JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3580180Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 251XFF DELAMINATED AND MISSING INSERT FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580179Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 242XEF DELAMINATED IN THE CORNER FABRICATED NEW FLOOR PANEL IAW SREO B757-5370-9692-H.SDR IPXA3580176Floor Panel · damagedDURING C-8, MAIN CABIN FLOOR PANEL 232XTF FOUND DAMAGED ON BOTTOM. FABRICATED NEW FLOOR PANEL IAW SREO B757-5370-9692-H.SDR IPXA3580173Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 242XFF DELAMINATED AND HAS EDGE DAMAGE FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-H.SDR IPXA3580142Floor Panel · damagedDURING C-8 INSPECTION, MAIN CABIN FLOOR PANEL 252XTF HAS EXCESSIVE EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580122Floor Panel · damagedDURING C-8 INSPECTION, MAIN CABIN FLOOR PANEL 231XSF DAMAGED ON BOTTOM. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3180152Floorboard · damagedINSPECTION TYPE:3C BULK CARGO FLOORBOARD 161GF HAS CRUSHED COMPOSITE MATERIAL AND MISSING TOP LAYER. FABRICATED BULK CARGO FLOORBOARD IAW EO A300-5320-16407-E, APPENDIX D.SDR AALA20130826005Floor Panel · corrodedCARGO FLOOR PANEL AT STATION 481.6 CORRODED. REPLACED FLOOR PANEL.SDR USAA2013091100025Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 151GF BETWEEN FRAMES 52 TO 56 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00 & IRM 9701, REV G.SDR CALA2013082690747Floorboard · damagedAISLE SOFT AT ROW 26 & 27. REMOVED & INSTALLED FLOOR BOARD AT ROWS 26 & 27 IAW AMM 53-01-01.SDR IPXA3B79982Floor Panel · damaged.6 DIA PUNCTURE IN MCD FLOOR PANEL AT FS 2077. REPAIRED IAW SRM 53-00-50-2R-1, REPAIR 1, PARA 4.C.SDR UHLA2013082300477Doubler · corrodedCORROSION, PAINT BUBBLED AFT OF BOTH COPILOT SEAT TRACKS ON FLOOR DOUBLER BETWEEN FRAMES 11 AND 12. R & R AFT SECTION OF RT AFT FLOOR DOUBLER.SDR UHLA2013082300416Doubler · corrodedLEVEL 2 CORROSION ON FLOOR DOUBLER FRAMES 19-20. R & R FLOOR DOUBLER.SDR USAA2013082700034Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261PF BETWEEN FRAMES 68 TO 70 & BETWEEN Y1732 TO -Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700033Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 262BG BETWEEN FRAMES 66 TO 68 & BETWEEN -Y765 TO -Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700032Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 262EF BETWEEN FRAMES 66 TO 68 & BETWEEN -Y1292 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700031Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 261EF BETWEEN FRAMES 66 TO 68 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700030Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261DF BETWEEN FRAME 66 TO 68 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700029Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261BG BETWEEN FRAMES 64 TO 66 & BETWEEN Y765 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700028Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232XF BETWEEN FRAMES 32 TO 35 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700027Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAMES 16 TO 21 & BETWEEN Y254 TO -Y254. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700026Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222EF BETWEEN FRAMES 16 TO 20 & BETWEEN -Y1292 TO -Y254. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700021Floor Panel · delaminated2S CHECK - DELAMINATION ON AFT CARGO FLOOR PANEL 151GF BETWEEN FRAMES 58 TO 59 & BETWEEN S32-38L. REPLACED AFT CARGO FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700008Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 151GF DELAMINATED, BEYOND SRM LIMITS 53-02-00 ZONE " B " DAMAGE. REPLACED FLOOR PANEL IAW AMM 53-42-14.SDR SWAA2013090920003Floor Panel · damagedMAIN CABIN FLOOR PANEL 222APF DAMAGED. R&R PANEL IAW MM.SDR IPXA3580107Floor Panel · damagedDURING S3C1 INSPECTION, FLOOR PANEL 232ZAF HAS TWO DENTS OF APPROXIMATELY 2" W X 5" L. THERE ARE CRACKS IN AND AROUND THE DENTED AREA OF THE SKIN. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580106Floor Panel · puncturedDURING S3C1 INSPECTION, FLOOR PANEL 251XEF TOP SURFACE PUNCTURED, FARICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580104Floor Panel · damagedDURING S3C1 INSPECTION, FLOOR PANEL 232XFF HAD SEVERAL AREAS OF EDGE DAMAGE ALONG THE FASTENER ROW, THE LOWER SURFACE OF THE PANEL, SEVERAL ARE CRACKED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580059Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XAF UPPER SURFACE IS DENTED AND PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR SWAA2013082919705Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 222 AVF DELAMINATED. R&R PANEL IAW SRM.SDR SWAA2013082919704Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 222 AHF DELAMINATED. REPAIRED PANEL IAW SRM.SDR SWAA2013082919703Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 222 ABF DELAMINATED. REPAIRED PANEL IAW SRM.SDR SWAA2013082919702Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 222 AGF DELAMINATED. REPAIRED PANEL IAW SRM.SDR SWAA2013082919701Panel · delaminatedMAIN CABIN FLOOR PANEL NR 222 ACF DELAMINATED. REPAIRED PANEL IAW SRM.SDR IPXA2013082835805Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 242XCF HAS BROKEN SCREW INSERTS. REPLACED INSERTS IN FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013082835803Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 241XCF HAS BROKEN SCREW INSERTS. REPLACED INSERTS IN MAIN CABIN FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013082835802Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 242XJF HAS BROKEN SCREW INSERTS. REPLACED INSERTS IN MAIN DECK FLOOR PANEL IAW EO B757-5320-9692- H.SDR SWAA2013082719606Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 222LF DELAMINATED. R&R PANEL IAW SRM.SDR USAA2013082700020Floor Panel · delaminated2S CHECK - AREA OF DELAMINATION ON FLOOR PANEL 231CF BETWEEN FRAMES 20 TO 24, Z-500 & BETWEEN Y765 TO Y254. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR SWAA2013082619600Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 223 DF DELAMINATED. REPAIRED PANEL IAW SRM.SDR USAA2013082300012Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL BETWEEN FRAMES 64 TO 66 & S21L TO S21R. REPLACED FLOOR PANEL IAW AMM 53-42-12-400-002-A.SDR USAA2013082300011Floor Panel · delaminatedFOUND DELAMINATION ON FLOOR PANEL 251WF BETWEEN FRAMES 62 TO 64 & S21L TO S21R. REPLACED FLOOR PANEL IAW AMM 53-42-12-400-001-A.SDR USAA2013082300006Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 262HG BETWEEN FRAMES 64 TO 66, Z-500 & -Y765 TO -Y1589. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR USAA2013082300005Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 241CF BETWEEN FRAMES 35.8 TO 36, Z-500 & -Y765 TO -Y1037. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR USAA2013082300004Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 222DF BETWEEN FRAMES 16 TO 20, Z-500 & -Y81 TO -Y503.2. REPLACED FLOOR PANEL IAW IRM 9701, REV. G.SDR USAA2013082300003Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 222CF BETWEEN FRAMES 12 TO 16, Z-500 & -Y1379.5 TO -Y81. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR DALA2013082300432Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON LOWER SILL AFT CABIN FLOOR STRUCT LOCATION AT FR 68 OUTER FLANGE LT SIDE MEASURED L=0.500", W=0.250" D=0.007" APPROXIMATELY PERFORMED PERMANENT REPAIR ON LOWER SILL AFT CABIN FLOUR STRUCT LOCATION AT FR68 OUTER FLANGE LT SSDR IPXA3580105Floor Panel · debondedDURING S3C1 INSPECTION, MAIN DECK FLOOR PANEL, 251XRF, BS 1680-1720 IS DISBONDED FROM HONEYCOMB. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580062Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XCF, BS 1200-1320 RT IS DELAMINATED AROUND UPPER SURFACE EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580061Floor Panel · puncturedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XQF, BS 1540-1600 RT IS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.
Back to JASC 5321