SDR TRBA20130115001Wire Harness · inoperativeTHE CREW REPORTED AFTER TAKEOFF, WERE UNABLE TO BRING LANDING GEAR UP. UNABLE TO MOVE GEAR HANDLE FROM DOWN POSITION. CREW DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. ACFT LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. R & R RT MLG UPPER HARNESSDR TRBA20121226001Power Supply · failedFWD RT EMERGENCY FLOOD LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT POWER SUPPLY 43WL.SDR TRBA20121224001Bulb · burned outRIGHT FORWARD EMERGENCY EXIT FLOOD LIGHT INOPERATIVE. REPLACED BULB.SDR TRBA20121223001Light · unknownEMERGENCY EXIT FLOOD LIGHT INOPERATIVE. OPS CHECKED GOOD.SDR TRBA20121221001Wire · brokenCABIN ENTRANCE EMERGENCY FOOD LIGHT INOPERATIVE. REPAIRED WIRES AT LIGHT ASSY.SDR TRBA20121218001Wire Harness · damagedDURING POST FLIGHT, THE CREW FOUND THE SERVICE DOOR EXIT SIGN (LOWER) LIGHT VERY DIM. THE ACFT WAS REMOVED FROM SERVICE. REPAIRED WIRE AT SERVICE DOOR EXIT SIGN IAW MM 20-27-13. OPS TEST SATISFACTORY IAW MM 33-50-00, OPT 10000. THE ACFT WAS RETURNED TO SERSDR TRBA20121216001Fuel Nozzle · leakingAFTER PARKING, THE GROUND CREW INFORMED THE CREW OF A LOT OF FUEL LEAKING FROM THE BOTTOM OF NR 2 ENGINE. FUEL WAS LEAKING WITH ENGINE RUNNING AT IDLE AND PUDDLE OF FUEL PRESENT UNDER ENGINE. THE ACFT WAS REMOVED FROM SERVICE. R & R FUEL NOZZLE NR 1 & NR 2 OSDR TRBA20121214002Control Unit · unserviceableTHE CREW REPORTED THE EMERGENCY BATTERY CHARGE CONTACTOR FAULT LIGHT CAME ON. WHEN RESET ALL ELECTRICAL EQUIPMENTS IN THE COKPIT STARTED TO FLICKER. THE ACFT WAS REMOVED FROM SERVICE. R & R BPCU. THE OPS TEST WAS SATISFACTORY JIC 24-46-83. THE ACFT WAS RETSDR TRBA20121214001Gcu · inoperativeTHE CREW REPORTED THE DC SERVICE/UTLILITY BUSS FAULT LIGHT CAME ON ALONG WITH MULTIPLE FAILURES. THE CREW ELECTED TO RETURN TO DEPARTURE. THE ACFT LANDED WITHOUT INCIDENT AND WAS REMOVED FROM SERVICE. R & R RT ENGINE DC GCU AND DC BPCU IAW JIC 24-32-81, RAISDR MTNA201212130001Master Cylinder · leakingON LANDING FOR FLIGHT 7126 THE LEFT BRAKE ON THE FIRST OFFICERS SIDE DID NOT WORK. THE MASTER CYLINDER WAS FOUND TO BE BAD. THE MASTER CYLINDER WAS REPLACED IAW ATR72 M/M JIC 32-42-13 RAI 10000 AND CHECKED GOOD IAW ATR72 M/M JIC 32-42-00 OPT 10000.SDR MTNA121120120001Elevator · obstructedDURING INITIAL CLIMBOUT OF REPOSITION FLIGHT 7559 MSN-CID, MADE A PRECAUTIONARY AIR TURNBACK INTO MSN DUE TO ABNORMAL PITCH FORCES. INSPECTION OF AIRCRAFT FOUND ICE ON THE RIGHT ELEVATOR. REMOVED ICE AND PERFORMED VISUAL INSPECTION OF ELEVATOR TRIM IAW ATR72SDR TRBA20121210001Light · inoperativeTHE CREW REPORTED THE PASSENGER DOOR EMERGENCY EXIT LIGHT WAS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE PASSENGER DOOR EMERGENCY EXIT FLOOD LIGHT ASSY IAW ATR JIC 33-51-24 RAI 10000. THE OPS TEST WAS SATISFACTORY. THE ACFT WAS RETURNED TO SESDR TRBA20121206001Switch · missingTHE CREW REPORTED THE EMERGENCY AUDIO CANCEL SWITCH IS MISSING TOGGLE SWITCH; IS STILL SAFETY WIRED. THE ACFT WAS REMOVED FROM SERVICE. R & R THE EMERGENCY AUDIO CANCEL SWITCH 12WW IAW STANDARD PRACTICES MM CAP 20-27-13 . THE OPS TEST IAW JIC 31-50-00-10000SDR TRBA20121105001Lamp · inoperativeTHE CREW REPORTED THE EMERGENCY EXIT FWD LIGHT IN PASSENGER ENTRY DOOR INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. R & R LAMP IAW 33-50-00. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121205002Lens · brokenDURING MX INSPECTION, FOUND GALLEY FLOOR EMERGENCY LIGHT COVER BROKEN. THE ACFT WAS REMOVED FROM SERVICE. R & R THE GALLEY EMERGENCY LIGHT ASSY IAW JIC 33-50-00. OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121201001Tire · failedTHE CREW REPORTED THAT UPON LANDING THE OUTER LT MAIN TIRE WAS BLOWN OUT. THE ACFT WAS REMOVED FROM SERVICE. R & R THE LT OTBD AND INBD MAIN WHEEL ASSY IAW EX-123732-RAI-10000. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121130001Power Supply · unserviceableDURING MX INSPECTION, FOUND HALF THE LIGHTS OF FOWARD AISLE EVACUATION PATH LIGHTS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE FWD EMERGENCY LIGHT POWER SUPPLY 43WL AND CLEANED FLOOR PROXIMITY ESCAPE PATH STRIP LIGHT CONNECTOR 55WL(B) IAW JIC SDR TRBA20121129001Power Supply · inoperativeDURING MX INSPECTION FOUND THE EMERGENCY FLOOR LIGHT, FORWARD SECTION INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R THE EMERGENCY LIGHT POWER SUPPLY IAW MM 33-51-21. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.SDR TRBA20121127002Skin · corrodedDURING MX INSPECTION, FOUND CORROSION AT RT WING BOTTOM T/E BETWEEN RIB 6 AND 10. ACFT REMOVED FROM SERVICE. INSTALLED RT WING T/E RIB 8-10 PANEL JIC 53-93-00 RAI-10000. ACFT RETURNED TO SERVICE.SDR TRBA20121127001Bulb · looseTHE CREW REPORTED THE EMERGENCY EXIT LIGHT IN STAIRS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. REPOSITIONED LIGHT BULB ON EMERGENCY EXIT LIGHT STAIRS. THE OPS CHECK WAS OK REF JIC 33-50-00, THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126010Fastener · corrodedDURING MX INSPECTION, FOUND THE RT WING FASTENERS AT T/E BETWEEN RIB 8-13 WITH CORROSION. ACFT REMOVED FROM SERVICE. INSTALLED RT WING T/E RIB 8-10 PANEL JIC 53-93-00 RAI-10000. ACFT RETURNED TO SERVICE.SDR TRBA20121126009Hinge · corrodedDURING MX INSP, FOUND THE T/E ACCESS PANEL HINGE CORRODED. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT T/E ACCESS PANEL HINGE IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126008Access Panel · corrodedDURING MX INSPECTION, FOUND CORROSION ON THE RT T/E ACCESS PANEL HINGE NEAR RIB 5-6. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING T/E ACCESS PANEL HINGE NEAR RIB 5-6. NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNED TO SERSDR TRBA20121126007Skin · corrodedDURING MX INSPECTION, FOUND CORROSION AT THE RT WING L/E BETWEEN RIB 4-5. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING L/E BETWEEN RIB 4-5 NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126006Drain Valve · corrodedDURING MX INSP FOUND THE RT WING INBD AFT WATER DRAIN VALVE WITH CORROSION. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING INBD AFT WATER DRAIN VALVE NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126005Pump · corrodedDURING MX INS FOUND THE RT WING ELECTRIC FUEL PUMP WITH CORROSION AROUND FASTENERS (BOLT). THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING ELECTRIC FUEL PUMP AROUND FASTENER (BOLT) NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNEDSDR TRBA20121126004Rib · corrodedDURING MX INSP FOUND CORROSION AROUND FASTENER AT LT WING T/E NEAR RIB 8 AREA. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING T/E FASTENER NEAR RIB 8 AREA IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126003Rib · corrodedDURING MX INSP FOUND CORROSION SPOT AT LT WING NEAR RIB 6 CENTER AREA. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING NEAR RIB 6 CENTER AREA IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126002Drain Valve · corrodedDURING MX INSP FOUND THE LT WING INBD WATER DRAIN VALVE BOTH WITH CORROSION. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING INBD WATER DRAIN VALVE IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126001Pump · corrodedDURING MX INSPECTION, FOUND THE LT WING ELECTRIC FUEL PUMP WITH CORROSION AROUND FASTENERS (BOLT). THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING ELECTRIC FUEL PUMP IAW SRM 51-21-42. NO MATERIAL REMOVED.SDR TRBA20121116001Lens · crackedFLIGHT 4847, CREW REPORTED THE SERVICE DOOR EMERGECNY GROUND FLOOD LIGHT LENS CRACKED AND WAS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R SERVICE DOOR GROUND FLOOD LIGHT IAW JIC 33-50-00. THE OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR MTNA1115120001Adc · faultyDURING TAKEOFF ROLL OF FLIGHT 7499 CRW-MEM, THE PILOTS AIRSPEED AND ALTIMETER FLAGS APPEARED. THE FLIGHT CREW ABORTED THE TAKEOFF AND RETURNED TO THE GATE. AFTER TROUBLESHOOTING THE MECHANIC REPLACED THE DADC IAW ATR72 JIC 34-11-81 THE SYSTEM CHECKED GOOD ANSDR TRBA20121115003Handle · inoperativeTHE CREW REPORTED THE EMERGENCY ESCAPE HANDLE WAS BROKEN. THE ACFT WAS REMOVED FROM SERVICE. EMERGENCY ESCAPE HANDLE MISSING SCREW INSTALLED IAW MM 52-22-10. THE AFT WAS RETURNED TO SERVICE.SDR TRBA20121115001Cover · missingON FLIGHT 4836, THE CREW REPORTED THE EMERGENCY LIGHT FLOOR LIGHT IN FRONT OF GALLEY CART WAS MISSING A COVER. THE ACFT WAS REMOVED FROM SERVICE. REPOSITIONED EMERGENCY LIGHT COVER ON GALLEY AREA IAW 335000. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121112001Cover · looseCREW REPORTED THE AFT FLOOR EMERGENCY LIGHT COVER IN FRONT OF THE GALLEY LOOSE. ACFT REMOVED FROM SERVICE. RESECURED AFT FLOOR EMERGENCY LIGHT COVER AND TESTED IAW ATR JIC 33-50-00-OPT-10000. TESTED SATIFACTORY. ACFT RETURNED TO SERVICE.SDR TRBA20121110001Light · looseTHE F/A REPORTED THE EMERGENCY EXIT LIGHTS FLOOR STRIP BY THE GALLEY WAS LOOSE. THE ACFT WAS REMOVED FROM SERVICE. REPLACED LIGHTED FLOOR PROXIMITY STRIP 163 WL IAW AMM 33-50-00. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR MTNA201211060001Master Cylinder · defectiveDURING TAXI OUT FOR FLIGHT 8126 MIA-KIN THE PILOT REPORTED THE LEFT BRAKE WAS INOPERATIVE. THE PILOT RETURNED THE AIRCRAFT BACK TO THE RAMP. THE FLIGHT WAS CANCELLED. THE BRAKE MASTER CYLINDER WAS REPLACED IAW ATR72 JIC 32-42-13 RAI-10000. THE SYSTEM CHECKSDR CA121116006Probe · failed(CAN) DURING INITIAL CLIMB AFTER T/O, THE CREW FELT A YAW FOLLOWED BY LT ENGINE UPTRIM INDICATION AND RT ENGINE AUTOFEATHER. EMERGENCY WAS DECLARED AND THE ACFT RETURNED TO THE DEPARTURE POINT WHERE AN UNEVENTFUL LANDING WAS PERFORMED. POST FLIGHT TROUBLESHOSDR TRBA20121121001Lamp · inoperativeTHE CREW REPORTED THE EMERGENCY EXIT FORWARD LIGHT IN PASSENGER ENTRY DOOR INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. LAMPED IAW 33-50-00. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121103001Bulb · inoperativeDURING MX INSPECTION, FOUND THE EMERGENCY EXIT FLOOR LIGHT PASSENGER ENTERY DOOR INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R BULB IAW JIC 33-50-00. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.SDR TRBA20121026001Torque Sensor · inoperativeCREW REPORTED THAT ON THE TAKEOFF ROLL, THE ANALOG PORTION OF NR 1 TORQUE GAUGE WENT TO ZERO. DIGITAL PORTION NORMAL. ACFT REMOVED FROM SERVICE. R & R LT ENGINE TORQUE SENSOR IAW 72-01-60 AND LT ENGINE AFU IAW 72-01-10. PERFORMED OPS CHECK IAW EX-055007-CSSDR TRBA20121024002Cover · missingTHE CREW REPORTED THE SERVICE DOOR EMERGENCY SIGN WAS MISSING COVER. THE ACFT WAS REMOVED FROM SERVICE. RESECURED SERVICE DOOR EMERGENCY SIGN COVER AND OPERATIONALY TESTED IAW JIC 33-50-OPT-10000. TESTED SATISFACTORY. THE ACFT WAS RETURN TO SERVICE.SDR TRBA20121024001Flashlight · inoperativeTHE CREW REPORTED THE NR 2 F/A FLASHLIGHT WAS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE NR 2 F/A FLASHLIGHT IAW MM 25-60-00. THE OPS CHECKED WAS GOOD. THE ACFT WAS RETURN TO SERVICE.SDR TRBA20121022001Light · inoperativeTHE CREW REPORTED THE LIGHT AT THE BOTTOM OF THE STEPS WAS INOPERATIVE. ACFT WAS REMOVED FROM SERVICE. ADJUSTED LIGHT ON PASSENGER DOOR IAW JIC33-50-00. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121021001Battery Pack · unserviceableTHE CREW REPORTED THE EMERGENCY EXIT LIGHTS REMAINED ON WITH THE SWITCH ON THE ARM POSITION (FIRST HALF REMAINED ON). THE ACFT WAS REMOVED FROM SERVICE. R & R THE EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK 43WL. PERFORMED OPS TEST IAW JIC 33-51-21-RAI-100SDR TRBA20121020001Channel · corrodedDURING MX INSPECTION, FOUND THE TAIL CONE NUTPLATE GANG LT AND RT CHANNELS TO HAVE CORROSION BEYOND LIMITS. THE ACFT WAS REMOVED FROM SERVICE. REPLACED DAMAGED SECTIONS OF LT AND RT TAIL CONE NUTPLATE GANG CHANNELS IAW MM 53-91-30, SRM 53-91-24 AND EO E2-530SDR TRBA20121019001Valve · inoperativeDURING MX INSPECTION, FOUND ODOR OF OIL IN THE ACFT. R & R P2.5/P3 VALVE ASSY ON LT ENGINE IAW MM-72-30-00 (COMPRESSOR SECTION), ADDED TOTAL OF (3) WASHERS TO SHAFT.SDR TRBA20121018001Channel · corrodedDURING B INSPECTION, FOUND THE TAIL CONE INTERNAL LT HORIZONTAL GANG CHANNEL HAS EXFOLIATING CORROSION ABOUT 20" FROM TAIL CONE LENS ASSY. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED TAIL CONE IAW JIC 53-91-24. OPS CHECKED GOOD. ACFT RETURNED TO SERVICESDR TRBA20121017006Skin · separatedDURING MX INSPECTION FOUND THE LT SPOILER PANEL HAS SEPARATION AND CORROSION ON THE UPPER T/E. ACFT REMOVED FROM SERVICE. INSTALLED SPOILER ASSY IAW JIC 57-71-00. ACFT RETURNED TO SERVICE.SDR TRBA20121017004Rod · failedDURING MX INSPECTION, FOUND THE RT ELEVATOR TRIM TAB CONTROL ROD FAILED SPECIAL DETAILED INSPECTION. FOUND FLAKED INTERNAL PROTECTIVE FINISH AND TRACES OF CORROSION. R & R THE RT ELEVATOR TRIM TAB CONTROL ROD IAW JIC 27-31-41.
Back to Aerospatiale ATR 72-212