JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024111452049Floor Panel · corrodedDOT L7-015: AFT CARGO COMPARTMENT FLOOR PANEL 140AF HAS CORROSION AT FASTENER HOLES ALONG PANEL EDGES<[01] RECEIVED REPLACEMENT MATERIAL PN 2024-T3-071 A TAG A263953 AND VERIFIED IT TO BE CORRECT REPLACEMENT MATERIAL IAW SRM 53-60-53-0I-1 FABRICATED PANEL 140ASDR SWAA2024111452050Floor Panel · corrodedDOT L7-016: AFT CARGO COMPARTMENT FLOOR PANEL 140BF HAS CORROSION AT FASTENER HOLES ALONG PANEL EDGES<[01] UPON FURTHER INVESTIGATION FOUND THERE TO BE 60 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF 3 INCHES PERMITTED FOUND TO BE OUT OF LIMITS IAW SRM 53-SDR SWAA2024111452052Floor Panel · corrodedDOT L7-018: AFT CARGO COMPARTMENT FLOOR PANEL 140CF HAS CORROSION AT FASTENER HOLES ALONG PANEL EDGES<[01] UPON FURTHER INVESTIGATION FOUND THAT CORROSION WAS 20 INCHES IN LENGTH WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-SDR SWAA2024111452053Floor Panel · corrodedDOT L7-019: AFT CARGO COMPARTMENT FLOOR PANEL 140DF HAS CORROSION AT FASTENER HOLES ALONG PANEL EDGES<[01] UPON FURTHER INVESTIGATION FOUND THAT CORROSION WAS 20 INCHES IN LENGTH WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-SDR FDEA202410221589Floor Panel · noneAIRCRAFT REPAIR ASSESSMENT : EXISTING DOUBLER REPAIR FOUND ON BULK CARGO COMPARTMENT FLOOR PANEL 162DF COMPLIED WITH ATTACHMENT B OF EO: E6-5100-7-5000 D7 PT1, TITLE: STRUCTURES - REPAIR CATALOG - A300/A310 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 SDR DALA2024102410366Baffle · cracked(LOG 0623705) FORWARD CARGO COMPARTMENT L/H FLOOR BAFFLE STA 500B-500C CRACKED. REMOVED AND REPLACED FORWARD CARGO COMPARTMENT L/H FLOOR BAFFLE STA 500B-500C I.A.W. B737-800 SRM 51-10-02-0G PAR 9, SRM 51-40-02; SRM 51-40-05-0G AND BOEING DWG# 143A7505.SDR DALA2024102310325Floor Panel · delaminatedSHIP 3133 DELAMINATED FLOOR PANEL 261PF AT ZONA 260 AT PASSENGER CABIN. CORRECTIVE ACTION: COMPLIED WITH ER/A 620988-14. (0622714)SDR FDEA202410221574Floor Panel · damagedFLOORBOARD 222MAF FIBERS DAMAGED DUE TO REMOVAL OF TAPE FABRICATED ZONE 220 FLOORBOARD 222MAF ON VTMAE TRAVELER #T24/1780933 IAW DWG SRZ- 25-005 REVISION R MAJOR REPAIRSDR FDEA202410221572Floor Panel · dentedMAIN CABIN FLOOR PANEL 242MRF DENTED DOT 01/014 FABRICATED ZONE 240 FLOOR PANEL 242MRF ON VTMAE TRAVELER #T24/1783045 IAW DWG SRZ- 25-005 REVISION R MAJOR REPAIR.SDR FDEA202410221571Floor Panel · damagedMID CABIN FLOOR PANEL 242MKF DAMAGED. FABRICATED ZONE 240 FLOOR PANEL 242MKF ON VTMAE TRAVELER #T24/1781135 IAW DWG SRZ- 25-005 REVISION R, MAJOR REPAIR.SDR SWAA2024111451373Floor Panel · corrodedDOT L7-003: FWD CARGO COMPARTMENT FLOOR PANEL 120DF HAS CORROSION ALONG EDGES OF PANEL<[01] UPON FURTHER INVESTIGATION; FOUND THAT CORROSION WAS 30 INCHES IN LENGTH WITH A MAX ALLOWABLE LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1; RECEIVSDR SWAA2024111451381Floor Panel · corrodedDOT L7-004: FWD CARGO COMPARTMENT FLOOR PANEL 120CF HAS CORROSION ALNG EDGES OF PANEL<[01] FOUND SEVERAL GOUGES AND MORE THAN 3 INCHES OF CORROSION ALONG THE LENGTH WITH THE MAX LENGTH OF 3 INCHES ALLOWED FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. RECEIVSDR IPXA2024102350799Floor Panel · brokenBROKEN - FOUND M/D FLOOR PNL BROKEN AT STA 764 TO STA 830 LBL-45, (P/N:145T5876-65) (REPAIR). SERO-9693-REQ-001.SDR IPXA2024102352696Floor Panel · brokenBROKEN - FOUND M/D FLOOR PNL BROKEN AT STA 977 TO STA 1043 RBL -45 (P/N: 145T5876-75) (REPAIR). UPS EO-91828-REQ1 REV.1.SDR FDEA202410211568Floor Panel · damagedFWD CABIN FLOOR PANEL 232MNF DAMAGED. FABRICATED ZONE 230 FLOOR PANEL 232MNF ON VT MAE TRAVELER T24/1781118 IAW DWG SRZ- 25-005 REVISION R. MAJOR REPAIRSDR FDEA202410211567Floor Panel · dentedFWD CABIN FLOOR PANEL 232MJF HAS SOME DENT DAMAGE. FABRICATED ZONE 230 FLOOR PANEL 232MJF ON VT MAE TRAVELER T24/1781111 IAW DWG SRZ-25- 005 REVISION R MAJOR REPAIRSDR FDEA202410211566Floor Panel · damagedFWD CARGO FLOOR PANEL 231MGF DAMAGED. FABRICATED ZONE 230 FLOOR PANEL 231MGF ON VT MAE TRAVELER T24/1781104 IAW DWG SRZ- 25-005 REVISION R. MAJOR REPAIRSDR FDEA202410211565Floor Panel · dentedFWD CABIN FLOOR PANEL 231MCF HAS DENT DAMAGE. FABRICATED ZONE 230 FLOOR PANEL 231MCF ON VT MAE TRAVELER T24/1781102 IAW DWG SRZ- 25-005 REVISON R. MAJOR REPAIRSDR AALA202411133338Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN SEAT 4L-5L FLOOR PANEL IS DELAMINATED. ACCOMPLISHED A PERMANENT REPAIR ON MAIN CABIN FLOOR PANEL PER SRM B787-A-53-00-50-01A-030A-A.SDR AALA202411138818Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN SEAT 22D TO 23D FLOOR PANEL IS DELAMINATED. ACCOMPLISHED PERMANENT REPAIR ON FLOOR PANEL PER SRM B787-A-53-00-50-01A-030A-A.SDR AALA202411132167Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN SEAT 6L TO SEAT 8L FLOOR PANEL IS DELAMINATED. ACCOMPLISHED PERMANENT REPAIR ON FLOOR PANEL PER SRM B787-A-53-00-50-01A-030A-A.SDR IPXA2024102342031Floor Panel · crackedFOUND FLOOR PANEL WITH CRACK DAMAGE IN MAIN DECK, PANEL NO: 251XFF, P/N: 146T5869-135. (REPAIR). I.A.W AMM 25-57-05-404-006, AMM 25-58-01-404-005, AMM 25-57-02-404-016 AND AMM 25-58-04-404-015 REV.143 INSTALLED MAIN DECK CARGO HANDLING AND CONDITION CHECK NORSDR ASAA2024101953532Floor Panel · brokenRIGHT O/B FLOOR PANEL JUST FWD OF R-2 DOOR HAS 5EA CORRODED INSERTS. GROUNDED - YES. REPAIRED RIGHT O/B FLOOR PANEL JUST FWD OF R-2 DOOR 5EA CORRODED INSERTS WITH A PERMANENT REPAIR IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024101953531Floor Panel · brokenCTR FLOOR PANEL BETWEEN R-2 AND L-2 DOOR HAS 1EA CORRODED INSERT. GROUNDED - YES. REPAIRED CTR FLOOR PANEL BETWEEN R-2 AND L-2 DOOR CORRODED INSERTS, 2EA,WITH A PERMANENT REPAIR IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024101953530Floor Panel · delaminatedLEFT O/B FLOOR PANEL JUST FWD OF L-2 DOOR HAS 5EA CORRODED INSERTS. GROUNDED - YES. REPAIRED LEFT O/B FLOOR PANEL JUST FWD OF L-2 DOOR 5EA CORRODED INSERTS AND AN AREA OF DELAMINATION WITH A PERMANENT REPAIR IAW B737-900ER SRM 53-00-50-1A-1,53-00-50-2R-0,53-00SDR ASAA2024101953528Floor Panel · delaminatedLEFT O/B FLOOR PANEL AT L-2 DOOR HAS TORN AND SEPERATED FIBERGLASS WITH MISSING INSERT. GROUNDED - YES. PERFORMED PERMANENT REPAIR ON LEFT O/B FLOOR PANEL AT L-2 DOOR #:147A5810-439 IAW ASA B737-900 ER SRM 53-00-50-2R-0, ASA B737-900 ER SRM 53-00-50-2R-2 & ASASDR ASAA2024101953527Floor Panel · corrodedLEFT O/B FLOOR PANEL AT L-2 DOOR HAS 6EA CORRODED INSERTS. GROUNDED - YES. REMOVED 28EA CORRODED INSERTS ON LEFT O/B FLOOR PANEL AT L-2 DOOR #:147A5810-439 AND REPLACED WITH 28EA NEW INSERTS IAW ASA B737-900 ER SRM 53-00-50-2R-0. NO FURTHER ACTION REQUIRED.SDR ASAA2024101953526Floor Panel · corrodedRIGHT O/B FLOOR PANEL AT R-2 DOOR HAS 7EA CORRODED INSERTS. GROUNDED - YES. REMOVED 16EA CORRODED INSERTS ON RIGHT O/B PANEL AT R-2 DOOR#: 147A5810-440 AND REPLACED WITH 16EA NEW INSERTS IAW ASA B737-900ER SRM 53-00-50-2R-0. NO FURTHER ACTION REQUIRED.SDR ASAA2024101953525Floor Panel · delaminatedRIGHT O/B FLOOR PANEL AT R-2 DOOR HAS TORN FIBERGLASS. GROUNDED - YES. PERFORMED PERMANENT REPAIR ON RIGHT O/B FLOOR PANEL AT R-2 DOOR#: 147A5810- 440 IAW ASA B737-900ER SRM 53-00-50-2R-7 & ASA B737-900ER SRM 53-00-50-2R-0. NO FURTHER ACTION REQUIREDSDR FDEA202410191550Floorboard · damagedZONE 230 MAIN DECK FLOORBOARD 232MGF HAS DENT DAMAGE. FABRICATED ZONE 230 FLOORBOARD 232MGF ON VTMAE TRAVELER # T24/1781109 IAW DWG SRZ 25-005 REV R. MAJOR REPAIR.SDR FDEA202410191549Floorboard · damagedZONE 230 MAIN DECK FLOORBOARD 231MAF DAMAGED. FABRICATED ZONE 230 FLOORBOARD 231MAF ON VTMAE TRAVELER # T24/1781100 IAW DWG SRZ 25-005 REV R. MAJOR REPAIR.SDR FDEA202410191548Floorboard · dentedZONE 230 MAIN DECK FLOORBOARD 231MBF HAS DENT DAMAGED AREAS. FABRICATED ZONE 230 FLOORBOARD 231MBF ON VTMAE TRAVELER # T24/1781101 IAW DWG SRZ 25-005 REV R. MAJOR REPAIR.SDR FDEA202410191547Floorboard · damagedZONE 230 MAIN DECK FLOORBOARD 232MTF DAMAGED. FABRICATED ZONE 230 FLOORBOARD 232MTF ON VTMAE TRAVELER # T24/1781130 IAW DWG SRZ 25-005 REV R. MAJOR REPAIR.SDR FDEA202410191546Floorboard · damagedZONE 240 MAIN DECK FLOOR PANEL 241MKF HAS DENT DAMAGE. FABRICATED ZONE 240 FLOORBOARD 241MKF ON VTMAE TRAVELER # T24/1781134 IAW DWG SRZ 25-005 REV R. MAJOR REPAIR.SDR FDEA202410191545Floorboard · damagedZONE 230 MAIN DECK FLOOR PANEL 231MF DAMAGED. FABRICATED ZONE 230 FLOORBOARD 231MFF ON VT MAE TRAVELER # T24/1781103 IAW DWG SRZ- 25-005 REV R. MAJORE REPAIR.SDR SWAA2024112050337Floor Panel · pulledCABIN FLOOR PANEL 231XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] CABIN FLOOR PANEL 231XF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024112050339Floor Panel · pulledCABIN FLOOR PANEL 241AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] CABIN FLOOR PANEL 241AF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATE FLOOR PANEL PER SRM 53-00-50-2R-0.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024112050340Floor Panel · pulledCABIN FLOOR PANEL 241DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] CABIN FLOOR PANEL 241DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024112050343Floor Panel · pulledCABIN FLOOR PANEL 242CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] CABIN FLOOR PANEL 242CF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024112050344Floor Panel · pulledCABIN FLOOR PANEL 242DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED CABIN FLOOR PANEL 242DF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-42A ITEM 135.;[02] VERIFIED CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024112050346Floor Panel · pulledCABIN FLOOR PANEL 242AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] CABIN FLOOR PANEL 242AF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR FDEA202410181544Floor Panel · puncturedWHILE PERFORMING OTHER MAINTENANCE FOUND MAIN DECK CARGO COMPARTMENT FLOOR PANEL PUNCTURED AT APPROX STA 1130 R/H SIDE 48" INBD FROM SIDEWALL MWT. REPAIRED MAIN CARGO DECK FLOORBOARD AT STA. 1130 RBL. 77.5 (MPN: 141T5869-154 / PNL# 252CFF) IN REF. TO FEDEXSDR SWAA2024112149568Floor Panel · crackedCABIN FLOOR PANEL 221GF FWD O/B CORNER TANG IS CRACKED.<[01] CABIN FLOOR PANEL 221GF FWD O/B CORNER TANG WITH CRACK WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION ITEM 1SDR SWAA2024112150081Floor Panel · delaminatedCABIN FLOOR PANEL 232AF TOP SURFACE DELAMINATED.<[01] CABIN FLOOR PANEL 232AF WITH TOP SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR FDEA202410171539Floor Panel · puncturedMAIN DECK CARGO COMP, FLOOR PANEL 241AFF (BTW STA 700 AND STA 800 AND BBL 0) WITH PUNCTURE MAIN DECK CARGO FLOOR PANEL 241AFF (BTW STA 700 AND STA 800 AND BBL 0) WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIGURE 201 SHEET 2 REV 90 AUG 15/2024SDR FDEA202410171538Floor Panel · dentedFLOOR PANEL 242UFF WITH DENT. MAIN DECK CARGO FLOOR PANEL 242UFF WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIGURE 201 SHEET 2 REV 90 AUG 15/2024.SDR FDEA202410171537Floor Panel · puncturedFLOOR PANEL 241LFF WITH HOLE MDC FLOOR PANEL 241LFF WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4.B FIG 201 SHEET 2 REV 90 AUG 15/2024SDR FDEA202410171536Floor Panel · puncturedMAIN DECK CARGO COMP, FLOOR PANEL 241AGF WITH PUNCTURE. MAIN DECK CARGO FLOOR PANEL 241AGF WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR 4B FIGURE 201 SHEET 2 REV 90 AUG 15/2024.SDR FDEA202410171535Floorboard · damagedMAIN DECK CARGO FLOORBOARD FLOOR PANEL PUNCTURED AT APPROX STA. 360 RH OF CENTER MARKED. REPAIRED MAIN CARGO DECK FLOORBOARD AT STA. 360 RBL. 33 (PNL# 222BFF) IN REF. TO FEDEX DRW# SRZ-25-005 AND 767 SRM 53-00-50-2R PARA. 5.A - 5.O FIG.201 SHEET 2. THIS ISDR SWAA2024112549551Floor Panel · delaminatedCABIN FLOOR PANEL 242VF CORRODED INSERTS AND TOP SURFACE DELAMINATION.<[01] CABIN FLOOR PANEL 242VF WITH TOP SURFACE DELAMINATION WAS REPAIRED AND CORRODED INSERTS WERE REPLACED IAW SRM 53-00-50-2R-1AND DWG 147A5810 ID:0350; DWG D1040M003-309.;[02] JOB COMPLET
Back to JASC 5321