What it covers
For reports indicating a problem with wiring specific to the Powerplant System.
Service difficulty reports · 32
Reports filed under 7197, newest first.
| 1996 | 1 |
|---|---|
| 1997 | 1 |
| 2001 | 2 |
| 2003 | 3 |
| 2006 | 1 |
| 2008 | 1 |
| 2012 | 1 |
| 2013 | 2 |
| 2014 | 3 |
| 2015 | 3 |
| 2016 | 3 |
| 2017 | 3 |
| 2018 | 1 |
| 2019 | 4 |
| 2020 | 3 |
SDR AALA2020060549001Wire Harness · chafedAIRCRAFT IN BASE MAINTENANCE - CHAFING WIRE (CONNECTOR 4012VCA) HARNESS, NR 2 ENGINE FAN CASE, FORWARD UPPER POSITION. REPAIRED WIRING, AND PROPERLY ROUTED HARNESS IN NR 2 ENGINE FAN CASE FORWARD UPPER POSITION PER AMM TASK 70-71-22-0001-13.SDR HALA2020032800079Terminal · brokenAIR DIVERSION - R ENG SYS FAIL. // INSPECTED #2 ENG TGT HARNESS AND FOUND TERMINAL T1040-2 LEG BROKEN. REMOVED AND REPLACED PER 71-52-01. OPS CK PENDING. RAN ENGINES FOR 4 MINUTES -- NO FAULTS NOTED ( AMM 71-00-11 ). OK FOR SERVICE.SDR ASAA2020011431849Wire Harness · chafedWHILE PERFORMING GVI INSP ON NR 2 ENG FOUND MW0311 HARNESS CHAFFED THRU. REQ REPLACEMENT. GROUNDED - YES. REMOVED AND INSTALLED NEW MW0311 HARNESS. PERFORMED HARNESS TEST REF AMM 71-51-03 STEP H. ALL TESTS PASSED.
See all 32 reports