JASC 5340
Service difficulty reports · 22,407
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA202210242646Fitting · crackedCENTER WING BOX - INSPECTION OF REAR SPAR AND BOTTOM PANEL AT JUNCTION WITH FUSELAGE FR47 RH SIDE, FASTENER HOLE 165 FOUND CRACK SIGNAL REPAIRED THE CENTER WING BOX REAR SPAR AND BOTTOM PANEL AT JUNCTION WITH FUSELAGE FR47 RH SIDE CRACKED FASTENER HOLE 165SDR AALA202211048774Stringer Clip · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO COMPARTMENT FLOOR STRUCTURE STRINGER CLIP HAS CRACKS LOCATED AT STA 500I AND STR 26R. REMOVED AND REPLACED STRINGER CLIP PER SRM 51-40-02-0G.SDR SWAA2022111462915Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS400 LBL25. MARKED. / [01] REMOVED INTERCOSTAL ATTACH ANGLE AT FCB BS 400; LBL 25 PER SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED NEW ANGLE (CLIP) P/N 143A7502U155 PER SRM 51-40-05-0G-0 AND DWG 143A7505. REQUESDR SWAA2022111463086Attach Angle · corrodedCORROSION ON FWD SHIELD ATTACH ANGLE AT ACB BS767 RBL23. NO ALLOWABLE DAMAGE LIMITS IN SRM. WILL REPAIR BY REPACEMENT IAW SRM 51-10-02-0G-0 PARAGRAPH # 9. REMOVED FWD SHIELD ATTACH ANGLE AT ACB BS 767 RBL23 WL 156 IAW SRM 51-40-02. LOCATED AND DRILLED FWSDR AALA202210251009Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND RBL 15.04. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210259395Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND LBL 32.40. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210254860Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND RBL 32.40. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210258808Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND RBL 40.87. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210256605Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND RBL 6.14. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210256909Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND RBL 54.60. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210253669Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND LBL 54.60. REPLACED SHEAR FITTING PER EA 339611.SDR SWAA2022111561972Attach Angle · crackedRIGHT BS 663 UPPER ATTACH ANGLE IS CRACKED ON VAPOR BARRIER RBL 8 WL167.68. INSTALLED EWIS PROTECTION ON UPPER ATTACH ANGLE IAW AMM 20-60-07-913-801. REMOVED DAMAGED SECTION OF UPPER ATTACH ANGLE IAW SRM 57-10-10-2R-5. PERFORM OPEN HOLE HFEC INSPECTION FORSDR AALA202210254576Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND LBL 15.04. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210257021Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND LBL 40.87. REPLACED SHEAR FITTING PER EA 339611.SDR AALA202210250921Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR SHEAR FITTING LOCATED AT BS 540 AND LBL 6.14. REPLACED SHEAR FITTING PER EA 339611.SDR SWAA2022110759998Dome Nut · corrodedDOME NUT HAS CORROSION INSIDE OF HOLE AT AFT WET AREA STA. 986.5 RBL 43. / [01] REMOVED DOME NUT AT RBL 43 TO FOM PER SRM 51-40-02. ATTEMPTED TO REMOVE CORROSION FROM HOLE PER SRM 51-10-02. CORROSION IS STILL PRESENT IN HOLE. CONTACTED ENGINEERING FOR FURTHER SDR IXXA2022101403Stringer Clip · crackedSTRINGER CLIP CRACKEDSDR IXXA20221310Fitting · corrodedLOWER KEEL FITTING STA 1140 RIGHT WHEEL WELL REMOVED FOR REPLACEMENT BECAUSE REA REPAIR SHIFTING HOLE ATTACH POINTS.SDR AALA202212134840Stringer Clip · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION STRINGER CLIP LOCATED AT BS 500E AND S6R. REPLACED STRINGER CLIP PER SRM 51-40-02-0G.SDR SWAA2022102758316Bracket · brokenAFT CARGO BAY LAV TANK BULKHEAD LOWER BRACKET BROKEN BS867 LBL10 WL166 / [01] REMOVED AND REPLACED AFT CARGO BAY LAV TANK BULKHEAD LOWER BRACKET BS 867 LBL 10 WL 166 PER SRM 51-40-02-0G-0 AND DWG 149A8104;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] TASK CARD SDR SWIA202266714Bracket · damagedR/H AFT WINDSCREEN UPPER OTBD SHUTE BOLT BRACKET AT FRAME 84 HOLE ELONGATED (C-CHECK RO 10/31/2022) / REMOVED AND REPLACED R/H AFT WINDSCREEN UPPER OTBD SHUTE BOLT BRACKET AT FRAME 84 HOLE REF EMB SRM 51-40-08 AND RETORED SURFACE PROTECTION REF SRM 51-SDR SWIA202266713Brace · damagedR/H AFT WINDSCREEN UPPER INBD SHUTE BOLT BRACKET AT FRAME 84 HOLE ELONGATED (C-CHECK RO 10/31/2022) / REMOVED AND REPLACED RH AFT WINDSCREEN GROMMET AT FRME 84 PER ETD2022-170-032175. THIS TEMPORARY REPAIR IS VALID FOR 7500FC AS OF OCTOBER 20, 2022.SDR SWIA202266712Brace · elongatedL/H AFT WINDSCREEN UPPER OTBD SHUTE BOLT BRACKET AT FRAME 84 HOLE ELONGATED (C-CHECK RO 10/31/2022) / REMOVED AND REPLACED LH AFT WINDSCREEN UPPER OUTBD SHUTE BOLT BRACKET AT FRAME 84 REF SRM 51-40-08. APPLIED SURFACE PROTECTION AND CIC PROTECTION REFSDR SWIA202266711Bracket · damagedL/H AFT WINDSCREEN UPPER INBD SHUTE BOLT BRACKET AT FRAME 84 HOLE ELONGATED (C-CHECK RO 10/31/2022) / REMOVED AND REPLACED L/H AFT WINDSCREEN UPPER INBD SHUTE BOLT BRACKET AT FRAME 84 REF EMB SRM 51-40-08 AND RESTORED SURFACE PROTECTION REF SRM 51-23-0SDR FDEA202210062487Anchor Fitting · corroded: AFT ACCESSORY COMPARTMENT, LONGERON - 33 RIGHT TO LONGERON - 35 RIGHT, ATTACHMENT ANCHOR NUT SURROUNDING AREA FOUND WITH CORROSION. ANCHOR NUT AREA AT AFT ACCESSORY COMPARTMENT, LONGERON - 33 RIGHT TO LONGERON - 35 RIGHT, STATION 2144 TO STATION 2164 RESDR SWAA2022102455622Nut Plate · corrodedAFT CARGO NUT PLATE STRIP BS 773 LBL21-RBL20 HAS CORROSION IN AND AROUND NUT PLATE HOLES. / [01] OBTAINED NEW PART AND INSTALLED ON CARD TTG8Q00EH0SX IAW SRM 51-40-02.SDR IPXA2022110988010Fitting · crackedINSPECTION TYPE:SEG, EO A300-5310-46789-G CENTER FUSELAGE BASE FRMAE FITTING FRAME 46 R/H HAS A CRACK IN AREA 1.REPAIRED PER EO A300-5310-46789-G APPENDIX G.SDR IPXA2022110988008Fitting · crackedINSPECTION TYPE:SEGEO A300-5310-46789-G CENTER FUSELAGE BASE FRAME FITTING FRAME 46 L/H HAS A CRACK IN AREA 1.REPAIRED PER EO A300-5310-46789-G APPENDIX F.SDR IXXA2022101903Mount · damagedUPON REMOVAL OF DAMAGED 13R PDU FOUND PDU MOUNT STRUCTURE DAMAGED. FAS WO FS220047 NON ROUTINE 00354SDR FDEA202209302476Bracket · out of alignment#1 ACM INLET SCOOP MOUNTING BRACKETS, 3 EACH, OUT OF ALIGNMENT. REMOVED AND REPLACED 3 MOUNTING BRACKETS FOR #1 ACM INLET SCOOP REF SRM 51-31- 01-0G. MAJOR REPAIR.SDR SWAA2022101849293Shear Tie · corrodedCORROSION ON R/H EMERGENCY EXIT DOOR FWD LOWER SHEAR TIE AT RBL 68; RBL 72 WL 221 BS 616+1. / [01] CORROSION ON R/H EMERGENCY EXIT DOOR FWD LOWER SHEAR TIE AT RBL 68; RBL 72 WL 221 BS 616+1 FOUND OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM ; REPLACE PASDR SWAA2022101141778None · crackedBREAK PANEL IS CRACKED AT STA 540; BL0-LBL 25; WL 208. / [01] UPDATED TABLE;[02] REMOVED DAMAGED BREAK PANEL ASSY BS 540; BL 0 - LBL 25; WL 208 PER SRM 51-40-02-0G-0.;[03] LOCATED AND DRILLED NEW BREAK PANEL ASSY BS 540; BL 0 - LBL 25; WL 208 PER SRM 51-40-05-SDR SWAA2022101141779None · crackedBREAK PANEL IS CRACKED AT STA 540; BL0-RBL 25; WL 208. / [01] UPDATED TABLE;[02] REMOVED DAMAGED BREAK PANEL ASSY BS 540; BL 0 - RBL 25; WL 208 PER SRM 51-40-02-0G-0.;[03] LOCATED AND DRILLED NEW BREAK PANEL ASSY BS 540; BL 0 - RBL 25; WL 208 PER SRM 51-40-05-SDR SWAA2022101147474Strap · crackedCRACK ON STRAP LOCATED BS 767 AND BS 787; S- 25L AND S-25R AFT CARGO COMPARTMENT 2022-533428 / [01] REPLACED STRAP LOCATED BS 767 AND BS 787; S- 25L AND S-25R AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02;[02] CORRECTED STEP 1 REPLACED STRAP LOCATED BS 767 ASDR DALA2022092806367None · noneRDAF EXPIRATION ER/A 599331-14AD REV A INCLUDES INSTRUCTION FOR MODIFICATION OF THE MLGD HINGE AND ACTUATOR FITTINGS ON 3010. SEC III TRACKS LIMIT FOR RDAF EXPIRATION. AMOC/RDAF APPROVING AIRWORTHY CONFIGURATION MUST BE ACQUIRED PRIOR TO REACHING THIS LIMIT. RSDR AALA202211118333Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK WINDSHIELD FRAMING RIGHT HAND CONTINUITY FITTING CRACKED BETWEEN FR 1 AND FR 2 AT Y0. MAINTENANCE REPLACED THE CONTINUITY FITTING PER EA 339390.SDR DALA2022092806366None · noneAMOC AD 2015-02-14 ER/A 599331-14AD REV A INCLUDES INSTRUCTION FOR MODIFICATION OF THE MLGD HINGE AND ACTUATOR FITTINGS ON 3010 . SEC II TRACKS LIMIT FOR THE NEXT DUE AD 2015-02-14 INSPECTION. AMOC APPROVING TERMINATING ACTION MUST BE ACQUIRED PRIOR TO REACHINSDR SWAA2022102016124Web · corrodedR/H PRESSURE WEB SUPPORT CLIP AT STA 663 RBL 63 WL 202 HAS AREA OF CORROSION / [01] REMOVED CORROSION IAW SRM 51-10-02-0G-0; EVALUATED MATERIAL LOSS - ORIGINAL THICKNESS .063'; LOSS .007; REMINING .056'.<BR>TOOL# AAR29270 CAL DUE 12/09/22.;[02] NO ALLOWABLE MASDR SWAA2022102016126Web · delaminatedR/H PRESSURE WEB STA 663 TO 684.668 RBL 65 TO RBL 70 WL 202 HAS AREA OF DELAM ON FWD END / [01] VERIFIED NEW WEB P/N 144A7732U1 ATAG WN23125 IAW E/A 22-153-03009-WIP1 STEP 2.;[02] VERIFIED MATERIAL;[03] LOCATED AND DRILLED NEW WEB IAW SRM 51-40-05-0G-0 AND BOESDR SWAA2022100616063Fitting · crackedCRACK ON FITTING LOCATED BS 947.5 AND STR 26L AT AFT CARGO COMPARTMENT 2022-467006 / [01] TOOL USED: DIGITAL CALIPER; P/N:500-197-30;S/N:A21143495;DUE DATE:29-JUN-23.;[02] REPLACED FITTING AND FASTENERS LOCATED BS 947.5 AND STR 26L AT AFT CARGO COMPARTMENT IAWSDR V0XD20220915001Bracket · corrodedCORROSION ON LBL Y=479.0 BRACKET AFT OF LATERAL FLOOR BEAM: CORRECTIVE ACTION: FABBED NEW ANGLE REPAIR AND FILLER INSTALLED ON LBL Y=479.0 AFT OF LATERAL FLOOR BEAM IAW EMB 145 SRM 53-00-10 AND SRM 51-30-01SDR IPXA2022091386230Bracket · crackedINSPECTION TYPE:CFWD CARGO COMPT AT FR38.2 UPPER SUPPORT STRUCTURE 3EA BRACKETS CRACKEDREMOVED AND INSTALLED 3EA BRACKETS IAW-SRM 51-40-21SDR SWAA2022100552540Bracket · brokenAFT CARGO BAY LAV TANK BULKHEAD LOWER BRACKET IS BROKEN BS867 LBL10 WL166 / [01] REMOVED ACB LAV TANK LOWER BULKHEAD SUPPORT BRACKET BS867; LBL10; WL166 PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW ACB LAV TANK LOWER BULKHEAD SUPPORT BRACKET BS867; LBL10SDR SWAA2022101452066Fitting · corroded*CORROSION* FWD CABIN STA 312 LBL 56 WL 208.1 FLOOR FITTING IS CORRODED AT FASTENER HOLES. 124-011 / [01] INSTALLED EWIS PROTECTION AT FWD WET AREA;STA 312;LBL 56''.PER B 737-700 AMM 20-60-07.;[02] VERIFIED STEP 1.;[03] REMOVED CORROSION AT FWD WET AREA;FLOOR SDR SWAA2022101452079Fitting · corroded*CORROSION* FWD CABIN STA 344 LBL 59 WL 208.1 FLOOR FITTING IS CORRODED INSIDE FASTENER HOLES. 125015 124-015 / [01] INSTALLED EWIS PROTECTION AT FWD WET AREA;STA 344;LBL 59'';PER B 737-700 AMM 20-60-07.;[02] VERIFIED STEP 1.;[03] REMOVED CORROSION AT FWD WET SDR K11A2023033100202Seat Track · corrodedFUSELAGE FLOOR STRUCTURE - SEAT TRACK AT STA 420 RBL 26" (APPROX) HAS EVIDENCE OF CORROSION.SDR SWAA2022111551613Fitting · crackedDUE TO CRACK FINDING IN THE L/H BS 663 FRAME FITTING; THE R/H FRAME FITTING IS BEING REPLACED (PICKLE FORK) PN 144A2400-38. ASSY P/N 144A2400-36#B / [01] STARTED REMOVE FASTENERS RH FRAME STA 663 LH IAW B737-700 SRM 51-40-02;[02] VERIFIED ACTION 1;[03] REMOVEDSDR 2022F00464Mount · corrodedFWD SIDE OF LOWER WING PLANKS HAVE EXFOLIATION CORROSION AT BREAST PANEL MOUNTING FLANGES. FWD MID CABIN FS 261 - 348.SDR IXXA20220929001Attach Angle · crackedFWD ATTACH ANGLE AT PANEL 198JR IS CRACKED(RT FILLET AREA) REF AMES N/R 147534-0100-0281SDR SWAA2022091550733None · crackedCRACKED BREAK PANEL STA 540; BL0 TO RBL25; WL 207. / [01] REMOVED DAMAGED BREAK PANEL STA 540; BL 0-RBL 25;WL 207 PER SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED AND DEBURRED NEW BREAK PANEL STA 540; BL0 TO RBL25; WL 207; PER SRM 51-40-02-0G-0; SRM 51-40-05-0G
Back to JASC 5340