What was found
(COER) FLT DECK, FRAME 12 FWD, AFT SIDE FROM STRINGER 20L-20R HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-42, REV 77. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-11-00, FIG 301 & 53-11-40, FIG 112, REV 77. ALL PARTS INSTALLED IAW SRM 51-25-01, 51-25-02, 51-25-03, 51-25-04 AND 53-11-40, REV 77. APPLIED ALODINE PRIMER AND PAINT TO OUTER SKIN AS REQUIRED IAW SRM 51-21-17 AND 51-21-27 REV 77.