SDR IPXA10659739Floor Panel · puncturedMAIN CARGO DECK FLOOR PANEL AT POS 8R HAS 1 " HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10659738Floor Panel · puncturedMC FLOOR PANEL AT POS 8L HAS 1" HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10659737Floor Panel · damagedMAIN DECK FLOOR PANEL AT POS 12L HAS 1" HOLE. REPAIRED IAW 767SRM 53-00-50-2R.SDR IPXA10659736Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL HAS 2 HOLES. HOLES MEASURES 6.7500 X 3.5 AN D 3.5 DIAMETER. REPAIRED IAW SRM 53-00-50.SDR IPXA10659735Floor Panel · puncturedMAIN CARGO DECK FLOOR PNL AT POS 12L OTBD HAS 1 1/4 X 1 HOLE THUR BOTH SKINS FABRICATED PNL IAW EO B767-5320-9693-G.SDR IPXA10559743Floor Panel · damagedMAIN DECK FLOOR PANEL LT POS NR 1 DAMAGED. MFG AND INSTALLED NEW FLOOR PANEL IAW EO B757-5320-9692 AND SRM 53- 00-50.SDR IPXA10159925Floorboard · separatedINSPECTION TYPE:10YR, L-1 DOOR FWD GIRTBAR FLOORBOARD SEPARATED. FABBED FLOOR PANEL IAW EO A300-5320-16407-D, APPX B.SDR DALA109653265Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FWD CARGO FLOOR PANEL 131HF. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA109643265Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO AFT CARGO FLOOR PANEL 131EF. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA109633265Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO AFT CARGO FLOOR PANEL 131AF. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA109623265Floor Panel · crackedDURING M-CHECK FOUND CRACK IN AFT CARGO FLOOR PANEL 151DF. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA109613265Floor Panel · delaminatedDURING M-CHECK FOUND DELAMINATION IN AFT CARGO FLOOR PANEL 161DF. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA109603265Floor Panel · crackedDURING M-CHECK FOUND CRACK IN AFT CARGO FLOOR PANEL 151LF. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR USAA2010051190944Floorboard · delaminatedPIT - S4 - MAJOR REPAIR - DELAMINATION ON FLOORBOARD 251WF BETWEEN FR62 TO FR64 & BETWEEN Y765 TO -Y765. REPLACED FLOORBOARD 251WF BETWEEN FR62 TO FR64 & BETWEEN Y765 TO -Y765 IAW MCGILL IMR 9701 REV G.SDR IPXA10659880Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT BS 985 TO 1087 LBL 77" TO LBL 88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659878Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT BS 764 TO 873 LBL 77" TO LBL 88". FLOOR PANEL FABRICATE IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659845Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH WITH PUNCTURE HOLE AT BS 873 TO 933 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659844Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH WITH PUNCTURE HOLE AT BS 933 TO 985 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659814Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT BS 1087 TO 1197+22 LBL77" TO LBL88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01SDR IPXA10659813Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT STN1197+22 TO 1207 LBL77" TO LBL88". FLOOR PANEL FABRICATED AS IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659811Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND DEEP AND LONG GROOVE RUN THROUGH AT STN 1207 TO 1351 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10159834Floor Panel · delaminatedINSPECTION TYPE: 10YR AFT CARGO FLOOR PANEL 151UF IS DELAMINATED, CRACKED IN NUMEROUS AREAS. FABRICATED FLOOR PANEL 151UF IAW EO A300-5320-16407-D APP C.SDR IPXA10159779Floor Panel · crackedINSPECTION TYPE:10YR, AFT CARGO FLOOR PANEL NR 151VF CRACKED IN HALF FOUND AFTER RECHECKING OF ACFT PARTS FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. C.SDR DALA109473260Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL NR 241HF BOTTOM SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR IPXA10659879Floor Panel · puncturedINSPECTION TYPE:C, DMI D423102 HOLE REPAIR MCD POS 7, RT 25 INCHES FROM AFT EDGE & 4.5" INBD LT SIDE. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659877Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 2" X 2.5" AT BS 985 TO 1087 RBL 77" TO RBL 88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659869Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND LONG AND DEEP GROOVE RUN THROUGH THE PANEL AT BS 540 TO 654+22 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659868Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 3 PUNCTURE HOLES 1.75" X 1.5" AND 1" X 1.25" AT BS 412 TO 540 LBL 11" TO RBL 11". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED AMM 53-01-01.SDR IPXA10659867Floor Panel · gougedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND LONG DEEP GOUGE AND TEAR AT BS 412 TO 540 RBL 55" TO RBL 77". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659866Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.5" X 2.5" AT BS 412 TO 540 RBL 33" TO RBL 55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659865Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 2 PUNCTURE HOLE 1.2" X 1.5" AND 1.2" X 1.8" AT BS 1480 TO 1598 RBL 33" TO RBL 55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659864Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND LONG AND DEEP GROOVE RUN THROUGH THE PANEL AT BS 690 TO 764 LBL 77" TO LBL 88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659863Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.5" X 1.75" AT STN1480 TO 1598 LBL33" TO LBL55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659843Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.5" X 2" AT BS 764 TO 873 RBL 77 TO RBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659842Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND (2) PUNCTURE HOLES 1.5" X 2" AND 1.75" X 2" AT BS 873 TO 935 RBL 77 TO RBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659841Floor Panel · groovedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND LONG AND DEEP GROOVE RUN THROUGH THE PANEL AT BS 654+22 TO 690 LBL 77 OT LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659818Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.5" X 1.75" AT STN731 TO 833 RBL33" TO RBL55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659812Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND PUNCTURE HOLE 1.2" X 1.5" AT BS 1351 TO 1480 LBL 77 TO LBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR DALA109323220Floorboard · delaminatedDURING LINE CHECK FOUND AISLE FLOORBOARD PANEL 241JF DELAMINATED. REPLACED FLOOR PANEL IAW AMM 53-22-12-400-001.SDR IPXA10B59605Floor Panel · damagedDMG TO MAIN CARGO DECK FLOOR PANEL 21" FROM FWD EDGE 2.0" FROM OTBD EDGE. DMG IS APPROX 2.0" FORE/AFT AND 1.0" IN WIDTH AND .025 DEEP REF EO B747-5320-36566-A FOR DWG. REPAIRED IAW SRM 53-00-50-2R (4D).SDR IPXA10659598Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 11R HAS 1" HOLE 12"AFT OF FWD LOCK LINE MFG AND INSTALLED NEW PANEL IAW B767-5320-9693G AND MM53-01-06-4.SDR IPXA10659597Floor Panel · damagedMAIN DECK CARGO COMPT FLOOR DAMAGE AT POS 10R 48" FWD OF AFT EDGE 1" HOLE MFG AND INSTALLED NEW PANEL IAW B767-5320-9693G AND MM53-01-06-4.SDR IPXA10659596Floor Panel · damagedMAIN DECK CARGO COMPT FLOOR DAMAGED AT POS 7R DAMAGE LOCATED 12" AFT O OF FWD EDGE OF LT PANEL. MFG AND INSTALLED NEW PANEL IAW EO B767-5320-9693G AND MM53-01-06-4.SDR IPXA10659595Floor Panel · damagedMAIN DECK CARGO COMPT FLOOR DAMAGED AT 8L AFT OF RT PANEL 1" HOLE. MFG AND INSTALLED NEW PANEL IAW B767-5320-9693G AND B767 MM53-01-06-4.SDR IPXA10559718Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO BAY NR 3 FLOOR PANEL, IS CORRODED, OUT OF SRM LIMITS. FABRICATED FLOOR PANEL IAW SRM 51-40-05-0G, AND DWG 453N1170.SDR IPXA10559717Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO BAY, NR 4 FLOOR PANEL IS CORRODED, OUT OF SRM LIMITS. FABRICATED NEW FLOOR PANEL IAW SRM 51-40-05-0G, AND DWG 453N1170.SDR IPXA10559628Floorboard · brokenINSPECTION TYPE:C2, FLOORBOARD AT 900 TO 1020, LBL 45-65 HAS (2) BROKEN, INSERTS. REPLACED INSERTS IAW EO 757-5320-9692G STEP 5.SDR IPXA10559627Floorboard · brokenINSPECTION TYPE:C2, FLOORBOARD AT BS 900-1020 RBL 45 TO 65 HAS ONE BROKEN INSERT. REPLACED INSERT IAW EO B757-5320-9692-G.SDR IPXA10559599Floor Panel · damagedINSPECTION TYPE:C1, MAIN CABIN FLOOR PANEL BS 1420-1540 LBL 45-60 IS DAMAGED BEYOND REPAIR. FLOOR PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR USAA2010050490891Floor Panel · corrodedSAL - S1 - MAJOR REPAIR - CORROSION ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20 & BETWEEN -Y1292 TO -Y765. REPLACED FLOOR PANEL 222FF IAW JOB CARD 26C2265002.
Back to JASC 5321