENT REPAIR) PER B717 SRM 53-20-15-2R PROCEDURE 7. (LP #2022650)SDR DALA2021111907131None · none1R DOOR AFT GIRT BAR FITTING HAS CORROSION. SUMMARY SEE NRC 042-0023:5310-2005/006 00274: 1R DOOR AFT GIRT BAR FITTING CORROSION FOUND TO BE BEYOND LIMITS PER B717 SRM 53-00-00-1A FIG 103. 1R DOOR AFT GIRT BAR FITTING WAS REPLACED WITH NEW PART REF BOEING DWG SDR SWIA202163883None · cracked*CRACK ON COCKPIT RH FLOOR BEAM RBL 12 FWD OF FS 280.00 (C CHECK RO 1/18/2022) REPAIRED CRACK ON COCKPIT RH FLOOR BEAM RBL 12 FWD OF FS 280.00 REFCRJ 700 SRM 53-11-43-201-003-A01 REPAIR IVSDR SWIA202163882None · cracked*CRACK ON COCKPIT LH FLOOR BEAM LBL 12 FWD OF FS 280.00 (C CHECK RO 1/18/2022) REPAIRED COCKPIT LH FLOOR BEAM LBL 12 FWD OF FS 280.00 REF CRJ700 SRM 53-11-43-201-003-A01 REPAIR TYPE IV. COMPLIED WITH TASK CARD 51-900-1002-SKY AND FORM M-337. SEE CONTINUESDR SWAA2022010444684Floor Panel · delaminatedFLOOR PANEL 241DF UPPER SURFACE DELAMINATED ; / [01] RECEIVED NEW FLOOR PANEL 241DF P/N 144A5810-128 P/O:1728471 REF. TASK CARD TTG8Q006QHHG FOR PANEL INSTALLATION; [02] VERIFIED STEP 1SDR SWAA2022010445113Floor Panel · delaminatedFLOOR PANEL 241DF UPPER SURFACE DELAMINATED ; / [01] RECEIVED NEW FLOOR PANEL 241DF P/N 144A5810-128 P/O:1728471 REF. TASK CARD TTG8Q006QHHG FOR PANEL INSTALLATION; [02] VERIFIED STEP 1SDR DALA2021112107146None · none(LOG 2021498) DURING INSPECTION FOUND CORROSION INSIDE STR 28R STA 500-500A. CORROSION LEVEL 2 INSIDE STR 28R STA 500-500A WAS REPAIRED PER ER/A 595445-14 REV. ORIGINAL AND ETI-37-21-513 REV. 2.SDR FDEA202111172884Floorboard · delaminatedCOURIER AREA FLOOR BOARD 221AF IS DELAMINATED. FABRICATED FLOOR BOARD 221AF ON VT MAE TRAVELER # T21/1582665 IAW DWGSRZ-25-005 REVISION R. MAJOR REPAIRSDR FDEA202111172883Floor Panel · delaminatedCOURIER AREA FLOOR PANEL 221BF IS DELAMINATED. FABRICATED FLOOR BOARD 221BF ON VT MAE TRAVELER # T21/1582643 IAW DWG SRZ-25-005 REVISION R. MAJOR REPAIRSDR DALA2021111807117None · noneSHIP 3257 CORROSION RAIL DUMMY Y503.2 AT LEVEL FR16 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED RAIL DUMMY PER A320 SRM 51-42-11, AND A320 SRM 51-72-11. (2021134)SDR DALA2021111807116None · noneSHIP 3257 CRACK RAIL DUMMY -Y189 AT LEVEL FR24 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED RAIL DUMMY PER A320 SRM 51-72-11 AND 51-42-11. (2021126)SDR SWAA2021122344336Floor Panel · delaminatedDELAMINATED FLOOR PANEL 231CF AT AT PASSENGER CABIN ; 2021-520517 / [01] REPLACED FLOOR PANEL 231CF AT AT PASSENGER CABIN IAW SOPM B737-700 AMM 53-21-00-400-801; [02] CORRECTED STEP 1: REPLACED FLOOR PANEL 231CF AT AT PASSENGER CABIN IAW AMM B737-700 AMM 53-21SDR SWAA2021121444761Panel · corrodedA125-03 FWD CARGO FLOOR PANEL 120CF CORRODED ; / [01] REMOVED CORROSION ON PANEL 120CF IAW SRM 51-10-02. PANEL IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIGURE 102. EXCEDES MAXIMUM LENGTH DAMAGE.; [02] INSPECTION VERIFIED OUT OF LIMITS; [03] VERIFIED MATERIAL 202SDR SWAA2021121444762None · corrodedA125-04 FWD CARGO FLOOR PANEL 120DF CORRODED ; / [01] REMOVED CORROSION ON PANEL 120DF IAW SRM 51-10-02. PANEL IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIGURE 102. EXCEDES MAXIMUM LENGTH DAMAGE.; [02] INSPECTION VERIFIED OUT OF LIMITS; [03] MATERIAL VERIFIED TO SDR SWAA2021121445182Floor Panel · corrodedA125-03 FWD CARGO FLOOR PANEL 120CF CORRODED. REMOVED CORROSION ON PANEL 120CF IAW SRM 51-10-02. PANEL IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIGURE 102. EXCEDES MAXIMUM LENGTH DAMAGE. INSPECTION VERIFIED OUT OF LIMITS IAW SRM 53-00-53-1A-1 STEP C. TRIMMED SDR SWAA2021121445183Floor Panel · corrodedA125-04 FWD CARGO FLOOR PANEL 120DF CORRODED ; / [01] REMOVED CORROSION ON PANEL 120DF IAW SRM 51-10-02. PANEL IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIGURE 102. EXCEDES MAXIMUM LENGTH DAMAGE.; [02] INSPECTION VERIFIED OUT OF LIMITS; [03] MATERIAL VERIFIED TO SDR SWAA2021111944359Floorboard · corrodedAFT CARGO COMPARTMENT FLOORBOARD 140EF L/H EDGE HAS SIGNS OF CORROSION. CORROSION FOUND TO BE LONGER THAN 20IN & DEEPER THAN .10IN OUT OF LIMITS. ALL WORK FOR AFT PIT FLOOR PANEL 140EF FABRICATION WAS ACCOMPLISHED ON TTG8Q009C1DC.SDR K11A2021111900084Floor Panel · corrodedPANEL CORROSIONSDR FDEA202111162868Floorboard · damagedUPPER MAIN DECK FLOOR BOARD PANEL (271BF)STA. 1321 LBL-50 REQUIRES FABRICATION. REMOVED AND REPLACED MAIN DECK FLOOR BOARD PANEL (271BF) STATION 1321 LBL50 REF FEDEX DWG SRZ-25-005.SDR HALA2021111800207Floor Panel · damagedSHIP 399 FWD CARGO PANEL 131WW HAS THROUGH DAMAGE AND A NON-CONFORMING REPAIR. CORRECTIVE ACTION: REPAIRED PER AMDS 2550-01315-03A. (2020210)SDR DALA2021111807115None · noneSHIP 3257 CORROSION FRAME 24 STRAP, STRINGER 39R IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: EVALUATED REWORK ON FRAME 24 STRAP, STRINGER 39R IN FWD CARGO COMPARTMENT AND FOUND WITHIN NEGLIGIBLE DAMAGE AS PER A320 SRM 51-73-11. OK FOR SERVICE. (2020320)SDR MASA20211117562None · noneLOWER FUSELAGE SKIN PANEL BETWEEN FS295.00 - FS310 AND STGR18R - STGR19R WAS FOUND TO HAVE A DENT. PERFORMED PERMANENT REPAIR JAW CRJ 700/900 SRM 53-21-01-001-002-A01, ITEM 1 AND E, EA 79-2021-254.SDR DALA2021111607061None · noneSHIP 192 FWD GALLEY SUPPORT FLOOR BEAM AT STA 287 RBL 62 FOUND CORROSION, CORRECTIVE ACTION: REPAIRED AS PER B767-300 SRM 53-00-51-2R REPAIR 1. (2019448)SDR SWAA2022010443983Floor Panel · deterioratedSUPPLEMENTAL INFORMATION: AFT CARGO COMPARTMENT;FLOOR PANEL 140AF IS DETERIORATED ; / [01] FABRICATED AFT CARGO FLOOR PANEL 140AF AS PER B737-700 AMM 25-52-01-201-801; [02] STEP 1 VERIFIEDSDR SWAA2021111944104Floor Panel · damagedFLOOR BOARD PANEL NUMBER 241DF POPPING ; FLOOR OARD PANEL NMER 241DF POPPING / [01] RE APPLIED FLOOR PANEL TAPE PER AMM 53-21-00.SDR SWAA000043059Floor Panel · crackedCRACK FLOOR PANEL 120BF AT FWD CARGO COMPARTMENT ; 2021-525701 / [01] REPLACED FLOOR PANEL 120BF AT FWD CARGO COMPARTMENT IAW B737-700 AMM 25-52-01-201-801 AND DRAWING #453A1610 SHEET 7 REV C; MATERIAL USED:2024 T3 THICKNESS 0.080 INCH PO# 2021 138258; [02] COSDR SWAA2021120643687Floor Panel · pulledPASSENGER CABIN FLOOR PANEL 241BF HAS FASTENER INSERT PULLED THROUGH AND HAS LAYER SEPARATION WITH LOOSE STRANDS. DUE TO EXTENT OF DAMAGE TO FLOOR PANEL; FABRICATED FLOOR PANEL. INSTALLED INSERTS, CURED INSERTS; APPLIED TAPE TO LOWER SURFACE IAW SRM 53-00-SDR SWAA2021120643688Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241AF HAS AREAS OF LAYER SEPARATION WITH LOOSE STRANDS. ; / [01] DUE TO EXTENT OF DAMAGE; FABRICATED NEW PANEL USING BMS 4-17 TY 6 LOT# 1473037-1; INSTALLED FASTENERS USING BMS 5-107 CL 1 LOT# AK0DP4051K; CURED INSERTS; APPLIED TAPESDR SWAA2021120643689Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 242BF HAS AREAS OF LAYER SEPARATION WITH LOOSE STRANDS. ; / [01] DUE TO THE EXTENT OF DAMAGE; BEGAN FABRICATION OF NEW PANEL CUT FROM BMS 4-23TY2 LOT#1472890-1; LOCATED AND DRILLED ALL INSERT LOCATIONS IAW SRM 53-00-50-2R-0 PARA 1A(SDR SWAA2021120643690Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 242AF HAS AREAS OF LAYER SEPARATION WITH LOOSE STRANDS. ; / [01] DUE TO THE EXTENT OF DAMAGE; BEGAN FABRICATION OF NEW PANEL CUT FROM BMS 4-23TY2 LOT#1472890-1; LOCATED AND DRILLED ALL INSERT LOCATIONS IAW SRM 53-00-50-2R-0 PARA 1A(SDR FDEA202111142928Floor Panel · damagedMAIN DECK CAGRO COMPT #231AH FLOOR PANEL WAS FOUND EDGE DAMAGED. ACCOMPLISHED THE FLOOR PANEL REPAIR I.A.W. A300-600F SRM 53-10-20-201, PARA. 8A, FIG. 201, P. 201-205.SDR AALA202111230670Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241MF IS DELAMINATED. **SUPPLEMENTAL REPORT FOR AALA202111150670: REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701. ** (CLOSED)SDR AALA202111234959Floor Panel · delaminatedAIRCRAFT ON BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 251PF IS DELAMINATED **SUPPLEMENTAL REPORT FOR AALA202111154959: REPLACED FLOOR PANEL PER SRM 53-02-00-011 AND IRM 9701 REV.1. ** (CLOSED)SDR FDEA202111142902Floor Panel · damagedMAIN DECK CAGRO COMPT #232NG FLOOR PANEL WAS FOUND EDGE DAMAGED. ACCOMPLISHED THE FLOOR PANEL REPAIR I.A.W. A300-600F SRM 53-10-20-201, PARA. 8A, FIG. 201, P. 201-205.SDR FDEA202111142901Floor Panel · damagedMAIN DECK CAGRO COMPT #231HH FLOOR PANEL WAS FOUND EDGE DAMAGED. ACCOMPLISHED THE FLOOR PANEL REPAIR I.A.W. A300-600F SRM 53-10-20-201, PARA. 8A, FIG. 201, P. 201-205.SDR FDEA202111142900Floor Panel · damagedMAIN DECK CAGRO COMPT #231CF FLOOR PANEL WAS FOUND EDGE DAMAGED. ACCOMPLISHED THE FLOOR PANEL REPAIR I.A.W. A300-600F SRM 53-10-20-201, PARA. 8A, FIG. 201, P. 201-205.SDR SWAA2021111843346Panel · delaminated193D PNL HAS FIBERGLASS DELAMINATION ON INSIDE TRAILING EDGE ; / [01] INSTALLED NEW PANEL (193D) PER AMM 53-21-21SDR DALA2021111507022None · noneSHIP 3266 MAIN CABIN TOP BEAM -Y765 AT FR-68 IS CORRODED AROUND FASTENER HOLE. CORRECTIVE ACTION: REPLACED WITH NEW FLOOR BEAM PER A320 SRM 51-42-11. (2017538)SDR DALA2021111507009None · none(LOG 2017696) DURING INSPECTION FOUND CORROSION ON FLOOR STG RBL 17.70 BTW STATION 500C AND 500D AT FWD CARGO COMPARTMENT. DAMAGE ON FLOOR STRINGER BEAM WAS REPAIRED PER B737-800 ER/A 501407-14MA REV. ORIGINAL SECTION I PARAGRAPH 1. AND B737-800 SRM 53-00-53 RSDR AALA2021111510670Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241MF IS DELAMINATED. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202111154959Floor Panel · delaminatedAIRCRAFT ON BASE MAINTENANCE: MAIN CABIN FLOOR BOARD 251PF IS DELAMINATED **SUPPLEMENTAL REPORT WILL BE SUBMITTED ** (OPEN)
Back to JASC 5321