JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA001710Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O.99-236 WITH APPROVED 8110-3 DATED 3-6-SDR RRXA001708Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C8-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-SDR RRXA001678Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL FLOOR PANEL DISCREPANT HOLES PER E.O. 99-236 WITH ASDR RRXA001677Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL FLOOR PANEL DISCREPANT HOLES PER E.O. 99-236 WITH APSDR RRXA001662Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C13-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IN FLOOR PLANKS PER WELDING IAW E.O. 99-236 WITH APPROVED 8110-3 DATED SDR RRXA000927Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBOARD C14-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED FLOOR PLANK, FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APSDR RRXA000843Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C9-R6), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8, FILLED ALL DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 81SDR RRXA000835Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C9-R3), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES BY FILLET WELDING IAW EO NR 99-236 WITH APPROVED 8110-3 DATESDR RRXA001720Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS HOLES IN FLOOR PANEL C9-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001716Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT C1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY FILLET WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001709Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND WORN DRILLED HOLE AREA ON FLOOR PANEL ALSO NUMEROUS DRILLED HOLES ON FLOOR PANEL C12-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES BY WELDING PSDR RRXA001707Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND DRILLED HOLES CLUSTERED TOGETHER C14-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA001676Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON ALL DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 811SDR RRXA001642Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANAT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 SDR RRXA001641Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DASDR RRXA001636Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR ON DISCREPANT HOLES PER E.O. 99-236 WITH APPROVED 8110-3 DSDR RRXA000932Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED DISCREPANT HOLES BY WELDING PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.SDR RRXA000844Floorboard · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C2-R3), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8, FILLED ALL DISCREPANT HOLES BY WELDING PER EO NR 99-236 WITH APPROVED 81SDR RRXA003405Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR BOARD AT STA'S 55 TO 100 AND X60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-7-3 AND DWG 5759394.SDR QXEA0000961Floorboard · corrodedPDX - CORROSION ON FLOOR PANEL, BENEATH FIRST OFFICERS SEAT. REPAIRED IAW FOKKER SRM 53-11-05, PAGE 6, FIGURE 2 AND SRM 53-01-01, PAGE 6, PARAGRAPH 4B (1).SDR RRXA002149Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LEFT WHEEL WELL PRESSURE FLOOR AT FS 857-879 AND LBL 58-65, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW XEA-X8-53-874.SDR F3LA00026Floorboard · corrodedDEN - DURING C-7 CHECK INSPECTION, FOUND CORROSION ON FLOORBOARD ATTACH ANGLE STATION 960 TO 986.5, STRINGER 17R. MAINTENANCE REMOVED CORROSION, TREATED, PRIMED AND PAINTED FLOORBOARD ATTACH ANGLE PER SRM 51-10-2 AND MM 25-25-0. (M)SDR MWEA00141Floorboard · corrodedFORWARD EDGE OF FLOORBOARD AT STATION 237 BETWEEN NR 3 AND NR 4 SEAT TRACKS ARE MODERATLY CORRODED. FABRICATED AND INSTALLED FLOORBOARD.SDR MWEA00160Floorboard · corrodedFORWARD EDGE OF FLOORBOARD AT STATION 237 BETWEEN NR 4 SEAT TRACK AND SIDEWALL MODERATELY CORRODED. FABRICATED AND INSTALLED DOUBLER.SDR RRXA000584Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBOARD AT STA 1020 TO 1300 AND LONGERON BL-0 AND BL-R 10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED HEAVY EXFOLIATION CORROSION, ALODINED, PRIMED AREA AND REPLACED IAW DC-8 SRM 51-1-8. (CORROSSDR GAIA00108Floorboard · damagedDURING POST FLIGHT INSPECTION, FOUND HOLES PUNCHED IN THE FLOORBOARDS AT THE FOLLOWING STATIONS 480 X=12L, 427 X=38L AND 605 X=12R. THE FLOORBOARDS WERE REPAIRED IAW THE DC-9 SRM, THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR RRXA002163Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN 2 PLACES TO THE MAIN CABIN FLOOR PANEL AT FWD ENTRY DOOR AT FS 25-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 51-1-21, 51-1-20DSDR RRXA002162Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE DRAIN PLUG HOLE ON THE MAIN CABIN FLOOR PLANK AT BS 1200 AND RBL 10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 51-1-21, 51-1-SDR RRXA002153Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOOR PLANK AT FS 850-879 AND LBL 26-27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 53-2-3.SDR RRXA002152Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOOR PLANK AT FS 987-990 AND LBL 16-19, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 53-2-3.SDR RRXA001744Floorboard · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK IN TWO PLACES TO THE MAIN CABIN FLOOR PANEL AT FWD ENTRY DOOR AT FS 25 TO 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL ISDR RRXA001730Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOORBOARD, FS 850 TO 879 AND LBL 26 TO 27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND FILLER IAW DSDR RRXA000580Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN FLOORBOARD AT STA 280 TO 415 AND LONGERON RBL 58 TO 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED MAIN CABIN FLOORBOARD AND INSTALLESDR RRXA000579Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN FLOORBOARD AT STA 200 AND LONGERON RBL 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED, REPAIRED DOUBLER AND FILLER AND INSTALLED IAW SDR RRXA003732Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT FLOOR PANEL LT AT STA 1688 X TO +26, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4 AND 53-2-0. (CORRSDR CALA0000281Floor Panel · corrodedINSPECTION FOUND COCKPIT FLOOR SKIN CORRODED AT FS 160, LBL 6. THE CORROSION WAS REMOVED IAW SRM 53-01, FIGURE 2 AND 51-10-3. A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-01, FIGURE 2, 51-10-04, 51-30-02.SDR RRXA003432Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR SUPPORT AT STA 1240-1260 BETWEEN L34L-L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-20, 51-1-SDR RRXA000693Floorboard · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MAIN CABIN FLOOR BOARD AT STA 145 AND RBL 22, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 53-20, 51-1-20 AND 53-2-3.SDR UPS00832119Floorboard · corrodedINSPECTION TYPE: C123, FLOOR PANEL, STA 580 - 759 HAS CORROSION ON UPPER SKIN. REMOVED CORROSION, FOUND OUT OF LIMITS FROM FS 620 - 759 IAW 53-20-0 FIG 1F. REPLACE FLOOR PANEL PN 52772658-15300. DRILLED IAW 51-1-21. ALODINED & PRIMED IAW DC8 SRM 51-1-8SDR TWAA0003910Floorboard · crackedDURING OP 16 MAINT CHECK, CABIN FLOOR PANEL 11, TOP SIDE HAD CORROSION IN SEVERAL AREAS. FABRICATED NEW FLOOR PANEL USING OLD PANEL AS A TEMPLATE. USED 2024-T3, 0.063 FOR PANEL. USED 0.032, 7075-T6 FOR HAT SECTION. NAS1097AD RIVETS WERE USED PER SSRM 53-00SDR RRXA003433Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOOR PANEL AT FS 742-743 AND LBL 44-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 5SDR RRXA003431Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOOR PLANK AT FS 490-492 AND 520-522 AND LBL 28-29, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IASDR UPS00832095Floorboard · corrodedINSPECTION TYPE: C 123 MAIN CABIN FLOORBOARD AT STA 1000 TO 1300. FLOORBOARD NR 2 HAS NUMEROUS AREAS OF CORROSION. REMOVED CORROSION & FOUND TO BE OUT OF LIMITS IAW DC8 SRM 51-1-8. MATERIAL ID 7075-T6 .071 IAW DC8 SRM 53-7-2 PO 313574. FABBED DOUBLERS IASDR UPS00832084Floorboard · corrodedINSPECTION TYPE:C123 CORROSION AROUND BEAR STRAP RETAINER THROUGH FLOORBOARD AT STA 1595, RBL 35. REMOVED CORRODED SECTION OF FLOOR PANEL. LOCATED NEW FLOOR PANEL, DRILLED & COUNTERSUNK EXISTING FASTENER HOLES IAW DC8 SRM 51-1-22 & 51-3-2. FAB REPAIR SPLSDR UPS00832083Floorboard · corrodedINSPECTION TYPE: C 123 CORROSION ON FLOOR PANEL, RT FS 1560 RBL 40 AFT ACC BAY, REMOVED CORRODED FLOOR PANEL. RECEIVED NEW FLOOR PANEL P/N 52772658-15300, S/N TAG 00428628 LOCATED DRILLED & COUNTERSUNK EXISTING HOLES IAW DC8 SRM51 -1-22 & 51-3-2. ALODINED SDR RRXA003403Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR BOARD AT STA 450 TO 460 AND X-16 Z=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3.SDR RRXA003402Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN DECK FLOOR BOARD AT STA 1690 AND X=0 Z=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-3-0 AND DWG 5754SDR RRXA001726Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOORING AT STA 225 TO 208 AND RBL 10 TO RBL 45 Z AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW SUB-FLOOSDR RRXA000740Floorboard · wornDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE CABIN COCKPIT FLOOR PANEL AT STA 148 TO 168, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FLOOR PANEL SKIN IAW DC-8 SRM 53-2-3SDR RRXA003397Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBOARD AT STA 1420 AND X=0 Z=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3 AND 51-1-26.
Back to JASC 5321