SDR SWAA2021052619415Floor Panel · corrodedFORWARD CARGO PIT FLOOR PANEL 120CF HAS CORROSION ON UPPER OUTER EDGES. / EVALUATED CORROSION ON FWD CARGO FLOOR PANEL 120CF IAW B737 SRM 53-00-53-1A-1. FOUND TO BE OUT OF LIMITS EXCEEDS 20' OF CORROSION. FABRICATED; TREATED & PRIMED NEW PANEL IAW B737 AMM 25-SDR SWAA2021052619416Floor Panel · corrodedFORWARD CARGO PIT FLOOR PANEL 120AF HAS CORROSION ON UPPER OUTER EDGES. / EVALUATED CORROSION ON UPPER OUTER EDGES OF FORWARD CARGO PIT FLOOR PANEL 120AF; TOTAL ACCUMULATED DAMAGE LENGTH EXCEEDS THE 20' MAXIMUM - OUT OF LIMITS IAW SRM 53-00-53-1A-1; FABRICATEDSDR SWAA2021052619395Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL 140CF HAS CORROSION ON UPPER SURFACE AROUND OUTER EDGES OF PANEL. / AFT CARGO FLOOR PNL 140CF HAS CORROSION ON UPPER SURFACE AROUN OUTER EDGES. 'OUT OF LIMITS' DAMAGE EXCEEDS MAXIMUM DAMAGE OF 20' I/A/W SRM 53-00-53-1A-1 FIG 102. FABRSDR SWAA2021052619396Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL 140DF HAS CORROSION ON UPPER SURFACE AROUND OUTER EDGES OF PANEL. / FOUND CORROSION TO EXCEED 20' IN LENGTH AND IS OUT OF LIMITS. FABRICATED NEW AFT CARGO FLOOR PANEL 140DF I/A/W DRAWING 453A2610 REV B; AMM 25-52-01-201; SRM 53-00-53-SDR SWAA2021052619394Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL 140BF HAS CORROSION ON UPPER SURFACE AROUND OUTER EDGES OF PANEL. / MEASURED LENGTH OF DAMAGE TO BE = 55' LIMIT = 20'. PANEL 140BF IS OUT OF LIMITS AS PER SRM 53-00-53-1A-1. FABRICATED NEW PANEL IAW AMM 25-52-01-201-801 AND DWG: 453A2SDR SWAA2021052619393Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL 140EF HAS CORROSION ON UPPER SURFACE AROUND OUTER EDGES OF PANEL. / EVALUATED CORROSION ON UPPER SURFACE AROUND OUTER EDGES OF AFT CARGO PIT FLOOR PANEL 140EF; TOTAL ACCUMULATED CORROSION DAMAGE IS MORE THAN THE 20' MAXIMUM - OUT OF LSDR SWAA2021052619392Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL 140AF HAS CORROSION ON UPPER SURFACE AROUND OUTER EDGES OF PANEL. / FOUND CORROSION TO EXCEED LIMITS; MORE THAN 10' IN LENGTH. FOUND TO BE OUT OF LIMITS. REPLACED AFT CARGO FLOOR PANEL 140AF I/A/W AMMM 25-52-01-201; AMM 51-21-72-370; SDR SWAA2021033120264Floor Panel · dentedAFT FLOOR PANEL 241AEF UPPER SKIN HAS LARGE DENT NEAR CUT-OUT. (MARKED) REPAIRED LARGE DENT NEAR CUT-OUT ON UPPER SKIN AND ADDITIONAL PUNCTURE DAMAGE FOUND ON LOWER SKIN ON AFT FLOOR PANEL 241AEF IAW SRM 53-00-50-2R-2 AND SRM 53-00-50-2R-4.SDR FDEA202009292717Floor Panel · delaminatedDEBONDED FLOOR PANEL 161AF IN BULK CARGO COMPARTMENT BONDED DOUBLER ON FLOOR PANEL 161AF IN BULK CARGO COMPARTMENT, AS PER EA 6- 5317-T0357750 (P1), EA TITTLE: FUSELAGE AFT INTERMEDIATE SECTION-BULK CARGO COMPARTMENT-FLOOR PANELS 161AF AND 161GF-METALLIC DOUBSDR SWAA2020102820266Floor Panel · pulledAFT FLOOR PANEL 241YF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS. DUE TO THE EXTENT OF DAMAGE TO PANEL 241YF. REPLACED WITH NEW PANEL, IAW SRM 51-10-02-0G-0 PAR 9 AND AIPC 53-21-00-26 ITEM 66.SDR SWAA2020102820265Floor Panel · pulledAFT FLOOR PANEL 241XF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS. AFT FLOOR PANEL 241XF WITH UPPER SKIN HAVING MULTIPLE AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL, DUE TO AMOUNT OF ALL DAMAGE PER SRM 51-10-02-0G-0 PARA 9A (1).SDR SWAA2020102820271Floor Panel · damagedFWD FLOOR PANEL 221BF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS. DUE TO THE EXTENT OF DAMAGE TO PANEL 221BF REPLACED WITH NEW PANEL, IAW SRM 51-10-02-0G-0 PAR 9 AND AIPC 53-21-00-50D ITEM 50.SDR SWAA2020102820272Floor Panel · damagedFWD FLOOR PANEL 222BF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS. FWD FLOOR PANEL 222BF WITH UPPER SKIN HAVING MULTIPLE AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE, PER SRM 51-10-02-0G-0 PARA 9A (1).SDR SWAA2020102820273Floor Panel · damagedFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS. FWD FLOOR PANEL 222CF WITH UPPER SKIN HAS AREAS OF PULLED STRANDS WAS REPAIRED, IAW SRM 53-00-50-2R-1.SDR FDEA202009292575Floor Panel · crackedBROKEN FLOOR PANEL 162HF IN BULK CARGO COMPARTMENT. MANUFACTURED FLOOR PANEL 162 HF IN BULK CARGO COMPARTMENT, AS PER DRAWING SRZ-25-005 REV R AUG-22-2019. MARKED NEW FLOOR PANEL WITH P/N: A30A5327996200200 FX, AS PER GMM 7-0-1001, FOR TRACEABILITY P/O: 2020SDR FDEA202009292392Floorboard · delaminatedMAIN DECK FLOORBOARD HAS SMALL PUNCTURE, MARKED STA 1646 LBL 85. REPAIRED DAMAGE, REF SRM 53-60-00 FIG 6 PG 6 VOL I.SDR FDEA202009292376Floorboard · dentedMAIN DECK FLOORBOARD HAS SMALL INDENT IN SURFACE, MARKED STA 1105 LBL 85. REPAIRED INDENT IN SURFACE, PER SRM 53-60-00 VOL 1 FIG 7 PAGE 7.SDR FDEA202009292375Floorboard · dentedMAIN DECK FLOORBOARD HAS INDENT IN SURFACE, MARKED STA 1685 CENTERLINE. REPAIRED SMALL INDENT ON NOTED FLOORBOARD SURFACE, REF SRM 53-60-00 VOL 1 FIG 7 PG 7.SDR FDEA202009292374Floorboard · dentedMAIN DECK FLOOR PANEL HAS SMALL PUNCTURE, MARKED STA 1320 LBL 1. REPAIRED, PER SRM 53-60-00 VOL 1 FIG 7 PAGE 7.SDR FDEA202009292373Floorboard · dentedMAIN DECK FLOORBOARD HAS INDENT IN SURFACE, MARKED STA 1565 CENTERLINE. REPAIRED SMALL INDENT ON NOTED FLOORBOARD SURFACE, REF SRM 53-60-00 VOL1 FIG 7 PG 7.SDR FDEA202009292372Floorboard · dentedMAIN DECK FLOORBOARD HAS INDENT IN SURFACE, MARKED STA 1591 RBL 5. REPAIRED SMALL INDENT ON MAIN DECK FLOORBOARD SURFACE AT STA 1591 RBL 5, REF SRM 53-60-00 VOL 1 FIG 7 PG 7.SDR FDEA202009292370Floorboard · dentedMAIN DECK FLOORBOARD HAS INDENT IN SURFACE, MARKED STA 1631 LBL 7. REPAIRED PUNCTURE, PER SRM REF 53-60-00 FIG 7 PG7 VOL I.SDR FDEA202009292369Floorboard · dentedMAIN DECK FLOORBOARD HAS SMALL INDENT IN SURFACE, MARKED STA 1525 LBL 6. REPAIRED SMALL INDENT ON MAIN DECK FLOORBOARD SURFACE AT STA 1525 LBL 6, REF SRM 53-60-00 VOL 1 FIG 7 PG 7.SDR FDEA202009292367Floorboard · delaminatedMAIN DECK FLOORBOARD HAS INDENT IN SKIN, MARKED. STA 1510 AT CENTERLINE. REPAIRED DAMAGE, REF SRM 53-60-00 FIG 7 PG 7 VOL I.SDR FDEA202009292366Floorboard · delaminatedMAIN DECK FLOORBOARD HAS SMALL PUNCTURE, MARKED. STA 1441 CENTERLINE. REPAIRED DAMAGE, REF SRM 53-60-00 FIG 5 PG 5 VOL I.SDR SWAA2021052619931Floor Panel · corrodedCORROSION FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT BTW BS 767 TO BS 887 AND BTW S-25R TO S-25L WL 156.5 / REPLACED FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT BTW BS 767 TO BS 787 AND BTW STR 25R TO STR 25L AT WL 156.5 IAW SRM B737-700 51-40-05 SRM B737-700 5SDR FDEA202009282573Floor Panel · crackedCRACK FLOOR PANEL 151VF IN AFT CARGO COMPARTMENT. MANUFACTURED FLOOR PANEL 151VF IN AFT CARGO COMPARTMENT, AS PER DRAWING SRZ-25-005 REV R AUG-22-2019. MARKED FLOOR PANEL WITH P/N A30R532B114500000 FX, AS PER GMM 7-0-1001, FOR TRACEABILITY P/O: 2020-16157710SDR FDEA202009282590Floor Panel · crackedCRACK FLOOR PANEL 151MF IN AFT CARGO COMPARTMENT. MANUFACTURED FLOOR PANEL 151MF, AS PER DWG SRZ-25-005 REV R AUG-22-2019. MARKED NEW FLOOR PANEL P/N: FX A53279902000, AS PER DWG A53279915 ISSUE B SHEET 1 ITEM 0 AND GMM 7-0-1001 FOR TRACEABILITY MATERIAL P/OSDR IPXA2020093060815Floor Panel · delaminatedINSPECTION TYPE: A300 FLOOR PANEL 232SG DELAMINATED. FABBED PANEL 232SG FROM 5024N40000155-G, PER SREO A300-5320-40552-B.SDR AALA202010129027Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. FOUND DELAMINATED FLOOR PANEL 151QF FROM FR 58 TO FR 59, MEASURING L=11 IN, W=9 IN. REMOVED AND REPLACED FLOOR PANEL 151QF.SDR DALA2020092803206Floor Support · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BETWEEN FR 66 TO FR 68 Y1292 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM LOC BETWEEN FR 66 TO FR 68 Y1292 IN AFT GALLY AREA, AS PER SRM 51-72-11 AND DRAWING D53472000000, RELEASE DATE:06-JAN-03 ISSUE: DESDR FDEA202009272336Floorboard · damagedMAIN CABIN FLOORBOARD 242FFF HAS EDGE DAMAGE. REPAIRED MAIN CABIN FLOORBOARD 242FFF HAS EDGE DAMAGE, IAW FED EX B767-300 SRM 53-00-50-0I, 53-00-50-1A, AND 53-00-50-2R PARA 4B.SDR FDEA202009272335Floorboard · damagedMAIN CABIN FLOORBOARD 241LFF HAS EDGE DAMAGE. REPAIRED MAIN CABIN FLOORBOARD 241LFF HAS EDGE DAMAGE, IAW FED EX B767-300 SRM 53-00-50-1A AND 53-00-50-2R PARA 4B.SDR SWAA2020102023802Floor Panel · delaminatedCABIN FLOOR PNL 241AF HAS DELAMINATION SEVERAL AREAS. R & R PANEL 241 AF, PER AMM 53-21-00.SDR SWAA2020102822698Floor Skin · dentedFLIGHT DECK FLOOR IS DENTED AT BS 255, LBL 14, WL 207.45. REPAIRED DENTED FLIGHT DECK FLOOR AT BS 255 LBL 14 WL 207.45, IAW EA 1-A53-33179 REV 1.SDR FDEA202009252328Floor Panel · corrodedAFT CARGO PANEL 161CF BOTTOM SIDE HAS CORROSION. FABRICATED 161CF FLOOR PANEL ON VTMAE TRAVELER NR T20/1512947, IAW DWG SRZ-25-005 REV R, MAJOR REPAIR.SDR SWIA202053876Floor Skin · corrodedLT PRESSURE FLOOR SILL SKIN AT FS 518.00 AND FS 522.00 IS CORRODED. C-CHECK RO 11/11/2020. REPAIRED LT PRESSURE FLOOR SILL SKIN AT FS 518.00 AND FS 522.00 CORROSION, IAW BOMBARDIER REO. REFERANCE CONTINUATION FOR WORK PERFORMED.SDR SWAA2020101420637Floor Panel · damagedPASSENGER CABIN FLOOR PANEL 242DF HAS DAMAGE TO AFT EDGE; 3' FROM IB EDGE. MARKED / PASSENGER CABIN FLOOR PANEL 242DF WITH DAMAGE AT AFT EDGE; 3' FROM I/B EDGE WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.(1). DUE TO AMOUNT OF ALLSDR SWAA2020101420636Floor Panel · damagedPASSENGER CABIN FLOOR PANEL 241FF HAS DAMAGE ON UPPER SURFACE 19.5' FROM AFT EDGE; 5' FROM IB EDGE. MARKED / PASSENGER CABIN FLOOR PANEL 241FF WITH DAMAGE ON UPPER SURFCE 14.5' FROM AFT EDGE; 5' FROM I/B EDGE WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL USSDR SWAA2020101420635Floor Panel · damagedPASSENGER CABIN FLOOR PANEL 241BF HAS DAMAGE TO AFT EDGE 9' FROM IB EDGE. MARKED / DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW PASSENGER CABIN FLOOR PANEL 241BF USING BMS 4-23 TY 2 LOT # 1437364-1; INSTALLED INSERTS USING BMS 5-107 LOT # AK9GP5303K; PART MARKESDR SWAA2020101420634Floor Panel · damagedPASSENGER CABIN FLOOR PANEL 241CF HAS DAMAGE ON UPPER SURFACE 5' FROM AFT EDGE; 9' FROM IB EDGE MARKED / PASSENGER CABIN FLOOR PANEL 241CF WITH DAMAGE ON UPPER SURFACE 5' FROM AFT EDGE; 9' FROM I/B EDGE WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL USING BMSDR SWAA2020101420633Floor Panel · damagedPASSENGER CABIN FLOOR PANEL 231ZF HAS DAMAGE ON UPPER SURFACE ALONG FWD EDGE MARKED / DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW PASSENGER CABIN FLOOR PANEL 231ZF USING BMS 4-23TY2 LOT #1437364-1; INSTALLED INSERTS USING BMS 5-107 LOT # AK9GP303K; PART MARKEDSDR SWAA2020101420628Floor Panel · crackedFLOOR PANEL SUPPORT IS CRACKED AT BS 540 BETWEEN BL 0-LBL 24.5 WL 208 / RMEOVED AND REPLACED CRACKED FLOOR PANEL SUPPORT AT BS 540 BETWEEN 0.0 LBL - 24.5. WL 208 IAW DWG 143A0060SDR FDEA202009242311Floor Support · crackedLOWER BULK CARGO COMPARTMENT STATION 1937 RIGHT BUTT LINE 41.5 FLOOR PANEL STRINGER FOUND CRACK, AS MARKED. LOWER BULK CARGO COMPARTMENT STATION 1937 RIGHT BUTT LINE 41.5 FLOOR PANEL CRACKED. STRINGER REPAIRED, AS PER B777 SRM 53-70-53-2R FIGURE 202 REPAIR 2SDR IPXA2020092460595Floorboard · damagedINSPECTION TYPE: SEG 3 MAIN CARGO COMPT LOWER RIGHT FLOORBOARD AT STA 1060-1100 UPPER FRONT END IS BENT UPWARDS. DOT NR 47-37 FABBED PANEL AT STA 1060-1100 FRONT 5024 N 40000155-G, BATCH 3546253, PER SREO B757-5320-9692-K.SDR FDEA202009232300Floor Panel · delaminatedCABIN, MAIN DECK CARGO COMPARTMENT FLOOR PANEL NUMBER 252UF AT STATION 6-70 TO STATION 1159 FOUND EDGE DELAMINATED. DELAMINATED FLOOR PANEL 252UF AT CABIN STATION 6-70 TO STATION 1159 REMOVED, AS PER AMM 53-21-04. FLOOR PANEL 252UF FABRICATED, AS PER FEDEX DSDR FDEA202009232299Floor Panel · delaminatedCABIN, MAIN DECK CARGO COMPARTMENT FLOOR PANEL NUMBER 252EF AT STATION 1099 TO STATION 6-70 FOUND EDGE DELAMINATED. DELAMINATED FLOOR PANEL 252EF AT CABIN STATION 1099 TO STATION 6-70 REMOVED, AS PER PER AMM 53-21-04. FLOOR PANEL 252EF FABRICATED, AS PER FESDR FDEA202009232301Floor Panel · delaminatedCABIN, MAIN DECK CARGO COMPARTMENT FLOOR PANEL NUMBER 231HF AT STATION 595 TO STATION 675 FOUND DELAMINATED. DELAMINATED FLOOR PANEL 231HF AT CABIN STATION 595 TO STATION 675 REMOVED, AS PER AMM 53-21-04. FLOOR PANEL 231HF FABRICATED, AS PER FEDEX DRAWING SRSDR FDEA202009232297Floor Panel · delaminatedCABIN, MAIN DECK CARGO COMPARTMENT FLOOR PANEL NUMBER 231LF AT STATION 675 TO STATION 735 FOUND DELAMINATED. DELAMINATED FLOOR PANEL 231LF AT CABIN STATION 675 TO STATION 735 REMOVED, AS PER AMM 53-21-04. FLOOR PANEL 231LF FABRICATED, AS PER FEDEX DRAWING SRSDR IPXA2020100360880Floor Panel · damagedINSPECTION TYPE: A300 AVI COMPARTMENT FLOOR PANEL 121QF HAS UPPER CORNER SKIN MISSINGS, REO A300-5320-42722.
Back to JASC 5321