SDR FDEA201602190646Floor Panel · crackedMAIN CABIN DECK FLOOR PANEL 251BH CRACKED. FABRICATED FLOOR PANEL 251BH ON T16 1188531 IAW SRZ 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201602190645Floor Panel · damagedMAIN CABIN FLOOR PANEL 252NG DAMAGED. FABRICATED FLOOR PANEL 252NG ON T16 1188123 IAW SRZ 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201602190644Floor Panel · damagedMAIN CABIN FLOOR PANEL 252BF DAMAGED. FABRICATED FLOOR PANEL 252BF ON T16 1188124 IAW SRZ 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201602190643Floor Panel · damagedMDC FLOOR PANEL 252PH HAS DAMAGE. FABRICATED FLOOR PANEL 252PH ON T16 1189372 IAW SRZ 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201602190642Floor Panel · damagedMDC FLOOR PANEL 252UH HAS DAMAGE. FABRICATED FLOOR PANEL 252UH ON T16 1189387 IAW SRZ 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201602190641Floor Panel · damagedMAIN DECK COMPARTMENT, PANEL 251XG DAMAGED. FABRICATED FLOOR PANEL 251XG ON T16 1189792 IAW SRZ 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201602190639Floorboard · delaminatedMAIN CARGO DOORWAY, FLOORBOARD AT STATION 595, LBL 91 IS DETERIORATED, DELAMINATED & HAS MISSING OR BROKEN INSERTS. FABRICATED A NEW FLOORBOARD IAW SRZ-25-005.SDR IPXA2016022599921Floor Panel · damagedINSPECTION TYPE:C, MAIN EQUIPMENT CENTER FLOOR PANEL 119AF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW DWG 284N1033-20.SDR IPXA2016022599920Floor Panel · damagedINSPECTION TYPE: C, MAIN EQUIPMENT CENTER FLOOR PANEL 119FF IS DAMAGED SHOWING INNER CORE. FABRICATED A NEW FLOOR PANEL IAW DWG 284N1033-30.SDR AALA201602199010Floor Panel · damagedAIRCRAFT WAS NOT GNDED. AFT PIT FLOOR PANEL 151DF IS SOFT. REPLACED FLOOR PANEL IAW AMM 53-42-04.SDR AALA201602199008Floor Panel · damagedAIRCRAFT WAS NOT GNDED. AFT PIT FLOOR PANEL 151 PF IS SOFT. REPLACED FLOOR PANEL IAW AMM 53-42-04.SDR FDEA201602180625Floorboard · delaminatedMAIN CARGO FLOORBOARD AT STATION 1741, RBL 38 HAS DELAMINATION & MISSING INSERTS. FABRICATED NEW FLOORBOARD IAW SRZ-25-005.SDR IPXA2016022599925Floor Panel · puncturedINSPECTION TYPE:10YR, AFT CARGO FLOOR PANEL 151VF HAS A PUNCTURE ON BACK SIDE. REPAIRED IAW E0 A300-5320-42722-E.SDR IPXA2016022699941Floor Panel · damagedINSPECTION TYPE:1C2C, FWD CARGO FLOOR PANEL 132PG HAS EDGE DAMAGE. REPAIRED THE FLOOR PANEL IAW SREO A300-5320-42721-F.SDR IPXA2016022699940Floor Panel · damagedINSPECTION TYPE:1C2C, FWD CARGO FLOOR PANEL 132AH HAS EDGE DAMAGE. REPAIRED THE FLOOR PANEL IAW SREO A300-5320-42721-F.SDR IPXA2016022699938Floor Panel · damagedINSPECTION TYPE: 1C2C, FWD CARGO BAY FLOOR PANEL132QG HAS EDGE DAMAGE. REPAIRED THE FLOOR PANEL 132QG IAW SREO A300-5320-42721-F.SDR IPXA2016022699937Floor Panel · damagedINSPECTION TYPE:1C2C, FWD PIT FLOOR PANEL 132MG HAS EDGE DAMAGE. REPAIRED FLOOR PANEL 132MG IAW SREO A300-5320-42721-F.SDR IPXA2016022299763Floor Panel · puncturedINSPECTION TYPE:10YR, AFT FLOOR PANEL 151TF HAS PUNCTURE ON BACK SIDE REPAIR IAW EO NR 5320-42722-E AND SRM 53-10-20-201, 51-77-10 / 51-77-11.SDR FDEA201602170613Floorboard · delaminatedMAIN CARGO FLOORBOARD AT STATION 1821, RBL 38, PANEL DAMAGED. FABRICATED NEW FLOORBOARD IAW DWG SRZ-25-005.SDR FDEA201602170610Floorboard · damagedMAIN CARGO FLOORBOARD, STATION 1481, LBL 38, DAMAGED. FABRICATED NEW FLOORBOARD IAW SRM 53-60-00 VOL 1 & DWG SRZ 25-005.SDR IPXA2016022699931Floor Panel · damagedINSPECTION TYPE: 5YR, ELECTRONIC EQUIPMENT COMPARTMENT FLOOR PANEL HAS 2 INSERTS. PULLED OUT AND EDGE DAMAGE REPAIRED PANEL IAW SRM 51-77-10, 51-77-11.SDR AALA201602199009Floor Panel · damagedAIRCRAFT WAS NOT GNDED. AFT PIT FLOOR PANEL 51AF IS SOFT. REPLACED FLOOR PANEL IAW AMM 53-42-04.SDR AALA201602199007Floor Panel · damagedAIRCRAFT WAS NOT GNDED. AFT PIT FLOOR PANEL 61AF IS SOFT. REPLACED FLOOR PANEL IAW AMM 53-42-04.SDR IPXA2016031000580Floor Panel · delaminatedINSPECTION TYPE:1C2C, AFT CARGO FLOOR PANEL 161KF HAS 2 BAD INSERTS AND DELAMINATION BOTTOM SIDE. REPAIRED THE FLOOR PANEL IAW SREO A300-5320-42721-F.SDR IPXA2016022399813Floor Panel · crackedINSPECTION TYPE:1C2C, SUPERNUMERARY FLOOR PANEL 222KG IS CRACKED. REPAIRED FLOOR PANEL 222KG IAW SREO A300-5320-42721-F.SDR IPXA2016030200264Floor Panel · crackedINSPECTION TYPE:10YR, FWD CARGO FLOOR PANEL 1315G HAS CRACK ON BACK SIDE. REMOVED DAMAGED AREA, FILLED AREA WITH EPOXY EA934 A/B IAW SRM 51-77-11.SDR DALA2016021501075Cusp Web · misrepairedMISINSTALLED PREVIOUS REPAIR OR RT CUSP WEB AT BS 788-807 BETWEEN TRACK X=54/ X=60. PREVIOUS REPAIR WAS REPLACE IAW SRM 53-05, FIG 131A-7.SDR DALA2016021501074Floor Panel · crackedCRACKS ON CHANNEL OF FLOOR PANEL. FLOOR PANEL REPAIRED. DOUBLERS WERE INSTALLED IAW SRM 53-05, FIG 131B, SHEET 3, SHEET 1, 2, 3 FIG 131C.SDR IPXA2016030100233Floor Panel · puncturedINSPECTION TYPE:10YR, PANEL 132QG IS PUNCTURED. REPAIRED PANEL IAW EO A300-5320-42721-F.SDR IPXA2016030100232Floor Panel · damagedINSPECTION TYPE:10YR, PANEL 132PG HAS EDGE DAMAGE. REPAIRED PANEL IAW EO A300-5320-42721-F.SDR IPXA2016030100217Floor Panel · puncturedINSPECTION TYPE:1C2C, PANEL 131MG HAS SEVERAL PUNCTURES. REPAIRED FLOOR PANEL IAW EA A300-5320-42721-F.SDR DALA2016021401154Floor Panel · corrodedAFT CABIN FLOOR PANEL 262FF HAS CORROSION. REPLACED THE FLOOR PANEL IAW SRM 51-72-11.SDR DALA2016021701149Floor Panel · damagedAPPROXIMATELY ONE INCH DIA HOLE IN AFT CARGO BAY FLOOR 18 IN INBD OF DOOR SILL AND 3 IN FWD OF FWD DOOR CUTOUT. ACCOMPLISHED ERA 489384-14MA, REV F SECTION, I MUST ACCOMPLISH SECT III SPPED TAPE REPAIR INSPECTION EVERY 50 FLT HRS AND SECT II TEMPOARY REPAIR DSDR DALA2016021601090Floor Panel · delaminatedDELAMINATED FLOOR PANEL IN MAIN CABIN. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR SWAA2016022349303Splice · corrodedAFT CARGO COMPARTMENT, FLOOR PANEL T SPLICE, CORRODED AT BS 727D+4. R & R T SPLICE IAW SRM.SDR IPXA2016021399306Floor Panel · damagedFLOOR PANEL AT MIDDLE POSITION AT BS 1695 DAMAGED, REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2016021399305Floor Panel · damagedMAIN DECK FLOOR PANEL MIDDLE POSITION AT BS 1736 DAMAGED. REPAIRED, IAW SRM 53-00-50-2R.SDR A6WA201643564Floor Panel · crackedLEFT FWD EQUIPMENT BAY FLOOR CRACKED AT FS 193.00. REPAIRED IAW REO 601R-53-11-081 REV NC.SDR AALA201602159008Floor Panel · debondedAIRCRAFT IN BASE MX. PANEL 221 LT HAS TOP LAYER DISBONDED. REMOVED & INSTALLED NEW PANEL 221 LT IAW AMM 53-12-12.SDR DALA2016021201007Floor Panel · crackedCRACKED FLOOR PANEL 1307B. THE FLOOR PANEL WAS FABRICATED IAW AMM 53-20-01-201.SDR AALA201602119007Floor Panel · corrodedAIRCRAFT IN BASE MX. CORROSION ON FLOOR PANEL 222FF AROUND INSERT HOLES. REPLACED FLOOR PANEL IAW AMM 53-12-12.SDR AALA201602119006Floor Panel · delaminatedAIRCRAFT IN BASE MX. FLOOR PANEL 221EF. REPLACED FLOOR PANEL IAW AMM 53-12-12.SDR AALA201602119005Floor Panel · delaminatedAIRCRAFT IN BASE MX. FLOOR PANEL 222EF, UPPER SURFACE IS DELAMINATED. REPLACED FLOOR PANEL IAW AMM 53-12-12.SDR DALA2016021100981Ferrule · damagedDAMAGE FERRULES ON FLOOR PANEL. DAMAGE FERRULE REPLACED IAW AMM 53-20-01-201.SDR R61A201602080095Doubler · corrodedDURING HEAVY CHECK, LT FLOOR DOUBLER FRAMES 13-16 IS CORRODED. MAINTENANCE R & R LT FLOOR DOUBLER FRAME 13-16 IAW SRM 170/175 51-40-02, 51-23-04, PN 170-12118-001, DOUBLER.SDR AALA201602099001Floor Panel · damagedAIRCRAFT WAS NOT GNDED. FWD GALLEY FLOOR HAS A SOFT SPOT. R & R FLOOR PANEL 222EF IAW AMM 53-12-12.SDR IPXA2016020798984Floor Panel · damagedFLOOR PANEL DAMAGED. FABRICATED A NEW FLOOR PANEL IAW EO B767-5320-9693-I.SDR ASOA2016020614500Floor Panel · corrodedCORROSION FOUND ON PRESSURE FLOOR JUST FWD OF FS 559 ON RT SIDE. BLENDED CORROSION FWD OF FS 559 ON CROSSBEAM ABOVE PRESSURE FLOOR IAW SRM 51-21-06-00. EVALUATED BLEND AREA FOUND TO BE ON STEP AT FS 559.00 BETWEEN RBL36-RBL45 OUT OF ALLOWABLE DAMAGE LIMITS ISDR DALA2016020700935Pressure Deck · crackedCRACK INDICATION FOUND ON FASTENER HOLE LOCATED AT FRAME 36 PRESSURE DECK Y1497, FORWARD CARGO COMPARTMENT, PERFORMED TIME LIMITED REPAIR LOCATED ON HOLE AT FRAME 36, PRESSURE DECK Y-1347 FWD CARGO COMPARTMENT IAW ERA 542042-14AD, REV ORIGINAL AND PRI 542042-1SDR DALA2016020700934Pressure Deck · crackedCRACK INDICATION FOUND ON FASTENER HOLE LOCATED AT FRAME 36, PRESSURE DECK Y1497, FORWARD CARGO COMPARTMENT. PERFORMED TIME LIMITED REPAIR LOCATED ON HOLE AT FRAME 36 PRESSURE DECK Y-1422 FORWARD CARGO COMPARTMENT IAW ERA 542042-14AD, REV ORIGINAL AND PRI 542
Back to JASC 5321