JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10559966Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD DAMAGED IN NUMEROUS SPOTS, BOTTOM SIDE BS 620-720 LBL 45-65. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-B.SDR IPXA10559963Floor Panel · puncturedINSP TYPE:C2, MCB FLOOR PANEL HAS PUNCTURE DAMAGE, LBL 25-45, BS 440 TO BS 480, WL 208. REPLACED FLOOR PANEL IAW EO NR B757-5320-9692 G.SDR IPXA10559962Floor Panel · dentedINSPECTION TYPE:C2, MAIN CARGO BAY FLOORBOARD PANEL BS 1060-1100 LBL 45-62 IS DENTED. REPLACED FLOOR PANEL IAW EO B757-5320-9692G AND B757-5100-33281B.SDR IPXA10559960Floor Panel · brokenINSPECTION TYPE:C2, MCB FLOOR PANEL IS BROKEN AT 2 INSERTS, BS 820 TO 880, LBL 45 TO LBL 60, WL 208. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G; EO B757-5100-33281.SDR IPXA10559959Floor Panel · delaminatedINSP TYPE:C2, MAIN CARGO STA 340 TO STA 440 FLOORBOARD IS DELAMINATED NUMEROUS PLACES AT LOWER SURFACE. REPLACED FLOOR PANEL IAW EO NR B757-5320-9692 CH.SDR USAA2010052491027Floorboard · delaminatedPIT - MAJOR REPAIR - S2 CHECK - GALLEY FLOORBOARD 231CF HAS AREA OF DELAMINATION. REPLACED GALLEY FLOORBOARD 231CF IAW MGGILL IRM 9701 REVISION G.SDR USAA2010052491026Floorboard · delaminatedPIT - MAJOR REPAIR - S2 CHECK - CABIN FLOORBOARD 262HG HAS 2 AREAS OF DELAMINATION. REPLACED CABIN FLOORBOARD 262HG IAW MGGILL IRM 9701 REVISION G.SDR USAA2010052491025Floor Panel · delaminatedPIT - MAJOR REPAIR - S2 CHECK - CABIN FLOORBOARD 262EF HAS SEVERAL AREAS OF DELAMINATION. REPLACED CABIN FLOORBOARD 262EF IAW MGGILL IRM 9701 REVISION G.SDR DALA1010173266Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON MAIN CABIN FLOOR PANEL 222FF. INSTALLED REPLACEMENT PANEL IAW CARD NR 2500-6617.SDR IPXA10560459Floorbeam · corrodedINSPECTION TYPE:C4, FLOOR SUPPORT FLANGE CORRODED AT BS 1016, LBL 25 TO LBL 45, WL 208. REMOVED FABRICATED AND REPLACED FLOOR SUPPORT TEE IAW SRM 51-40-05, SRM 51-10-02-0G STG R NR 8.SDR IPXA10560199Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO STA 1400, LBL 60 FLOOR PANEL HAS 1EA INSERTS MISSING. FLOOR PANEL ORIGINAL FOUND TO BE OUT OF LIMITS IAW SRM 53-00-50-IA 1 LOCATED MATERIAL, THEN CUT OUT SIZE, DRILLED AND INSTALLED INSERTS APPLIED SAFETY WALK NON-SKID FINISH.SDR IPXA10560129Floor Panel · dentedINSPECTION TYPE:C4 MCB FLOORBOARD PANEL DENTED BS 900 - 1016 LBL 45 - 62 FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10160020Floorboard · crackedINSPECTION TYPE:5YR, FLOORBOARD 231LJ IS CRACKED AT UPPER SKIN INBD EDGE FABRICATED FLOORBOARD 231LJ IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10160017Floor Panel · crackedINSPECTION TYPE:5 YR FLOOR PANEL 231PJ IS DELAMINATED AT FWD CTR AND CRACKED AT AFT INBD CORNER. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. B.SDR IPXA10160016Floor Panel · damagedINSPECTION TYPE:5 YR, BULK CARGO PANEL 161GF REQUIRES REPLACING. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. D.SDR IPXA10560010Floorboard · damagedINSPECTION TYPE:C4, MCB FLOORBOARD PANEL DAMAGED BS 1016-1055 LBL 45-62. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10560009Floorboard · damagedINSPECTION TYPE:C4, DAMAGED FLOORBOARD AT 1100-1200 LBL 45-62. FABRICATED REPLACEMENT PANEL.SDR IPXA10560008Floor Panel · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1681.8 TO STA 1661 FLOOR PANEL HAVE 4 EA INSERTS CORRODED BL 0 TO RBL 24.75. FABRICATED REPLACEMENT PANEL.SDR IPXA10560007Floor Panel · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1420 TO STA 1540, LBL 45.5 TO LBL 60 FLOOR PANEL HAVE 8 EA INSERTS CORRODED FABRICATED REPLACEMENT PANEL.SDR IPXA10560006Floorboard · dentedINSPECTION TYPE:C4, MCB FLOORBOARD PANEL DENTED BS 900-1016 LBL 45-62. FABRICATED REPLACEMENT PANEL.SDR IPXA10560005Floorboard · damagedINSPECTION TYPE:C4 MCB FLOORBOARD PANEL DAMAGED BS 1055-1100 LBL 45-62. FABRICATED REPLACEMENT PANEL.SDR IPXA10159998Floorboard · damagedINSPECTION TYPE:5YR, MAIN CARGO COMPARTMENT FLOOR PANEL 262DM REQUIRES REPLACING IAW EO A300-5320-16407-D. FABRICATED FLOORBOARD 262DM IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10159996Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD 231NJ IS CRACKED AT FWD EDGE FABRICATED FLOORBOARD 231NJ IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10160151Floorboard · brokenINSPECTION TYPE:5 YR, MAIN CARGO COMPARTMENT NR 241 NK FLOORBOARD AT FWD CORNER EDGE BROKEN OFF. FABRICATED REPLACEMENT FLOOR PANEL NR241 NK IAW EO 300-5320-16407-D, APPENDIX A AND B.SDR IPXA10560119Floorboard · damagedINSPECTION TYPE:C4, CREW COMPARTMENT UPPER FLOORBOARD HAS MULTIPLE AREAS OF DAMAGE ON EDGE, A PUNCTURE, CORROSION ON INSERTS REPLACED IAW EO B757-5320-9692.SDR IPXA10160014Floor Panel · damagedINSPECTION TYPE:5 YR, FLOOR PANEL 131AH IN FWD CARGO REQUIRES REPLACING FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. C.SDR IPXA10159997Floorboard · delaminatedINSPECTION TYPE:5YR, MAIN CARGO COMP FLOOR PANEL 231VG HAS DELAMINATED AREA. FABRICATED FLOORBOARD 231VG IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10159970Floor Panel · brokenINSPECTION TYPE:5 YR, MAIN CARGO COMPARTMENT NR 251UJ FLOOR PANEL AT AFT OTBD CORNER IS BROKEN OFF. FABBED FLOOR PANEL 251UJ IAW UPS EO A300-5320-16407-D, APPX B.SDR IPXA10159968Floorboard · crackedINSPECTION TYPE:5YR, MAIN CARGO COMPARTMENT NR 252 WG FLOORBOARD AT INBD CTR AREA IS CRACKED. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. BSDR IPXA10559881Floorboard · damagedFLOORBOARD DAMAGED. FABRICATED NEW FLOOR IAW EO B757-5320-9692-G.SDR IPXA10659874Floor Panel · puncturedMAIN CARGO POSITION 6L MOST OTBD FLOOR PANEL HAS 2 SMALL PUNCTURES. 2 SMALL PUNCTURES IN ZONE 1 THROUGH FIRST PLY ONLY. FIRST MEASURES .5" BY .1280", SECOND MEASURES .5" BY .2500" AND ARE 4 INCHES APART FROM EACH OTHER. ACCOMPLISHED MAJOR REPAIR IAW EO B76SDR IPXA10159957Floorboard · crackedINSPECTION TYPE:5YR, MAIN DECK FLOOR PANEL NR 251DF IS CRACKED. FABRICATED FLOOR PANEL 251DF IAW EO A300-5320-16407-D, APPENDIX B.SDR AALA20100513TUL04Floorboard · corrodedCORROSION ON FLOORBOARD STRUCTURE RIGHT BUTTLINE 54 STATIONS 750 TO 770. COMPLETED INSTALLATION OF CHORD ANGLE AND SPLICE PER AARD 53-30-13-1.SDR F3LA2010052200426Floor Panel · debondedREF HEAVY MX NON ROUTINE N0733. FWD CARGO FLOOR PANEL 131AF DISBONDED AT CORNERS. REPAIRED IAW SRM 53-02-00, PAGE 208, FIG 203.SDR IPXA10560136Floor Panel · corrodedINSPECTION TYPE:C1, UPPER SURFACE OF THE COCKPIT FLOOR IS CORRODED AT BS 285.5 LBL 6 WL 197. R & R IAW SRM51-40-02-0G, 51-40-08-0G, 51-40-06-0G AND 51-40-05-0G.SDR IPXA10M60100Floor Panel · corrodedINSPECTION TYPE:4C, GALLEY AREA FLOOR PANEL CORRODED UNDER MYLAR AT CUTOUT FOR WATER SUPPLY/DRAIN FITTINGS. REPAIRED RCB FLOOR PANEL REF STA SA EA 011-5320-01-A2321, REV IR AND EO MD11-5310-37866-A.SDR IPXA10559917Floor Panel · corrodedINSPECTION TYPE:C1, UPPER SURFACE OF THE COCKPIT FLOOR IS CORRODED AT BS 287, LBL 20, WO 197. REPAIR COCKPIT FLOOR WEB IAW SRM 51-70-13-0G.SDR ASOA201000726Pressure Panel · crackedFOUND FS 460 PRESSURE FLOOR HAS INDICATION NOTED BETWEEN BL 0.0 TO LBL 9.0 FWD OF INTERCOSTAL 2.7" IN LENGTH 70 PERCENT FSH. FAILED NDT INSPECTION. INDICATION MARKED ON ACFT. REPAIR FOR THE PRESSURE FLOOR WEB AT FS 464.00 ON ACFT SN 7203 IS COMPLETED IAW REO SDR F3LA2010052200429Floor Panel · debondedREF HEAVY MX NON ROUTINE N0601. AFT CARGO FLOOR PANEL 152UG DISBONDED. FABRICATED NEW PANEL IAW MCG IRM 9701 REV G.SDR F3LA2010052200428Floor Panel · debondedREFERENCE HEAVY MX NON ROUTINE N0639. AFT CARGO PANEL 151UG DISBONDED. FABRICATED NEW PANEL IAW NCG IRM 9701 REV G.SDR F3LA2010052200427Floor Panel · debondedREF HEAVY MX NON ROUTINE N0654 AFT CARGO FLOOR PANEL 151FE DISBONDED. FABRICATED REPLACEMENT PANEL IAW MCG IRM 9701 REV G.SDR IPXA10159958Floor Panel · damagedINSPECTION TYPE:5YR, BULK PIT FLOOR PANEL NR 162HF REQUIRES REPLACING IAW EO A300-5100 -16407-D. FABRICATED NEW FLOOR PANEL NR 162HF IAW EO A300-5320-16407-D, APPENDIX D.SDR IPXA10659749Floor Panel · damagedMAIN CARGO DECK FLOOR AT POS 6L HAS 1" HOLE IN IT. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10659748Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL AT POS 6 L HAS .6250 X .2500 HOLE. REPAIRED IAW SRM 53-00-50-22R.SDR F3LA2010052200424Floor Panel · delaminatedREFERENCE HEAVY MAINTENANCE NON ROUTINE N0366. COCKPIT FLOOR PANEL 211GF IS DELAMINATED. REPAIRED PANEL IAW SRM 5302-00.SDR USAA2010051190946Floorboard · delaminatedPIT - S4 - MAJOR REPAIR - DELAMINATION ON FLOORBOARD 251LF BETWEEN FR54 TO FR58 & BETWEEN Y254 TO -Y254. REPLACED FLOORBOARD 251LF BETWEEN FR54 TO FR58 & BETWEEN Y254 TO -Y254 IAW MCGILL IMR 9701 REV G.SDR USAA2010051190945Floorboard · delaminatedPIT - S4 - MAJOR REPAIR - DELAMINATION ON FLOORBOARD 251SF BETWEEN FR58 TO FR62 & BETWEEN Y254 TO Y765. REPLACED FLOORBOARD 251SF BETWEEN FR58 TO FR62 & BETWEEN Y254 TO Y765 IAW MCGILL IMR 9701 REV G.SDR USAA2010051190943Floorboard · delaminatedPIT - S4 - MAJOR REPAIR - DELAMINATION ON FLOORBOARD 252SF BETWEEN FR58 TO FR62 & BETWEEN -Y254 TO -Y765. REPLACED FLOORBOARD 252SF BETWEEN FR58 TO FR62 & BETWEEN -Y254 TO -Y765 IAW MCGILL IMR 9701 REV G.SDR IPXA10B59747Floor Panel · puncturedMCD FLOOR PANEL HAS 3 PUNCTURES AT FWD EDGE AND 1 IN MIDDLE OF PANEL REPAIRED IAW 747-400F, SRM 53-00-50-2R, REPAIR NR1.SDR IPXA10659746Floor Panel · damagedMAIN DECK FLOORBOARD POSITION 4R HAS 2 AT HOLES. HOLES MEASURE .2500" X .3750" AND .2500" X .5". REPAIRED IAW 53-00-50-2R.
Back to JASC 5321