JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA99755Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1300 TO 1320 BL 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99754Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1320 TO 1340 BL 16R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99751Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 960 TO 1000 BL 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99746Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 920 TO 960 BL 40L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 5SDR RRXA99738Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 990 BL 16L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3, SDR RRXA99737Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 900 BL 50R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC-8 SRM 53-2-3, FISDR RRXA99730Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1060 TO 1140 BL 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99728Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 702 TO 685 BL 6L TO 22L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIR ACCOMPLISHED ON N/R 5508. (CORROSION DAMSDR RRXA99727Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 760 BL 6L TO 25L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53SDR RRXA99726Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99725Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1220 TO 1300 BL 16R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99724Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1020 TO 1060 BL 48L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99723Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1060 BL 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99722Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1060 TO 1140 BL 16L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99721Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 50L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99720Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99719Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1220 TO 1300 BL 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99718Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 16L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99717Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 850 TO 960 BL 50L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 5SDR RRXA99716Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 920 TO 940 BL 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53SDR RRXA99715Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 900 TO 960 BL 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 5SDR RRXA99713Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 44R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99712Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 16R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99711Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1200 BL 18R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3,SDR RRXA99710Floor · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1140 TO 1220 BL 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99709Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1220 BL 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3, SDR RRXA99708Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 12240 TO 1300 BL 40L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99707Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1340 TO 1380 BL 50L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99706Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1360 TO 1400 BL 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99705Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1440 TO 1460 BL 44L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRMSDR RRXA99704Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR BOARD AT STA 1580 BL 20L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3,SDR RRXA99703Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR BOARD AT STA 1680 BL 16L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3,SDR RRXA99702Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR BOARD AT STA 1620 BL 16L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3,SDR RRXA99701Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1220 TO 1300 BL 16L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR DOUBLER IAW DC-8 SRM 53-2-3, FIG 1SDR RRXA99766Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1400 TO 1440 BL 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM SDR RRXA99765Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1500 TO 1580 BL 0R TO 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-SDR RRXA99764Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1500 BL 0 TO 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DSDR RRXA99763Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1520 BL 30R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DC-8 SDR RRXA99762Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1500 BL 0 TO 6L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DSDR RRXA99758Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1400 TO 1420 BL 26R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW DC-8 SRM 5SDR RRXA99753Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1480 BL 24R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. BLEND OUT WITHIN LIMITS. (CORROSION DAMAGE RECORDED IN EWA SDR RRXA99752Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1560 TO 1580 BL O TO 6R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PART IAW DC-8 SRSDR RRXA99714Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1540 BL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-3, FSDR P5CA9801537Floor · delaminatedFLOOR PANEL STATION 500 TO 580 RBL 20 FOUND DELAMINATED. REMOVED AND REPAIRED PER SRM 51-10-01 AND 51-30-02.SDR DL757982104Floor Panel · corrodedMID VISIT, CORROSION ON FIXED FLOOR PANEL RT STA 760 TO 800, REPAIRED.SDR RRXA99637Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR PANEL AT STA 1664 AND BL 10 LEFT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3 FIGURE 10. (CORROSION DASDR VJ9800524Floor Panel · corrodedFWD ENTRY WAY FLOOR PANEL, NR 4691, CORRODED BEYOND LIMIT IAW DC9 SRM 53-01, FIG 1. REMOVED HAT SECTIONS, FABRICATED AND INSTALLED NEW SKIN, REINSTALLED HAT SECTIONS IAW DC9 SRM 51-20-0, 51-10-3, 51-30-2, 53-20-0 FIG 2A, 51-10-2 AND 51-10-4.SDR SWAA982452Floorboard · damagedDURING SCHEDULED TRAN CHECK, FOUND DAMAGED FLOORBOARD PLATAFORM IN TAIL COMPARTMENT LOCATED BETWEEN BS 1040 AND BS 1064. REMOVED AND REPLACED PER BOEING SRM.SDR RRXA99638Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR PANEL AT STA 1000 AND BL 27 RIGHT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-7-3. (CORROSION DAMAGE RECOSDR ORJA9911Floor · corrodedOKC - LEVEL 2 CORROSION. AFT PIT CENTER FLOOR PANEL (METAL) JUST AFT OF CARGO DOOR HAS AREAS OF CORROSION. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. FABBED NEW PANEL IAW DC9 SRM 51-10-2. TREATED AND PRIMED IAW DC9. SRM 51-10-3. REF: W.O. NR 9504; 1
Back to JASC 5321