JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10160685Floorboard · puncturedINSPECTION TYPE:10YR, PUNCTURES ON BOTTOM SIDE OF AFT CARO COMPARMENT FLOORBOARD NR 151SF. FABRICATED AFT CARGO FLOORBOARD NR 151SF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160683Floorboard · gougedINSPECTION TYPE:10YR, GOUGES AT BOTTOM SIDE OF AFT CARGO FLOORBOARD PANEL NR 151LG. FABRICATED AFT CARGO FLOORBOARD NR 151LG IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA0160641Floorboard · delaminatedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 261DM IS DELAMINATED AND CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 261DM IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA0160640Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231LJ HAS A CRACK FABRICATED MAIN CABIN FLOORBOARD NR 231LJ IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA0160638Floorboard · puncturedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 242YK HAS A PUNCTURE PERMANENTLY REPAIRED FLOORBOARD NR 242YK IAW EO A300-5320-38221-A.SDR IPXA0160613Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD PNL NR 252VJ HAS 2 CRACKS FABRICATED MAIN CABIN FLOORBOARD NR 252VJ IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA0160612Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 252LG HAS A CRACK. FABRICATED MAIN CARGO FLOORBOARD NR252LG PER UPS EO A300-5320-16407-D APPENDIX B.SDR IPXA0160611Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 232FF HAS A CRACK. FABRICATED MAIN CABIN FLOORBOARD NR 232FF IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10660607Floor Panel · puncturedINSPECTION TYPE:C, MCD STA412 TO 544 LBL 77 TO LBL 88 FLOOR PANEL FOUND 4 PUNCTURE HOLES TOGETHER WITH 6 DENT. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.SDR IPXA10660599Floor Panel · puncturedINSPECTION TYPE:C, MCD STA1425 TO 1522, RBL55 TO RBL77, FLOOR PANEL FND 2 PUNCTURE HOLES AND 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REPLACED IAW AMM 53-01-01.SDR IPXA10660598Floor Panel · puncturedINSPECTION TYPE:C, STA412 TO 544 LBL55 TO 77 MCD FLOOR PANEL FND PUNCTURE HOLES AND 5 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B77-5320-9693-G AND REPLACED IAW AMM 53-01-01.SDR IPXA10660577Floor Panel · damagedINSPECTION TYPE:C, MCD STA540 TO 654+22 LBL11 TO RBL11 FLOOR PANEL FND 6 DAMAGED AND 4 DENT MARKS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.SDR IPXA10660576Floor Panel · puncturedINSPECTION TYPE:C, MCD STA 972 TO 1112, LBL 11 TO RBL 11, FLOOR PANEL FOUND 3 PUNCTURE HOLES AND TOGETHER WITH 6 DENT MARKS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.SDR IPXA10660575Floor Panel · damagedINSPECTION TYPE:C, STA1207 TO 1351 RBL11 TO LBL11 FLOOR PANEL FND 3 DAMAGE AND 4 DENT MARKS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.SDR IPXA10660574Floor Panel · puncturedINSPECTION TYPE:C, MCD STA 1197+22 TO 1207 LBL11 TO RBL11 FLOOR PANEL FND 5 PUNCTURE HOLES AND 5 DENTS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REPLACED IAW AMM 53-01-01.SDR IPXA10660573Floor Panel · damagedINSPECTION TYPE:C, MCD STA833 TO 930 RBL11 TO LBL11 FLOOR PANEL FND 6 DAMAGE AND TOGETHER WITH 5 DENT MARKS. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REPLACED IAW AMM 53-01-01.SDR IPXA10160542Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 241LJ IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 241LJ IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160541Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOOR PANEL NR 251JM IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 251JM IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160540Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD PANEL NR 231NJ HAS A CRACK. FABRICATED MAIN CABIN FLOORBOARD NR 231NJ IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160538Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231RG IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 231RG IAW UPS EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160451Floorboard · crackedINSPECTION TYPE:10YR, BOTTOM CRACKED ON FWD CARGO FLOORBOARD NR 132AH FABRICATED FWD CARGO FLOORBOARD NR 132AH IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160450Floorboard · crackedINSPECTION TYPE:10YR, EDGE DAMAGE AND BOTTOM CRACKED ON FWD CARGO FLOORBOARD NR 132PG. FABRICATED FWD CARGO FLOORBOARD NR 132PG IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160449Floorboard · damagedINSPECTION TYPE:10YR EDGE DAMAGE ON FWD CARGO FLOORBOARD NR 132DE FABRICATED FWD CARGO FLOORBOARD NR 132DE IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160448Floorboard · damagedINSPECTION TYPE:10YR, EDGE DAMAGE AT BOTTOM SIDE OF FWD CARGO FLOORBOARD NR 132MG. FABRICATED FWD CARGO FLOORBOARD NR 132MG IAW EO A300-5320-16407-D APPENDIX C.SDR IPXA10160447Floorboard · damagedINSPECTION TYPE:10YR, EDGE DAMAGE AT BOTTOM SIDE OF FWD CARGO FLOORBOARD 131FE, FABRICATED FLOORBOARD PANEL NR 131FE IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160864Floorboard · crackedINSPECTION TYPE:10YR AFT CARGO FLOORBOARD 152MG IS CRACKED. FABRICATED NEW AFT CARGO FLOORBOARD 152MG IAW EO A300-5320-16407-D APPENDIX A/C.SDR IPXA10160797Floorboard · damagedINSPECTION TYPE:10YR, EDGE DAMAGE ON FLOORBOARD NR 151NG IN AFT CARGO COMPARTMENT. FABRICATED FLOORBOARD AFT CARGO COMPARTMENT FLOORBOARD NR 151NGIAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160695Floorboard · damagedINSPECTION TYPE:10YR, EDGE DAMAGE ON FLOORBOARD NR 152TF IN AFT CARGO COMPT. FABRICATED AFT CARGO FLOORBOARD NR 152TF EO A300-5320-16407-D, APPENDIX C,SDR IPXA10160692Floorboard · puncturedINSPECTION TYPE:10YR, BOTTOM SIDE PUNCTURED ON FLOORBOARD NR 152SF IN AFT CARGO. FABRICATED AFT CARGO FLOORBOARD NR 152SF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160688Floorboard · damagedINSPECTION TYPE:10YR, EDGE DAMAGE ON FLOORBOARD NR 152UF IN AFT CARGO FABRICATED AFT CARGO FLOORBOARD NR 152UF IAW EO A300-5320-16407-D, APPENDIX. CSDR IPXA10160687Floorboard · gougedINSPECTION TYPE:10YR, PRE EXISTING BOTTOM SIDE GOUGES ON FLOORBOARD NR152QF IN AFT CARGO. FABRICATED AFT CARGO FLOORBOARD NR152QF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160686Floorboard · puncturedINSPECTION TYPE:10YR, BOTTOM SIDE IS PUNCTURED ON FLOORBOARD NR152VF IN AFT CARGO. FABRICATED AFT CARGO FLOORBOARD NR 152VF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160446Floorboard · puncturedINSPECTION TYPE:10YR BOTTOM SIDE PUNCTURE ON AFT CARGO FLOORBOARD NR 152LG. FABRICATED AFT CARGO FLOORBOARD NR 152LG IAW EO A300 5320-16407-D, APPENDIX C.SDR IPXA10160445Floor Panel · damagedINSPECTION TYPE:10YR EDGE DAMAGE F/B NR 151UF AFT CARGO. FABRICATED AFT CARGO FLOOR PANEL NR 151UF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10B60317Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL AT POS 8/9 RT OTBD PN 144U5882-4 HAS A SMALL HOLE 1.75L" X .250W .031 DEPTH LOCATED 10.5" FROM FWD EDGE AND 10" FROM INBD EDGE OF PANEL. REPAIRED PANEL IAW SRM 53-00-50. THIS IS A MAJOR REPAIR AND CONSIDERED PERM.SDR UIEA2010060600028Floor Panel · damagedDURING CARGO LOADING AT DOV; MX FOUND DAMAGE TO THE MAIN DECK FLOORBOARD AT BS 1080, RBL 45. THE DAMAGE TO THE MD FLOORBOARD PANEL AT BS1080, RBL45 AIS S FOLLOWS: THE DAMAGE IS ABOUT 7 INCHES LONG AND ABOUT .5 INCH WIDE, AND .2500 INCH DEEP. (DISPOSITION WAS MSDR UIEA2010060600026Floorboard · damagedDURING LOADING OUT PALLET CAUSED DAMAGE TO ROLLER CASTER TRAYS AND FLOORBOARD ON MAIN DECK LT SIDE & NBSP; STA 1600 & NBSP; & AMP; 1700 BETWEEN 18L AND 16L & NBSP; (IAW DDPG 25-53-01 CAT D ITEM TRANSFERRED TO MDDR 17366. ITEM EXPIRES 5 SEP 10. DAMAGED CASTER TSDR AALA20100616TUL15Doubler · corrodedCORROSION AT NUMEROUS PLACES ON EXISTING DOUBLER ON TOP OF FLOOR DECK PLATE STATION 1712 TO STATION 1720 RIGHT BUTTLINE 20 TO RIGHT BUTTLINE 40. REMOVED AND REPLACED DOUBLER PER SRM 53-60-51.SDR AALA20100616TUL14Doubler · corrodedCORROSION ON AFT GALLEY FLOOR DECK PLATE SURROUNDING EXISTING DOUBLER FROM STA.1711 TO STA. 1713 RIGHT BUTTLINE 19 TO RIGHT BUTTLINE 22. REMOVED AND REPLACED DOUBLER PER SRM 53-60-51.SDR AALA20100616TUL12Plate · corrodedCORROSION ON TOP OF AFT GALLEY FLOOR PLATE AT STA 1680, LEFT BUTTLINE 38 TO LEFT BUTTLINE 42. REMOVED AND REPLACED DOUBLER AT STA 1681 PER SRM 53-60-51.SDR AALA20100616TUL10Plate · corrodedCORROSION ON TOP OF AFT GALLEY FLOOR PLATE AT STA 1680, LEFT BUTTLINE 30 TO LEFT BUTTLINE 33. REMOVED AND REPLACED DOUBLER AT STA 1680 LEFT BUTTLINE 30 TO33, PER SRM 53-60-51.SDR AALA20100616TUL07Plate · corrodedCORROSION ON TOP OF AFT GALLEY FLOORBEAM DECK PLATE STA 1681, RIGHT BUTTLINE 23 TO 24. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 53-60-51.SDR AALA20100616TUL06Doubler · corrodedCORROSION IN NUMEROUS PLACES ON AFT GALLEY DECK PLATE EXISTING DOUBLER AT STA 1711 TO 1720, LEFT BUTTLINE 16 TO RIGHT BUTTLINE 11. REMOVED AND REPLACED EXISTING DOUBLER PER SRM 53-60-51.SDR AALA20100616TUL05Doubler · corrodedCORROSION IN NUMEROUS PLACES ON AFT GALLEY FLOOR DECK PLATE EXISTING DOUBLER AT STA 1711 TO STA 1720, LEFT BUTTLINE 38 TO 55. REMOVED AND REPLACED EXISTING DOUBLER PER SRM 53-60-51.SDR IPXA10B60300Floor Panel · damagedMCD FLOOR PANEL DAMAGED 1620, REPAIRED EO B747-5320-36924-C.SDR IPXA10B60299Floor Panel · damagedMCD FLOOR PANEL STA 1620 DAMAGED. REPAIRED IAW OE B747-5320-35924-C.SDR IPXA10560311Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS 480 TO BS 560, BL 0 TO RBL 25. FLOOR PANEL WAS REPALCED IAW EO B757-5320-9692-G.SDR IPXA10560291Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS 720 TO BS 820, BL 0 TO RBL 25. PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR IPXA10560290Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS480 TO BS560, BL0 TO RBL25. FLOOR PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR CA100622017Floor Panel · corrodedDURING A 100 HR/ANNUAL INSP, BAGGAGE FLOOR PROTECTIVE PANEL WAS REMOVED TO INSPECT THE BAGGAGE FLOOR PANEL. CORROSION WAS NOTED AROUND AN INSERT AREA AND FURTHER INVESTIGATION FOUND THAT CORROSION HAD PENETRATED THE UPPER SKIN, AND WAS MOVING INTO THE HONEYCOM
Back to JASC 5321