What it covers
For reports pertaining to the main frame, spar, or rib structure on the nacelles or pylons.
Service difficulty reports · 1,453
Reports filed under 5411, newest first.
| 1995 | 9 |
|---|---|
| 1996 | 17 |
| 1997 | 34 |
| 1998 | 37 |
| 1999 | 39 |
| 2000 | 14 |
| 2001 | 34 |
| 2002 | 70 |
| 2003 | 83 |
| 2004 | 55 |
| 2005 | 40 |
| 2006 | 90 |
| 2007 | 70 |
| 2008 | 89 |
| 2009 | 60 |
| 2010 | 99 |
| 2011 | 119 |
| 2012 | 67 |
| 2013 | 38 |
| 2014 | 43 |
| 2015 | 18 |
| 2016 | 16 |
| 2017 | 29 |
| 2018 | 27 |
| 2019 | 28 |
| 2020 | 25 |
| 2021 | 22 |
| 2022 | 32 |
| 2023 | 29 |
| 2024 | 37 |
| 2025 | 37 |
| 2026 | 46 |
SDR UIEA2026092800919Spar · damagedNR 3 PYLON UPPER SPAR WEB SKIN SUSPECT CRACK AT NAC STA 300. CRACKED NR 3 PYLON UPPER SPAR WEB SKIN R & R IAW SRM 51-40-02-0G-0 REV. 107, DWG. 311U2130. SHT. 6, REV. B; REPAIR CARRIED OUT IAW EN 3684-26, REV. 0. REPAIR CLASSIFIED AS "MAJOR" CATEGORIZED AS "CASDR UIEA2026083100830Frame · chafedNUMBER 1 ENG LT CORE COWL NR 2 FRAME MID AREA ANGLE FWD, CHAFED. FRAME REPAIRED IAW SRM 54-42-02-2R-2, REPAIR 2, & EA-1971A296, REV 0. NO FURTHER DEFECTS NOTED.SDR HNAA2026092300899Spar · crackedRELEVANT INDICATION NOTED DURING HFEC OF LT PYLON SPAR 2 UPPER FLANGE AFT FASTENER HOLE. REPAIRED LT PYLON SPAR 2 UPPER FLANGE AFT FASTENER HOLE TO 1ST OVERSIZE BUSHING IAW SB 145-54-0008 AND EO1-54-26-0423.
See all 1,453 reports