Aerospatiale ATR 72-212
Service difficulty reports · 4,441
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ATR72212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ATR72212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TRBA2011018A/C Pack · odorNR 2 PACK FAULTED IN FLIGHT. RE-SET ON GROUND THEN NOTICED A BURNING ODOR BUT NO FAULT LIGHT. DE-SELECTED PACK AND ODOR WENT AWAY. PERFORMED OPT CHECK IAW 21-51-00 CK 10020-001. NO FAULT OR ODOR NOTICED AT THIS TIME. ACFT RETURN TO SERVICE.SDR COEA2011021425805Web · crackedHEAVY CK / COE / MAJOR REPAIR: RIGHT WING LEADING EDGE PANEL 614 INNER TWO WEBS (P/N S57412153201 AND S57412166201) ONE CRACK EACH UPPER INBOARD AREA. REPAIRED PER ATR72 SRI AND SRAS DO/TS-420/11-6253 ISSUE A DATED 2/07/11.SDR COEA2011021424805Crease Beam · corrodedHEAVY CK / COE / LEVEL 2 CORROSION: UPPER AND LOWER SURFACES OF RT CREASE BEAM WEB FR 14-15 HAS MANY AREAS OF CORROSION. REMOVED RT CREASE BEAM WEB AND REPLACE WITH OEM PART PER ATR72 SRM.SDR TRBA2011019Lamp · burned outLOWER EXIT SIGN ON SERVICE DOOR NEEDS RELAMPED. RELAMPED LOWER EXIT SIGN IAW MM33-00-00. OPS CHECK GOOD. ACFT RETURN TO SERVICESDR COEA2011021123805Seat Track · corrodedHEAVY CK / COE / LEVEL 2 CORROSION: SEAT TRACKS BETWEEN FR 29-36 LEFT I/B HAS NUMEROUS AREAS OF CORROSION (LENGTH 4.330", WIDTH .023", DEPTH .042"). REMOVED AND REPLACED LEFT I/B SEAT TRACK WITH NEW OEM PART PER ATR72 SRM.SDR TRBA2011017Unknown · fumesAFTER NR 1 ENGINE START AND THE NR 1 BLEED SELECTED ON. STRANGE FUMES ENTERED COCKPIT WITH A FAINT BLUE HAZE. BLEED WAS SELECTED OFF AND ODOR DISIPATED. RAN BOTH ENG IAW 72-00-00 CHECKED TEMP AND FULL COLD AND HOT IAW 21-61-00 COULD NOT DUPLICATE.SDR COEA2011021122805Seat Track · corrodedHEAVY CK / COE / LEVEL 2 CORROSION: RIGHT I/B SEAT TRACKS BETWEEN FRAME 29-36 HAS NUMEROUS AREAS OF CORROSION (LENGTH 5.2", WIDTH .030", DEPTH .0323"). REMOVED OLD SEAT TRACK, DRILLED FASTENER HOLES IN NEW SEAT TRACK, TREATED, PAINTED AND INSTALLED NEW OEM SSDR COEA2011021121805Structure · corrodedHEAVY CK / COE / LEVEL 2 CORROSION / MAJOR REPAIR: AFT LT PAX/CREW DOOR FWD DOOR PAN SIDE PRESSING HAS 3 AREAS OF CORROSION, MID DOOR MARKED AS VIEWED WITH DOOR OPEN (LENGTH 2.9" & 1.85", WIDTH .95" & 1.15", DEPTH .006" & .006"). REPAIR PER STRUCTURAL REPAIRSDR COEA2011021020805Bulkhead · corrodedHEAVY CK / COE / LEVEL 2 CORROSION: LOWER AFT BULKHEAD HAS AREAS OF LEVEL 2 CORROSION. (LOWER 6 O'CLOCK AREA DEEPEST CORROSION AREA NOMINAL .040 INCH). REMOVED SKIN DOUBLER AND REPLACED WITH OEM DOUBLER.SDR TRBACPCP2011003Hinge Fitting · corrodedRT WING SPOILER OTBD HINGE FITTING SHOWS INTERGRANULAR CORROSION. R & R SPOILER OTBD HINGE FITTING IAW SRM: 57-70-00.SDR TRBACPCP2011002Support Bracket · corrodedRT WING SPOILER BRACKET SUPPORT SHOWS INTERGRANULAR CORROSION. R & R RT WING SPOILER BRACKET SUPPORT IAW SRM:57-70-00.SDR CA110214009Engine · power lossUNCOMMANDED AUTOFEATHER WHILE ON APPROACH AT APPROX. FL40, THE CREW NOTED A MOMENTARY DROP IN POWER TURBINE SPEED AND TORQUE. THE ENGINE POWER RECOVERED TO NORMAL SETTINGS 12 SECONDS LATER WITH NO PILOT INPUT. AN UNEVENTFUL LANDING FOLLOWED. MULTIPLE FAULTS SDR TRBA2011015Control Unit · erraticDURING DESCENT NR 1 ENGINE LOST POWER FOR 10 SECONDS OR LESS. ENG WARNING ON CAP NR 1 TORQUE INDICATE WENT TO ZERO & ACW GEN WENT OFF LINE. POWER RETURNED TO NORMAL. PERFORMEDED OPS CK IAW EX-055007-CS-20000-001. COULD NOT DUPLICATE THE PROBLEM. OPS CHECKED SDR TRBA2011013Controller · failed(EMERGENCY DECLARED) DURING CRUISE FLIGHT, NR 2 ENGINE PROPELLER FEATHERED AND GOT EEC NR 2 FAULT, IAW CREW DEBRIF, CREW SHUTDOWN NR 2 ENGINE PRECAUTIONARY IAW MFG PROCEDURES. NR 2 ENG PCU REPLACED IAW MM 61-22-00, OPT CHECK AND LEAK CHECK GOOD, ALSO REFERSDR COEA2011012819805Skin · dentedNR 2 HEAVY CHECK / COE / MAJOR REPAIR: LT SIDE PITOT AREA HAS SKIN DAMAGE BETWEEM FR 3 (STA 3536-STA 3480) AND FR 6 (STA 4204). REPAIR PER STRUCTURAL REPAIR INSTRUCTIONS FROM ATR.SDR TRBA2011011Light · inoperativeON POST FLIGHT INSP, F/O DISCOVERED CABIN DOOR EMERGENCY LIGHT INOP (THE ONE BUILT INTO STEP). REPLACED PAX ENTRANCE DOOR EMERGENCY FLOOD LIGHT IAW 33-51-00. OPS CK OK.SDR COEA2011012018805Skin · corrodedHEAVY CK / COE / MAJOR REPAIR / LEVEL 2 CORROSION: LT HORIZONTAL STABILIZER LOWER AFT SKIN TO REAR SPAR CHORD SEAM HAS 3 VOIDS IN SEALANT WITH LEVEL 2 CORROSION. (24" IB OF RIB 3, 34" IB OF RIB 3 AND 14" IB OF RIB 3) REPAIR PER STRUCTURAL REPAIR INSTRUCTIONSDR COEA2011012017805Crease Beam · corrodedHEAVY CK / COE / LEVEL 2 CORROSION: RT CREASE BEAM INNER CHORD SPLICE AT FR 13 HAS LEVEL 2 CORROSION. (LENGTH 2.25", WIDTH 1.25" AND DEPTH .080") MINOR REPAIR IAW ATR72 SKRM 53-13-14 AND SRM.SDR COEA2010012016805Crease Beam · corrodedHEAVY CHECK / COE / MAJOR REPAIR / LEVEL 2 CORROSION: RT CREASE BEAM INNER CHORD IS CORRODED IN AREAS FROM FR 13 TO SPLICE AFT OF FR 15. REPAIR PER STRUCTURAL REPAIR INSTRUCTIONS FROM ATR.SDR COEA2011011815805Floorbeam · damagedHEAVY CK / COE / MAJOR REPAIR: MISDRILLED HOLE ON FLOORBEAM 29 AT RT O/B SEAT TRACK CENTER HOLE (BL -0- 37.82") WAITING FOR STRUCTURAL REPAIR INSTRUCTIONS FROM ATR.SDR COEA2011011814805Bulkhead · damagedHEAVY CHECK / COE/ MAJOR REPAIR: TOOLING DAMAGE ON AFT PRESSURE BULKHEAD RT SIDE 8 O'CLOCK POSITION (RT BL -0- 31.5 INCHE FR 44). BLENDED OUT TOOLING MARKS ON AFT PRESSURE BULKHEAD. WAITING FOR STRUCTURAL REPAIR INSTRUCTIONS FROM ATR.SDR COEA2011011713805Skin · scratchedHEAVY CHECK/ COE/ MAJOR REPAIR: EXTERIOR FUSELAGE UPPER SKIN UNDER ADF ANTENNA IS SCRATCHED. BLENDED OUT PER SRM; WAITING FOR STRUCTURAL REPAIR INSTRUCTIONS FROM ATR.SDR COEA2011011212805Frame · corrodedHEAVY CHECK COE / MAJOR REPAIR/ LEVEL 2 CORROSION: FOUND EVIDENCE OF LEVEL 2 CORROSION AT FRAME 41 BETWEEN STRINGER 16R AND 17R. BLENDED CORROSION ON FR 41 BETWEEN STR 16-17R, OUT OF LIMITS. AWATING SRI FROM ATR.SDR COEA2011011111805Rub Strip · wornHEAVY CHECK COE / MAJOR REPAIR: AFT UPPER SPAR BETWEEN RIB 4L - 4R HAS RUB STRIP WORN OUT OF LIMITS. MAJOR REPAIR PER ATR SRI LT WING AFT UPPER SPAR STRIP REPAIRED.SDR COEA2011011110805Rub Strip · wornHEAVY CHECK COE / MAJOR REPAIR: UPPER FWD SPAR BETWEEN RIB 4L - 4R HAS RUB STRIP THAT IS WORN. REPAIR PER ATR SRI UPPER FWD SPAR STRIP SLAT AT CLIP LOCATIONS 9R & 10R LOCATED WITHIN RIB 4L & 4R.SDR COEA2011011109805Skin Panel · damagedHEAVY CK COE / MAJOR REPAIR: RT VERTICAL SKIN AT VOR ANTENNA LOCATION HAD DAMAGE TO SKIN AND BAD NUT PLATES. MAJOR REPAIR PER ATR SRI.SDR COEA2011011108805Skin Panel · damagedHEAVY CK COE / MAJOR REPAIR: LT VERTICAL SKIN AT VOR ANTENNA LOCATON HAS DAMAGE TO SKIN AND BAD NUT PLATES. MAJOR REPAIR PER ATR SRI.SDR COEA2011011107805Crease Beam · corrodedHEAVY CK COE/MAJOR REPAIR / LEVEL 2 CORROSION: LT CREASE BEAM BETWEEN FRAME 39 & 40 FOUND TO HAVE LEVEL 2 CORROSION. (LENGTH 9", WIDTH 2.5", DEPTH .012"). BLENDED CORROSION ON LT CREASE BEAM OUTER CHORD BETWEEN FR 39 - 40. WAITING FOR REPAIR INSTRUCTIONS FRSDR COEA2011011106805Frame · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: LEVEL 2 CORROSION BETWEEN 21R & 21L AT FRAME 39 (BEHIND TAIL SKID STRUCTURE)(LENGTH 4", WIDTH 1", DEPTH .080"). REPAIR PER ATR72 SRM.SDR COEA2011011105805Intercostal · corrodedHEAVY CK COE / LEVEL 2 CORROSION: LEVEL 2 CORROSION ON INTERCOSTAL AT STRINGER 21L BETWEEN FRAMES 40 & 41 (NEXT TO LAV DRAIN) (LENGTH 5", WIDTH 1", DEPTH .013"). REMOVE AND REPLACE INTERCOSTAL PER ATR72 SRM.SDR COEA2011011104805Frame · corrodedHEAVY CK COE / MAJOR REPAIR/LEVEL 2 CORROSION: LEVEL 2 CORROSION FOUND ON FRAME 41 BETWEEN STRINGER 16R AND 17R (LENGTH 5", WIDTH 1.125", DEPTH .006"). BLENDED CORROSION ON FR41 BETWEEN STR 16-17R. WAITING FOR REPAIR INSTRUCTIONS FOR A SRI FROM ATR.SDR COEA2011011103805Frame · corrodedHEAVY CK COE LEVEL 2 CORROSION: FOUND LEVEL 2 CORROSION AT FRAME 28D STR 20L - 21L. (LENGTH: 6", WIDTH 1", DEPTH .040"). REMOVED FRAME 28D AND SPLICE. INSTALLED FRAME SEGMENT 28D FROM FACTORY SPLICE - SPLICE STR 17R AND 17L.SDR COEA2011010701807Connector · contaminatedLEFT ENGINE FIRE WARNING SOUNDED APPROXIMATELY 4 MILES FROM LANDING IN PSC. DISCHARGED BOTH FIRE BOTTLES, DECLARED EMERGENCY AND LANDED WITHOUT INCIDENT. NO VISUAL SIGN OF SMOKE OR FIRE. FOUND WATER IN LOOP CONNECTORS CAUSING FALSE WARNING. REMOVED AND REPSDR TRBACPCP2011001Skin · corrodedEXFOLIATION CORROSION FOUND AT PANEL AT DOOR SURROUND EDGE AT FRAME 39, STR 9 TO 10, SKIN. REMOVED CORRODED SKIN WITH CUTOUT IAW SRM 51-21-42, EO E2-53MR-272 PART A WAS SATISFACTORILY ACCOMPLISHED.SDR TRBA2011005Bulb · inoperativeEMERGENCY LIGHT (BOTTOM STEP LIGHT ) ON CABIN DOOR, INOP. REPOSITIONED MAIN DOOR EMERG LIGHT BULB AND OPT CK GOOD IAW W/C EX-33-50-00 OPT-001.SDR TRBA2011004Lamp · inoperativeEMERGENCY EXIT LIGHT ON MAIN CABIN ENTRY DOOR IS INOP. R & R EMERGENCY EXIT LIGHT BULB ON MAIN CABIN ENTRY DOOR IS IAW AMM 33-50-00. OPT GOOD.SDR COEA2011010402805Floorbeam · corrodedWO 97186 NR 100115 HEAVY CHECK / COE / LEVEL 2 CORROSION / MAJOR REPAIR: FLOORBEAM 13 FWD LWR SURFACE OF UPPER FLANGE HAS LEVEL 2 CORROSION AT 43" R OF BL 0 AROUND NUT PLATE, FOUND WHILE WORKING RT CREASE BEAM WEB LWR SURFACE. REPAIR PER ATR SRI.SDR COEA2011010401805Pressure Panel · damagedWO 101833 HEAVY CK / COE / MAJOR REPAIR: WHILE REMOVING FASTENERS ON RT SPLICE ANGLE OF WING PRESSURE DECK FR 27 STR 4, TWO HOLES WERE ELONGATED (MISDRILLED). REPAIR PER SRAS FROM ATR AND SRM.SDR TRBA2011003Light · no testCABIN DOOR EMERGENCY LIGHT WON'T TEST. R & R OF EMERGENCY GROUND ILLUMINATION FLOOD LIGHT ASSY 21WL IAW AMM JIC 33-51-24 AND W/C OPT SATISFACTORY IAW EX-335000OPT10000-001.SDR TRBA2011002Wire · damagedEMERGENCY LIGHT AT BOTTOM OF STAIRS ON MAIN CABIN DOOR INOP. REPAIRED WIRE BY DOOR UPPER STEP IAW STD PRACTICE, OPT CK GOOD IAW MM 33 50 00.SDR TRBA2011001Wire · damagedEMERGENCY LIGHT IN CABIN STAIR NOT WORKING. REPAIRED WIRE A ON PAX DOOR CONNECTOR PLUG IAW AMM 20-27-17, OPS CHECK OK.SDR TRBA2010152Bulb · inoperativeFLOOR PROXIMITY, EMERGENCY ESCAPE PATH MARKING SYS HAS MULTIPLE BULBS LIGHT THAT DO NOT ILLUMINATE. OPS TESTED EMERGENCY ESCAPE PATH LIGHT AT FLOOR IAW JIC 33-50-00 WORKING PROPERLY.SDR TRBA2010151Light · inoperativeGROUND FLOOD LIGHT ON BOTTOM STEP OF MAIN CABIN ENTRY DOOR IS INOP. OPS CHECKED FLOOD LIGHT EMERGENCY LIGHT AT MAIN CABIN DOOR BOTTOM STEP FOUND WORKING PROPERLY TESTED OK IAW JIC 33-50-00.SDR COEA2010121763803Support Beam · crackedP-F MODIFICATION BY M7 AEROSPACE IN SAT / CRACK OF PAX / CREW DOOR SURROUND / 2 EACH AFT DOOR BEAM SUPPORTS: 1 WITH A 0.50, CRACK AND THE OTHER WITH A 0.25, CRACK ALSO LOCATED IN THE RADIUS. THE PART NUMBER FOR THESE DOOR BEAM SUPPORTS ARE THE SAME P/N S 52176SDR COEA2010121762803Intercostal · crackedP-F MODIFICATION BY STC BY M7 IN SAT / CRACK OF PAX / CREW DOOR SURROUND / LOCATED FROM TOP OF DOOR, BETWEEN 6 AND 14 DOWN, AND FROM FRONT TO BACK. 1 EACH INTERCOSTAL RECEIVED WITH 1 EACH CRACK IN RADIUS AT 0.75 IN LENGTH P/N S 52176205202-01.SDR COEA2010121761803Frame · damagedATR STRUCTURAL REPAIR INSTRUCTION DO/TS-6714/10-14653 SAT P-F MODIFICATION PER STC/ MIS-DRILLED HOLES / MAJOR REPAIR OF MIS-DRILLED HOLES IN FRAME 23 WEB AT STRINGER 5A. REPAIRED IN ACCORDANCE WITH REFERENCED ATR SRI WITH CUTOUT AND LOCALIZED DOUBLER REPAIR. SDR COEA2010121760803Seat Track · corrodedWO 97861 NR 100011 COE HEAVY CK / LEVEL 2 CORROSION / MAJOR REPAIR: RT OUTBOARD SEAT TRACK HAS AREAS OF BARE METAL WITH CORROSION BETWEEN FRAMES 29 & 36. BLENDED RIGHT O/B SEAT TRACK FOUND FR 34.5 TO 36 OUT OF LIMITS. REC'D NEW SEAT TRACK AFT END FR 34.5 -36SDR TRBA2010149Socket · burnedELECTRICAL SMOKE ODOR IN CABIN. AT THIS TIME OPENED MIDDLE TO AFT OVERHEAD BINS, FOUND BURNED LIGHTSOCKET AT OVERHEAD 12AB. REMOVED LIGHT SOCKET AND DEFERRED ON MEL 33-02 AUTH NR 120088-C FIN NR303LGA. CLOSED BINS IAW MM 25-24-21. R & R CEILING LIGHT 12AB BUSDR COEA2010120959803Threshold · corrodedLEVEL 2 CORROSION / MAJOR REPAIR: AFT RT SERVICE DOOR THRESHOLD PLATE UPPER SURFACE HAS LEVEL 2 CORROSION BETWEEN FRAMES 36 & 39. REMOVED THRESHOLD PLATE, INTERCOSTALS, ETC. REMOVED CORROSION FROM THRESHOLD WEB, FOUND OUT OF LIMITS (LENGTH 4 INCH, WIDTH 3 ISDR TRBA2010148Symbol Generator · inoperativeELECTRICAL SMOKE, "EMERGENCY DECLARED" R & R NR 2 SYMBOL GENERATOR. OPS CK OK IAW JIC 34-71-82.
Back to Aerospatiale ATR 72-212