SDR MWEA00201Floorboard · crackedCABIN FLOORBOARD B-1 HAS A FASTENER HOLE THAT IS CRACKED AT FLOORBOARD CORNER. FABRICATED AND INSTALLED DOUBLER.Mar 31, 2000 · N900ME · Doug DC915SDR RRXA002167Track · wornDURING A MAINTENANCE VISIT FOUND A WORN #6 TRACK AT STA 1300-1297 RT. AND RBL 45", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK IAW DC-8Mar 28, 2000 · N961R · Doug DC873FSDR RRXA001724Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001718Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001715Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C6-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001712Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C5-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862SDR RRXA001695Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001689Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES DRILLED IN FLOOR PANEL C2-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001684Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001683Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001682Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001681Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001680Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001675Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 81Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001663Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C29-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001646Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001645Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND A LARGE HOLE 9 INCHES FROM EDGE, 5 INCHES FROM OUTBOARD EDGE C12-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR PER E.O. 99-236 WITH APPROVED 8110Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001644Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-0Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001643Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862SDR RRXA001640Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862SDR RRXA001639Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C14-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-Mar 28, 2000 · N994CF · Doug DC862SDR RRXA001638Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DAMar 28, 2000 · N994CF · Doug DC862SDR RRXA001637Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DMar 28, 2000 · N994CF · Doug DC862SDR RRXA000934Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C6-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA000931Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C1-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA000929Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C15-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 28, 2000 · N994CF · Doug DC862SDR RRXA000894Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C9 TO R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA000841Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C15-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 28, 2000 · N994CF · Doug DC862SDR RRXA000837Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C12-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW EO NR 99-236 WITH APPROVED 811Mar 28, 2000 · N994CF · Doug DC862SDR RRXA000829Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PLANK (C1-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8, FILLED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DMar 28, 2000 · N994CF · Doug DC862SDR RRXA001723Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES ON FLOOR PANEL C12-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001719Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES THROUGHOUT FLOOR PANEL C12-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001714Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001713Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C4-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001706Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001694Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001679Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 811Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001661Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C1-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY FILL WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001648Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C9-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001635Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8Mar 27, 2000 · N994CF · Doug DC862SDR RRXA001634Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES IAW E.O. 99-236 WITH APPROVED 8Mar 27, 2000 · N994CF · Doug DC862SDR RRXA000930Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C5-R13, DAMAGED EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 27, 2000 · N994CF · Doug DC862SDR RRXA000926Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C12-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. NR 99-236 WITH APPROVED 8110-3 DATE 3-6Mar 27, 2000 · N994CF · Doug DC862SDR RRXA000845Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C8-R8), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED ALL DISCREPANT HOLES BY WELDING IAW EO NR 99-236 WITH APPROVED 8110-3 DATED 3-Mar 27, 2000 · N994CF · Doug DC862SDR RRXA000842Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C3-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 8110-3 DATED 3-6-00Mar 27, 2000 · N994CF · Doug DC862SDR RRXA000836Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C1-R7) 12 INCHES FROM EDGE FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING IAW EO NRMar 27, 2000 · N994CF · Doug DC862SDR RRXA001722Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL O1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING IAW E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 26, 2000 · N994CF · Doug DC862SDR RRXA001721Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGH FLOOR PANEL, LARGE HOLE WITH CRACK AT ABOUT CENTER OF FLOOR PANEL AND LARGE DENT WITH CRACK ABOUT 2 INCHES FROM EDGE C2-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATEDMar 26, 2000 · N994CF · Doug DC862SDR RRXA001717Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 26, 2000 · N994CF · Doug DC862SDR RRXA001711Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C12-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 399-236 WITH APPROVED 8110-3 DATED 3-6-00.Mar 26, 2000 · N994CF · Doug DC862
Back to JASC 5321