JASC 5321

Service difficulty reports · 49,402

Reports filed under 5321 · Fuselage Floor Panel, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5321'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR VJ9800346Floor · corrodedCABIN FLOOR BOARD CORRODED BEYOND LIMIT AT STA 160-200, RBL 44-54. STOP DRILLED CRACK AND FABRICATED REPAIR IAW DC9 SRM 53-01, FIG 2. HFEC CRACK CONTAINED AT STOP HOLE DC9 SPM NTM PART 06. TREATED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED REPAIR IAW DC9 SRAug 18, 1998 · N938VV · Doug DC932SDR VJ9800295Floor · corrodedDURING C-CHECK AT 31J, FOUND CABIN FLOOR BOARD STA 160 TO 200 RBL 44 TO 54 HAS CORROSION. MECHANICALLY REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS WITH 100 PERCENT OF THE MATERIAL LOSS AROUND THE NET PLATE HOLE. CRACK ALSO FOUND WHEN CLEANING AREA FOR REAug 18, 1998 · N938VV · Doug DC932SDR SWAA981684Floorboard · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION AT BS 767-847 LBL 8 AROUND FLOORBOARDS HOLES. REPAIRED PER BOEING SRM.Aug 9, 1998 · N301SW · Boeing 7373H4SDR SWAA981683Floorboard · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION AT BS 767-847, LBL 3 AROUND FLOORBOARDS HOLES. REPAIRED PER BOEING SRM.Aug 9, 1998 · N301SW · Boeing 7373H4SDR DHL9880333CFloor · crackedAT C CHECK, PANEL ON RACK NR 1 A, B FLOOR PANEL NR 5 RT STA 50-62 DIRTY AND CRACKED. FABRICATED DOUBLER REPAIR PER SRM 51-4-1. INSTALLED PER SRM 51-1-21. N/R 826.Aug 8, 1998 · N803DH · Doug DC873FSDR DHL9880320CFloor · crackedAT C CHECK, PANEL ON RACK NR 2 FLOOR PLATE, STA 25/45, DOUBLER CRACKED. REMOVED AND REPLACED DOUBLER PER SRM 51-1-4, 7 BY 3. N/R 821.Aug 8, 1998 · N803DH · Doug DC873FSDR DHL9880303CFloor · corrodedAT C CHECK, MAIN CARGO COMPT AFT LOWER FLOOR AREA AT STA 1700-1730 FLOOR PANELS DETERIORATED AND CORRODED UPPER AND LOWER SURFACES. FABRICATED REPAIR FOR ANGLE SUPPORT PER SRM 51-1-4, 2 BY 3FT, N/R 808.Aug 8, 1998 · N803DH · Doug DC873FSDR CALA9801405Floor · corrodedINSPECTION FOUND RT AFT LAV FIXED FLOOR CORRODED INCLUDING AROUND DUMP CHUTE AT BS 1129-1176, RBL 25-63. THE CORROSION WAS REMOVED. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-2, 51-40-5, AND 51-10-6.Aug 7, 1998 · N32725 · Boeing 727224SDR CALA9801408Floor · puncturedINSPECTION FOUND A HOLE IN FORWARD PIT FLOOR PANEL AT STA 640-720. THE DAMAGED AREA WAS CUT OUT. TWO DOUBLERS AND REPAIR FILLER WERE FABRICATED AND INSTALLED IAW SRM 53-10-7, 51-10-2, 51-30-2, AND MM 51-20-11.Aug 6, 1998 · N14788 · Boeing 727232SDR CALA9801407Floor · puncturedINSPECTION FOUND A PUNCTURE IN AFT CARGO FLOOR PANEL AT STA 950E. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-2, 53-10-7, 51-10-2, 51-30-2, AND MM 51-20-11.Aug 6, 1998 · N14788 · Boeing 727232SDR SWAA981638Floorboard · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORRODED SURFACE AND FLOORBOARD HOLES LEFT TRANSITION ANGLE AT BS 727E-947. REPAIRED PER BOEING SRM.Aug 5, 1998 · N301SW · Boeing 7373H4SDR P5CA9801219Floor · delaminatedLEVEL 1 CORROSION ON FLOOR PANEL UNDER LT UPPER DECK SLIDE CARRIAGE DELAMINATED AND MINOR CORROSION. FOUND MINOR SURFACE CORROSION, REMOVED IAW SRM 51-10-06 AND REPAIRED DELAMINATION IAW SRM 51-40-05.Aug 2, 1998 · N806FT · Boeing 747249FSDR CALA9801362Floor · crackedINSPECTION FOUND AFT CARGO FLOOR PANEL AT STA 756-935 CRACKED AND WORN IN SEVERAL PLACES. A NEW PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-21-0.Jul 29, 1998 · N15525 · Doug DC932SDR TWAA9812118Floor · crackedDURING OP 16 MAINT CHECK, FOUND RT CENTER CABIN FLOOR PANEL AT FS 465 TO 579 WITH 5 CRACKS AT U-CHANNELS ON BOTTOM SIDE, NR 39 PANEL. NEW PANEL FABRICATED PER SSRM 53-00-104.Jul 23, 1998 · N995Z · Doug DC932SDR CALA9801282Floor Panel · delaminatedINSPECTION FOUND FLOOR PANEL DELAMINATED AT STA 756 TO 680. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-05 AND 51-10-3.Jul 20, 1998 · N18544 · Doug DC932SDR CALA9801265Floor Panel · separatedINSPECTION FOUND FLOOR PANEL SKIN SEPARATING AT STA 579 TO 680. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-21-0, PAGE 11 AND 53-05, PAGE 122B.Jul 17, 1998 · N18544 · Doug DC932SDR CALA9801256Floor Panel · brokenINSPECTION FOUND FLOOR PANEL BROKEN AT STA 522 TO 579. THE FLOOR PANEL WAS REMOVED IAW MM 53-20-0. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-20-0 AND 53-21-0.Jul 15, 1998 · N18544 · Doug DC932SDR CALA9801252Floor Panel · corrodedINSPECTION FOUND FORWARD PIT FLOOR PANEL CORRODED AND DELAMINATED AT STA 313 TO 357. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW ECRA 2551-01010.Jul 15, 1998 · N18544 · Doug DC932SDR CALA9801246Floor Panel · delaminatedINSPECTION FOUND FORWARD PIT FLOOR PANEL DELAMINATED AT STA 218 TO 313. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW ECRA 2551-01010.Jul 14, 1998 · N18544 · Doug DC932SDR CALA9801245Floor Panel · crackedINSPECTION FOUND FORWARD CARGO PIT FLOOR PANEL CRACKED AT ST 427 TO 522. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW ECRA 2551-01010.Jul 14, 1998 · N18544 · Doug DC932SDR P5CA9801224Floor · crackedBULK CARGO BS2020 LBL 48 AND 52 FLOOR PANEL SUPT HAT SECTION CRACKED. REPAIRED PER SRM 51-40-03.Jul 12, 1998 · N852FT · Boeing 747122SDR CALA9801239Floor · corrodedINSPECTION FOUND CABIN FLOOR PANEL CORRODED FORWARD OF RT AFT LAV AT STA 945 TO 965, RBL 44. THE FLOOR PANEL WAS REMOVED AND THE CORRODED SECTIONS WERE CUT OUT. REPAIRS WERE FABRICATED AND INSTALLED IAW SRM 53-05, FIGURE 1, 51-10-3, AND 51-30-2. THE FLOOR PAJul 12, 1998 · N18544 · Doug DC932SDR CALA9801237Floor · corrodedINSPECTION FOUND FLOOR PANEL CORRODED AT STA 229 TO 294, BL 0. THE FLOOR PANEL WAS REMOVED AND A NEW PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-21-0, 53-10-4, 51-20-2, 51-10-3, AND 51-30-2.Jul 10, 1998 · N18544 · Doug DC932SDR TWAA9811902Floor Panel · crackedDURING OP 16 MAINTENANCE CHECK, FOUND FORWARD CABIN FLOOR PANEL NR 40 WITH HAT SECTIONS CRACKED IN SEVERAL PLACES. REPLACED CRACKED HAT SECTIONS IN FLOOR PANEL NR 40 PER SRM 53-00-104, PAGE 201 FIG 201. (M)Jul 8, 1998 · N995Z · Doug DC932SDR SWAA981321Floor · crackedDURING SCHEDULED D-CHECK, FOUND CRACKED FLOOR WEB AT BS 178, LBL 25 TO 29 WL 207. REPAIRED PER BOEING SRM.Jul 8, 1998 · N336SW · Boeing 7373H4SDR CALA9801206Floor · corrodedINSPECTION FOUND CABIN FLOOR PANEL CORRODED AND PUNCTURED AT STA 960-965, BL 0 TO RBL 21.5. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 51-70-1 AND 53-05, PAGE 122B.Jul 2, 1998 · N18544 · Doug DC932SDR P5CA9801134Floor · delaminatedCOCKPIT AREA, FLOOR PANEL UNDER F/E TABLE IS DELAMINATED. REPAIRED PER SRM 51-10-01 AND SRM 51-10-02.Jul 1, 1998 · N855FT · Boeing 747124SDR 98ZZZX2661Floorboard · damagedREAR FLOORBOARD BECAME BOWED FROM HEAVY USE. FLOOR IN CONTACT WITH MICROSWITCH AND ON FLAP MOTOR CAUSING INTERMITTENT OPERATION.Jul 1, 1998 · N101G · Cessna 310RSDR CKSA98364Floor · corrodedDURING ROUTINE CPCP INSPECTION, FOUND FLOOR HAS CORROSION BETWEEN STA 860 AND STA 880 RBL 98 BOTTOM SIDE. REMOVED FLOOR PANEL CORROSION FOUND TO BE OUT OF LIMITS IAW B747 SRM 53-20-00 FIG 2. MADE NEW FLOOR PANEL IAW B747 SRM 53-20-01. INSTALLED FLOOR PANEL Jun 30, 1998 · N625PL · Boeing 747132SDR P5CA9801070Floor · corrodedBULK CARGO FLOOR PANELS 1920 TO 2040 LT TO RT FOUND CORROSION ON LOWER EDGE AREA. CORROSION REMOVED AND REPROTECTED IAW SRM 51-10-01 AND 51-10-02.Jun 26, 1998 · N858FT · Boeing 747123SDR AU980778Floor Panel · cracked(AUS) FLOOR PAN LOCATED ON THE TOP OF THE RT MAIN LANDING GEAR BOX STRUCTURE AT STN 56.69 CONTAINED SEVERAL CRACKS (APPROXIMATELY SIX) UP TO 52.8 MM (2 INCHES) LONG BETWEEN THE RIVETS ON TOP OF THE BULKHEAD AT THE REAR OF THE CABIN SEATS. SUSPECT CAUSED BY HEAJun 25, 1998 · Cessna 152SDR CALA9801135Floor · corrodedINSPECTION FOUND FLOOR PANEL IN FORWARD PIT CORRODED AND DELAMINATED AT STA 378 TO 279. A NEW PANEL WAS FABRICATED AND INSTALLED IAW ECRA 2551-01010.Jun 17, 1998 · N12538 · Doug DC932SDR CALA9801118Floorboard · delaminatedINSPECTION FOUND CABIN FLOORBOARD NR 41 DELAMINATED AT LT SIDE FS 389-465. A NEW PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-05, 53-21-0, 51-30-2, 51-10-3, 51-70-2, AND 51-20-0.Jun 17, 1998 · N12538 · Doug DC932SDR CALA9801113Floorboard · corrodedINSPECTION FOUND CORROSION AROUND SCREW HOLES OF CABIN FLOORBOARD PANEL NR 44. A NEW PANEL WAS FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-21-0, AND 51-70-2.Jun 16, 1998 · N12538 · Doug DC932SDR CALA9801090Floorboard · splittingINSPECTION FOUND NR 48 FLOORBOARD SKIN SPLITTING AT FS 465 TO 579. SKIN AND FOUR HAT SECTIONS WERE FABRICATED AND INSTALLED IAW SRM 53-21-0 AND 51-70-2.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801089Floorboard · crackedINSPECTION FOUND LT FLOORBOARD PANEL BETWEEN STA 680 AND 756 CRACKED AT THE LT FORWARD NR 5 ATTACH HOLE. A NEW FLOOR PANEL WAS FABRICATED. TWO HAT SECTIONS WERE REMOVED, CLEANED, AND REBONDED TO NEW FLOOR PANEL IAW SRM 53-05, PAGE 1.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801088Floorboard · gougedINSPECTION FOUND FLOORBOARD PANEL NR 86 GOUGED AND CORRODED. A PANEL WAS FABRICATED AND INSTALLED IAW SRM 51-10-3, 53-05 PAGE 1, 51-20-0 AND 51-30-2.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801087Floorboard · crackedINSPECTION FOUND FLOORBOARD PANEL NR 79 CRACKED AT THE RT FORWARD EDGE. THE CRACK WAS STOP DRILLED, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-3, 53-01 PAGE 12-18.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801086Floorboard · crackedINSPECTION FOUND HAT SECTION OF 49 FLOORBOARD CRACKED AT BOTH ENDS. THE HAT SECTION WAS REMOVED AND A NEW SECTION WAS FABRICATED AND INSTALLED IAW SRM 53-21-0 AND 51-70-2.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801084Floorboard · crackedINSPECTION FOUND FLOORBOARD NR 70 CRACKED. A NEW FLOORBOARD WAS FABRICATED AND INSTALLED IAW SRM 53-05, PAGE 122B.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801075Floorboard · crackedINSPECTION FOUND CRACKS AT FORWARD AND AFT ENDS OF FLOORBOARD NR 45. THE FLOORBOARD WAS REPAIRED IAW SRM 53-01, PAGE 9.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801074Floorboard · crackedINSPECTION FOUND CRACKS AT THREE SCREW HOLES IN RT FLOORBOARD NR 41. A STRAP WAS FABRICATED AND INSTALLED ON FLOOR PANEL IAW SRM 51-10-2 AND 51-30-2.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801071Floorboard · crackedINSPECTION FOUND RT SIDE FLOORBOARD HAD FOUR CRACKS AT SCREW HOLES OF FS 756 AND THREE CRACKS AT SCREW HOLES OF FS 680. THE HAT SECTIONS WERE REMOVED, A NEW FLOOR PANEL WAS FABRICATED AND HAT SECTIONS WERE BONDED TO NEW PANEL IAW SRM 51-30-2, 51-10-2, 51-10-3Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801070Floorboard · crackedINSPECTION FOUND CABIN FLOORBOARD NR 45B FORWARD LEADING EDGE LIP CRACKED AND TORN. THE TORN AREA WAS ROUTED OUT. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-01, PAGE 122, FIGURE 4, 51-10-3 AND 51-10-4.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801069Floor · corrodedINSPECTION FOUND CABIN FLOOR PANEL NR 29 CORRODED ON UPPER AND LOWER SURFACES AT STA 237, BL 0 TO RBL 22. A NEW PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-05 AND 51-70-2.Jun 15, 1998 · N12538 · Doug DC932SDR CALA9801102Floorboard · delaminatedINSPECTION FOUND NR 40 FLOORBOARD DELAMINATED AT CENTER AISLE STA 389 TO 465. A NEW FLOORBOARD WAS FABRICATED AND INSTALLED IAW SRM 53-05, PAGE 122B.Jun 13, 1998 · N12538 · Doug DC932SDR CALA9801059Floorboard · dentedINSPECTION FOUND THREE DENTS WITH A CRACK IN FLOORBOARD PANEL NR 83. A NEW FLOORBOARD WAS FABRICATED AND INSTALLED IAW GMM 10-900-01, PAGE 1, SRM 51-70-1, 51-10-3, AND 53-05.Jun 13, 1998 · N12538 · Doug DC932SDR CALA9801101Floorpanel · crackedINSPECTION FOUND NR 42 LT CENTER FLOOR PANEL IN FORWARD PIT CRACKED AT FS 579 TO 680. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-21-0, 53-05, PAGE 1, AND 51-70-1.Jun 12, 1998 · N12538 · Doug DC932SDR CALA9801100Floorpanel · delaminatedINSPECTION FOUND FLOOR PANEL AT BS 365 TO 430 IN FORWARD PIT DELAMINATED. A NEW FLOOR PANEL WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND ECRA 2551-01010.Jun 12, 1998 · N12538 · Doug DC932SDR CALA9801099Floorboard · corrodedINSPECTION FOUND CORROSION ON NR 1 FLOORBOARD IN FORWARD PIT WITH DELAMINATION ON EDGES AT STA 218 TO 284. TWO HAT SECTIONS AND SIX NUT PLATE STRIPS WERE REMOVED. A FLOORBOARD WAS FABRICATED. THE FLOORBOARD, HAT SECTION, AND NUT PLATE STRIPS WERE INSTALLED Jun 12, 1998 · N12538 · Doug DC932
Back to JASC 5321