JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR L1GA200000188Floorboard · crackedCORNER OF FLOOR PANEL CRACKED APPROX 1.5 INCH AT FS 579 TO 613 BL 24R TO 44R. INSTALLED REPAIR DOUBLER.SDR SWAA001436Floor Panel · corrodedDURING SCHEDULED D-CHECK, FOUND COCKPIT FLOOR UPPER SURFACE CORRODED, BS 211 RBL 11 TO RBL 17. REPAIRED FLOOR SKIN PER SRM.SDR EIA2000227Panel · crackedFOUND BS 1240 CANTED BULKHEAD LBL 93 AND RBL 75-98 BELOW FLOOR CLOSURE WEB PANELS CRACKED. BOTH SIDES OF DEFECTIVE CLOSURE PANELS REPLACED PER BOEING SB 747-53-2329. (M)SDR DHL200072101CFloor Panel · brokenFWD CARGO COMPT FLOOR PANEL 3.5 X 3.5 REPAIR HAS BROKEN AND SHARP EDGES AT FS 660. REMOVED EXISTING REPAIR PER SRM 57-30-2. CUT OUT DAMAGED FLOOR PANEL 4 X 4.5 INCH AND INSTALLED FLUSH DOUBLER REPAIR PER SRM 51-40-2.SDR RRXA003063Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE FWD END OF THE FLOOR PANEL JOINT SUPPORT IN THE MAIN CABIN AT STA Y=580 AND X-36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED RSDR RRXA003778Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE "B" PIT FLOOR PANEL AT STA 340-440 AND L27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PSDR F3LA00158Floor Panel · corrodedDEN - DURING C-2 CHECK, INSPECTION REPORTED CORROSION AT BOTTOM OUTBOARD FORWARD CORNER OF NR 2 GALLEY. MAINTENANCE REPLACED FLOOR PANEL PER SRM 51-10-2. (X)SDR RRXA11054Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER PIT JAM AFT OMNI ROLER FITTING AT STA 1761 AND X=-70, DAMAGE EXCEEDED LIMITATIONS IAW DC-10 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-21-01. RECEIVED PART AND INSTASDR CALA0001142Floor Panel · corrodedINSPECTION FOUND FORWARD ENTRY FLOOR PANEL CORRODED ON SURFACE AT STA 196, LBL 14. THE CORRODED AREA WAS REMOVED AND FILLER AND DOUBLER WERE INSTALLED IAW SRM 53-01, FIGURE 2, 53-14-1, FIGURE 1 & 2, AND 51-30-02.SDR MWEA00555Floorboard · damagedFLOORBOARD D-1 HAS EDGE LIP DAMAGE LOCATED AT STATION 237. FABRICATED AND INSTALLED DOUBLER.SDR MWEA00584Floorboard · gougedFLOORBOARD C-8 TOP SURFACE EDGE-LIP HAS 3 AREAS WITH GOUGE/MISDRILL DAMAGE AT STATION 746. REINFORCED FIBERGLASS REPAIR INSTALLED.SDR MWEA00585Floorboard · puncturedFLOORBOARD C-3 HAS SURFACE PUNCTURE/IMPACT DAMAGE AT STATION 400 AND 410. REINFORCED FIBERGLASS REPAIR INSTALLED.SDR MWEA00586Floorboard · chafedFLOORBOARD D-6 HAS SURFACE CHAFE DAMAGE AT STATION 737. REINFORCED FIBERGLASS REPAIR INSTALLED.SDR RRXA003779Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE "D" PIT FLOOR PANEL AT STA 988-1066 AND L33R TO L33L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAAW DC-8SDR RRXA003774Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SUB FLOOR PANEL BETWEEN STA 80 TO 220 BL 0 TO LBL 25 Z=-2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SDR DHL200070912CFloor Panel · corrodedMAIN CARGO COMPT FLOOR PANEL 1B CORRODED ON TOP AREA. REMOVED UPPER SKIN AND CORROSION FROM FLOOR PANEL PER SRM 51-10-6. MATERAL LOSS WITHIN LIMITS PER SRM 53-30-1. TREATED AND PRIMED PER SRM 51-10-2. FABRICATED AND INSTALLED NEW UPPER SKIN AT FLOOR PANEL SDR MWEA00554Floorboard · chafedFLOORBOARD D-6 TOP SURFACE EDGE LIP HAS CHAFE DAMAGE AT STATION 746. MAINTENANCE REPAIRED DAMAGE BY REINFORCED FIBERGLASS REPAIR.SDR CALA0001066Floorboard · crackedINSPECTION FOUND LEFT O/B CABIN FLOOR PANEL CRACKED AT EDGES, STA 541 - 617. THE CRACKED AREA WAS CUT OUT IAW SRM 53-01, FIGURE 4B. A DOUBLER REPAIR WAS INSTALLED IAW SRM 53-01, FIGURE 4B, 51-10-3, AND 51-30-2.SDR CALA0001057Floorboard · corrodedINSPECTION FOUND FLOOR SKIN CORRODED AT FS 160, RBL 10. TWO FLOOR SUPPORTS WERE REMOVED TO FACILITATE MAINTENANCE. FILLER AND DOUBLER WERE INSTALLED IAW SRM 53-01 AND 51-10-04. THE FLOOR SUPPORTS WERE REINSTALLED IAW SRM 51-10-04.SDR RRXA002859Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT FS 41 - 58 AND LBL 31 - LBL 44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSISDR RRXA002856Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LOWER SIDE OF THE FLOOR WEB AT FS 25 - 55 AND LBL 57, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (SDR RRXA002851Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE FLOOR PLANK AT FS 1020 - 1023 AND RBL 17, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (SDR RRXA002840Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE FLOOR PLANK AT FS 1260 AND LBL 17, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR QXEA0001955Floorboard · burnedPDX- RIGHT HAND AIR CYCLE MACHINE COMPARTMENT, COCKPIT FLOOR UNDER CO-PILOTS SIDE CONSOLE HAS A BURN HOLE. REPAIRED IAW FOKKER SRM 53-02-02.SDR AALA20001147Doubler · corrodedTUL - INBOARD OF RIGHT GALLEY DOOR FLOOR SUPPORT, SUB-FLOOR DOUBLER ERODED/CORRODED, 6 INCHES BY 5 INCHES, BEYOND LIMITS. INSTALLED DOUBLER, 7075T6, 0.025 INCH, PER SRM 53-01, FIG 4, SHEET 3. (X)SDR MWEA00537Floorboard · crackedMKE - LEFT FLOORBOARD IN CABIN FROM STATION 465-579 HAS 2 TORN FASTENER HOLES AT FORWARD END AND A CRACK ON OUTBOARD SIDE 20 INCHES AFT OF FORWARD END. FABRICATED AND INSTALLED REPAIR DOUBLER. (M)SDR DHL200070910CPanel · corrodedUPPER FUSELAGE TOILET FLOOR PANEL IS DAMAGED AND HAS CORROSION. REMOVED FLOOR PANEL PER SRM 51-30-2. FABRICATED NEW FLOOR PANEL PER SRM 53-10-1. TREATED AND PRIMED PER SRM 51-10-2. INSTALLED NEW SUB FLOOR PER SRM 51-30-2.SDR CALA0001002Floorboard · corrodedINSPECTION FOUND RT FLOOR WEB OB OF OUTBOARD SEAT TRACK. CORRODED AT FS 900. THE CORRODED AREA WAS CUT OUT IAW SRM 53-01. A REPAIR WAS INSTALLED IAW SRM 53-01, FIGURE 2, 51-30-2, AND 51-10-3.SDR MWEA00538Floorboard · crackedMKE - FOUND CABIN FLOORBOARD BETWEEN SEAT TRACKS NR 1 AND NR 2 AT STATION 680 IS CRACKED IN NUMEROUS PLACES. FABRICATED AND INSTALLED NEW FLOORBOARD AREA. (M)SDR AALA20001126Floor Panel · corrodedTUL - FLOOR WEB CORRODED AT FORWARD ENTRY OF CABIN, STA 160 - STA 218. CUT OUT DAMAGE AND INSTALLED DOUBLER PER AARD 53-01 AND SRM 53-01, FIG 4. (X)SDR AT0000345Floor Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LEVEL 2 CORROSION ON CABIN FLOOR PANEL #97. CORRECTIVE ACTION: REMOVED AND REPLACED SKIN ON FLOOR PANEL #97 IAW SERVICE ORDER 151063 AND TRAVLER T-5SDR RRXA003414Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AT FWD LAV AREA BETWEEN STA'S 35.000 AND 55.000 AND X-44 AND -66, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-20-01 SDR DHL2000706002Floorboard · damagedFLOOR PANEL DAMAGED AT FWD LEFT CORNER AT BS 360 PANEL FROM RBL 24.0 TO 48.0. REMOVED FLOORBOARD, FABRICATED DOUBLERS PER SRM 53-20-1. ALODINED AND PRIMED PER SRM 53-20-1. INSTALLED FLOOR PANEL PER SRM 51-30-2.SDR MWEA00521Floor Panel · crackedMKE - FLOOR PANEL ABOVE CENTER FUEL TANK ACCESS IS CRACKED AT FORWARD END CRACK. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER. (X)SDR DHL200080161CFloorboard · crackedAT C CK; MAIN CARGO COMPARTMENT FLOOR CRACKED 2 INCHES AT STA. 165.0. MADE CIRCULAR CUT ON DAMAGED AREA IAW SRM 53-2-3 PAGE 39-40, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 53-2-3 PAGE 39-40. REF: N/R 2171.SDR DHL200080174CFloorboard · crackedAT C CHECK; MAIN CARGO COMPARTMENT FLOORBOARD CRACKED 2 INCHES AT STA. 165.0. MADE CIRCULAR CUT ON DAMAGED AREA IAW SRM 53-2-3 PAGE 39-40, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PAGE 1-2, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 53-2-3 PSDR DHL200080140CFloorboard · brokenAT C CK; MAIN CARGO COMPARTMENT FLOOR BROKEN 1 INCH AT STA. 1570.00, BL 43. FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-3 PAGE 1. REF: N/R 1462.SDR DHL200080162CFloorboard · crackedAT C CK; MAIN CARGO COMPARTMENT FLOOR CRACKED 1 INCH AT STA. 62.00 BL 19LT. CUTOUT DAMAGED AREA IAW SRM 53-2-3 PAGE 1, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-3 PAGE 1. REF: N/R 1468.SDR DHL200080172CFloorboard · crackedAT C CK; MAIN CARGO COMPARTMENT FLOORBOARD CRACKED 1 INCH AT STA. 62.00 BL 19 LT. CUTOUT DAMAGED AREA IAW SRM 53-2-3 PAGE 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PAGE 1-2, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 53-2-3, PAGE 1. REF:N/RSDR DHL200080139CFloorboard · crackedAT C CK; MAIN CARGO COMPARTMENT FLOOR CRACKED AT STA. 1680.00, BL-43R. PERFORMED STOP DRILL IAW SRM 53-2-3 PAGE 1, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-3 PAGE 1. REF: N/R 1459.SDR DHL200080129CFloor Support · crackedAT C CK; MAIN CARGO COMPARTMENT FLOOR SUPPORT CRACKED 1/2 INCH AT STA. 500.0 BL 38 LT. PERFORMED STOP DRILL IAW SRM 53-2-0 PAGE 2B, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0, PAGE 2B. REF: N/R 2154.SDR MALA000406Floorboard · corrodedFOUND DURING C-CHECK, WEB CORRODED AT STA 290 UNDER FLOOR PANEL 121CZ. MAINTENANCE REMOVED CORROSION, CHECK LIMITS BLENDED AND ROUTED OUT CORROSION IAW SRM 51-70-40, REMAINING MATERIAL IS OUT OF LIMITS PER SRM 53-70-30. REPAIRED WEB AT FS 290 UNDER FLOOR PANSDR 20000710SH021Floor Panel · crackedDECK CRACKED.SDR TWAA0009608Floorboard · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON CABIN FLOOR PANEL SUPPORT AT STA 200, BL 0 TO RBL 50. REMOVED CORROSION PER SPM 6-80-1. REPLACED SUPPORT EXTRUSION PER DWG 5930545 AND SPM 6-70-01. TREATED PER SRM 51-10-3.SDR LR7A00110Floorboard · corrodedDURING SCHEDULED C2 INSPECTION NR 26971 ACCOMPLISHMENT FOUND FS 245 - 417 NR 2 RT FLOOR PANEL CORRODED. REPAIRED PER SRM SMP 583-53-40-30.SDR LR7A00109Floorboard · corrodedDURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53121, FOUND FS 577-737E NR 4 LT FLOOR PANEL CORRODED. REPAIRED PER SRM SMP 583-53-40-30.SDR LR7A0077Floorboard · corrodedDURING SCHEDULED C2 INSPECTION NR 26473 ACCOMPLISHMENT, FOUND FS 245E-345E NR 1 RT FLOOR PANEL CORRODED RBL 15.5 - 51.5. FABRICATED AND REPLACED FLOOR PANEL PER SRM SMP 583-51-60.SDR LR7A0075Floorboard · corrodedDURING SCHEDULED C2 INSPECTION NR 26473 ACCOMPLISHMENT, FOUND FS 245E-345E NR 1 LT FLOOR PANEL CORRODED AND FASTENERS PULLING THROUGH LBL 15.5 - LBL 51.5. FABRICATED AND REPLACED FLOOR PANEL PER SRM SMP 583-51-60.SDR LR7A0066Floorboard · corrodedDURING SCHEDULED C2 INSPECTION NR 26473 ACCOMPLISHMENT, FOUND FS 245E-345E NR 1 CTR FLOORBOARD CORRODED LBL 15.5 - RBL 15.5. FABRICATED AND REPLACED FLOOR PANEL PER SRM SMP 583-51-60. NR 26564.SDR RRXA002967Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 1145 AND X-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE REC
Back to JASC 5321