SDR CALA9801054Floor · crackedINSPECTION FOUND LT FLOOR MEMBRANE DISTORTED AND CRACKED AT STA 627 TO 657. THE FASTENERS WERE REMOVED IAW SRM 51-30-2. A REPAIR WEB WAS FABRICATED AND INSTALLED IAW SRM 53-11-3, 51-10-3, AND 51-30-2.SDR CALA9801046Floor · crackedINSPECTION FOUND FLOORBOARD NR 82 HAT SECTIONS WORN THROUGH AND CRACKED. A FLOOR PANEL AND HAT SECTIONS WERE FABRICATED AND INSTALLED IAW SRM 53-21-0, 51-10-3, AND 51-30-2.SDR CALA9801020Floor · corrodedINSPECTION FOUND LT AFT LAV FLOOR WEB CORRODED AT BS 980 TO 996, LBL 18. THE FLOOR WEB WAS REMOVED, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-10-4, 51-30-2, 51-10-3, AND 51-30-1.SDR CALA9801104Floorboard · crackedINSPECTION FOUND CRACKS AT SCREW HOLES OF FLOORBOARD NR 51, STA 465 TO 579 AND FLOORBOARD NR 40, STA 578 WITH SCREWS PULLING THROUGH. NEW FLOORBOARDS WERE FABRICATED AND INSTALLED IAW SRM 53-05, PAGE 1, 51-20-0, 51-30-2, 51-10-2, 51-10-3, AND 51-70-2.SDR CALA9801005Floorboard · crackedINSPECTION FOUND CRACKS IN LT FLOORBOARD NR 58. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-21-0, 51-70-1, AND 51-70-3, PAGE 1 AND 2.SDR CALA9801004Floorboard · delaminatedINSPECTION FOUND FLOORBOARD AT STA 200 TO 244 DELAMINATING. A NEW FLOORBOARD WAS FABRICATED AND INSTALLED IAW SRM 53-05, PAGE 122B.SDR CALA9801003Floorboard · puncturedINSPECTION FOUND A HOLE IN FLOORBOARD PANEL NR 71. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-01, FIGURE 2, 51-10-3, PAGES 15-16, AND 51-30-2, PAGES 1-30.SDR CALA9801002Floorboard · crackedINSPECTION FOUND .5 INCH CRACKS AT SCREW HOLES OF FLOORBOARD NR 51. REPAIRED IAW SRM 53-01, FIGURE 2, PAGE 3.SDR CALA9801103Floorpanel · corrodedINSPECTION FOUND COCKPIT FLOORBOARD PANEL NR 12 CORRODED. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-21-0 AND 53-05, PAGE 1.SDR CALA9800986Floorboard · corrodedINSPECTION FOUND CO-PILOT'S FLOORBOARD CORRODED AT STA 130, RBL 34 TO RBL 50. THE FLOORBOARD AND SKIN WERE REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-21-0, FIGURE 2F, 51-30-2, 51-10-2, 51-10-4, 51-10-3 AND MM 53-20-1.SDR HEEA0014612Floor Panel · corrodedFLOOR PANEL CORRODED AND SEPARATED.SDR CALA9800980Floorboard · puncturedINSPECTION FOUND SURFACE SKIN OF CABIN FLOORBOARD PANEL NR 77 PUNCTURED. A DOUBLER, HAT SECTION, AND REPAIR PANELS WERE FABRICATED AND INSTALLED IAW SRM 53-05, FIGURE 1, 51-70-2, 51-10-3, AND 51-20.SDR CALA9800974Floorboard · corrodedINSPECTION FOUND COCKPIT FLOORBOARD CORRODED ON PILOT'S SIDE IN CORNER FORWARD OF E AND E COMPARTMENT ACCESS DOOR AT STA 15L. THE FLOOR PANELS WERE REMOVED IAW SRM 51-30-1. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-10-3 AND 51-30-2.SDR CALA9800970Floorboard · crackedINSPECTION FOUND FLOORBOARD NR 71 WITH THREE EACH BLOWN OUT HOLES AND ONE CRACKED. THE CRACK WAS STOP DRILLED. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED ON FLOORBOARD OVER BLOWN OUT HOLES AND CRACK IAW SRM 53-01, FIGURE 2, 51-10-3, PAGE 15 AND 16, 51-10-SDR SWAA981067Floor · corrodedDURING SCHEDULED D-CHECK, FOUND CORRODED FLOOR WEB AT BS 1030, LBL 9, WL 208. REPAIRED PER BOEING SRM.SDR CALA9800966Floorboard · crackedINSPECTION FOUND FLOORBOARD NR 72 FORWARD LEADING EDGE AND AFT SCREW HOLES CRACKED AND WORN BETWEEN STA 756 AND 832. TWO EACH REPAIR DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 53-21, FIGURE 4, 53-01, FIGURE 2, SHEET 3, 51-10-3, AND 51-30-2.SDR CALA9800965Floorboard · corrodedINSPECTION FOUND FLOORBOARD NR 36 HAD CORROSION AT FOUR SCREW HOLES ON END OF PANEL, STA 389. THE FLOORBOARD WAS REPAIRED IAW SRM 53-01, FIGURE 1, SHEET 2, SRM 53-21-0, AND 51-30-2.SDR TWAA9814706Floor · corrodedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR MEMBRANE CORRODED AND CRACKED AT FS 921, RBL 58. REMOVED CORROSION PER SRM 51-10-3. INSTALLED DOUBLER REPAIR PER SRM 53-01 PAGE 8.SDR MALA976465Floor · corrodedDURING C CHECK, CAPTAIN'S FLOOR AREA AROUND RUDDER PEDAL AND AFT OF SEAT AREA HAS SURFACE CORROSION. MAINTENANCE CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-60-50.SDR MALA976464Floor · corrodedDURING C CHECK, CO-PILOT'S FLOOR AREA HAS SURFACE CORROSION. MAINTENANCE REPAIRED BY INSTALLING DOUBLER PER SRM 51-20-42 AND 51-20-43.SDR CALA9800909Floor · crackedINSPECTION FOUND SEVERAL CRACKS IN RT NR 61 FLOORBOARD. A FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 51-10-4, 51-30-2, AND 51-10-3.SDR 98ZZZX2721Floor · corrodedCORROSION CAUSED BY LIQUIDS FROM AFT GALLEYS AND LAVATORIES PENETRATING THROUGH GALLEY FLOOR COVERING. APPLIED CORROSION INHIBITING COMPOUND ON THE FLOOR SUPPORT-TEE. RECOMMENDED TO RE-APPLY EACH D-CHECK. RECOMMENDED TO PERIODICALLY INSPECT FLOOR COVERING ASDR IXXA9800074Floor · corrodedDURING ROUTINE C CHECK INSPECTION, CORROSION WAS DETECTED ON MAIN CABIN FLOOR PRESSURE PANEL BETWEEN FUSELAGE STATION 863 AND 878, BL +X4 TO -X5.50. REPAIR ACCOMPLISHED CORROSION BLEND OUT, FABRICATION AND INSTALLATION OF A REPAIR DOUBLER IN ACCORDANCE WITH FSDR QXEA9800698Floor · corrodedCORROSION ON COCKPIT FLOOR UNDER CO-PILOTS INBOARD AND OUTBOARD SEAT RAILS. REPAIRED IAW FOKKER SRM 51-10-04, PARAGRAPH 4, PAGE 9.SDR CALA9800827Floor Panel · crackedFLOOR PANEL FWD PIT FS 380 TO 420 HAS TEARS. FABRICATED FWD PIT PANEL PER ECRA 2550-01046.SDR RRXA99444Floor · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN CENTER WING FLOOR PANEL NR 12 PARTS RACK AT STA 870 TO 1000 X45R LONG 21. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAISDR RRXA99490Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR BOARD IN LEFT HAND TUNNEL AT STA 70 TO 80 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DAC DWG 5892154 AND DSDR RRXA99489Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR BOARD AT STA 330 TO 335 BL 21L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-0. (CORROSION DAMAGE RECORDSDR P5CA9800920Floor · corrosionLEVEL 1 CORROSION FOUND UNDER FLOOR RIGHT HAND SIDE STA 460 WBL R199.8. CORROSION REMOVED AND AREA REPROTECTED AS PER SRM 51-10-01 AND 51-10-02.SDR TWAA9807014Floor · corrodedMCI - DURING OP 15 MAINTENANCE CHECK, FOUND LIGHT CORROSION AROUND SCREW HOLES IN FLOOR MEMBRANE AT FS 1250, LBL 47 TO LBL 53. REMOVED CORROSION PER SRM 51-10-3. REPAIRED PER SRM 53-10 FIG 2. (X)SDR TWAA9806916Floor · corrodedMCI - DURING OP 15 MAINTENANCE CHECK, FOUND HOLD CORRODED THROUGH CABIN FLOOR MEMBRANE AT STATION 172, RBL 52. REPAIRED PER SRM 53-01, FIG 4 AND TWA STD PRACTICES. (M)SDR EISA98098Floor · crackedDURING ACCOMPLISHMENT OF ROUTINE C-CHECK WORKCARD, FOUND FLOOR PANEL AT STA 579 TO STA 680, RIGHT-HAND OF CENTER, WITH CRACKED OUT FASTENER HOLES. FABRICATED AND INSTALLED REPAIR PER 53-03, 51-70-0, AND 51-30-2. TT: 66,670:41 HOURS. TC: 61,562. (X)SDR EISA98097Floor · crackedDURING ACCOMPLISHMENT OF ROUTINE C-CHECK WORKCARD, FOUND LEFT-HAND CENTER FLOORBOARD, STA 579 TO STA 680, WITH 6 EACH FASTENER HOLES CRACKED OUT. FABRICATED AND INSTALLED REPAIR PER 53-05, 51-70-0, AND 51-30-2. TT: 66,670:41 HOURS. TC: 61,562. (X)SDR RRXA99434Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR PANEL AT STA 1260 TO 1250, X+21, Z+1. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-0 AND 53-3-0. SDR RRXA99435Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO CABIN AREA FLOOR BOARD AT STA 1220 TO 1232, X+51.5 TO +57.5, Z+0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SSDR RRXA98154Plank · corrosionDURING A MAINTENANCE VISIT, FOUND FLOOR PLANK EDGE CORRODED BEYOND LIMITATIONS IAW DC-8 SRM, AT STA 1580 TO 1689. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER TIMCO ENGINEERING SKETCHSDR HEEA0013670Floor Panel · mismanufacturedFLOOR PANEL EDGE DISTANCE TOO SHORT RIGHT HAND OUTBOARD SIDE.SDR VJ9800334Floor · corrodedCORROSION ON FLOOR PANEL AT AFT ENTRANCE (LEVEL 2). FABBED NEW FLOOR PANEL AND HAT CHANNEL SUPPORTS, TREATED, PRIMED FLOOR PANELS AND HAT CHANNELS. INSTALLED NEW AND USABLE ORIG HAT CHANNELS TO NEW FLOOR PANEL AT AFT ENTRANCE.SDR VJ9800329Floor · corrodedREMOVED CORRODED AREA OF FLOOR PANEL WEB STA 180-200 BL 0 TO BL 44 LT. CORROSION LEVEL 2. FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-01 FIG 4.SDR VJ9800332Floor · corrodedCABIN FLOORBOARD, BETWEEN RT I/B SEAT TRACK AND RT SIDE WALL AT FS 237, FWD WND IS CRACKED AND CORRODED (LEVEL 2) PANEL NR 21. CUT OUT DAMAGED AREA, FABRICATED DOUBLER AND INSTALLED IAW DC-9 SRM 53-01 FIG AND 51-30-3.SDR AU980430Floor · corroded(AUS) BOTH PILOT'S AND COPILOT'S FLOOR SKINS BADLY CORRODED FORWARD OF DOOR.SDR P5CA9800729Floor Panel · corrosionLEVEL 1 CORROSION AT FLOOR PANEL FUSELAGE BODY STATION 520 TO 540 BL 8. CORROSION REMOVED AND PANEL REPLACED AND REPROTECTED PER SRM 51-01-01 AND 51-10-02.SDR P5CA9800533Floor Panel · damagedUPPER DECK BS 520/600 RPL 9/27 FLOOR PANEL DAMAGE. REPLACED FLOOR PANEL PER SRM 53-21-02.SDR P5CA9800529Floor Panel · damagedMAIN DECK BS 1450 TO 1460 FLOOR PANEL DAMAGED. REPAIRED PER SRM 53-21-02.SDR P5CA9800525Floor Panel · damagedFWD CARGO COMPARTMENT BS 570/600 FLOOR PANEL DAMAGED. REPAIRED DAMAGE PER SRM 51-40-02.SDR CALA9800487Floor Web · crackedINSPECTION FOUND A 5 INCH CRACK ON FORWARD CARGO LOWER FLANGE OF FLOOR WEB AT STA 879 LBL 50. THE FLANGE WAS TRIMMED AND BLENDED OUT AND THE AREA WAS REWORKED. TWO ANGLES WERE INSTALLED IAW SRM 53-00-01, FIGURE 3, 51-20-00, AND 51-31-01.SDR TWAA9806910Floor · crackedMCI - DURING OP 15 MAINTENANCE CHECK, FOUND CABIN FLOOR MEMBRANE CRACKED BETWEEN STATION 560 AND 579, APPROX 58 INCH RBL, UNDER AFT END OF FLOOR PANEL 37. REPAIRED PER SRM 53-01, FIG 4. (M)SDR TWAA9806909Floor · crackedMCI - DURING OP15 MAINTENANCE CHECK, FOUND CABIN FLOOR MEMBRANE CRACKED BETWEEN STATION 579 AND 598, APPROX 58 INCH RBL, UNDER FWD END OF FLOOR PANEL 43. REPAIRED PER SRM 53-01, FIG 4. (M)SDR RRXA98197Floor · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR PANEL AT STA 45. REMOVED OLD FLOOR, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW ENGINEERING DIRECTIVE EDE 04-1 AND STC 1802SO.SDR 98UAL900146Floor · corrodedFOUND MID GALLEY FLOOR PANELS (REF IPC 25-31-01-075) WHICH HAD HEAVY CORROSION ON THE AFT EDGE OF THE FORWARD PANEL AND THE FORWARD EDGE OF THE REAR PANEL. THERE WAS NO SEALANT BETWEEN THE THRESHOLD PLATE AND THE GALLEY FLOOR PAN. THIS CONDITION ALLOWED MOIS
Back to JASC 5321