JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA11164319Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231XG HAS A CRACK. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR231XG IAW EO A300-5320-38221-B, PARA.6ASDR IPXA11164317Floorboard · delaminatedINSPECTION TYPE:10YR, FLOORBOARD PANEL NR252FJ AT MAIN DECK IS DELAMINATED. ACCOMPLISHED REPAIR ON MAIN CARGO FLOORBOARD NR 252FJ IAW EO A300-5320-38221-B PARA 6A.SDR USAA2011011990274Floor Panel · delaminatedCWF - S2 - MAJOR REPAIR - NR 6309482 - DELAMINATION ON FLOOR PANEL 232EG BETWEEN FR26.4 TO FR31 & BETWEEN -Y1959 TO -Y2462. REPAIRED FLOOR PANEL 232EG BETWEEN FR26.4 TO FR31 & BETWEEN -Y1959 TO -Y2462 IAW A330 SRM 53-02-00.SDR USAA2011011990273Floor Panel · delaminatedCWF - S2 - MAJOR REPAIR - NR 6317427 - DELAMINATION ON FLOOR PANEL 221EF BETWEEN FR14 TO FR16 & BETWEEN Y953 TO -Y953. REPAIRED FLOOR PANEL 221EF BETWEEN FR14 TO FR16 & BETWEEN Y953 TO -Y953 IAW A330 SRM 53-02-00.SDR IPXA1164285Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231KJ IS CRACKED AND DELAMINATED. FABRICATED MAIN CABIN FLOORBOARD NR 231KJ IAW EO A300-5320-16407-E, APPENDIX B.SDR DALA1102679864Floor Panel · damagedMAIN PASSENGER CABIN FLOOR PANEL NR46 TOP SKIN HAS HOLE. REPAIRED MAIN PASSENGER CABIN FLOOR PANEL NR46 TOP SKIN IAW SRM 51-70-4, FIG 1.E.CASTELLO AP 3107610. REQUIRED INSP COMPLETED.SDR DALA1102649855Floor Panel · damagedMAIN PASSENGER CABIN SEVERAL WASHERS PULLING THROUGH SKIN OF FLOOR PANEL NR84. FABRICATED FLOOR PANEL WEB AND HAT CHANNELS FROM IAW DWG 9957919. ASSEMBLED PANEL WEB AND HAT CHANNELS IAW SRM 51-30-2 AND ERA 488336-14. REQUIRED INSPECTION COMPLETED.SDR DALA1102639855Floor Panel · corrodedMAIN PASSENGER CABIN CORROSION SEVERAL PLACES ON FLOOR PANEL NR 96 STA 1032. REMOVED CORROSION IAW SRM 51-10-3. ORIG THICKNESS WAS .025 AFTER BLEND MATERIAL IS .018. OUT OF LIMITS IAW SRM 53-01. FABRICATED NEW PANEL WEB AND HAT CHANNELS IAW DWG 9919601. SDR DALA1102599855Floor Panel · crackedMAIN PASSENGER CABIN FLOOR PANEL NR59 PANEL SKIN CRACKED. PANEL FOUND TO BE UNSERVICABLE NUMEROUS CRACKS AND 1 AREA WORN BEYOND LIMITS. FABRICATED NEW PANEL HAT CHANNELS 5 EA. ASSEMBLED PANEL IAW ERA-488332-14 MEL A3494901 09JAN 11. REQUIRED INSP COMPLETED.SDR IPXA11164405Floor Panel · crackedINSPECTION TYPE:10YR, FLOOR PANEL 251DN CRACKED. REPAIRED FLOOR PANEL 251DN IAW EO A300-5320-38221-B, PARA 6 (1).SDR IPXA11164375Floor Panel · brokenINSPECTION TYPE:10YR, FLOOR PANEL 252DN IS BROKEN/DELAMINATED. FABRICATED NEW FLOOR PANEL 252DN IAW EO A300-5320-16407-E.SDR IPXA11164362Floor Panel · crackedINSPECTION TYPE:10YR, MAIN CARGO FLOOR PANEL 261LE IS CRACKED. REPAIRED MAIN CARGO FLOOR PANEL 261LE IAW EO A300-5320-38221-B PARA 6 (1).SDR IPXA11164346Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR261GH UNDER SURFACE IS CRACKED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR261GH IAW EO A300-5320-38221-B, PARA, 6A.SDR IPXA11164322Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD PANEL NR251ZJ IS DELAMINATED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR251ZJ IAW EO A300-5320-38221-B PARA 6A.SDR IPXA11164318Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR262SF UNDER SURFACE IS CRACKED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR262SF IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA1564313Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT BS 560-620, RBL 45-65 IS DAMAGED. (DAMAGE BEYOND SRM LIMITS). FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR USAA2011011990275Floor Panel · delaminatedCWF - S2 - MAJOR REPAIR - DELAMINATION ON FLOOR PANEL 251QG BETWEEN FR51 TO FR53.2 & BETWEEN Y953 TO Y1456. REPAIRED FLOOR PANEL 251QG BETWEEN FR51 TO FR53.2 & BETWEEN Y953 TO Y1456 IAW A330 SRM 53-02-00.SDR IPXA11564143Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT BS 560-620, LBL 25-45 DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11564142Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT BS 560-620 RBL 0-25 IS DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR DALA1102489855Floorboard · chafedCABIN FLOORBOARD, 90C FASTENER HOLES HAVE CHAFING MARKS, BOTTOM. BLENDED CHAFED AREA ON FLOOR IAW SRM 51-10-3. ORIGINAL THICKNESS .025" AFTER BLENDOUT .012" OUT OF LIMITS IAW SRM 53-01, FIG 1. FABRICATED PANEL WEB AND HAT CHANNELS IAW DWG CORRECTED BY FILSDR IPXA11164406Floor Panel · crackedINSPECTION TYPE:10YR, FWD CARGO COMPT FLOOR PANEL 132QG CRACKED/PUNCTURED. REPAIRED FLOOR PANEL 132QG IAW EO A300-5320-38221-B, PARA 6 (1).SDR IPXA11164376Floor Panel · crackedINSPECTION TYPE:10YR, FWD CARGO COMPT FLOOR PANEL 132PG IS CRACKED/PUNCTURED. FABRICATED NEW FLOOR PANEL 132PG IAW EO A300-5320-16407-E.SDR IPXA11164373Floor Panel · crackedINSPECTION TYPE:10YR, FWD CARGO COMPT FLOOR PANEL 131BH IS CRACKED. REPAIRED FWD CARGO COMPT FLOOR PANEL 131BH IAW EO A300-5320-38221-B, PARA 6 (1).SDR IPXA11164360Floor Panel · puncturedINSPECTION TYPE:10YR, FWD CARGO COMPT FLOOR PANEL 131RG IS PUNCTURED. REPAIRED FWD CARGO COMPT FLOOR 131RG IAW EO A300-5320-38221-B, PARA 6 (1).SDR IPXA11164357Floor Panel · brokenINSPECTION TYPE:10YR, FWD CARGO COMPT FLOOR PANEL 132SG CORNER BROKEN. REPAIRED FWD CARGO COMPT FLOOR PANEL 132SG IAW EO A300-532038221-B, PARA 6 (1).SDR IPXA11164329Floorboard · brokenINSPECTION TYPE:10YR, FWD CARGO COMPARTMENT FLOORBOARD NR132RG CORNER IS BROKEN/PUNCTURED. FABRICATED FWD CARGO FLOORBOARD NR132RG IAW EO A300-5320-16407-E, APPENDIX C.SDR ASOA201100060Pressure Panel · corrodedRT SIDE PRESSURE FLOOR CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 TO 559. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS OF BLENDED AREAS IAW MAC NDT INSP PROCEDURE UT-3. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS OF SRM 53-41-45 FIGURE 101. DASDR ASOA201100059Pressure Panel · corrodedLT SIDE PRESSURE FLOOR CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 AND 559. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS OF BLENDED AREA IAW MAC NDT INSP PROCEDURE UT-3. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS OF SRM 53-41-45 FIG 101. DASDR IPXA11664084Floorboard · damagedFLOORBOARD DAMAGED, POS 6L. FABRICATED NEW FLOOR.SDR IPXA11664076Floor Panel · damagedFLOOR PANEL DAMAGED, POS 13 LT, FABRICATED NEW PANEL.SDR IPXA11564078Floor Panel · damagedINSPECTION TYPE:C1, ACB FLOOR STA 1310 TO 1470 HAS FRETTING DAMAGE ON UPPER SURFACE. FRETTING FOUND TO BE CORROSION. FABRICATED NEW FLOOR PANEL IAW SRM 51-10-02-0G, SRM 53-60-53-1, SRM 53-00-53-1A1, SRM 53-60-53-0I1, SRM 51-40-05-0G, SRM 51-40-08-0G.SDR IPXA11564077Floor Panel · damagedINSPECTION TYPE:C1, INTERIOR FLOORBOARD HAS INSERTS DAMAGED STA 324, LBL 25. FABRICATED NEW FLOORBOARD PANEL IAW EO NR B757-5320-9692-G.SDR IPXA1164284Floorboard · crackedINSPECTION TYPE:10YR, AFT CARGO FLOORBOARD NR 151UF LOWER SURFACE IS CRACKED. FABRICATED AFT CARGO FLOORBOARD NR151UF IAW EO A300-5320-16407-E, APPENDIX C.SDR IPXA1164229Floorboard · delaminatedINSPECTION TYPE:10YR, AFT CARGO FLOORBOARD NR 151VF IS DELAMINATED. FABRICATED AFT CARGO FLOORBOARD NR 151VF IAW EO A300-5320-16407-E.SDR USAA2011011590228Floor Panel · delaminatedCLT - S2 - MAJOR REPAIR - DELAMINATION ON FLOOR PANEL 242DF BETWEEN FR31 TO FR33 & BETWEEN -Y1456 TO -Y1959. REPAIRED FLOOR PANEL 242DF BETWEEN FR31 TO FR33 & BETWEEN -Y1456 TO -Y1959 IAW A330 SRM 53-02-00.SDR USAA2011011590227Floor Panel · delaminatedCLT - S2 - MAJOR REPAIR - DELAMINATION ON FLOOR PANEL 261CH BETWEEN FR55 TO FR57.1 & BETWEEN Y953 TO Y1959. REPAIRED FLOOR PANEL 261CH BETWEEN FR55 TO FR57.1 & BETWEEN Y953 TO Y1959 IAW A330 SRM 53-02-00.SDR USAA2011011590226Floor Panel · delaminatedCLT - S2 - MAJOR REPAIR - DELAMINATION ON FLOOR PANEL 71PF BETWEEN FR78 TO FR80 & BETWEEN Y450 TO -Y450. REPAIRED FLOOR PANEL 271PF BETWEEN FR78 TO FR80 & BETWEEN Y450 TO -Y450 IAW A330 SRM 53-02-00.SDR DALA1101979864Floor Panel · corrodedMAIN PASSENGER CABIN STA 218-310 BL 0 FLOOR PANEL SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 53-01 FIG 1. ORIGINAL THICKNESS .060 IAW SRM 53-13-01, OUT OF LIMITS. FABRICATED FLOOR SUPPORT IAW SRM 51-10-2. FABRICATED & INSTALLED CLIPS IAW SRM 53-05, FSDR IPXA1164230Floorboard · dentedINSPECTION TYPE:10YR, DENTS ON BULK CARGO FLOORBOARD NR 161KF. FABRICATED BULK CARGO FLOORBOARD NR 161KF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA1164209Floor Panel · dentedINSPECTION TYPE:10YR, BULK CARGO FLOOR PANEL 162LF HAS DENTS. FABRICATED NEW BULK CARGO FLOOR PANEL 162LF IAW EO A300-5320-16407-E, APPENDIX A/D.SDR IPXA1164208Floor Panel · dentedINSPECTION TYPE:10YR, BULK CARGO FLOOR PANEL 161GF HAS DENTS. FABRICATED NEW BULK CARGO FLOOR PANEL161GF IAW EO A300-5320-16407-E, APPENDIX A/D.SDR IPXA11164171Floorboard · dentedINSPECTION TYPE:10YR, DENTS ON BULK CARGO FLOORBOARD NR161MF. FABRICATED BULK CARGO FLOORBOARD NR161MF EO A300-5320-16407-E, APPENDIX D.SDR IPXA11164170Floorboard · dentedINSPECTION TYPE:10YR, DENTS ON BULK CARGO FLOORBOARD PANEL NR 162MF, FABRICATED BULK CARGO FLOORBOARD NR162MF IAW EO A300-5320-16407-E, APPENDIX D.SDR USAA2011011990271Floor Panel · debondedCWF - C1 - MAJOR REPAIR - NR 6315230 - AREA OF DISBONDING ON FLOOR PANEL 232PF BETWEEN FR22 TO FR25 & BETWEEN -Y1959 TO -Y2462. REPAIRED FLOOR PANEL 232PF BETWEEN FR22 TO FR25 & BETWEEN -Y1959 TO -Y2462 IAW A330 SRM 53-02-00.SDR IPXA1564239Floor Panel · damagedINSPECTION TYPE:C1, ACB FLOOR STA 1510-1640 HAS FRETTING DAMAGE ON UPPER SURFACE. REMOVED CORROSION ON FLOOR PANEL. CORROSION FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 51-10-02-0G, SRM 53-60-53, SRM 53-00-53, SRM 51-40-05-0G, SRM SDR IPXA11564105Floor Panel · damagedINSPECTION TYPE:C1, ACB FLOOR STA 1510-1640 HAS FRETTING DAMAGE ON UPPER SURFACE. REMOVED CORROSION ON FLOOR PANEL. CORROSION FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 51-10-02-0G, SRM 53-60-53, SRM 53-00-53, SRM 51-40-05-0G, 51-4SDR IPXA11564061Floor Panel · damagedINSPECTION TYPE:C1, AFTER REMOVING ANTI-SKID FOUND FLOOR PANEL BS 440 TO 480 LBL25 TO LBL45 TO HAVE CRUSHED HONEY COMB CORE ON FWD END IN 2 AREAS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G AND SRM 53-00-50-1A-1, FIG 101.SDR F3LA2011010600580Floor Panel · puncturedC-CHECK: NON ROUTINE N0665; AFT CARGO COMPARTMENT FLOOR PANEL 151AE HAS 3 EACH PUNCTURES. REPAIRED 3 EACH PUNCTURES WITH WET LAYUP IAW SRM 53-02-00, PARA 8B.SDR F3LA2011010600579Floor Panel · puncturedC-CHECK: NON ROUTINE N0660; AFT CARGO COMPARTMENT FLOOR PANEL 151DE HAS 2 EA PUNCTURES. REPAIRED 2 EACH PUNCTURES IAW SRM 53-02-00, PARA 8B.SDR F3LA2011010600578Floor Panel · puncturedC-CHECK: NON ROUTINE N0659; AFT CARGO COMPARTMENT FLOOR PANEL 152TG HAS 1 INCH PUNCTURE. REPAIRED PUNCTURE WITH WET LAYUP REPAIR IAW SRM 53-02-00, PARA 8B.
Back to JASC 5321