SDR IPXA10659099Floor Panel · gougedINSPECTION TYPE:6C, MCD FLOOR PANEL FOUND DEEP GOUGE MARKS AT STN 540 TO STN 654+22, RBL 33" TO RBL 55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10659098Floor Panel · puncturedINSPECTION TYPE:6C, MCD FLOOR PANEL FOUND PUNCTURED AT STN 1344 TO STN 1425, RBL 55" TO RBL 77". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659097Floor Panel · puncturedINSPECTION TYPE:6C, MCD FLOOR PANEL FOUND SEVERAL PUNCTURES AT STN 1370 TO STN 1480, RBL 77" TO RBL 88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALL IAW AMM 53-01-01.SDR IPXA10659091Floor Panel · puncturedINSP TYPE:6C, MCD FLOOR PANEL FOUND PUNCTURED AT STN 833 TO STN 930, LBL 11" TO RBL 11". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659083Floor Panel · puncturedINSPECTION TYPE:6C MCD FLOOR PANEL FOUND PUNTURED AT STN 833 TO STN 930, LBL 33" TO LBL 55". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10659082Floor Panel · puncturedINSPECTION TYPE:6C, MCD FLOOR PANEL FOUND PUNCTURED AT STN 932 TO STA 985, RBL 77" TO RBL 88". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR DALA106629862Floor Panel · corrodedDURING L-CHECK FOUND CORROSION ON FWD CARGO CTR FLOOR PANEL RIBS NR 1 THRU NR 6. REPAIRED IAW SRM 51-10-4, 51-60-0, 51-30-5, 51-30-1 & DWG 9B53-35812.SDR IPXA10559102Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO BAY FLOOR PANEL NR 2 UPPER SURFACE IS CORRODED. R & R FLOOR PANEL NR 2 IN FCB IAW SRM 53-30-53-0I, SRM 51-30-01-0G, SRM 51-40-05-0G, SRM 51-20-01-0G, AND SRM 51-40-08-0G.SDR IPXA10559055Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO BAY FLOOR PANEL NR 3 UPPER SURFACE IS CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS FABRICATED NEW FLOOR PANEL FROM CLAD ALUMINUM 2024-T3. DRILLED FASTENERS, COUNTERSUNK HOLES APPLIED PRIMER AND INSTALLED PANEL IAW SSDR IPXA10559054Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO BAY FLOOR PANEL NR4 UPPER SURFACE IS CORRODED. BLENDED CORROSION AREA; FOUND FLOOR PANEL OUT OF LIMITS IAW SRM 53-00-53-IAI. FABRICATED NEW FLOOR PANEL. ALUMINUM CLAD 2024-T3 LOT 921269. ALODINED, PRIMED IAW SRM 53-30-53-0I1 SRMSDR CALA2010040500107Floor Panel · damagedPANEL (CABIN FLOOR) 241 BF IS DAMAGED. FABBED NEW PANEL 241 BF SRM 53-00-50 EA 5320-01448.SDR IPXA10659001Floor Panel · damagedFLOOR PANEL AT POS 5/6L HAS NUMEROUS HOLES. FABRICATED NEW FLOOR PANELS IAW STANDARD REPAIR EO B767-5320-9693-G.SDR IPXA10659000Floor Panel · damagedMAIN DECK FLOOR PANEL HAS HOLE. FABRICATED NEW FLOOR PANEL IAW STANDARD REPAIR EO B767-5320-9693-G.SDR DALA106423264Floor Panel · damagedDURING M-CHECK, FOUND FLOOR PANEL 131HF DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA106813264Floor Panel · corrodedDURING M-CHECK FOUND FLOOR PANEL 261FF CORRODED. REPLACED FLOOR PANEL IAW SRM 51-72-00.SDR DALA106803264Floor Panel · corrodedDURING M-CHECK, FOUND FLOOR PANEL 222FF CORRODED. REPLACED FLOOR PANEL.SDR DALA106793264Floor Panel · corrodedDURING M-CHECK, FOUND FLOOR PANEL 262FF CORRODED. REPLACED FLOOR PANEL IAW SRM 51-72-00.SDR ZZDA2010219Floor Panel · corrodedGALLEY ENTRANCE FLOOR FILLER PANEL, STA 160 TO 200, RBL 54, CORROSION. ACCOMPLISHED FLOOR FILLER PANEL REPLACEMENT PER B717 SRM 51-41-01.SDR DALA106519862Floor Panel · damagedDURING L-CHECK FOUND DAMAGE TO CABIN FLOOR PANEL NR 69. REPAIRED IAW SRM 51-30-2 AND SRM 51-30-1.SDR DALA106453264Floor Panel · dentedDURING M-CHECK FOUND FLOOR PANEL 131EF WITH MULTIPLE DENTS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA106446264Floor Panel · dentedDURING M-CHECK FOUND FLOOR PANEL 131AF WITH MULTIPLE DENTS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA106393264Floor Panel · damagedDURING M-CHECK FOUND FLOOR PANEL 262EF DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA106383264Floor Panel · damagedDURING M-CHECK FOUND FLOOR PANEL 261AB DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA106373264Floor Panel · damagedDURING M-CHECK, FOUND FLOOR PANEL 261PF DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR 2010FA0000310Finger Doubler · corroded(SPUY) DURING ROUTINE C-CHECK INSP, FLIGHT COMPARTMENT - HORIZ PRESS PANEL (SUB FLOOR) FINGER DOUBLER CORRODED AT STA 58.000 AND LBL 19.SDR IPXA10559021Floor Panel · damagedINSPECTION TYPE:C2, FLOORBOARD AFT OTBD CORNER DAMAGED BS 1020-1055, RBL 0-25, WL 208. REPLACED PANEL IAW SRM 53-00-50-1A1, EO NR B757-5320-9692-G.SDR IPXA10159058Floor Panel · delaminatedINSPECTION TYPE:3C, BULK CARGO FLOOR PANEL NR 161GF IS DELAMINATED. FABRICATED FLOOR PANEL NR 161GF IAW EO A300-5320-16407-D, APPENDIX D.SDR A6WA201040239Floor Skin · gougedGOUGE TO FLOOR SKIN UNDER FUEL PRESSURE BOX. (CAUSED BY A SCREW TRAPPED BETWEEN THE SKIN AND THE FUEL PRESSURE BOX). CUT OUT DAMAGE AND INSTALL SHIMS AT A DOUBLER IAW 601R-53-41-1185.SDR IPXA10559573Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT AFT END OF BS 1600- 1680 RBL 0-25. REPLACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559572Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT FWD END AT BS 1600-1680 RBL 45-65. REPLACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559571Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT FWD END OF BS 1600-1680 RBL 25-45. REPLACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559570Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT FWD END BS 1540- 1600 RBL 25-45. REP LACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559266Floorboard · damagedINSPECTION TYPE:C4, CABIN FLOORBOARD BS 1068-1720 LBL 0 TO 50 SEVERAL MISSING/DAMAGED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692GSDR IPXA10559096Floor Panel · damagedINSPECTION TYPE:C4, BS 1200 TO BS 1320 LBL 45 TO LBL 65 FLOOR BOARD IS DAMAGED. REPLACED PANEL IAW SRM 53-00-50-1A 1 FIG 101, EO B757-5320-9692-G.SDR IPXA10559080Floorboard · wornINSPECTION TYPE:CR, MAIN CARGO COMPARTMENT FLOORBOARD BS 560-620 RBL 45-65 TOP HAS WORN AREAS. FABRICATED NEW FLOORBOARD PANEL IAW SRM 53-00-50-1A 1 AND EO NR B757-5320-9692-G.SDR IPXA10559077Floor Panel · damagedINSPECTION TYPE:C4, BS 297-333, WL 208, RBL 10 TO LBL 65 FLOOR PANEL HAS SEVERAL DAMAGED INSERTS AND IS PUNCTURED ON LOWER SIDE. FABRICATED NEW FLOORBOARD PANEL IAW SRM 53-00-50-1A, SRM 53-00-50-2R1 EO NR B757-5320-9692G.SDR IPXA10559061Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD 480-560, RBL 24-45 HAS BROKEN OUT INSERTS. FABRICATED REPLACEMENT MAIN CARGO FLOORBOARD IAW EO NR 757-5320-9692 G.SDR IPXA10559060Floorboard · wornINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD BS 480-560 RBL 25-45 TOP HAS WORN AREAS FABRICATED NEW MAIN CARGO FLOORBOARD IAW EO NR B757-5320-9692-G.SDR IPXA10559059Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO FLOOR BOARD LT BS 560-620 LBL 45 LBL 65 BROKEN IN HALF 25" FORM AFT EDGE. FABRICATED NEW FLOORBOARD PANEL IAW EO NR B757-5320-9692-C.SDR IPXA10559053Floorboard · wornINSPECTION TYPE:C4, MAIN CARGO FLOORBOARD BS 480-560, RBL 0-25 TOP SURFACE HAS SEVERAL WORN AREAS, REPLACED.SDR IPXA10559052Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO FLOORBOARD LT BS 480-560 OTBD HAS SEVERAL PUNCTURES ON TOP SURFACE. REPLACED FLOORBOARD.SDR IPXA10559033Floorboard · damagedINSPECTION TYPE:C4, BS 340-440 RBL 0.25 WL 208 FLOORBOARD IS DAMAGED ON EDGE FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10559032Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMP FLOORBOARD LT BS 620-720, LBL 45-65 IS PUNCTURED ON BOTTOM IN SEVERAL PLACES. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10559031Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMP FLOORBOARD BS 620-720 RBL 0-25 AFT END IS DAMAGED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10559030Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMP FLOOR BOARD BS 560-620 RBL 25-45 IS PUNCTURED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10559008Floor Panel · puncturedINSPECTION TYPE:C4, MAIN CARGO FLOOR BOARD LT BS 620-720, LBL 25-45 IS PUNCTURED ON TOP. FABRICATED NEW FLOORBOARD IAW EO NR B757-5320-9692-G.SDR IPXA10559007Floor Panel · damagedINSPECTION TYPE:C4, BS 880 TO BS 900, RBL 25 TO 45 FLOORBOARD IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA10558997Floorboard · damagedINSPECTION TYPE:C4, FUSELAGE FLOOR STRUCTURE FLOOR PANEL AT LBL 45 TO LBL 60 STA 1060 TO 1100 HAS DAMAGED INSERT OTBD FWD EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10558996Floorboard · damagedINSP TYPE:C4, BS 1420 TO BS 1540, LBL 45 TO LBL 65 FLOOR BOARD IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10558995Floorboard · damagedINSPECTION TYPE:C4, BS 1720 TO BS 820, LBL 45 TO LBL 65 FLOOR BOARD IS DAMAGED. R & R FLOOR BOARD IAW EO B757-5320-9692-G.
Back to JASC 5321