SDR N3XR2018121700305Valve · failedDURING CLIMB TO 8,000 FEET POWER DECREASED , UN-COMMANDED, FROM 92% TO 70%. TROUBLESHOOTING REVEALED THE ELECTRIC CHANGE OVER VALVE, P/N-E4A-41-300-801 WAS DEFECTIVE. THAT PART WAS REPLACED AND ALL OPERATIONAL CHECKS SHOWED PROPER OPERATION.SDR N3XR2018121700309Valve · failedON TAKEOFF ROLL, THE POWER WAS LOW. THE TAKE OFF WAS ABORTED. THE ELECTRIC CHANGE OVER VALVE, P/N-E4A-41-300-801, WAS REPLACED AND ALL GROUND PERFORMANCE TESTS INDICATED NORMALLY.SDR CA180907011Clamp · cracked(CAN) DURING ANNUAL INSPECTION AS WELL AS IN CONJUNCTION WITH AD 2000-01-16, THE V-BAND CLAMP THAT ATTACHES THE WASTEGATE EXHAUST ELBOW TO THE EXHAUST HEADER ASSY WAS FOUND CRACKED. (TC# 20180907011)