JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12011343132Floor Panel · puncturedFORWARD UTILITY FLOOR PANEL 222CF PUNCTURED AT SEVERAL LOCATIONS "3 X 3". FLOOR PANEL FABRICATED NEW IAW DWG 3D25-40640.SDR IPXA12176017Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 241BQ IS CRACKED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR USAA2012110600010Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 221EF BETWEEN FR16 TO FR20 & BETWEEN Y1292 TO Y254. REPLACED FLOOR PANEL 221EF IAW A319 SRM 53-12-00 FIG 206 & IRM 9701 REV G.SDR USAA2012110600009Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 252NF BETWEEN FR54 TO FR58 & BETWEEN -Y765 TO -Y1292. REPLACED FLOOR PANEL 252NF IAW A319 SRM 53-02-00 FIG 209 & IRM 9701 REV G.SDR USAA2012110600008Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 252SF BETWEEN FR58 TO FR62 & BETWEEN -Y254 TO -Y765. REPLACED FLOOR PANEL 252SF IAW A319 SRM 53-02-00 FIG 209 & IRM 9701 REV G.SDR USAA2012110600007Floor Panel · delaminated2S CHECK - DELAMINATION FLOOR PANEL 252GF BETWEEN FR51 TO FR54 & BETWEEN -Y254 TO -Y765. REPLACED FLOOR PANEL 252GF IAW A319 SRM 53-02-00 FIG 209 & IRM 9701 REV G.SDR FDEA201210233724Floor Skin · corrodedDURING REMOVAL OF CAPTIAN'S RT SEAT TRACK FOUND AREA OF CORROSION BS 245 TO 255 LBL 17 REPAIRED AREA IAW EA 5310-162556. CLASSIFIED AS A MAJOR REPAIR.SDR FDEA201210233723Floor Skin · corrodedDURING REMOVAL OF CAPTAIN'S RT FOOT HEATER PANEL FOUND AREAS OF CORROSION BS 205 TO 231 LBL-15. REPAIRED AREA IAW EA 5310-162556. CLASSIFIED AS A MAJOR REPAIR.SDR FDEA201210233721Floor Skin · corrodedCOCKPIT FLOOR SKIN AT BS 239-247, LBL30-40 CORRODED. REPAIRED AREA IAW EA 5310-162556. CLASSIFIED AS A MAJOR REPAIR.SDR FDEA201210233718Floor Skin · corrodedCOCKPIT FLOOR SKIN AT BS 239 - 247, RBL 34 HAS SCRATCHES AND CORROSION. REPAIRED AREA IAW EA 5310-162556. CLASSIFIED AS A MAJOR REPAIR.SDR FDEA201210233717Floor Skin · corrodedFLT DECK FLOOR SKIN FROM BS 225 TO 231, RBL 36 - 40, HAS CORROSION. REPAIRED AREA IAW EA 5310-162556. REPAIR IS CLASSIFIED AS A MAJOR.SDR DALA12010963132Floor Panel · corrodedFORWARD UTILITY FLOOR PANEL 222FF CORRODED ON LWR SURFACE 4.0" X 3.5". INSTALLED NEW FLOOR PANEL IAW SRM 51-72-00.SDR DALA12010953132Floor Panel · corrodedFORWARD UTILITY FLOOR PANEL 221FF CORRODED ON LOWER SURFACE 2.0" X 3.0". INSTALLED NEW FLOOR PANEL IAW SRM 51-72-00.SDR USAA2012111900018Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151VG BETWEEN FR53 TO FR55 & BETWEEN S38R TO S38L. REPLACED FLOOR PANEL 151VG IAW A319 SRM 53-02-00 & IRM 9701 REV G.SDR IPXA12B76024Floorboard · gougedMAIN CARGO DECK POS 4L OTBD PANEL I.25 FROM OTBD AND 22" FROM FWD EDGE LESS THAN 1" GOUGE. REPAIRED IAW SRM 53-00-50-2R-1.SDR IPXA12B76023Floorboard · puncturedMC DECK POS 4L HAS .5" HOLE. REPAIRED FLOORBOARD IAW SRM 53-00-50, 2R-1 PARA 4C.SDR USAA2012102300002Floor Panel · damagedOVERNIGHT VISIT - CENTER FLOORBOARD FLEXING AT STA 1869, S26L. REPLACED CENTER FLOOR PANEL AT STA 1869, S26L IAW A320 AMM 53-12-12-400.SDR ASAA2012102193207Floor Panel · corrodedFWD CARGO BAY, FLOOR PANEL 120DF HAS LIGHT CORROSION AROUND THE EDGES. FOUND CORROSION TO BE OUT OF LIMITS ON FLOOR PANEL IAW SRM 53-00-53. FABRICATED NEW FLOOR PANEL IAW DWG 453A1610-20.SDR ASAA2012102193169Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 120AF HAS CORROSION AT FWD EDGE. FOUND CORROSION ON PANEL TO BE OUT OF LIMITS WITH MORE THAN 3" IN DIAMETER IAW SRM 53-00-53. FABRICATED NEW PANEL IAW DWG 453 A 1610-14 REVE AND SRM 51-40-02.SDR ASOA2012103102411Floor Panel · crackedLEFT FWD EQUIPMENT BAY FLOOR IS CRACKED. COMPLIED WITH EC/TC REO 670-53-11-509 & GENERIC REO 670-53-11-509 REV--. FOUND TO BE SATISFACTORY.SDR FDEA201210203701Floorboard · crackedMAIN DECK CARGO AFT FLOORBOARD 251BH HAS TWO CRACKS AROUND CLEVIS ADAPTERS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ25-005.SDR FDEA201210203699Floor Panel · damagedMAIN DECK CARGO FLOOR PANEL 231EF HAS TWO CRUSHED AREAS, THE DAMAGE WAS FOUND ON REPAIR OF SEAT TRACK 4L, FR 20. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR IPXA12675963Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 4/5 LT AT LBL 84 HAS .5 INCH HOLE. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA12675962Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 4/5 LT SIDE AT LBL 82 HAS 1 INCH HOLE. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR FDEA201210193690Floor Panel · crackedFLOOR PANEL 232YG CENTER TOP SKIN CRACKED APPROX 8 INCHES FWD OF THE CLEVIS ADAPTER. AFT CLEVIS AREA CRACK APPROX 4". FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210193689Floor Panel · damagedFLOOR PANEL 231NG TOP SKIN PUNCTURE APPROX .5" X .2500" AND PANEL 231TG TOP SKIN PUNCTURE APPROX .5" X .5". REPAIRED FLOOR PANEL IAW SRM 53-10-20, PARA 9(A) PG 205 AND FABRICATED. REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210193688Floorboard · crackedAFT LEFT FLOORBOARD 251QH HAS AN 8 INCH CRACK AT CLS CUTOUT. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201210193687Floor Panel · crackedFLOOR PANEL 242UJ TOP SKIN HAS IMPACT DAMAGE AT 5 CLEVIS LOCATIONS AND TOP SKIN CRACKING AROUND THE CLEVIS POINTS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210183676Floorboard · crackedMAIN DECK CARGO FLOORBOARD 251BH HAS 2 CRACKS 4 & 6 INCHES AROUND CLEVIS ADAPTERS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005 REV J.SDR FDEA201210183675Floorboard · crackedMAIN DECK CARGO FLOORBOARD 242PH HAS A 4 INCH CRACK AT CLEVIS CUTOUT. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005 REV J.SDR FDEA201210183679Floorboard · crackedMAIN DECK CARGO AFT RT FLOORBOARD 252VF HAS TWO CRACKS 8 INCHES LONG AT CLEVIS CUTOUTS. FABRICATED, AND INSTALLED NEW FLOORBOARD IAW AMM 53-10-25-04-02 AND IAW DWG SRZ-005.SDR FDEA201210183678Floorboard · crackedMAIN DECK CARGO AFT RIGHT FLOORBOARD 252UH HAS ONE 3 INCH & ONE 6 INCH CRACK AT CLEVIS CUTOUTS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005 REV. J.SDR FDEA201210183677Floor Panel · damagedFLOOR PANEL 231AH HAS TWO AREAS OF CRUSHED CORE DAMAGE AT THE CLEVIS ADAPTERS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR IPXA12575907Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 231XQF IS BROKEN. FABRICATED NEW FLOORBOARD IAW B757-5320-9692-H.SDR FDEA201210173654Floor Panel · damagedFLOOR PANEL 242EK CRUSH AT 2 CLEVIS ADAPTER FABBED FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210173653Floor Panel · damagedFLOOR PANEL 242ZJ IMPACT DAMAGE AT 3 CLEVIS ADAPTER. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210173652Floor Panel · damagedMAIN DECK CARGO FLOOR PANEL BETWEEN FR 30 AND FR32 AND SEAT TRACKS 4L & 5L IMPACT DAMAGE APPROX 30 SQUARE INCHES. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210173651Floor Panel · damagedFLOOR PANEL 242RG HAS CRUSH DAMAGE AT CLEVIS AND METAL STRIP ON PANEL CHAFED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201210173633Floor Panel · damagedFLOOR PANEL 242QJ HAS CRUSH CORE DAMAGE AT ALL CLEVIS ADAPTER AREAS AND TOP SKIN CRACKED APPROX 90 PERCENT OF THE PANEL. PANEL FWD TEFLON MISSING. FABRICATED REPLACEMENT PANEL WITH TEFLON STRIPS IAW DWG SRZ-25-005, REV J.SDR FDEA201210173632Floor Panel · damagedFLOOR PANEL 242SF TOP SKIN HAS CRUSH DAMAGE AT THE CLEVIS AND TOP PLY CRACK APPROX 12". PANEL FWD TEFLON MISSING AND AFT TEFLON MISSING. FABRICATED REPLACEMENT PANEL WITH TEFLON STRIPS IAW DWG SRZ-25-005, REV J.SDR IPXA12175955Floor Panel · delaminatedINSPECTION TYPE:10YR, MAIN DECK CARGO FLOOR PANEL 241LJ DELAMINATED. REPAIRED IAW EO NR A300-5320-42721-B, PARA 6A.SDR DALA12010353135Floor Panel · damagedAFT CARGO FLOOR PANELS HAVE SEVERAL SMALL HOLES. REPAIRED IAW SRM 53-02-00. OK FOR SERVICE.SDR UALA2012101505867Floorboard · damagedIN REFERENCE TO SMC2, FLOORBOARD WAS FOUND TO BE SPONGY AND SUSPECT CRACKING-FLEXING. DOES NOT MEET CRITERIA OF MT 53-007 OR SRM 53-02-00 TO CONTINUE IN SERVICE. REMOVED AND REPLACED FLOOR PANEL 151DF FWD OF DOOR.SDR DALA12010363137Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151ZG DELAMINATED AND PUNCTURED. REPAIRED FLOOR PANEL IAW SRM 53-02-00.SDR IPXA12B75817Floor Panel · damagedMAIN DECK FLOOR PANEL HAS 1 INCH DIA HOLE TO THE TOP SURFACE PAN. REPAIRED REF SRM 53-00 50 2R-1, PAR4C.SDR IPXA12675819Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL AT POS NR 6L HAS 1" HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12175922Floorboard · puncturedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 231QJ HAS LOWER SKIN PUNCTURED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175921Floorboard · delaminatedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 221BG HAS LOWER SKIN DELAMINATED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175920Floorboard · puncturedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 232JF HAS LOWER SKIN PUNCTURED. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175919Floorboard · delaminatedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 232LF HAS LOWER SKIN PUNCTURED AND DELAMINATED. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.
Back to JASC 5321