SDR TRBA2010147Engine · failedNR 1 ENGINE FAILURE DURING DESCENT WITH IMMEDIATE RELIGHT. PERFORMED SPECIAL REQUEST 288720348, ISPECTED LT ENGINE WIRING, NO DEFECTS NOTED. REMOVED AND REPLACED AFU IAW ATR 72 JIC 77-13-62 OPS CHECK NORMAL. INSPECTED AND CLEANED TORQUE SENSORS CONNECTOR, NOSDR TRBA2010146Battery Pack · inoperativeEMERGENCY LIGHTS ARE ON AT ALL TIMES IN FWD CABIN. R & R FWD EMERGENCY LIGHTS POWER SUPPLY 43WL AND POWER SUPPLY BATTERY PACK IAW JIC 33-51-21 10000 AND 33-51-21 10010. OPS TEST SATISFACTORY.SDR TRBA2010145Light · malfunctionedEMERGENCY EXIT LIGHTS REMAIN ILLUMINATED AFTER BEING TURNED OFF/ARMED. RESET SYS AND OPS CHECKED GOOD IAW AMM JIC 33-50-00 OPT 10000 ACFT, OK FOR SERVICE.SDR COEA2010112402807Skin · leakingMAJOR REPAIR: RT WING FUEL LEAK AT LOWER SKIN TO RIBS 15-16 JOINT, STRINGERS 1-2 & 6. FASTENERS REMOVED, HOLES INSPECTED AND FILLED WITH SEALANT THEN BLIND BOLTS INSTALL FOLLOWING ATR INSTRUCTIONS. SRAS DO/TS-4176/10...6141 VALIDATED AS PERMANENT REPAIR.SDR TRBA2010144Power Supply · inoperativeDURING PREFLIGHT LT FWD EXTERIOR EMERGENCY EXIT FLOOD LIGHT INOP. R & R EMERGENCY POWER SUPPLY FIN NR61WL IAW JIC 33-51-21 OPT CHECK WORKING PROPERLY.SDR TRBA2010137Insulation · out of positionDURING CLIMB AT ABOUT 5000 FT F/A REPORTED DETECTING A BURNING RUBBER ODOR AND HEAT AT HER FEET IN HER FWD JUMPSEAT. INSPECTED FWD INTERIOR OF ACFT AND FOUND HEATER SELECTED AND A INSULATION OUT POSTION CAUSING THE FUNNY ODOR, RESECURED INSULATION, OPS CHECK SDR TRBA2010136Lamp · inoperativeONE EMERGENCY EXIT LIGHT NOT WORKING IN REAR. RELAMPED WITH BULB FROM SPARE BULB KIT IAW MM 33-60-00. OPS CK GOOD.SDR TRBA2010135Wire · disconnectedEMERGENCY LT IN CABIN DOOR STEPS INOP. RECONNECTED LAMP WIRE IAW SMP 20-45-00. OPS CK GOOD.SDR 2010F00237Seat Track · corrodedUPON REMOVAL OF SEAT TRACK, FOUND PITTING CORROSION ON FLOORBEAM MATING SURFACE AT FLOORBEAM 23, FABRICATED REPLACEMENT FLOORBEAM SEGMENT FROM NTA 44770 7075-T-6511, PO 2059P. INSTALLED NEW FLOORBEAM & REPAIR SPLICES IAW SRM 53-00-00 435, REV 77.SDR 2010F00236Crease Beam · corrodedRH CREASE BEAM WEB FR40-41 IS CORRODED. WEB ASSY WAS REMOVED TO FOM ON NR 100070 W/O 97183. FABRICATED WEB WAS INSTALLED ON NR 100070 W/O 97183.SDR 2010F00235Stringer · corrodedJOINT STRINGER ON STR 19R AT FR23, SUSPECTED OUT OF LIMITS FOR CORROSION. REMOVED CORROSION REFERENCING SRM 51-21-42, REV 77. FOUND MATERIAL LOSS TO BE BEYOND SRM LIMITS IAW SRM 51-10-10, REV 77. SRM 53-51-26, FIG 101, ITEM 30, REV 77 AND SRM 51-31-60, FIG 4SDR 2010F00234Stringer · corroded(COER) FLIGHT DECK, STR 21R END TIE JUST AFT OF FRAME 12 HAS SURFACE CORROSION. (LEVEL II) REMOVED CORROSION IAW SRM 51-21-42, REV 77. FOUND TO BE OUT OF LIMITS IAW SRM 51-10-10, REV 77. REMOVED STRINGER END TIE IAW SRM 51-25-01, REV 77. INSTALLED NEW STR SDR 2010F00233Stringer · corroded(COER) FLIGHT DECK, STRINGER 21L JUST AFT OF FRAME 12 HAS SURFACE CORROSION. (LEVEL II) REMOVED RIVETS TO FOM CORROSION REMOVAL IAW SRM 51-25-01, REV 77. REMOVED CORROSION IAW SRM 51-21-42, REV 77. FOUND TO BE OUT OF LIMITS IAW SRM 51-10-10, REV 77. REMOVEDSDR 2010F00232Stringer · corroded(COER) FLT DECK, FRAME 12 FWD, AFT SIDE FROM STRINGER 20L-20R HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-42, REV 77. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-11-00, FIG 301 & 53-11-40, FIG 112, REV 77. ALL PARTS INSTALLED IAW SRM 51-25-01, 51-2SDR 2010F00231Spar · corrodedLEFT WING FRONT SPAR LOWER FLANGE AT RIB 31 HAS SMALL AREA OF DELAMINATED. REPAIRED DAMAGE IAW STRUCTURAL REPAIR INSTRUCTION DO/TS-3386/10-13712 ISSUE A DATED JUNE 28, 2010. OK TO PAINT. RESTORED TOPCOAT IAW SRM 51-21-27, PP 1-25, REV 77 FEB 01/10. SRI DO/TSDR COEA2010110303807Connector · mislocatedP TO F CONVERSION AT SAT: DURING MODIFICATION OF AFT PAX DOOR PER DWG 72-8100, THE CONNECTOR (FOR CARGO DOOR UNLOCK) WAS MISALLOCATED. PER ATR SRI DO/TS-5140/10-14251 AND SRAS DO/TS-5140/10...6062 FABRICATED AND INSTALLED REPAIR DOUBLER.SDR TRBA2010133Connector · dirtyLT MAIN GEAR WOULD NOT RETRACT AFTER T/O STAYED DOWN AND LOCKED PLUS RED UNLOCK WAS ON, (DECLARED EMERGENCY) PLACED ON MEL 32-03 AUTH NR110015DMC. CLEANED CORRODED CONNECTOR AT LT MLG WOW PROX SWITCHES 50GB & 51GB, RESECURED WIRE BUNDLE TO SELECTOR VALVE 13GA,SDR COEA2010102958803Threshold · corrodedCOE HEAVY CHECK / LEVEL 2 CORROSION: LT AFT PAX/CREW DOOR THRESHOLD PLATE HAS AREAS OF CORROSION ON TOP & BOTTOM SURFACES. REMOVED CORROSION IAW ATR72 SRM 51-21-42, REVISION 78 AND ATR72 SRM 51-21-58 REVISION 78. FOUND TO BE OUT OF LIMITS. REPLACED THRESHOSDR TRBA2010130Fire Detector · false activationWHEN WAITING TO PARK ACFT, NR 1 ENGINE FIRE. DISCHARGED AGENT 1 AND FIRE WENT OUT, WIND WAS 110 AT 3 KNOTS. "DECLARED EMERGENCY" R & R FIRE BOTTLE IAW JIC 26-21-71-RAI 10000 AND CARTRIDGE IAW JC EX-262172-RAI-10000. OPS CHECK GOOD. CLEANED AND INSPECTED ESDR COEA2010102866803Floorbeam · damagedHEAVY CHECK COE / MAJOR REPAIR: FLOORBEAM 38 MISDRILLED: FABRICATED AND INSTALLED REPLACEMENT FLOORBEAM PER ATR STRUCTURAL REPAIR MANUAL.SDR COEA2010102865803Skin Panel · damagedHEAVY CHECK COE / MAJOR REPAIR: ACCIDENTAL DAMAGE INDUCED AT O/B FASTENER ROWS OF ADF ANTENNA REPAIR DOUBLER BL 0 FR 28D-28C CROWN SKIN. FABRICATED AND INSTALLED DOUBLER PER ATR STRUCTURAL REPAIR INSTRUCTIONS.SDR COEA2010102657803Crease Beam · corrodedCOE HEAVY CHECK/ LEVEL 2 CORROSION: RT CREASE BEAM WEB BETWEEN FRAMES 10 & 11 HAVE LEVEL 2 CORROSION ON LOWER SURFACE (LENGHT .75, WIDTH .6, DEPTH .007") REMOVED CORROSION FROM UPPER AND LOWER SURFACES OF CREASE BEAM WEB. FOUND WEB TO BE OUT OF LIMITS. REMSDR COEA2010102656803Skin · corrodedCOE HEAVY CHECK / LEVEL 2 CORROSION: EXTERIOR FUSELAGE, LOWER RADIO ALTIMETER ANTENNA NUMBER 2 MOUNTING SKIN SURFACE HAS LEVEL 2 CORROSION BEYOND ALLOWABLE LIMITS. (LENGTH .75, WIDTH .6 AND DEPTH.033") REMOVED PLATE, RECEIVED NEW DOUBLER, INSTALLED NEW DOUBSDR TRBA2010132Bpcu · failedTOTAL ACFT ELECTRICAL FAILURE (BOTH BUSES + INVERTERS) EMERGENCY DECLARED. R & R DC BPCU IAW AMM JIC 24-46-83-RAI-10000 AND JIC 72-00-00-ERU-10000. R & R ACW BUS POWER CONTROL UNIT IAW JIC 24-41-83-RAI-10000-001. OPS CHECK GOOD NO ELECTRICAL DISCREPANCIES NOTESDR TRBA2010131Fan · failedEXHAUST FAN FAULTED WHILE TAXIING TO RUNAWAY. BURNING ODOR IN COCKPIT. AT THIS TIME EXHAUST EXTRACT FAN DEFERRED IAW MEL 21-6 AUTH NR100180D-C. MEL CLEARED ON 1-25-10 AT SJU: R & R AIR EXTRACTION FAN IAW JIC 21-23-21. OPS TEST FOUND OK IAW JIC 21-23-00-OPT-1SDR COEA2010102064803Skin · corrodedHEAVY CK / COE /MAJOR REPAIR / LEVEL 2 CORROSION: EXTERIOR FUSELAGE UPPER VHF/2 ANTENNA MOUNTING AREA HAS SURFACE CORROSION (LENGTH 1.7", WIDTH 1", DEPTH .022"). FABRICATED AND INSTALLED VHF/2 ANTENNA DOUBLER. (NOTE: AIRCRAFT NOT ON EA CERTIFICATE AT THIS TSDR COEA2010102001816Computer · faultyANC FLIGHT 8663: AIR TURNBACK AND ENGINE SHUT DOWN: ON CLIMBOUT NP DROPPED 20-30 PERCENT W/POPPING NOISE & A/C SHUTTER ACCOMPANIED BY MFC 1B FAULT. CREW SHUT DOWN THE NUMBER ONE ENGINE; DECLARED AN EMERGENCY. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE SDR COEA2010101955803Skin Panel · damagedCOE HEAVY CHECK / MAJOR REPAIR: UPON REMOVAL OF FR36 FOUND TOOLING DAMAGE BEYOND SRM LIMITS UNDER FLANGE AT BLO. CUT OUT DAMAGED SKIN. FABRICATED AND INSTALLED SKIN DOUBLER AND SHIM IAW ATR72 SRM.SDR COEA2010101954803Crease Beam · corrodedCOE HEAVY CHECK / LEVEL 2 CORROSION / MAJOR REPAIR: RT CREASE BEAM WEB BETWEEN FRAMES 12 & 13 HAS AREAS OF LEVEL 2 CORROSION (LENGTH 3", WIDTH 2", DEPTH .011") ON TOP AND BOTTOM SURFACES. REMOVED CREASE BEAM WEB, FABRICATED AND INSTALL REPLACEMENT CREASE BEASDR TRBA2010126Acm · odorDURING CLIMBOUT NR 1 PACK EMITTED ODOR, THEN DUCT TEMP WENT TO 45. R & R NR1 PACK ACM OPS CHECKS GOOD IAW JIC 21-51-52 MEL RESTORED.SDR COEA2010101553803Stringer Splice · corrodedCOE HEAVY CHECK / LEVEL 2 CORROSION: STRINGER 20R JOINT SPLCE BETWEEN FRAMES 12 & 13 HAS LEVEL 2 CORROSION. FOUND TO BE OUT OF LIMITS LENGTH .7", WIDTH .4" AND DEPTH .010". REMOVED AND REPLACED JOINT STRINGER AND STRINGER CLIP IAW ATR SRM.SDR COEA2010101552803Splice · corrodedCOE HEAVY CK / LEVEL 2 CORROSION: RT INBOARD CREASE BEAM CHORD ANGLE SPLICE AT FRAME 23 HAS LEVEL 2 CORROSION. FOUND TO BE OUT OF LIMITS: LENGTH .5", WIDTH .5 INCH AND DEPTH .020". REMOVED AND REPLACED RT CHORD SPLICE IAW ATR SRM.SDR COEA2010101551803Splice · corrodedCOE HEAVY CK / LEVEL 2 CORROSION: LT INBOARD CREASE BEAM CHORD ANGLE SPLICE AT FRAME 23 HAS LEVEL 2 CORROSION. FOUND TO BE OUT OF LIMITS: LENGTH 1.7, WIDTH .8 AND DEPTH .028". REMOVED AND REPLACED CHORD SPLICE IAW ATR SRM.SDR TRBA2010122Lamp · inoperativeEMERGENCY LIGHT ON STAIRS INOP. R & R EMERGENCY LIGHT ASSY IAW 33-51-24. OPS CHECK GOOD IAW 33-50-00.SDR COEA2010101550803Support · damagedCOE HEAVY CK / MAJOR REPAIR: AIRCRAFT INTERIOR SUPPORT STRUCTURE AFT OF FR23D AT STR 5A RT HAS FASTENER DAMAGE. BLEND EDGE IAW STRUCTURE REPAIR INSTRUCTIONS FROM ATR AND LEAVE AS IS. REFERENCE SRM 53-57-70 FIG 109 ITEMS 15 & 30.SDR COEA2010Stringer · corrodedCOE HEAVY CK/ LEVEL 2 CORROSION / MAJOR REPAIR: STRINGER 17R HAS CORROSION AT 20 PERCENT MATERIAL LOSS IN A LOCALIZED LOCATION BETWEEN FRAMES 38 & 39. BLEND OUT IAW STRUCTURAL REPAIR INSTRUCTION FROM ATR AND LEAVE AS IS.SDR TRBA2010123Hose · looseBURNING ODOR IN BOTH COCKPIT AND CABIN AS ACFT PULLED INTO RAMP. ODOR DISSAPATED WHEN AC PACKS TURNED OFF. TIGHTENED LOOSE HOSE AT R/S HEAT EXCH. IAW JIC 21-51-51 AND UNCLOGGED L/S ACM WATER SPRAY NOZZLE IAW JIC 21-51-91. PERFORMED ENGINES GRD RUN IAW JIC 1SDR TRBA2010120Wire · damagedPASSENGER STAIR EMERGENCY LIGHT BURNED OUT. REPAIRED WIRE AT MAIN DOOR CONNECTOR IAW STD PRACTICE ,OPT CK GOOD IAW MM 52 70 00.SDR TRBA2010119Brake · wornBRAKES ARE SPONGY. PEDALS CAN BE PRESSED ALL THE WAY TO THE STOPS. R & R NR 2 AND 4 BRAKE ASSY IAW JIC 32-42-55-RAI-10000-005.SDR TRBA2010117Contactor · burnedDC SERVICE UTILITY BUSS SHED DURING FLIGHT. DOES NOT RESET. SMELLED BURNING RELAY IN THE COCKPIT. REMOVED AND REPLACED DC BUSS TIE CONTACTOR 16PU IAW JIC 24-00-00 RAI 10040003SDR TRBA2010116Warning Light · illuminatedUNSAFE LANDING GEAR ON THE LT MAIN GEAR ON BOTH PANEL. FOLLOW THE AOE MANUAL CHECK LIST AND RETURNED TO DEPARTURE. (DECLARED EMERGENCY) REMOVED WATER AND CLEANED LT MLG PROXIMITY SWITCHES (WOW) AND PERFORMED NORMAL EXTENSION AND RETRACTION FUNCTIONAL TEST IAWSDR COEA2010100548803Fitting · damagedCOE HEAVY CHECK/MAJOR REPAIR: FOUND INBOARD CHORD (BATHTUB FITTING) AT FR 36 TO HAVE TOOLING DAMAGE & CORROSION. TOOLING DAMAGE BLENDED OUT IAW ATR72 SRM 51-21-42.SDR COEA2010100547803Fitting · damagedCOE HEAVY CHECK / MAJOR REPAIR: LT INBOARD CREASE BEAM CHORD BATH TUB FITTING AT FWD SIDE OF FRAME 39 HAS AREA OF BARE METAL. TOOLING DAMAGE BLENDED OUT IAW SRM 51-24-42.SDR TRBA2010115None · noneLIGHTENING STRUCK THE ACFT IN FLIGHT, AS A RESULT THE PRESSURIZATION CABIN ALTITUDE RATE STARTED CLIMBING. (EMERGENCY DECLARED) PERFORMED DETAILED VISUAL INSP AFTER LIGHTENING STRIKE IAW WORK CARD EX-055113-DVI-10000-003 AND PLACED THE AUTO PRESSURIZATION SYS SDR COEA2010092846803Stringer · corrodedHEAVY CK / LEVEL 2 CORROSION / MAJOR REPAIR: STRINGER 15R FOUND TO HAVE EXFOLIATION LEVEL 2 CORROSION ON LEG OF STR COMMON TO AC SKIN BETWEEN FR 35 TO 37 (LENGTH 3', WIDTH .600", DEPTH .023"). REPAIR PER ATR72 SRM 53-00-00 FIG 428 REFERENCE SRM 53-61-24 FIG SDR TRBA2010112Lens · damagedEMERGENCY LIGHT LENS COVER SEPARATED FROM HOUSING. RESECURED LENS ON EMERGENCY LIGHT ASSY AS REQUIRED. OPS CHECKED IAW ATR JIC 33-50-00, OPS CHECK GOOD.SDR TRBA2010113Fan · failedSTRONG SMELL OF ELECTRICAL SMOKE BY NR 1, NR 2 CARGOS NO VISUAL NO ALARMS. AFTER ENGINE SHUTDOWN. R & R EXTRACTION FAN IAW JIC 21-23-21 RAI 10000, OPS CHECK GOOD.SDR COEA2010092445803Stringer · corrodedHEAVY CHECK / LEVEL 2 CORROSION: FOUND CORROSION ON STR 16R AT FR36 WHILE WORKING FRAME 36. REPAIR STRINGER SPLICE IAW ATR72 SRM 53-61-24 FIG 101 ITEM 20.SDR COEA2010092444803Crease Beam · corrodedHEAVY CHECK/ LEVEL 2 CORROSION/MINOR REPAIR: RT INBOARD CREASE BEAM CHORD ANGLE HAS LEVEL 2 SURFACE CORROSION BETWEEN FRAMES 8 & 13. REMOVE AND REPLACE ANGLE INBOARD CHORD WITH NEW OEM PART PER ATR72 SRM.SDR COEA2010092343803Stringer · corrodedHEAVY CHECK/ LEVEL 2 CORROSION/MINOR REPAIR: STRINGER 17R HAS LEVEL 2 CORROSION BETWEEN FRAMES 35 AND 40 TOP SURFACE 0013" DEPTH. REMOVE AND REPLACE STR 17R OUTER CHORD WITH OEM PART PER SRM. CORRODED AREA BLEND-OUT FOLLOWING ATR REPAIR INSTRUCTIONS DO/TS-5
Back to Aerospatiale ATR 72-212