JASC 5753
Service difficulty reports · 31,513
Reports filed under 5753 · Trailing Edge Flaps, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5753' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5753' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201437200Vane · chafedRIGHT INBD FLAP VANE L/E SKIN CHAFED AT OTBD END. C-CHECK, REPAIRED RT INBD FLAP VANE L/E SKIN AT OTBD END IAW REO.SDR SWIA201437199Vane · chafedRIGHT INBD FLAP VANE L/E SKIN CHAFED AT CENTER. C-CHECK, REPAIRED RT FLAP VANE L/E SKIN AT CENTER IAW REO.SDR SWIA201437140Skin · gougedLEFT INBD FLAP INSIDE PANEL 584AB GOUGE IN SKIN IN BETWEEN ACTUATOR FITTING. C-CHECK, BLENDED GOUGE SMOOTH IAW REO.SDR SWIA201437139Skin · gougedLEFT INBD FLAP INSIDE PANEL 584CB GOUGE IN SKIN IN BETWEEN ACTUATOR FITTING. C-CHECK, BLENDED GOUGE SMOOTH IAW REO.SDR SWAA2014041627156Skin · delaminatedLEFT WING INBD FORE FLAP UPPER SURFACE DELAMINATED. REPAIRED FORE FLAP IAW SRM.SDR SWAA2014041627155Fitting · looseLEFT WING OTBD FORE FLAP NR 2 CARRIAGE FITTING LOOSE. SECURED FITTING IAW MM.SDR FXGA201404071421Skin · damagedFLAP SKINS REPLACEMENT BETWEEN STATION 64 & 148. REPLACE PUNCTURED & DENTED LOWER FLAP SKINS LOCATED BEHIND THE RT MLG. REMOVE DAMAGED LOWER SKINS BETWEEN STATION 64 & 148, TE CLOSE OUT PIECE BETWEEN STATION 64 & 97. MANUFACTURE NEW SKINS & CLOSE OUT PIECESDR IPXA2014050582858Skin · gougedINSPECTION TYPE:4C, LT WING INBD FLAP CENTER VANE TRACK CUTOUT GOUGED ON INBD AND OTBD SIDES, FWD AND AFT ACCOMPLISHED REPAIR ON LT WING INBD FLAP CENTER VANE CUTOUT SKIN AND RIB ASSY, INBD AND OTBD SIDES, IAW EA 011-5753-01-A5298, REV I/R AND EO 5750-54246-A.SDR SWIA201437215Tube · gougedRIGHT INBD FLAP, INBD FLAP VANE CENTER ACTUATOR TUBE ASSY HAS A GOUGE ON THE BOTTOM SIDE. C-CHECK, BLENDED GOUGED AREA ON RT INBD FLAP, INBD FLAP VANE CENTER ACTUATOR TUBE ASSY IAW REO.SDR SWIA201437214Tube · gougedRT INBD FLAP, INBD FLAP VANE CENTER ACTUATOR TUBE ASSY HAS A GOUGE ON THE BOTTOM SIDE. C-CHECK, BLENDED GOUGED AREA OF RT INBD FLAP, INBD FLAP VANE CENTER ACTUATOR TUBE ASSY IAW REO.SDR SWIA201437213Tube · gougedLEFT INBD FLAP, THE CENTER FLAP ACTUATOR TUBE HAS A GOUGE ON THE BOTTOM SIDE. C-CHECK, BLENDED GOUGED AREA ON LT INBD FLAP, CENTER ACTUATOR TUBE ASSY IAW REO.SDR SWAA2014041427096Bearing · brokenLEFT WING NR 2 A FRAME FLAP TRACK CARRIAGE BEARING BROKEN. R & R BEARING IAW CMM.SDR UIEA2014040700140Skin Panel · gougedFOUR EACH GOUGES ON OTBD FLAP AFT FLAP UPPER SKIN PANEL. R & R PANEL IAW B747-400 SRM 51-40-02.SDR SWAA2014060928830Fairing · crackedLEFT WING FLAP CTR HINGE AFT FAIRING CRACKED. REPAIRED FAIRING IAW SRM.SDR IPXA2014042582771Skin · damaged3C INSPECTION, RT WING INNER FLAP UPPER SKIN AT RIB 1C, AFT OF FRONT SPAR GOUGED AND CRACKED. REPAIRED FLAP SKIN IAW STASA EA 300-5750-01-A5279-IR AND EO A300-5750-54171-A.SDR SWAA2014040826931Skin · delaminatedLEFT WING OTBD AFT FLAP LOWER SURFACE DELAMINATED AT INBD SIDE. R & R AFT FLAP IAW MM.SDR SWAA2014052328289Angle · crackedRIGHT WW INBD SIDE OF INBD FLAP TRACK CARRIAGE ANGLE CRACKED. R & R ANGLE IAW SRM & DWG.SDR SWIA201437226Vane · chafedLT INBD FLAP VANE L/E CHAFED, OTBD AREA. C-CHECK, REPAIRED LT INBD FLAP VANE L/E OTBD AREA IAW REO.SDR SWIA201437225Vane · chafedRT FLAP VANE L/E CHAFED, INBD AREA. C-CHECK, REPAIRED RT FLAP VANE L/E INBD AREA IAW REO.SDR SWIA201437224Vane · chafedRIGHT FLAP VANE L/E CHAFED, ID AREA BEYOND LIMITS. C-CHECK, REPLACED IAW SRM.SDR SWIA201437221Vane · chafedLT INBD FLAP VANE MID AREA L/E CHAFED BEYOND LIMITS. C-CHECK, REPLACED LT INBD FLAP AND VANE IAW SRM.SDR SWIA201437220Vane · chafedRT FLAP VANE L/E MID AREA IS CHAFED BEYOND LIMITS. C-CHECK, REPLACED RT INBD FLAP VANE L/E MIDDLE AREA SKIN IAW SRM.SDR SWIA201437219Vane · chafedRIGHT FLAP VANE L/E OTBD AREA CHAFED AND REQUIRES REPLACEMENT. C-CHECK, REPLACED RT INBD FLAP VANE L/E OTBD SKIN IAW SRM.SDR SWAA2014041427077Skin · delaminatedLEFT WING AFT FLAP INBD LOWER SURFACE DELAMINATED. REPAIRED AFT FLAP IAW SRM.SDR REXA2014041400060Hinge Fitting · damagedLEFT OTBD FLAP AFT HINGE LUG FITTING AT FLS234.25 GOUGED & HAS OVERSIZED HOLES, OTBD LUG 0.4680 WITH REMAINING THICKNESS 0.218 INCHES, INBD LUG 0.4540 WITH REMAINING THICKNESS 0.203 INCHES. REPAIRED IAW REO 601R-57-53-1001.SDR SWIA201437227Vane · chafedLT INBD FLAP VANE, INBD L/E CHAFED. C-CHECK, REPAIRED LT INBD FLAP VANE, INBD L/E IAW REO.SDR SWIA201437141Vane · chafedRIGHT INBD FLAP VANE L/E CENTER CAP CHAFED BEYOND PERMANENT LIMITS. C-CHECK, REPLACED RT INBD FLAP VANE L/E CENTER CAP IAW SRM.SDR FDEA201404030641Skin · dentedLEFT WING INBD FLAP UPPER SURFACE FOUND DENTED AT STATION XIFH 289. REPAIRED IAW SRM 57-00-01 FIGURE 201 REPAIR 1 REVISION 55.SDR IPXA2014042582762Skin · tornDURING S2CP INSPECTION, LEFT OTBD AFT FLAP HAS A TWO INCH TEAR IN UPPER SURFACE EIGHT INCHES OTBD OF INBD EDGE AND FOURTEEN INCHES FWD OF T/E. FOUND WITHIN LIMITS IAW SRM 57-53-01-2R-1,TABLE 11.2.SDR SWIA201437142Vane · chafedRT WING INBD FLAP VANE CHAFED ON INBD L/E. C-CHECK, BLENDED RT WING INBD FLAP VANE CHAFE ON INBD L/E IAW REO.SDR SWIA201437117Vane · chafedLEFT INBD FLAP VANE L/E CHAFED AT OTBD END OF VANE. C-CHECK, REPLACED LT INBD FLAP VANE L/E OTBD CAP IAW SRM.SDR SWIA201437116Skin · chafedLEFT INBD FLAP VANE L/E CHAFED AT MIDDLE OF VANE. C-CHECK, REPLACED THE LT INBD FLAP VANE CENTER L/E SKIN IAW SRM.SDR SWIA201437115Vane · chafedLEFT INBD FLAP VANE L/E CHAFED AT INBD END OF VANE. C-CHECK, REPAIRED IAW REO AND SRM.SDR A6WA201441356Skin · chafedRIGHT INBD FLAP VANE EDGE INBD & CTR STOP CONTACTS CHAFED. R & R THE RT INBD FLAP VANE INBD LE WITH NEW SERVICEABLE LE SKIN IAW SRM 51-42-131-25-16.SDR R61A201404010512Support · corrodedDURING HEAVY CHECK, LT WING FLAP TRACK SUPPORT 2, 3, 4 FWD ATTACH POINTS HARDWARE IS CORRODED. MX R & R LT WING FLAP TRACK SUPPORT 2, 3, 4 FWD ATTACH POINTS HARDWARE IAW AMM 57-54-21, PN MS14145L8 NUT.SDR FDEA201404010612Spar · damagedELONGATED FASTENER HOLE AT RT INBD MAIN FLAP AFT SPAR & DOUBLER, 24 INCHES FROM OTBD END. FOUND OUT OF LIMITS, REPAIRED IAW EA F-5750-T0305818.SDR WX0A071903Skin · gougedLEFT OTBD FLAP OTBD FIXED VLV GAP GOUGED. REMOVED DAMAGED SKIN, FABRICATED REPAIR DOUBLER & FILLER & INSTALLED REPAIR PARTS IAW SRM 57-03.SDR SWIA201437148Vane · chafedRT WING INBD FLAP VANE CHAFED ON OTBD L/E. C-CHECK, R & R WITH NEW RT WING INBD FLAP VANE OTBD FLAP VANE SKIN IAW SRM.SDR DALA14020121814Fairing · delaminatedRIGHT WING INBD FWD FLAP OTBD NOSE FAIRING FOUND DELAMINATED. PERFORMED A COMPOSITE HOT BOND REPAIRED IAW SRM 57-53-01. REPAIR 1, FIG 201, TABLE 1, 51-70-05, PAR 5A (1) AND REF HX PROCESS CARD.SDR SPUY201403310035Fitting · wornRT WING OTBD FLAP FAIRING AFT FITTING WORN.SDR SWIA201437087Skin · chafedLEFT INBD FLAP PANEL 584GB IS CHAFED. C-CHECK, REPLACED FLAP PANEL IAW SRM..SDR REXA201403000338Flap System · cloggedFLAPS FAILED CAUTION MESSAGE, COMPLIED WITH PA AD27-052N. SNOW & SLUSH WERE CONTRIBUTING FACTOR TO FLAP FAIL EVENT. PERFORMED TROUBLESHOOTING IAW FIM REV 45, IAW AD 2009-06-12 PARAGRAPH H 6 I. COMPLETED CLEANUP OF CONTAMINATION OF SAND & OTHER CONTAMINATIOSDR SWAA2014033126619Flap · delaminatedLEFT WING OTBD TE FLAP DELAMINATED. R & R FLAP IAW MM.SDR IPXA2014033182461Skin · dentedRT WING INBD MID FLAP HAS TWO DENTS ON LWR SURFACE OTBD END. COMPLETED MAJOR REPAIR OF RT WING INBD MID FLAP IAW EOB747-5750-53923-A.SDR SWIA201437972Skin · wornPANEL 584ET ON LT INBD FLAP VANE IS WORN BEYOND ALLOWABLE LIMITS. C-CHECK, REPLACED PANEL 584ET.SDR DALA14020070130Skin · damagedFOUND RT INBD T/E FLAP PUNCTURED AND GOUGED ON TOP SURFACE. DAMAGE LOCATED UNDER OTBD SECTION OF NR 7 SPOILER. TIME LIMITED REPAIR IAW ERA 524625-14.SDR SWAA2014033126678Fairing · crackedLEFT WING TE FLAP NR 3 AFT FAIRING FWD OTBD CORNER CRACKED AT EDGE. REPAIRED FAIRING IAW EA.SDR C77A20140328020Flap Track · wornRT FLAP NR 1 INBD FLAP TRACK, PN 170-39310-005, HAS WIDTH REDUCTION WEAR OF .002 INCHES & TRACK THICKNESS REDUCTION WEAR OF .028 INCHES. BOTH AREAS ARE OUT OF LIMITS IAW E175 57-52-03. BLENDED WORN AREAS IAW SRM PART II 51-10-03 ON WORK ORDER 740147-642 IAWSDR C77A20140328019Flap Track · wornRT FLAP NR 1 OTBD FLAP TRACK, PN 170-39310-004, HAS WIDTH REDUCTION OF .015 INCHES, OUT OF LIMITS IAW E175 SRM 57-52-03. BLENDED WORN AREAS IAW SRM PART II 51-10-03 ON WORK ORDER 740147-640 IAW ETD 2011-170 01072E & EA E175-57-188 2 REV IR WORK ORDER 1419937.SDR C77A20140328018Flap Track · wornRT FLAP NR 2 INBD FLAP TRACK, PN 170-39313-004, HAS ROLLER TRACK THICKNESS REDUCTION OF .024 INCHES, OUT OF LIMITS IAW E175 SRM 57-52-03. BLENDED WORN AREAS IAW SRM PART II 51-10-03 ON WORK ORDER 740147-636 IAW ETD 2011-170 01072E & EA E175-57-188 2 REV IR WO
Back to JASC 5753