What was found
RIGHT O/B FLOOR PANEL JUST FWD OF R-2 DOOR HAS 5EA CORRODED INSERTS. GROUNDED - YES. REPAIRED RIGHT O/B FLOOR PANEL JUST FWD OF R-2 DOOR 5EA CORRODED INSERTS WITH A PERMANENT REPAIR IAW B737-900ER SRM 53-00-50-2R-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT O/B FLOOR PANEL JUST FWD OF R-2 DOOR HAS 5EA CORRODED INSERTS. GROUNDED - YES. REPAIRED RIGHT O/B FLOOR PANEL JUST FWD OF R-2 DOOR 5EA CORRODED INSERTS WITH A PERMANENT REPAIR IAW B737-900ER SRM 53-00-50-2R-0.