What was found
LEFT O/B FLOOR PANEL AT L-2 DOOR HAS TORN AND SEPERATED FIBERGLASS WITH MISSING INSERT. GROUNDED - YES. PERFORMED PERMANENT REPAIR ON LEFT O/B FLOOR PANEL AT L-2 DOOR #:147A5810-439 IAW ASA B737-900 ER SRM 53-00-50-2R-0, ASA B737-900 ER SRM 53-00-50-2R-2 & ASA B737-900ER SRM 53-00-50-2R-7. NO FURTHER ACTION REQUIRED.