Service difficulty reports · 49,402

Reports filed under 5321 · Fuselage Floor Panel, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5321'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 98FDEA00719Floor · corrodedNR 0444 CORROSION ON FLOOR PANEL CUTOUT UNDERSIDE AT BS 298, WL 178, LBL 31. *S/D* REMOVED WEB SECTION BS 294 TO 320, LBL 25 TO LBL 35. FABRICATED NEW WEB AND INSTALLED IAW FEDEX DRG 65-18915 AND FEDEX EA 7-5310-43158.Dec 1, 1998 · N506FE · Boeing 72725SDR DL757982573Deck · corrodedREPLACED AFT DECK AT FLOOR LEVEL STATION 1681 TO 1730 DUE TO CORROSION.Nov 30, 1998 · N608DA · Boeing 757232SDR CALA9802125Floor · corrodedINSPECTION FOUND CORROSION ON RT AFT LAV FLOOR PAN AT BS 1111 TO 1183. THE FLOOR PAN WAS REMOVED AND A NEW PAN WAS INSTALLED IAW SRM 51-30-2, 51-40-2 FIGURE 1, 51-10-2 AND MM 51-20-11.Nov 30, 1998 · N45793 · Boeing 727232SDR RRXA99242Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1440, BL 46 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED FILLER AND DOUBLER IAW SRM 53-2-3, PG 39-40. (CORROSION DAMAGE RECORDEDNov 15, 1998 · N792FT · Doug DC873FSDR RRXA99241Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1430, BL 6 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PER SRM 53-2-3, PG 39-40. (CORROSION DAMAGE RECORDENov 15, 1998 · N792FT · Doug DC873FSDR RRXA99240Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1300, BL 18 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED CORROSION AREA IAW SRM 53-2-3, PG 39-40. AFTER BLEND OUT, OUT OF LIMITS. Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99239Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1140, BL 18 RT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED CORROSION AT FLOOR PANEL AND INSTALLED DOUBLER ON DAMAGED AREA AS PER SRM 5Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99238Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1220 TO 1300, BL 18 RT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED REPAIR SECTION IAW DC-8 SRM 51-1-8, PG 39-40. (CORROSION DAMAGE Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99237Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1180, BL 50 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 39-40. FABRICATED DOUBLER FROM .080 IN 707Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99236Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1160, BL 50 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 39-40. FABRICATED DOUBLER FROM .080 IN 707Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99235Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1020, BL 50 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 39-40. FABRICATED DOUBLER FROM .080 IN 707Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99234Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1040, BL 18 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. CUT OUT DAMAGED AREA IAW SRM 53-2-20, PG 20. FABRICATED REPAIR PARTS PER 53-2-3, PNov 15, 1998 · N792FT · Doug DC873FSDR RRXA99233Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1280, BL 18 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED DAMAGED AREA IAW SRM 53-2-3. (CORROSION DAMAGE RECORDED IN EWA CORROSION PNov 15, 1998 · N792FT · Doug DC873FSDR RRXA99232Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1170, BL 16 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. CUT OUT DAMAGE, FABRICATED REPAIR PARTS IAW SRM 53-2-3, PG 39/40, AND 51-1-8, PG 17Nov 15, 1998 · N792FT · Doug DC873FSDR RRXA99231Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON CABIN FLOOR PANEL AT STA 1660, BL 32 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. CUT OUT DAMAGE IAW SRM 53-2-3. FABRICATED DOUBLER FROM .080 IN 7075T6, FILLER FROMNov 15, 1998 · N792FT · Doug DC873FSDR USAA980572Floor · crackedCLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A .75 INCH CRACK BS 277 STRINGER 13R AND STRINGER 14R STRAP. INSTALLED DOUBLER PER SRM 51-70-11 FIG 1. (M)Nov 13, 1998 · N335US · Boeing 737301SDR AU981446Floor Panel · cracked(AUS) COCKPIT LT FLOOR PANEL CRACKED IN AREA ADJACENT TO THE RT RUDDER PEDAL. PART TC: 1,420.Nov 9, 1998 · Grob G115CSDR RRXA98497Floor · crackedDURING MAINTENANCE VISIT, FOUND FLOOR PANEL WITH CRACKS THROUGH BOLT HOLES AT FS 435 TO 445 LBL 60. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED DER COTNEY ENGINEERING SKETCH SK98418, AREA TREATED IAW DC-8 SRM 51-1-8.Nov 5, 1998 · N995CF · Doug DC862SDR RRXA98482Floor · puncturedDURING MAINTENANCE VISIT, FOUND FLOOR PANEL AT STA 1423 BL 0 PUNCTURED. FABRICATED AND INSTALLED REPAIR ANGLE IAW FAA APPROVED DER COTNEY ENGINEERING SKETCH SK98541 AND DC-8 SRM 51-1-21, AREA TREATED IAW DC-8 SRM 51-1-8.Nov 4, 1998 · N995CF · Doug DC862SDR RRXA99733Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1250 BL 48R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3,Oct 28, 1998 · N795FT · Doug DC873FSDR AU981497Panel · cracked(AUS) RIGHT FLOOR ASSEMBLY CRACKED IN AREA ADJACENT TO COPILOT'S LEFT PEDAL. PART TC: 1,297.Oct 26, 1998 · Grob G115CSDR AU981496Panel · cracked(AUS) LEFT FLOOR ASSEMBLY CRACKED IN AREA ADJACENT TO PILOT'S RT PEDAL. PART TC: 1,297.Oct 26, 1998 · Grob G115CSDR AU981448Floor Panel · cracked(AUS) RIGHT COCKPIT FLOOR PANEL CRACKED. PART TC: 1,300.Oct 26, 1998 · Grob G115CSDR AU981447Floor Panel · cracked(AUS) LT COCKPIT FLOOR ASSEMBLY CRACKED. PART TC: 1,300.Oct 26, 1998 · Grob G115CSDR RRXA99734Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1280 TO 1300 BL 48R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMOct 24, 1998 · N795FT · Doug DC873FSDR ORJA98335Floor · corrodedOKC - LEVEL 2 CORROSION NR 5 FLOORBOARD PANEL AFT PIT IS CORRODED. FABBED NEW FLOOR PANEL FOR AFT PIT IAW DC9 SRM 51-10-2. OK TO TREAT. OK TO PRIME. REF: 10260 N/R 1000-0146. (X)Oct 24, 1998 · N836RA · Doug DC983SDR RRXA99735Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1568 TO 1577 BL 2L TO 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-Oct 23, 1998 · N795FT · Doug DC873FSDR AU981457Panel · cracked(AUS) RIGHT COCKPIT FLOOR PANEL ASSEMBLY CRACKED. PART TC: 1,498.Oct 23, 1998 · Grob G115CSDR AU981456Panel · cracked(AUS) LEFT FLOOR PANEL ASSEMBLY CRACKED. PART TC: 1,498.Oct 23, 1998 · Grob G115CSDR P5CA9801550Floor · delaminatedREPLACED UPPER DECK FLOOR PANELS AT BS 720R DUE DELAMINATION. REMOVED AND REPLACED PER SRM 53-22-01, 51-10-01 AND 51-30-02.Oct 17, 1998 · N851FT · Boeing 747122SDR DHL9980197CFloor Panel · crackedAT C-CHECK, FWD LOWER CARGO COMPT STA 180 RT UNDER BRACKET SUPPORT ATTACHING TO FLOOR PANEL CRACKED. REMOVED DAMAGED SECTION, FABRICATED DOUBLER AND INSTALLED PER SRM 53-2-0, 5 X 7.Oct 17, 1998 · N801DH · Doug DC873FSDR RRXA99736Floor · corrodedDURING A MAINTENANCE VISIT, FOUND BULGE IN MAIN CABIN FLOOR PANEL AT STA 300 BL 36R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3, FIG 10. (CORROSION DAMAOct 16, 1998 · N795FT · Doug DC873FSDR RRXA99750Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 410 TO 470 BL 40L TO 2L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SOct 15, 1998 · N795FT · Doug DC873FSDR RRXA99749Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 375 TO 400 BL 20L TO 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99748Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 480 TO 520 BL 2L TO 10L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99747Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 550 TO 590 BL 2L TO 40L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SOct 15, 1998 · N795FT · Doug DC873FSDR RRXA99745Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 798 TO 820 BL 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3, FIOct 15, 1998 · N795FT · Doug DC873FSDR RRXA99744Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 530 TO 540 BL 4R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SRM 53-2Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99743Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 857 BL 44R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SRM 53-2-3, FIOct 15, 1998 · N795FT · Doug DC873FSDR RRXA99742Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 857 TO 781 BL 48R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SRM 53-Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99741Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 510 BL 2R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3, FIG 10. Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99740Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 310 BL 4R TO 44R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99739Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 320 BL 44R TO 2R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53Oct 15, 1998 · N795FT · Doug DC873FSDR RRXA99729Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 680 TO 660 BL 4L TO 34L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SOct 15, 1998 · N795FT · Doug DC873FSDR CA981109024Floorboard · cracked(CAN) DURING ANNUAL INSPECTION, A CRACK WAS FOUND IN THE FLOOR PANEL UNDER THE COPILOT'S SEAT TRACK VERY AFT POSITION. CRACK WAS PARALLEL TO THE END OF THE SEAT TRACK AND THEN RUNS FORWARD ON BOTH SIDES. CRACK ALSO FOUND UNDER THE INBOARD SEAT TRACK POSITION.Oct 15, 1998 · Cessna 150MSDR RRXA99761Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1020 TO1060 BL 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 5Oct 14, 1998 · N795FT · Doug DC873FSDR RRXA99760Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1060 BL 0R TO 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53Oct 14, 1998 · N795FT · Doug DC873FSDR RRXA99759Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 BL 18R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLES, DOUBLER, AND FILLER Oct 14, 1998 · N795FT · Doug DC873FSDR RRXA99757Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1400 TO 1420 BL 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAOct 14, 1998 · N795FT · Doug DC873FSDR RRXA99756Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1300 TO 1380 BL 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM Oct 14, 1998 · N795FT · Doug DC873F
Back to JASC 5321