SDR SWIA202161520Not Reported · crackedPAX DOOR SUPPORT WHEEL AFT HINGE IS CRACKED. (C-CHECK RO 9/30/2021) REMOVED DAMAGE HINGE FITING AND INSTALLED A NEW SERVICABLE FITTING IAW CRJ 700 SRM 51-42-06-001-001-A01, 51-42-14-001-001-A01, 51-42-22-001-001-A01SDR SWIA2021091360894Mount · corrodedOPON REMOVAL OF GALLEY1 MOUNTING FEET FOUND TO BE CORRODED. (C-CHECK RO 9/8/2021) REMOVED AND REPLACED GALLEY # 1 MOUNT FITTING P/N: SH670-32149-3 REF. CRJ-900 SRM 51-42-21-001-001-A01 AND BOMBARDIER DWG# SH690-32120 REV. AL. CW 51-900-1002-SKYSDR SWIA202161469None · corroded*LEFT SEAT TRACK HAS MULTIPLE AREAS OF CORROSION FS840.00 €“ FS991.00. (MARKED) (C-CHECK RO 9/27/2021) INSTALLED NEW SEAT TRACK P/N SH670-37420-5 ATLBL9 FS840.00 - FS991.00 REF. CRJ 700 AMM 53-00-49-400-801-A03SDR SWIA202161467None · corroded*RIGHT SEAT TRACK HAS MULTIPLE AREAS OF CORROSION FS840.00 €“ FS991.00. (MARKED) (C-CHECK RO 9/27/2021) REPLACED DAMAGED RH SEAT TRACK BETWEEN FS 840-991 WITH NEW SEAT TRACK IAW CRJ-700 AMM 53-00-49-000-801-A03SDR SWIA2021073059812Mount · corroded*FLOOR STRUCTURE: G1 GALLEY MOUNT TOP PLATE AT APPROX FS 286 / RBL 38 HAS EVIDENCE OF CORROSION. (C-CHECK RO 7/27/2021) REMOVED AND REPLACED GALLEY PLATE P/N: 601R38669-65. FLOOR STRUCTURE G1 GALLEY AT APPROX FS 286 / RBL 38. REF: DWG# 601R38669, REV -NSDR SWIA2021073059810Mount · corroded*FLOOR STRUCTURE: ENTRANCE CABINET MOUNT TOP PLATE AT APPROX FS 308 / LBL 20 HAS EVIDENCE OF CORROSION. (C-CHECK RO 7/27/2021) REPLACED ENTRANCE CABINET MOUNT TOP PLATE AT FS308.00 & LBL 20. REF CRJ200 DWG# 601R38670 REV -T & CRJ200 SRM 51-42-13. COMPLISDR SWIA2021073059809Mount · corroded*FLOOR STRUCTURE: G1 GALLEY MOUNT TOP PLATE AT APPROX FS 317 / RBL 5 HAS EVIDENCE OF CORROSION. (C-CHECK RO 7/27/2021) REPLACED GALLEY 1 MOUNT TOP PLATE AT APPROX FS 317 / RBL 5. REF CRJ200 SRM 51-42-13 AND DWG# 601R38669 REV -N. COMPLIED WITH SKYWEST TSDR SWAA2021050763359Mount · corrodedFLOOR STRUCTURE AT RIGHT AFT LAV AFT INBD MOUNT FITTING HAS CORRSION / REMOVED R/H AFT INBD LAV MOUNT FOR EVALUATION; REMOVED AND REPLACED DAMAGED INTERCOSTAL STA. 947 - 967 RBL 24.5 P/N 147A5660-3; AND FORMED ANGLE STA 927-947 RBL 24.5 P/N 147A5430-8; NO DAMASDR SWAA2021050763357Mount · corrodedFLOOR STRUCUTR AT LEFT AFT LAV AFT INBD MOUNT FITTING HAS CORROSION / REMOVED L/H AFT LAV ; AFT INBD MOUNT FOR EVALUATION ; REPLACED DAMAGED FLOOR SUPPORT ANKLE P/N 147A5430-7 AND DAMAGE INTERCOSTAL STA. 947.967 LBL 24.5 P/N 147A5660-3 PER SRM 51-40-02. INSTALSDR SWAA2021050763358Mount · corrodedFLOOR STRUCTURE AT RIGHT AFT LAV AFT OUTBD MOUNT FITTING HAS CORROSION / REPAIRED PER SRM 53-70-51-ZR-5 AND EA 21-153-01050.STA 947.5 FLOOR BEAM PART #147A5504 PER SRM 53-70-51-OI-1; ITEM 1; FIG4; TABLE 4SDR SWAA2021050763360Mount · corrodedAFT GALLEY RIGHT FWD MOUNT STRUCTURE HAS CORROSION /SDR R61A2021041600334Bracket · corrodedFWD LAV AFT O/B HOLD DOWN BRACKET AND HARDWARE CORRODED. FWD LAV AFT O/B HOLD DOWN BRACKET AND HARDWARE REMOVEDC AND REPLACED IAW AMM 20-10-01 AND 51-40-08SDR R61A2020121200860Bracket · crackedWHILE IN HEAVY CHECK LOWER RT RADAR MOUNT BRACKET CRACKED. REPLACED BRACKET IAW SRM 51-40-08.SDR R61A2020121200859Bracket · crackedWHILE IN HEAVY CHECK LOWER LT RADAR MOUNT BRACKET CRACKED. REPLACED IAW SRM 51-40-08.SDR R61A2020121200858Bracket · crackedWHILE IN HEAVY CHECK MAJOR REPAIR UPPER RT RADAR MOUNT BRACKET CRACKED. REPLACED IAW SRM 51-40-08.SDR SWIA202054532Mount · corrodedFWD STOWAGE AFT OUTBOARD FLOOR MOUNT CORRODED. C-CHECK RO 12/05/2020. BLENDED OUT CORROSION ON THE WARDROBE FLOOR DOUBLER AFT OUTBOARD LOCATION, REF CRJ 200 SRM. FOUND OUT OF LIMITS, REF CRJ 200 SRM. INSTALLED A NEW FLOOR DOUBLER, REF DRAWING AND CRJ 200 SSDR SWIA202054531Mount · corrodedFWD STOWAGE AFT INBOARD FLOOR MOUNT CORRODED. C-CHECK RO 12/05/2020. BLENDED OUT CORROSION ON AFT INBOARD FLOOR MOUNT DOUBLER FOR THE WARDROBE, REF CRJ 200 SRM. FOUND OUT OF LIMITS, REF CRJ 200 SRM. INSTALLED A NEW FLOOR MOUNT DOUBLER, REF CRJ 200 SRM AND SDR TIPR2020121544353Mount · corrodedLEFT MAIN WHEEL WELL, FIRE BOTTLE MOUNT ASSEMBLY IS CORRODED AT BOTTLE ATTACH FASTENERS, REPLACED MOUNT.SDR SWAA2021072822325Mount · corrodedAFT CABIN L/H LAV; AFT INBOARD HARD POINT FITTING HAS VARIOUS AREA OF SURFACE CORROSION PRESENT (MARKED) / INSTALLED REPAIR PER EA 20-153-02001 AND SRM 53-70-51-2R-5. SEE INDIVIDUAL SIGNOFFS FOR ALL WORK ACCOMPLISHED. SEE SAM 326: A1184515SDR AALA202010309025Mount · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON LAVATORY MOUNT AT STA 950 AND LBL 50, MEASURING L=1.0 IN, W=1.0 IN, D=0.04 IN. REPLACED MOUNT WITH NEW, IAW SRM 51-40-02.SDR SWAA2021081617155Mount · corroded'E' LAV AFT OUTBOARD TIE DOWN FITTING HAS CORROSION AT STA 950 RBL 50' MARKED / REMOVED AFT OUTBD LAV MOUNT FOR EVALUATION (NO CORROSION NOTED ON LAV MOUNT); CORROSION LIMITED TO INTERCOASTAL RBL 50 STA. 947 TO 967 P/N 147A5660-22 OUT OF LIMITS PER SRM 53-70-5SDR SWIA202053203Mount · damagedGALLEY NR 2 INBOARD FWD AND AFT SEAT TRACK FLOOR MOUNTS ARE DAMAGED, CRACKED IN HALF. C-CHECK RO 10/9/2020. REMOVED 2 EA DAMAGED FLOOR MOUNT FITTINGS FOR GALLEY NR 2, REF CRJ-900 SRM. ORDERED AND RECEIVED NEW FITTING P/N: CDSP1900-501. INSTALLED 2 EA NEW GSDR SWIA202008252059Mount · corrodedGALLEY 2 FLOOR MOUNT ATTACHED TO SEAT TRACK HAS EVIDENCE OF CORROSION. REPLACED 2 EA GALLEY2 FLOOR MOUNT FITTINGS WITH NEW. REF CRJ-700 SRM.SDR SWIA202008252036Attach Fitting · corrodedFLOOR SUPPORT STRUCTURE AT THE GALLEY 1 MOUNT BRACKETS: BOTH FWD LOCATIONS HAVE CORROSION AROUND AND IN THE BOLT HOLES. REMOVED AND REPLACED NEW FITTINGS AT GALLEY 1 MOUNT BRACKETS IAW SRM.SDR SWIA2020081151733Mount · corrodedGALLEY MOUNT PADS, FWD AND AFT, INBOARD OF RBL 9.00 ARE CORRODED AROUND BOLT HOLES. FWD GALLEY MOUNT PAD WAS FOUND TO HAVE NO CORROSION .AFT PAD WAS REMOVED AND REPLACED IAW SRM.SDR MASA20200625042Hinge · damaged(C-CHECK) PAX DOOR HINGE DAMAGED. R & R FUSELAGE SIDE PASSENGER DOOR HINGE PN SH670-31876-13S.SDR UIEA2020061001269Structure · corrodedCORROSION - FOUND M/D CGO UPPER CHORD CORROSION AT STA 1268, 1297, 1328, 1395-1396, 1435, 1477, LBL 11.(<P>REMOVE DAMAGED PART IAW SRM 51-40-02 REV 88. INSTALLED NEW PART IAW SRM 51-40-02 REV 88 AND BOEING DWG 65B24600 SH 18 REV B AND SH 19 REV C AND SH 20 REVSDR SWIA20205060527Mount Fitting · corroded*FLOOR SUPPORT STRUCTURE - FWD INBD GALLEY FLOOR MOUNT FITTING, HAS CORROSION ON THE UPPER SURFACE AT THE MOUNT BOLT HOLE. (C-CHECK) RO 5/4/2020 REPLACED CORRODED FWD I/B GALLEY MOUNT FITTING WITH NEW P/N: SH670-32149-3, REF CRJ200 SRM.SDR SWAA2020042731870Mount · damagedG1 GALLEY HAS DAMAGED INSERTS FOR COVER PLATES ON BOTH OUTBOARD MOUNT BOLT LOCATIONS. / REPLACED FLOOR HARD POINT MOUNT ON G1 GALLEY IAW-CMM 25-31-03 AND AMM 25-00-00-300-801 STEP K VA1051 ATAGSDR AALA2020032549029Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR RIGHT HAND AFT GALLEY MOUNT AT BS 1718 AND RBL 40. REPLACED MOUNT PER SRM 51-10-02.SDR SWIA2020040149850Mount · crackedAFT LAVATORY, FLOOR MOUNTS, BOTH (2EA) AFT MOUNTS ARE VISIBLY CRACKED AT THE BOLT HOLES (C-CHECK) RO:3/29/2020REMOVED 2 EA CRACKED AFT LAV, FLOOR MOUNTS AND INSTALLED 2 EA NEW AFT LAV FLOOR MOUNTS REF. CRJ700 SRM.SDR AALA2020032549020Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN LAVATORY "K" AFT INBOARD MOUNT AT BS 1640 AND LBL 30. REPLACED MOUNT PER SRM 51-40-02.SDR SWIA2020033049680Mount · corrodedGALLEY INBD AFT MOUNT CORRODED (C-CHECK) RO:3/26/2020REMOVED AND INSTALLED GALLEY INBD AFT MOUNT IAW CMM CRJ 200 SECTION 2C.SDR SWIA2020031649278Mount · corroded*PASSENGER CABIN FLOOR SUPPORT STRUCTURE I/B FORWARD AND AFT GALLEY MOUNTS HAVE CORROSION. (C-CHECK) RO 3/13/2020 REMOVED CORROSION & EVALUATED REWORKED AREAS. FWD INBD GALLEY MOUNT WITHIN LIMITS AFTER REWORK. AFT INBD GALLEY MOUNT REPLACED. FINISH RESTORESDR SWIA2020031649277Mount · corroded*PASSENGER CABIN FLOOR SUPPORT STRUCTURE O/B-I/B FORWARD AND AFT WARDROBE MOUNTS HAVE CORROSION. (C-CHECK) RO 3/13/2020 REMOVED AND REPLACED WITH NEW PASSENGER CABIN FLOOR SUPPORT STRUCTURE AFT I/B & AFT O/B WARDROBE MOUNTS . REF: CRJ-200 SRM AND BOMBARDISDR A6WA2020011347099Support Bracket · crackedBRAKE PRESSURE TRANSDUCER SUPPORT BRACKET CRACKED AT FS530, LH MLG WHEEL WELL. AIRCRAFT REMOVED FROM SERVICE REMOVED AND REPLACED BRAKE PRESSURE TRANSDUCER SUPPORT BRACKET AT FS530 IAW CRJ200 SRM 51-42-06SDR A6WA2019123047084Bracket · crackedBRAKE PRESURE TRANSDUCER BRACKET IN R/H MLG WHEEL WELL AT FS529 IS CRACKED AIRCRAFT REMOVED FROM SERVICE REMOVED AND REPLACED BRAKE PRESSURE TRANSDUCER BRACKET IAW CRJ200 SRM 51-42-06SDR SWIA2019122747136Mount · corrodedTWO GALLEY NR 2 FLOOR MOUNTS ATTACHED TO SEAT TRACK CORRODED. REPLACED THE FLOOR MOUNTS ON SEAT TRACK IAW SRM.SDR SCNA20190907120Mount Fitting · corrodedLAV E AFT RT OUTBD FLOOR MOUNT FITTING IS CORRODED. REMOVED AND REPLACED DAMAGED FLOOR MOUNT FITTING ON LAV E RT OUTBOARD FLOOR.SDR AALA201909049073Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LAVATORY MOUNT FROM FR 330 TO FR 335, LBL20. REPLACED LAVATORY MOUNT PER SRM 51-00-01.SDR AALA201909049071Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON GALLEY MOUNT AT FR 1713, RBL-51. REPLACED GALLEY MOUNT PER 51-00-05.SDR AALA201909049066Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND FORWARD GALLEY MOUNT AT FR 1687, RBL-51. REPLACED MOUNT PER 51-00-05.SDR AALA201908309014Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON GALLEY TIE DOWN AT FR 1680. REPLACED GALLEY TIE DOWN PER 51-00-05.SDR AALA201908309013Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON GALLEY TIE DOWN AT FR 1720, RBL-53. REPLACED GALLEY TIE DOWN PER 51-00-05.SDR AALA201908309011Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON GALLEY TIE DOWN AT FR 1720, LBL55. REPLACED GALLEY TIE DOWN PER 51-00-05.SDR AALA201908309010Tie Down · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON GALLEY TIE DOWN AT FR 1720, RBL-53. REPLACED GALLEY TIE DOWN PER 51-00-05.SDR AALA201908309009Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LAVATORY MOUNT AT FR 1640, RBL-54. REPLACED LAVATORY MOUNT PER 51-00-05.SDR AALA201908309007Mount · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LAVATORY MOUNT AT FR 1640, RBL-24. REPLACED LAVATORY MOUNT PER 51-00-05.SDR IPXA2019070544119Fitting · brokenINSPECTION TYPE:12YR MAIN CABIN FLOOR FITTING HAS A BROKEN LUG AT FR 50, -Y2462. REMOVED, FABRICATED AND REPLACED BROKEN MAIN CABIN FLOOR STRUCTURE EQUIPMENT FITTING ASSEMBLY AT FR 50, -Y2462 USING ALTERNATE MATERIAL IAW EA 300-5320-01-A7822 REV. IR AND EO A30SDR AALA201905159014Mount Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND SIDE GALLEY MOUNT FITTING AT BS 1720. REPLACED FITTING PER SRM 51-10-02.
Back to JASC 5345