SDR FDEA201006031798Floor Panel · delaminatedWHEEL WELL FLOOR PANEL 147 AF IS DELAMINATED. FABBED NEW FLOOR PANEL USING THE OLD PANEL AS A TEMPLATE. KNOCKED BACK CORE EDGES, POTTED, CURED AND INSTALLED INSERTS IN PANEL 147 AF. INSTALLED NON-SKID AND PART MARKED IAW DWG SRZ 25-005, REV "H".SDR FDEA201006031797Floor Panel · delaminatedWHEEL WELL FLOOR PANEL 143 CF IS DELAMINATED. FABRICATED NEW W/ W FLOOR PANEL 143 CF IAW DWG SRZ 25-005, REV "H".SDR IPXA10560345Floor Panel · damagedINSPECTION TYPE:C4, DUE TO FLOORBEAM SPLICE, FLOOR PANEL ATTACHING HOLES WILL FALL OUT IN RADIUS, FLOOR PANEL REQUIRES REPALCEMENT, FROM BS 1055-1100 LBL 25-45. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560344Floor Panel · damagedINSPECTION TYPE:C4, DUE TO FLOORBEAM SPLICE, FLOOR PANEL ATTACHING HOLES WILL FALL OUT IN RADIUS, FLOOR PANEL REQUIRES REPLACEMENT, FROM BS 1100-1200 LBL 25-45. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR FDEA201006031808Floorboard · crackedAFT CARGO COMPARTMENT FLOORBOARD 151 XF IS CRACKED ACROSS THE CTR OF THE BOARD. FABRICATED FLOORBOARD 151 XF IAW DWG SRZ 25-005, REV "H" AND SRZ 25-011, REV "C".SDR FDEA201006031800Floor Panel · delaminatedWHEEL WELL FLOOR PANEL 147 DF IS DELAMINATED. FABRICATED NEW W/W FLOOR PANEL 147 DF IAW DWG SRZ 25-005, REV "H".SDR FDEA201006031796Floorboard · crackedFWD CARGO COMPARTMENT FLOORBOARD 132 JG HAS MULTIPLE CRACKS. FABRICATED NEW FWD CARGO COMPARTMENT FLOORBOARD 132 JG IAW DWG SRZ 25- 005, REV "H".SDR FDEA201006031795Floorboard · damagedFWD CARGO COMPARTMENT FLOORBOARD 132 HG HAS EDGE DAMAGE AND MULTIPLE PUNCTURES ON THE BOTTOM. FABRICATED NEW FWD CARGO COMPARTMENT FLOOR BOARD 132 HG IAW DWG SRZ 25- 005, REV "H".SDR FDEA201006031794Floorboard · damagedAFT CARGO COMPARTMENT FLOORBOARD 152 XF EDGE IS DAMAGED AND THE BOTTOM IS TORN. FABRICATED NEW AFT CARGO COMPARTMENT FLOORBOARD 152 XF IAW DWG SRZ 25-005, REV "H".SDR FDEA201006031793Floorboard · brokenAFT CARGO COMPARTMENT FLOORBOARD 151 VF CORNER AND EDGE FILLER IS BROKEN. FABRICATED NEW AFT CARGO COMPARTMENT FLOORBOARD 151 VF IAW DWG SRZ 25- 005, REV "H".SDR FDEA201006031792Floorboard · puncturedBULK CARGO COMPARTMENT FLOORBOARD 161 JF TOP SURFACE HAS MULTIPLE DENTS AND DELAMINATION. FABRICATED NEW BULK CARGO COMPARTMENT FLOOR BOARD 161 AF IAW DWG SRZ 25-005, REV "H" AND DWG SRZ 25-011, REV "C".SDR FDEA201006031791Floorboard · puncturedBULK CARGO COMPARTMENT FLOORBOARD 162 HF TOP SURFACE IS PUNCTURED, DENTED AND CORRODED. FABRICATED NEW BULK CARGO COMPARTMENT FLOOR BOARD 162 HF IAW DWG SRZ 25- 005, REV "H" AND DWG SRZ 25-011, REV "C".SDR FDEA201006031790Floorboard · puncturedBULK CARGO COMPARTMENT FLOORBOARD 161 AF TOP SURFACE IS PUNCTURED, HAS MULTIPLE DENTS AND LARGE AREAS OF DELAMINATION. FABRICATED NEW BULK CARGO COMPARTMENT FLOORBOARD 161 AF IAW DWG SRZ 25- 005, REV "H" AND DWG SRZ 25-011, REV "C".SDR IPXA10160428Floor Panel · misrepairedINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR 161GF REQUIRES REPLACEMENT IAW EO A300-5320-16407-D. FABRICATED BULK CARGO FLOOR PANEL NR 161GF IAW EO A300-5320-16407-D, APPENDIX D.SDR IPXA10160374Floor Panel · unknownINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR 161JF REQUIRES REPLACEMENT IAW EO A300-5320-16407-D. FABRICATED BULK CARGO FLOOR PANEL 161JF IAW EO A300-5320-16407-D APPENDIX D.SDR IPXA10160373Floor Panel · unknownINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR161HF REQUIRES REPLACEMENT IAW EO A300-5320-16407-D. FABRICATED BULK CARGO COMP FLOOR PANEL NR161HF IAW EO A300 5320-16407-D APPENDIX D.SDR IPXA10160372Floor Panel · unknownINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR 162HF REQUIRES REPLACEMENT IAW UPS EO A300-5320-16407-D. FABRICATED BULK CARGO FLOOR PANEL NR 162HF IAW UPS EO A300-5320-16407-D, APPENDIX D.SDR IPXA10160371Floor Panel · damagedINSPECTION TYPE:5YR, MCD FLOOR PANEL NR 261AH REQUIRES REPLACEMENT IAW UPS EO A300-5320-16407-D. FABRICATED FLOOR PANEL NR 261AH IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10660160Floor Panel · puncturedREF D425460 MAIN CARGO DECK, POSITION 2, OTBD FLOOR PANEL PUNCTURED. STA 434, RBL 83. ACCOMPLISHED MAJOR REPAIR IAW EO B767-5320-9693-G.SDR P5CA2010052901639Floor Panel · delaminatedMAIN DECK BS 1600 TO 1720 FLOOR PANEL DELAMINATED. TIME LIMITED REPAIR ACCOMPLISHED PER ENGINEERING ORDER 4453A366, WITH FAA 8110-3 DATED 29 MAY 2010. REPEAT DVI EVERY 25 FLIGHT CYCLES. PERMANENT REPAIR WITHIN 1000 FLIGHT HOURS.SDR DALA1011363262Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR PANEL 231AF. REPLACED FLOOR PANEL ON WORK CARD NR 5242-01006-01.SDR ASOA201000827Pressure Panel · crackedPRESSURE FLOOR SUSPECTED CRACK AT APPROX RBL 30R, FS 499.00. PERFORMED EDDY CURRENT INSP OF SUSPECTED CRACK ON PRESSURE FLOOR. NO INDICATIONS NOTED AT THIS TIME.SDR DALA1011163266Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 261EF. REPAIRED IAW SRM 53-02-00 FIG 209.SDR DALA1011153266Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 261PF. REPAIRED IAW SRM 53-02-00 FIG 209.SDR IPXA10560117Splice · corrodedINSPECTION TYPE:C4, FLOOR PANEL SPLICE IS CORRODED IN AFT CARGO BAY BS 1510 REPLACED SPLICE STRAP IAW SRM 51-40-05, SRM 51-40-08-0G, SRM 51-40-02, SRM 53-00-53-1A, AMM 51-21-04-7, AMM 51-21-10-7, SRM 53-60-53-0I.SDR IPXA10560116Splice · corrodedINSPECTION TYPE:C4, FLOOR PANEL SPLICE IS CORRODED IN AFT CARGO BAY BS 1330. REPLACED SPLICE STRAP IAW SRM 53-00-53-1A, SRM 51-40-05-0G, SRM 51-40-08-0G, AMM 51-21-04-7, AMM 51-21-10-7, SRM 51-40-02-0G, SRM 53-60-53-01.SDR IPXA10560110Floor Panel · damagedMCD POSITION 1 RT INBD FLOORBOARD PANEL DAMAGED (PNL MARKED 4F) REMOVED FOR REPAIR PANEL PN 141N5410-6. IDENTIFIED AS A MAJOR REPAIR TRANSFERRED TO N/R 415800 REPLACEMENT PANEL FABRICATED IAW EO B7575320-9692-G, 0559106 5/23/10 OK TO INSTALL PANEL 0559189 5/2SDR IPXA10560109Floor Panel · damagedMCD POSITION 1, LT INBD FLOORBOARD DAMAGED (PNL MARKED 3F) REMOVED FOR REPAIR PANEL PN 141N5410-5. IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO N/R 415796, 0559106 5/23/10 F, FABRICATED NEW PANEL IAW EO B757-5320-9692, G 0559106 5/23/10. OK TO INSTALL PANEL. RSSDR IPXA10560106Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL DAMAGED PANEL MARKED 2F REMOVED FOR REPAIR PANEL PN 141N5410-4. IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO N/R 415795 FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692G 0559106 5-23-10 OK TO INSTALL PANEL 0559189 5/23/10 PANEL 2F SDR IPXA10560105Floor Panel · damagedMCD POSITION NR 1 LT OTBD FLOOR PANEL DAMAGED (PANEL MARKED 1F) REMOVED F/O FOR REPAIR PANEL PN 141N5410-3 IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO NR 415794 FABRICATED PANEL IAW EO B757-5320-9692-G, OK TO INSTALL PANEL RSC 0559189 5/23/10, PANEL 1F INSTALLEDSDR ASOA201000822Pressure Panel · crackedREQUEST NDT ON PRESSURE FLOOR FOR POSSIBLE CRACK AT APPROX RBL 30R, FS 499.00.SDR IPXA10M60281Floor Panel · corrodedINSPECTION TYPE:4C, UPON REMOVAL OF MYLAR & MOONMAT AT COURIER AREA FOUND CORROSION ON FLOOR PANEL FWD OF RCB LBL 9.5. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STASA EA 011-5320-01-A2340 REV IR AND EO MD11-5310-38057-A, RESTORED AREA.SDR IPXA10M60280Floor Panel · corrodedINSPECTION TYPE:4C, UPON REMOVAL OF MYLAR & MOON MAT AT COURIER AREA FOUND CORROSION ON FLOOR PANEL FWD OF RCB LBL 69. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STA SA EA 011-5320-01-A2348 REV IR & UPS EO MD11-5310-38056-A, RESTORED AREA.SDR IPXA10M60279Floor Panel · corrodedINSPECTION TYPE:4C, UPON REMOVAL OF MYLAR & MOONMAT AT COURIER AREA FOUND CORROSION ON FLOOR PANEL FWD OF RCB LBL 20. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STA SA EA NR 011-5321-01-A2350 REV IR AND UPS EO MD11-5310-38044-A, RESTORED AREA.SDR IPXA10M60278Floor Panel · corrodedINSPECTION TYPE:4C, UPON REMOVAL OF MYLAR & MOONMAT AT COURIER AREA FOUND CORROSION ON FLOOR PANEL FWD OF RCB LBL 35. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STA SA EA 011-5320-01-A2353 REV IR AND UPS EO MD11-5310-38042-A, RESTORED AREA.SDR IPXA10M60277Floor Panel · corrodedINSPECTION TYPE:4C, UPON REMOVAL OF MYLAR AND MOONMAT AT COURIER AREA FOUND CORROSION ON FLOOR PANEL FWD OF RCB LBL 46.5. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STASA EA NR 011-5320-01-A2342 REV IR AND UPS EO MD11-5310-38019-A, RESTORED ARSDR IPXA10M60276Floor Panel · corrodedINSPECTION TYPE:4C, UPON REMOVAL OF MYLAR AND MOONMAT FOUND CORROSION AT COURIER AREA FWD OF RCB FLOOR PANEL LBL 58-59. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STASA EA NR 011-5321-01-A2351 REV IR AND UPS EO MD11-5310-38045-A, RESTORED AREASDR IPXA10M60275Floor Panel · corrodedINSPECTION TYPE:4C, FOUND CORROSION ON FLOOR PANEL FWD OF RCB, LBL7.5. GAINED ACCESS, REMOVED CORROSION, REPAIRED FLOOR PANEL REF STA SA EA NR011-5321-01-A2352, REV IR AND UPS EO MD11-5310-38041-A, RESTORED AREA.SDR IPXA10660166Floor Panel · puncturedINSPECTION TYPE:7C, MCD STA 731 TO 833, LBL 11 TO RBL 11 FLR PANEL FND SEVERAL PUNCTURES TOGETHER WITH 6 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660165Floor Panel · puncturedINSPECTION TYPE:7C, MCD STA 731 TO 833, LBL 55 TO LBL 77 FLOOR PANEL FND PUNCTURE 1.5"X2" AT 2 LOCATIONS TOGETHER WITH 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660164Floor Panel · damagedINSPECTION TYPE:7C, MCD STA 1197+22 TO 1197+110, RBL 77 TO RBL 88 FLR PANEL FOUND DAMAGED WITH 3 PUNCTURES AND 3 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10560140Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO BAY NR 3 FLOOR PANEL IS CORRODED ON THE UPPER SURFACE. REMOVED, FABRICATED, AND INSTALLED NR FLOOR PANEL IAW SRM 51-10-07-0G, SRM 53-00-53-1A, SRM 51-40-02-0G.SDR IPXA10560115Splice · corrodedINSPECTION TYPE:C4, AFT CARGO COMPARTMENT, NR 3 FLOOR PANEL SPLICE IS CORRODED. REPLACED SPLICE STRAP IAW SRM 53-00-53-1A, SRM 51-40-05-0G, SRM 51-40-08-0G, AMM 51-21-04-7, AMM 51-21-10-7, SRM 51-40-02-0G, SRM 53-60-53-0I.SDR FDEA201005241623Floor Panel · damagedMAIN CABIN FLOOR PANEL 241 UF FABRICATED FLOOR PANEL 241 UF IAW DWG SRZ 25-005, REV "H".SDR IPXA10660169Floor Panel · crackedINSPECTION TYPE:7C, DMI NR D423985 - MCD POS 7R FLOOR PANEL HAS 3.5" BY 2.5" DENT WITH .7500" CRACK. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660168Floor Panel · dentedINSPECTION TYPE:7C, DMI NR D424945 MCD FLOOR PANEL DENT AT POS 11L. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10660167Floor Panel · damagedINSPECTION TYPE:7C, DMI NR D424915 - R UPR MAIN CARGO DECK FLR PANEL DAMAGED AT POS 7L. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10560142Floorboard · damagedINSPECTION TYPE:C2, FLOORBOARD DAMAGED STA 1100 - 1200, RBL 45 - 60 FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10560138Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO FLOOR PANEL CORRODED BS 505 TO 545. FABRICATED NEW PANEL IAW SRM 53-00-53-1A.SDR IPXA10560108Floorboard · damagedMCD POSITION 2 LT OTBD DAMAGED (PANEL MARKED 1A) FLOORBOARD REMOVED FOR REPAIR PANEL PN 143N5457-101. IDENTIFIED AS MAJOR REPAIR TRANSFERRED TO N/R 415797 0559106 5/23/10 PANEL FABRICATED IAW EO B757-5320-9692G, OK TO INSTALL.
Back to JASC 5321