JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA00201Floorboard · crackedCABIN FLOORBOARD B-1 HAS A FASTENER HOLE THAT IS CRACKED AT FLOORBOARD CORNER. FABRICATED AND INSTALLED DOUBLER.SDR RRXA002167Track · wornDURING A MAINTENANCE VISIT FOUND A WORN #6 TRACK AT STA 1300-1297 RT. AND RBL 45", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK IAW DC-8SDR RRXA001724Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6SDR RRXA001718Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 SDR RRXA001715Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C6-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001712Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C5-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DASDR RRXA001695Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED SDR RRXA001689Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES DRILLED IN FLOOR PANEL C2-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 SDR RRXA001684Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-SDR RRXA001683Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110SDR RRXA001682Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-SDR RRXA001681Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110-SDR RRXA001680Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110SDR RRXA001675Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 81SDR RRXA001663Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C29-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001646Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001645Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND A LARGE HOLE 9 INCHES FROM EDGE, 5 INCHES FROM OUTBOARD EDGE C12-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR PER E.O. 99-236 WITH APPROVED 8110SDR RRXA001644Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-0SDR RRXA001643Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DASDR RRXA001640Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110-3 DASDR RRXA001639Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C14-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-SDR RRXA001638Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DASDR RRXA001637Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DSDR RRXA000934Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C6-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA000931Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C1-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA000929Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C15-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-SDR RRXA000894Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C9 TO R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000841Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C15-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA000837Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C12-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW EO NR 99-236 WITH APPROVED 811SDR RRXA000829Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PLANK (C1-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8, FILLED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DSDR RRXA001723Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES ON FLOOR PANEL C12-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001719Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES THROUGHOUT FLOOR PANEL C12-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-SDR RRXA001714Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6SDR RRXA001713Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C4-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-SDR RRXA001706Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-SDR RRXA001694Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-SDR RRXA001679Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 811SDR RRXA001661Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C1-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY FILL WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001648Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C9-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8SDR RRXA001635Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8SDR RRXA001634Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8SDR RRXA000930Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C5-R13, DAMAGED EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA000926Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C12-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. NR 99-236 WITH APPROVED 8110-3 DATE 3-6SDR RRXA000845Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C8-R8), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED ALL DISCREPANT HOLES BY WELDING IAW EO NR 99-236 WITH APPROVED 8110-3 DATED 3-SDR RRXA000842Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C3-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DATED 3-6-00SDR RRXA000836Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C1-R7) 12 INCHES FROM EDGE FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW EO NRSDR RRXA001722Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL O1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING IAW E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001721Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGH FLOOR PANEL, LARGE HOLE WITH CRACK AT ABOUT CENTER OF FLOOR PANEL AND LARGE DENT WITH CRACK ABOUT 2 INCHES FROM EDGE C2-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATEDSDR RRXA001717Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001711Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C12-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 399-236 WITH APPROVED 8110-3 DATED 3-6-00.
Back to JASC 5321