JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA010335Floorboard · corrodedCORROSION AND GOUGES ON FLOORBOARD A9 STATION 908. REMOVED HAT CHANNELS, FABRICATED NEW FLOOR PANEL SKIN AND HAT CHANNELS. INSTALLED HAT CHANNELS AND FLOORBOARD INSULATION BAGS.SDR MWEA010320Floorboard · corrodedCABIN FLOORBOARD F1 HAD LITE CORROSION ON FORWARD END. REMOVED SKIN, FABRICATED AND INSTALLED NEW SKIN.SDR MWEA010319Floorboard · crackedCABIN FLOORBOARD B-4 HAD ONE CRACKED SCREW HOLE. CUT OUT DAMAGE, FABRICATED, LOCATED AND INSTALLED REPAIR DOUBLERS.SDR MWEA010306Floorboard · crackedFORWARD CABIN FLOORBOARD E1 HAD CRACK PROPAGATING FROM MIDDLE OUTBOARD HOLE. REMOVED FLOORBOARD, FABRICATED DOUBLER, FILLER, LOCATED, INSTALLED AND REINSTALLED FLOORBOARD.SDR AU010227Screw · unapproved part(AUS) INCORRECT LENGTH SCREW FITTED TO PILOTS FLOOR PANEL. LONG SCREW CUT A GROOVE IN PIPE.SDR MWEA010300Floor Panel · corrodedPANEL F6 HAS MANY AREAS OF CORROSION, DENTS AND CRACKED HOLES. REMOVED FLOORBOARD SKIN, FABRICATED FLOOR PANEL, AND HAT CHANNELS. INSTALLED CHAFE STRIPS AND HAT CHANNELS.SDR UPS01835408Floorboard · corrodedINSPECTION TYPE:C2 FLOORBOARD STA 1040 BETWEEN RAILS E & F CORRODED REPAIRED AREA IAW DC8 SRM 53-2-3SDR DHL2001806590Floor Panel · crackedC-CHECK - COCKPIT - 682 FLOOR PANEL SUPPORT ANGLES LWR EDGE CRACKED 1/2 INCH AT STA -12.000. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG 1B. FABRICATED REINFORCING ANGLE IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED REINFORCING ANSDR DHL2001806543Floor Panel · crackedC-CHECKED - FLIGHT COMPARTMENT #676B FLOOR PANEL SKIN CRACKED. PERFORMED STOP HOLE IAW SRM 53-2-3 FIG 10. FABRICATED DOUBLER IAW SRM 53-2-3 FIG 10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER USING NEW FASTNERS IAW SRM 51-1-21 PAGE 1. SDR DHL2001806542Floor Panel · crackedC-CHECK - FLIGHT COMPARTMENT 676C FLOOR PANEL SKIN CRACKED. PERFORMED STOP HOLE IAW SRM 53-2-3 FIG 10. FABRICATED DOUBLER IAW SRM 53-2-3 FIG 10, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER IAW SRM 53-2-3 FIG 10. STATUS-CLOSED.SDR DHL2001806527Floor Panel · crackedC-CHECK - FLIGHT COMPARTMENT 683 FLOOR PANEL SKIN CRACKED. PERFORMED STOP HOLE IAW SRM 53-2-3 FIG 10. FABRICATED DOUBLER IAW SRM 53-2-3 FIG. 10. TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER IAW SRM 53-2-3 FIG 10. STATUS-CLOSED.SDR AT0100111Floorboard · corrodedFOUND FLOORBOARD CORRODED BEYOND LIMITS AT BS 129 RBL 17-42. FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-70-04 AND 51-10-03.SDR DHL2001741517Floorboard · corrodedCORROSION ON FLOORBOARDS AND FLOOR SUPPORT STRUCTURE FROM FS STA 303 TO FS 344 AND FROM RBL 16 TO RBL 55 (UNDER FWD LAV). REMOVED CORROSION AS PER B727 SRM 51-10-6 MATERIAL LOSS .030 FOUND OUT OF LIMITS AS PER B727 SRM 53-30-1. REPLACED FLOORBOARDS SUPPORT PSDR DHL2001741502Floorboard · corrodedCORROSION ON AND FLOOR SUPPORT STRUCTURE FROM FS STA 303 TO FS 344 AND FROM RBL 16 TO RBL 55 (UNDER FWD LAV). REMOVED CORROSION AS PER B727 SRM 51-10-6 MATERIAL LOSS .030 FOUND OUT OF LIMITS AS PER B727 SRM 53-30-01. REPLACED FLOORBOARDS SUPPORT PO 8B12244 LSDR DKAA01008Floor Panel · corrodedFOUND COCKPIT FLOOR CORRODED, RIGHT SIDE FS 148-218. REPAIRED PER DER DRAWING NR 53-01010-1, DATED 01/16/2001. AIRCRAFT RETURNED TO SERVICE. (M)SDR AT0100109Floorboard · corrodedFOUND FLOORBOARD 4698 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 53-05, 51-10-02, 51-10-04, AND 51-20.SDR AT0100107Floor Panel · corrodedFOUND CABIN FLOORPANEL NR 4699 CORRODED. REPLACED FLOORPANEL SKIN IAW DC9 SRM 53-21 FIG 2D, 51-10-02, 51-10-0351-10-04, 51-20-01, AND 51-30-02.SDR DHL2001806519Floor Panel · brokenC-CHECK - AFT CARGO COMPARTMENT - LOWER RT FLOOR PANEL BROKEN 2 INCH. REMOVED DAMAGED FLOOR PANEL IAW SRM 51-3-0. FABRICATED NEW FLOOR PANEL IAW SRM 53-2-3 FIG 10. CLEANED, TREATED, AND PRIMED IAW SRM 51-1-8B PAGE 12-13. INSTALLED FLOOR PANEL IAW SRM 51-3-SDR MWEA010223Floor Panel · misdrilledCABIN FLOOR PANEL F3 HAS SIX MISDRILLED FASTENER HOLES. REMOVED, FABRICATED AND INSTALLED FLOOR PANEL SKIN.SDR MWEA010222Floor Panel · crackedCABIN FLOOR PANEL E5, SKIN IS CRACKED BY FASTENER FOR CHANNEL AT ONE END. REMOVED, FABRICATED AND INSTALLED PANEL SKIN.SDR MWEA010221Floor Panel · misdrilledCABIN FLOOR PANEL E3 HAS MISDRILLED HOLES ALONG ONE SIDE. REMOVED, FABRICATED AND INSTALLED PANEL SKIN.SDR MALA010310Floorboard · corrodedFOUND DURING C-CHECK, IN NASHVILLE,TN. FLOORBOARD FLANGE AT FS 272 FOR FLOOR PANEL 122CZ HAS CORROSION. MAINTENANCE BLENDED OUT CORROSION, NEGLIGIBLE MATERIAL REMOVED. MATERIAL REMAINT WITHIN LIMITS, ALODINED BARE METAL, PRIMED AND PAINTED AREA IAW SRM 51-20SDR MWEA010198Floor Panel · delaminatedFROM E&E COMPARTMENT, FLOOR ABOVE SNAPS SHARPLY WHEN FLOOR ABOVE IS WALKED ON, AT AIRCRAFT AND APPROXIMATELY FS 200. LOCATED AND INSTALLED NEW PANEL.SDR RRXA010684Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE GALLEY FLOOR PANEL AT TOP SURFACE PANEL #329, DAMAGE EXCEEDED LIMITATIONS IAAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DCSDR EIA2001082Floor Panel · crackedMZJ-EAC - FOUND FLOOR PANEL NR 33 FROM FS 503-775 LBL 38 TO LBL 45 DOUBLER AND SEVERAL FASTENERS CRACKED. REPAIRED FLOOR PANEL PER ECRA 933-53-091-2. (M)SDR RRXA010674Floor Panel · misrepairedDURING A MAINTENANCE VISIT FOUND AN IMPROPER REPAIR TO THE MAIN CARGO FLOOR PANEL AT STA 80 TO 340E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND DC-9 SRM SDR MALA010306Floorboard · corrodedFOUND DURING C-CHECK FROM, IN NASHVILLE, TN. FLOORBOARD FLANGE AT STA 231.0 HAS CORROSION. REFER TO W/O 19430, TASK 2543. MAINTENANCE BLENDED OUT CORROSION IAW SRM 51-70-40. REMAINING MATERIAL OUT OF LIMITS, REMOVED SEVERAL CORRODED RIVETS, ALODINED BARE METSDR RRXA010510Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE EDGES OF THE FLOOR PANEL CAPT'S SIDE PANEL #676D, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA010509Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL #661 AND CRACKED SCREW HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IASDR RRXA010508Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND PERIMETER TOP & BOTTOM EDGES OF CENTER COCKPIT FLOOR PANEL #677 CHAFF STRIP BROKEN, ELONGATED HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IASDR CALA0100143Floorboard · tornINSPECTION FOUND MAIN CABIN O/B FLOORBOARD TORN AT FS 140 - 200. THE FLOORBOARD WAS REMOVED AND A NEW FLOORBOARD WAS INSTALLED IAW ECRA 5100-01844.SDR AT0100092Floor Panel · corrodedFOUND FORWARD CABIN FLOOR PANEL BS 155 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 51-10-02, 51-10-03, 51-10-04, 53-21 FIG 20 AND DC9 MM 53-20-01.SDR AT0100091Floor Panel · corrodedFOUND FLOOR PANEL 47 CORRODED BEYOND LIMITS. REPLACED FLOOR PANEL IAW DC9 SRM 53-21 AND 51-20-02.SDR MWEA010152Floor Panel · crackedFLOOR PANEL E-6 IS CRACKED ON AFT OUTBOARD CORNER. FABRICATED AND INSTALLED DOUBLER.SDR AWXA0001326Web · crackedFLOOR WEB CRACKED FS 180 WL 207 LBL 26. REMOVED FLOOR WEB IAW SRM 51-40-02; FABED REPLACEMENT WEB IAW DWG 65-45833; INSTALLED REPLACEMENT WEB IAW 51-40-02.SDR AWXA0001324Web · crackedFLOOR WEB CRACKED FS 180 WL 207 RBL 26. REMOVED FLOOR WEB IAW SRM 51-40-02; FABED REPLACEMENT WEB IAW DWG 65-45833; INSTALLED REPLACEMENT WEB IAW SRM 51-40-02.SDR RRXA10864Pressure Panel · crackedDURING A MAINTENANCE VISIT FOUND CORROSION AND CRACK DAMAGE TO COCKPIT FLOOR PANEL 682A, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4.SDR RRXA10859Floor Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO FLOOR PANEL BETWEEN TRACKS 1 & 2 AT STA. 480-560, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAWSDR RRXA10856Floor Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO UPPER CARGO COMPT. FLOOR PANEL AT STA. 580-590 X=45-55, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0 ANDSDR RRXA10869Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL #678 UNDER F/E TABLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4. (CSDR RRXA10867Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO COCKPIT FLOOR PANEL #676F, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4. (CORROSIOSDR RRXA10866Panel · corrodedDURING A MAINTENACE VISIT FOUND CORROSION DAMAGE TO R/H COCKPIT FLOOR PANEL #676A, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4. (CORROSDR RRXA10865Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CO-PILOTS FLOOR PANEL #676B AROUND PERIMETER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA10871Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO GALLEY FLOOR TOP SURFACE PANEL #328 AT STA. 55-80 AND X+32, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR RRXA10855Panel · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO CENTER FLOOR PANEL BEHIND CENTER PADISTAL EDGE BENT & CRACKED AT SCREW HOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED RESDR RRXA10872Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO GALLEY FLOOR TOP SURFACE PANEL #327 AT STA. 55-80 AND X+16, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR RRXA10817Plate · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO D-PIT KICK PLATE AT D-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O.#01-006 WITH APPROVEDSDR TWAA0102309Floor Panel · corrodedDURING CHECK-C MAINT FOUND FLOOR WEB AT LONGERON 18R, STA 484 TO 503, WAS CORRODED. REMOVED CORROSION PER SRM 53-10-3. INSTALLED REPAIR PER SRM 53-01, PAGE 9, WITH 5/32 AD RIVETS.SDR TWAA0102308Floor Panel · corrodedDURING CHECK-C MAINT FOUND LONGERON 18R, STA 560 TO 579, THE FLOOR WEB HAD CORROSION. CUT OUT CORROSION. INSTALLED DOUBLER PER SRM 53-01, PAGE 9.SDR MWEA010128Floorboard · damagedHOLE IN SUBFLOOR, RIGHT SIDE JUST AFT OF STATION 945, OUTBOARD OF NR 4 SEAT TRACK. FABRICATED AND INSTALLED DOUBLERS.
Back to JASC 5321