SDR RRXA991266Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 380 AND STA 580 AT BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991265Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 640 AT BL 35 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991264Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 380, BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991271Floor Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 280, BL 36 RIGHT AND WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DSDR RRXA991269Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 700, BL 28 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND NEW SECTION OF FLOOR PANEL ISDR RRXA991268Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 670, BL 49 RIGHT, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10.SDR RRXA991267Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 320 AT BL 54 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991274Floor Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 690 AND STA 710 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991273Floor Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 640 AND STA 660 AT BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991272Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 538 AND STA 548 AT BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR GTIA9900922Floor · crackedMHV - CO-PILOT RUDDER FLOOR PANEL HAS CRACKED STRUCTURE FORWARD END BOTTOM. CUT OUT CRACK INSTALLED ANGLE DOUBLER PER DC9 IAW SRM 53-01-0 PAGE 1 AND 10 EXAMPLED FORMED ANGLE DOUBLER PER DC9 SRM 51-10-2 PAGE 1 FIG 2. INSTALLED FASTENER PER DC9 SRN 51-30-2. (SDR RRXA991476Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, MAIN CARGO DOOR PLANK BETWEEN STA 640 AND STA 700, AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. BI REPAIR DOUBLER IAW DC8 SRM 53-2-3, FIG 10. (CSDR RRXA991475Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BL 36 LEFT BETWEEN STA 640 AND STA 720. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER REPAIR IAW DC8 SRM 51-1-SDR RRXA991283Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, MAIN CARGO COMPT NR 9 FLOOR PANEL AT STA 863, BL 46 LEFT, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FLOOR PANEL IAW DC8 SRM 5SDR RRXA991371Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 1480, BL 38 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-0 PGS 2P FIG 1SDR CALA9900211Floorboard · corrodedINSPECTION FOUND FLIGHT DECK FLOORBOARD NR 216AF DELAMINATED AND CORRODED. A NEW FLOORBOARD WAS INSTALLED AND SEALED IAW ECRA 5100-01844.SDR AT9900280Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE FORWARD PIT CENTER FLOOR PANEL CORRODED ALONG THE EDGES AND ELONGATED HOLES WITH NO EDGE DISTANCE. FABRICATED REPAIR FLOOR PANEL, LOCATED, DRILLED, DEBURRED, TREATED AND PRIMED IAW DC9 SRM 51-10-3, 53-01 FIG 1, SDR USAA990125Floor Panel · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A CORROSION AREA FLOOR PANEL UNDER LEFT LAV TOILET TANK. INSTALLED REPAIR FLOOR PANEL PER SRM 53-10-05. (M)SDR SWAA990349Floor · corrodedDURING SCHEDULED D-CHECK, FOUND CORROSION ON FLOOR WEB AT BS 1016 LBL 38 TO 41.5 WL 208.5. REMOVED CORROSION ON FLOOR WEB BS 1016 LBL 38 - 41, WL 208.5 FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW WEB PER SRM.SDR TWAA9903803Floor · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION AROUND THE RIVETS IN THE CENTER FLOOR PANEL, BETWEEN LAVATORIES. THE EDGE STIFFENERS WERE CRACKED AND WORN. REPLACED PANEL PER SPM 6-70-01.SDR AT9900285Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE G-4 FLOOR PAN SKIN CORRODED. REMOVED FLOOR PAN HAT SECTION, FABRICATED NEW SKIN, TREATED, PRIMED, INSTALLED SKIN AND REINSTALLED HAT SECTION IAW DC9 SRM 51-30-2, 51-10-3 AND 51-10-2.SDR AALA990236Floor · corrodedTUL - FOUND CORROSION ON LEFT AFT LAV FLOOR STATION 1166-1162 LBL 24-29. REPLACED LEFT LAV FLOOR PAN PER SRM 51-10-1 AND ESO 11697, DATED 1-14-99. (M)SDR UPS99829014Floor · crackedINSPECTION TYPE:C2 AFT FLOOR PANEL F216A IS CRACKED. FABRICATED NEW PANEL IAW DAC DWG 5755032. ALODINED AND PRIMED IAW DC8 SRM 51-1-8.SDR AT9900246Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE FLOORBOARDS NR 2 AND 7 IN PASSENGER CABIN CORRODED AND WITH EXCESSIVE DAMAGE. REMOVED FLOORBOARDS AND FABRICATED NEW PANEL IAW B737 SRM 53-20-1, 51-40-10 PG 4 AND 53-20-2.SDR 99ZZZX1306Floor Panel · corrodedDURING A C-CHECK, CORROSION NOTED IN FORWARD LAVATORY FLOOR PANEL FROM BULKHEAD TO STA 312.SDR GTIA9900923Floor · crackedMHV - FORWARD PASSENGER FLOOR PANEL FOR FS 200-243 LBL 21-42, CORNER CRACKED (TORN). FABRICATED FLOORBOARD IAW DC9 SRM 53-21-0 PAGE 6 INSTALLED STIFFENERS IAW DC9 SRM 51-30-2 PAGE 30. ALODINED AND PRIMED PER IAW DC9 SRM 51-10-3. INSTALLED RIVETS IAW DC9 SRMSDR AT9900235Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE AFT CARGO COMPARTMENT CABIN FLOOR PANEL (E17) LOWER SURFACE AT BS 907 TO 927 RBL 49 CORRODED. FABRICATED PANEL DUE TO EXTENSIVE CORROSION AND BREAKAGE IAW B737 53-20-1 AND 51-40-10 PG 4.SDR P5CA9900167Floor · delaminatedBS 540 TO 600 LBL 28 FLOOR PANEL FOUND DELAMINATED. REPAIRED PER SRM 51-40-06.SDR P5CA9900166Floor · delaminatedBS 520 TO 600 LBL 47 FLOOR PANEL FOUND DELAMINATED. REPAIRED PER SRM 51-40-06.SDR GTIA9900902Floor · crackedMHV - FS 617 RBL 50 RIGHT SIDE FLOOR CHIME PLATE CRACKED ON BOTH SIDES OF LIGHTENING HOLE. REMOVED AND REPLACED FLOOR CHIME PLATE IAW SRM 51-00 AND 51-30-02 JOB COMPLETE. (M)SDR AWXA9900051Beam · misdrillLT MLG SUPPORT BEAM LOWER CHORD DAMAGED BY DRILL WHILE REMOVAL OF PANEL LOWER WBL 109.895. HOLES CLEANED UP BY BLENDING AND REAMING AT NR 2 AND 3 FLAP PEEN AREA. INSTALLED RIVET SLUG BACR 1580. ALODINED AND PRIMED AREAS OF HOLES PER AWA ER 2-57-43-18.SDR GTIA9900908Floor · corrodedMHV - FORWARD PASS CABIN FLOOR AT FS 200-243 RBL 21-42 LIGHT CORROSION AFTER CORROSION WAS REMOVED FOUND AREA TO BE OUT OF LIMITS REF CARD W144. REMOVED AREA MATERIAL ID 7075T6.040 PER SRM 53-10-0. FABRICATED REPAIR PARTS PER SRM 53-01 FIG 4 ALODINED AND PRISDR GTIA9900907Floor · corrodedMHV - FLOORBOARDS FS 160-200 BL 0 TO LBL 42 CORRODED AND SUPTS CRACKED. FABRICATED A NEW SKIN IAW DC9 SRM 53-21-0, 4B INST HAT SUPPORTS IAW DC9 SRM 53-21-0. ALODINE AND PAINT IAW DC9 SRM. INSTALLED RIVETS IAW SRM DC9. (M)SDR QXEA9900293Floor · puncturedPDX - CO-PILOTS FLOOR AT INBOARD SEAT TRACK HAS A PUNCTURE IN FLOOR. REPAIRED IAW HORIZON AIR EA 4-53-686.SDR RRXA991315Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, ENTRANCE AND LAV FLOOR, BETWEEN STA -8.0 AND STA 80. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PANEL SKINS ON 9 EA PANELS IAW DC8 SRSDR REXA99003Floor · damagedCOCKPIT FLOOR ENTRY WAY DAMAGED. REPAIRED BY FABRICATING AN ANGLE FROM 2024T3 .040 IAW SRM. (M)SDR EISA99012Floor · corrodedDURING ACCOMPLISHED OR ROUTINE C-CHECK WORK CARD, FOUND CORROSION ON FLOOR WEB AT FS 137 LBL 20 BETWEEN CAPTAINS INBOARD AND OUTBOARD SEAT TRACKS. REMOVED CORROSION, FABRICATED DOUBLER PER SRM 53-04 FIGURE 4 AND INSTALLED PER SRM 51-30-8. (M)SDR AT9900113Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND CABIN FLOORBOARD PANEL AT STA 680-756, STA 965-996, AND FLOOR BOARD NR 97 CORRODED, MISSING CHAFFED STRIP, ELONGATED HOLES, RIVET HEADS PULLING UP, AND MISSING INSULATION. FABRICATED NEW FLOORBOARD, HAT CHANNELS, ISDR QXEA9900169Floor · damagedPDX - FLOOR PANEL 94AM CORE DAMAGED ALONG EDGES, LOWER SKIN PUNCTURE. REPAIRED IAW HORIZON AIR EA 4-53-666.SDR QXEA9900168Floor · damagedPDX - FLOOR PANEL 94AJ CORNER DAMAGED. REPAIRED IAW HORIZON AIR EA 4-53-672.SDR QXEA9900167Floor · damagedPDX - FLOOR PANEL 94AK HAD CORE DAMAGE ALONG EDGES AND SKIN PUNCTURE. FABRICATED A NEW PANEL IAW HORIZON AIR EA 4-53-666.SDR 99ZZZX582Floorboard · crackedDURING ANNUAL INSPECTION, FOUND THE FLOOR PAN CRACKED AT THE END OF THE COPILOT'S INBOARD SEAT TRACK. THIS IS THE FORTH PLANE OUT OF SIX 152'S THAT HAVE HAD TO BE REPAIRED. THE SEAT TRACK IS WEARING INTO THE RADIUS OF THE BEND OF THE FLOOR PAN. THERE IS NO SDR DHL9980517CFloor · crackedAT CHECK, MAIN CARGO COMPT FLOOR PANEL LT SIDE STA 1680 HAS PREVIOUS REPAIR. REMOVED COVER FROM PANEL AND CRACKED CHANNELS AT LEFT SIDE STA 1680, FABRICATED NEW COVER (20 X 20) AND 2 CHANNELS 20 X 3 PER SRM 53-7-3. N/R 952SDR AT9900110Panel · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND FORWARD PIT FLOOR PANELS AT STA 351-503, FORWARD PIT AFT BULKHEAD LEFT AND RIGHT PANEL, FORWARD CARGO PIT FLAP VALVE AT STA 595 L-29-30, AND FORWARD CARGO FLOOR SUPPORT AT STA 218-237 WITH CORROSION, ELONGATED HOLESSDR DHL9980516CFloor · crackedAT C-CHECK, MCC FLOOR PANEL STA 1746 BOTTOM CHANNEL IS DETERIORATED AND HOLE CRACKED. FABRICATED DOUBLER REPAIR PER SRM 53-2-0 AND INSTALLED PER SRM 51-1-21. N/R 947SDR AT9900086Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND FORWARD CARGO CENTER FLOOR BOARD AT STA 218 THRU 446 CORRODED AROUND EDGES, TOP SIDE AND BETWEEN LAYERS. REMOVED AND REPLACED CORRODED FLOOR PANEL, FABRICATED NEW FLOOR PANELS, TREATED, PRIMED, DEBURRED AND INSTALSDR 99ZZZX393Floorboards · crackedCENTER ISLE FLOORBOARDS FORWARD OF SPAR ARE SPLIT DOWN THE CENTER WITH A SINGLE CAMLOC FASTENER TO HOLD EACH SET OF PANELS TOGETHER. PANELS ARE VERY SPONGY FEELING WHEN WALKED ON, AND THE FORWARD PANEL FLEXES DOWN AND RESTS ON THE NON-STRUCTURAL THIN PLASTIC SDR USAA980652Floor · corrodedCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND CORROSION 40 INCH BY 40 INCH AFT GALLEY FLOOR PAN AT BS 1700 DECK PLATE, CORROSION TASK NR C53-252-03. REPAIRED PER BOEING 757-200 SRM 51-30-01, 51-40-02 AND 51-20-05. (M)SDR AT9900058Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE AFT CARGO CENTER FLOOR PANEL CORRODED AND WITH ELONGATED HOLES AT STA 756 TO 794. REMOVED PANEL, FABRICATED, TREATED, PRIMED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 51-10-2, 53-21-0 FIG 10, AND 51-10-4.SDR CALA9802132Floor · corrodedINSPECTION FOUND CABIN FLOOR PAN CORRODED AT AFT ENTRY STA 1177 TO 1171, BL 0 TO LBL 18. THE FLOOR PAN WAS REMOVED AND A NEW FLOOR PAN WAS INSTALLED IAW SRM 53-10-2.
Back to JASC 5321