SDR F3LA200800452Floor Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 162EF DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800451Floor Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 161CF DAMAGED. MAINT REMOVED DAMAGE AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800464Floor Panel · damagedDURING C-CHECK INSP NOTED FWD PIT PANEL 131EG DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800481Floor Panel · damagedDURING C-CHECK INSP, NOTED FLOOR PANEL 261PF HAD COMPOSITE DAMAGE. MAINT REMOVED AND REPLACED FLOOR PANEL 261PF WITH NEW PANEL, REFERENCED ON EAC NON ROUTINE ITEM 9651. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR 08FDEA02797Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL 232 TG; TOP SURFACE IS CRUSHED AFT OF FRAME 21. MATERIAL ID A 402 H 35039-003, PO 613022.1 IAW FEDEX DWG SRZ 25-005, REV F. PART MARKED NEW FLOOR PANEL IAW FEDEX GMM 7-0-1000.SDR 08FDEA02798Floor Panel · damagedMAIN DECK FLOORBOARD 261 UF IS BROKEN. MAT ID N 407 35039-003, PO 613022.1. FABBED A NEW PANEL IAW FEDEX SRZ 25-005; REV F. PART MARKED IAW FEDEX GMM 7-0-1000.SDR 08FDEA02795Floorboard · crackedMAIN DECK FLOOR BOARD NR 251 RT IS CRACKED. MAT ID N 407 35039-003, PO 613022.1. FABBED A NEW PANEL IAW FEDEX SRZ 25-005; REV F. PART MARKED IAW FEDEX GMM 7-0-1000.SDR 08FDEA02794Floorboard · crackedMAIN DECK FLOORBOARD NR 251 XF IS CRACKED. MAT ID N 407 35039-003, PO 613022.1. FABBED A NEW PANEL IAW SRZ 25-005; REV F. PART MARKED IAW GMM 7-0-1000.SDR 08FDEA02793Floor Panel · damagedMAIN DECK FLOORBOARD 262 WF IS BROKEN. MATERIAL ID N 407 35039-003, PO 613022.1 AND FABBED A NEW PANEL IAW FEDEX DWG SRZ 25-- 5; REV F. PART MARKED IAW FEDEX GMM 7-0-1000.SDR F3LA200800434Floorboard · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151BE HAS A PUNCTURE IN IT. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 151BE IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800433Floorboard · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151TG HAS A PUNCTURE IN IT. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 151TG IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800432Floorboard · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151DE HAS A PUNCTURE IN IT. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 151DE IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800431Floor Panel · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 152TG HAS A PUNCTURE IN PANEL. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 152TG IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800430Floorboard · puncturedREFERENCE NON ROUTINE 36564. DURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151AE IS PUNCTURED. MAINT CLEANED PREPPED AND REPAIRED FLOORBOARD 151AE IAW OF SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUNSDR F3LA200800429Floorboard · puncturedDURING C-CHECK INSP NOTED CABIN FLOORBOARD 242FF IS PUNCTURED IN THE CENTER OF THE PANEL. MAINT PREPPED FLOORBOARD 242FF FOR REPAIR AND REPAIRED IAW SRM 53-12-00 PARAGRAPH 5B FIGURE 202. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800428Floorboard · crackedDURING C-CHECK INSP NOTED FLOORBOARD 251HF HAS A CRACK IN THE TOP OF THE BOARD. MAINT PREPPED AREA OF DAMAGE ON FLOORBOARD 251HF FOR REPAIR AND REPAIRED IAW ARM 53-12-00 PARAGRAPH 5B FIGURE 202. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABSDR F3LA200800426Shear Plate · corrodedDURING C-CHECK INSP, NOTED CORROSION AROUND FAR RT NUTCLIP HOLE ON SHEAR PLATE ALONG FRAME 68 BETWEEN Y765 AND Y1292. MAINT REMOVED, FABRICATED AND INSTALLED SERVICEABLE SHEAR PLATE AT FRAME 68 BETWEEN Y765 AND Y1292 IAW DRAWING O53670099, SRM 51-21-11, SRM 51SDR F3LA200800425Floor Panel · corrodedDURING C-CHECK INSP, FLOOR PANEL 262FF HAS CORROSION ON SURFACE. MAINT REMOVED AND REPLACED FLOOR PANEL 262FF IAW AMM 53-42-12-400-002. UPON COMPLETION OF THE REPAIR, INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800424Floor Panel · corrodedDURING C-CHECK INSP NOTED FLOOR PANEL 261FF HAS CORROSION ON SURFACE. MAINT REMOVED AND REPLACED FLOOR PANEL 261FF IAW AMM 53-42-12-400-002. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR 08FDEA02730Floor Panel · crackedMAIN DECK FLOORBOARD NR 251 QH IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW FEDEX DWG SRZ 25-005; REV F. MATERIAL ID A 402 H 35039-003, PO 622013.1 IAW FEDEX DWG SRZ 25-005; REV F. PART MARKED IAW FEDEX GMM 7- 0-1000.SDR UPS08852729Floor Panel · crackedINSPECTION TYPE-C2, FLOOR PANEL F94/F94A HAS SEVERAL ELONGATED HOLES AND A CRACK AT THE EDGE, CUT OUT DAMAGE IAW SRM 53-02-03 FIG 005A. FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-02-03,AND 51-1-21.SDR F3LA200800416Floorboard · delaminatedDURING C-CHECK INSP NOTED FLOORBOARD 241FF HAS DELAMINATION ALONG THE EDGE OF THE FLOORBOARD. MAINT PREPPED AREA OF DAMAGE ON FLOORBOARD 241FF FOR REPAIR AND REPAIRED IAW SRM 53-02-00 PARAGRAPH 8J FIGURE 212. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND SDR 08FDEA02689Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL 232 AH HAS BELL BEARINGS STUCK AND PUNCTURES ON THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 FIG 202.SDR 08FDEA02688Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 ZG HAS BALL BEARINGS STUCK AND PUNCTURES ON THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02687Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 XG HAS BALL BEARINGS STUCK AND PUNCTURES ON THE TOP SURFACE. REPAIRED DAMAGED AREA PER A300-600 SRM 53-10-20, FIG 201.SDR 08FDEA02686Floorboard · damagedMAIN CABIN FLOOR PANEL 231 XG UPPER SURFACE HAS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02685Floorboard · damagedMAIN CABIN FLOOR PANEL 231 JH UPPER SURFACE HAS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02684Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 FG HAS NUMEROUS PUNCTURES AND BALL BEARINGS STUCK TO THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 201.SDR 08FDEA02683Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 CF HAS NUMEROUS PUNCTURES AND BEARINGS IN THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 201.SDR 08FDEA02682Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 GG HAS NUMEROUS PUNCTURES AND BEARINGS STUCK IN THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02681Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 SG HAS PUNCTURES AND BALL BEARINGS STUCK TO THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02680Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 TG HAS PUNCTURES AND BALL BEARINGS IN THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02679Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 UG HAS BALL BEARINGS (4 PLACES) STUCK IN THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02678Floorboard · damagedMAIN CARGO DECK FLOOR PANEL NR 232 VH HAS BALL BEARINGS (2 PLACES) STUCK IN THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02677Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 NG HAS BALL BEARINGS (2 PLACES) STUCK IN THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02676Floorboard · damagedMAIN CARGO DECK FLOOR PANEL FROM FRAME 22 TO FRAME 26, RBL 37 TO RBL 57 HAS NUMEROUS BALL BEARINGS STUCK AND PUNCTURES ON THE TOP SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02675Floorboard · damagedBALL BEARINGS ARE EMBEDDED ON THE TOP SURFACE OF PANEL NR 232 GG, MAIN CARGO DECK. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20, FIG 202.SDR 08FDEA02674Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 RG HAS PUNCTURES AND BALL BEARINGS STUCK IN THE UPPER SURFACE. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02673Floorboard · damagedMAIN CARGO DECK FLOOR PANEL 232 PF HAS BALL BEARINGS STUCK IN THE TOP SURFACE AND PUNCTURES FROM FRAME 19 TO 22; RBL 57 TO RBL 77. REPAIRED DAMAGED AREAS PER A300-600 SRM 53-10-20; FIG 201.SDR 08FDEA02672Floorboard · damagedMAIN CABIN FLOOR PANEL 231 SG UPPER SURFACE HAS NUMEROUS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02671Floorboard · damagedMAIN CABIN FLOOR PANEL 231 TG UPPER SURFACE HAS NUMEROUS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02670Floorboard · damagedMAIN CABIN FLOOR PANEL 231 UG UPPER SURFACE HAS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02669Floorboard · damagedMAIN CABIN FLOOR PANEL 231 GG UPPER SURFACE HAS PUNCTURES FROM BALL BEARINGS AND THE EDGING COMPOUND IS MISSING FROM THE INBD CORNER. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02668Floorboard · damagedMAIN CABIN FLOOR PANEL 231 JG UPPER SURFACE HAS NUMEROUS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02667Floorboard · damagedMAIN CABIN FLOOR PANEL 231 FG HAS NUMEROUS PUNCTURES IN THE UPPER SURFACE FROM BALL BEARINGS. REPAIRED DAMAGED AREAS IAW A300-600 SRM 53-10-20; FIG 201.SDR 08FDEA02666Floorboard · damagedMAIN CABIN FLOOR PANEL 231 PG UPPER SURFACE HAS NUMEROUS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02665Floorboard · damagedMAIN CABIN FLOOR PANEL 231 WG UPPER SURFACE HAS NUMEROUS PUNCTURES FROM BALL BEARINGS. REPAIRED IAW A300-600 SRM 53-10-20; FIG 201.SDR 08FDEA02664Floorboard · damagedMAIN CABIN FLOOR PANEL 231 HG UPPER SURFACE HAS NUMEROUS PUNCTURES FROM BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 202.SDR 08FDEA02663Floorboard · damagedMAIN CABIN FLOOR PANEL 231 GG IS PUNCTURED ON THE UPPER SURFACE IN MANY AREAS BY BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 SRM 53-10-20; FIG 201.SDR 08FDEA02662Floorboard · damagedMAIN CABIN FLOOR PANEL 231 FG UPPER SURFACE IS PUNCTURED IN MANY AREAS BY BALL BEARINGS. REPAIRED DAMAGED FLOOR PANEL IN REF TO A300-600 MSRM 53-10-20; FIG 202.
Back to JASC 5321