SDR F3LA2011110900688Light · malfunctionedEMERGENCY EXIT LIGHTS AND ESCAPE PATH LIGHTS REMAINED ON DURING FLIGHT WITH SWITCH IN "NORM" POSITION- AND FAP AMBER NOTE "CHECK PAX RELATED FUNCTIONS" TROUBLESHOT REF TSM 33-51-00-810-881. CHECKED EPSU BATTERIES FOR CONDITION AND SECURITY. OPS TEST NORMAL IAWSDR F3LA2011101800685Solenoid Valve · failedA/C PACK 2 FAILED IN FLIGHT. PACK 1 ON MEL SO PACK 2 FAIL CAUSED A CABIN DEPRESSURIZATION AND 02 MASK TO DEPLOY. R & R PRESSURE REGULATOR VALVE SOLENOID 10HA2 IAW AMM 36-11-55, PB 401. OP'S AND LEAK CHECKED GOOD.SDR F3LA2011101300684Light · inoperativeEMERGENCY LIGHT AT SEATS ROW 11 ABC INOPERATIVE. R & R LIGHT. OPS CHECKED GOOD. REF AMM 33-51-00-710-001.SDR F3LA2011100700682Line · rupturedAIRCRAFT LOST PARTIAL GREEN SYS HYD FLUID IN FLIGHT. UPON ARRIVAL, ON-CALL MX IDENTIFIED A HYD LINE IN THE PYLON RUPTURED. TUBE WAS CHANGED. LEAK CHECK GOOD.SDR F3LA2011092600680Hose · rupturedON DEPARTURE, GREEN SYS FAILURE (FLUID LOSS) R & R LT MLG SWIVEL JOINT REF AMM 32-31-38-000, PB401. R & R FLEX HOSE ASSY REF AMM 32-31-39-000, PB 401. OPS LEAK CHECKED NORMAL, SERVICED GREEN HYD SYS 12-12-29-611-001, OK.SDR F3LA2011091900679Floor Support · corrodedC-CHECK: NON ROUTINE 38895; MAIN CABIN FR68 LT AFT DOOR SEAL BEAM HAS CORROSION. REPAIRED LT AFT DOOR SEAL BY REMOVING DAMAGE AND INSTALLING A REPAIR ANGLE IAW SRM 53-41-14, PB 201.SDR F3LA2011091900678Floor Support · corrodedC-CHECK: NON ROUTINE 38894; MAIN CABIN FLOORBEAM FROM FR66 TO FR68 HAS CORROSION. REPLACED CABIN FLOORBEAM FR66 TO FR68 IAW SRM 51-42-11.SDR F3LA2011091600677Floorbeam · corrodedC-CHECK: MAIN CABIN FLOORBEAM FR66 Y254 IS CORRODED. REPLACED FLOORBEAM IAW SRM 51-42-11.SDR F3LA2011091600676Floorbeam · corrodedDURING C CHECK, MAIN CABIN FLOORBEAM FR68 -Y1292 FOUND CORRODED. REPLACED FLOORBEAM IAW SRM 51-42-11.SDR F3LA2011091600674Floorbeam · corrodedC-CHECK: MAIN CABIN FLOORBEAM FR68- Y1292 HAS CORROSION. REPLACED MAIN CABIN FLOORBEAM FR68-Y1292 IAW SRM 51-42-11, PARA 5A AND SRM 51 -44-11 TABLE 2.SDR F3LA2011091600673Floorbeam · corrodedC-CHECK, MAIN CABIN FLOORBEAM FR68- V765 HAS CORROSION. REPLACED MAIN CABIN FLOORBEAM FR68-V765 IAW SRM 51 -42-11 AND SRM 51 -44-11.SDR F3LA2011091600675Battery Pack · failedDURING MX, PERFORMED OPS CHECK OF THE EMERGENCY LIGHTING, RECEIVED A FAILURE MESSAGE OF EPSU BATTERY PERFORMED TSM 33-51-00-810-801 AND FOUND WEAK BATTERY. R & R BATTERY IAW AMM 33-51-00-710-006, AMM 33-51-38-000-002 AND AMM 33-51-38-400-002. OPS CHECKED GOOSDR F3LA2011091300671Relay · inoperativeEMERGENCY EXIT LIGHTS FLICKERING ON TAKEOFF ROLL. R & R RELAY (8WL) REF ASM 33-51-00. OPS TEST OF THE EMERGENCY LIGHTS TEST GOOD REF AMM 33-51-00-710-001.SDR F3LA2011091300670Lamp · burned outOVERWING EMERGENCY LIGHT 60WL HAD AFT BULB INOPERATIVE. RELAMPED EMERGENCY LIGHT 60WL IAW AMM 33-51-15 PB 401. OPS CHECKED GOOD.SDR F3LA2011091400672Battery · failedRT EMERGENCY EXIT LIGHTING POWER SUPPLY 12 WL BATTERY FAILED TEST. R & R BATTERY, OPS CHECKED OK IAW AMM 33-51-38-000-001 AND 33-51-38-400-001.SDR F3LA2011090800669Battery · defectiveDURING HEAVY CHECK, PERFORMED EMERGENCY LIGHT OPS CHECK ON PTP PANEL. TEST FAILED WITH MESSAGE "EPSU BATTERY EMER L". LOCATED OVERWING EPSU ON LT SIDE AND PERFORMED TEST ON INDIVIDUAL UNIT. TEST FAILED WITH "BATT FAULT" LIGHT ILLUMINATED. R & R EPSU BATTERYSDR F3LA2011090800668O-Ring · deterioratedHYD Y RESERVOIR LOW LEVEL DURING FLIGHT. SUBSEQUENT Y SYS FAILURE INDICATIONS. REMOVED AND INSTALLED SERVICEABLE O-RING ON REDUCER ON PTU MANIFOLD. PERFORMED OPS CK AND LEAK CK. NO FAULTS OR LEAKS NOTED. REF AMM 29-13-15 PB 401, PG 5, STEP 4 A (2) (E) AND (F).SDR F3LA2011090800667Battery · failedDURING TEST EPSU BATTERY FORWARD LT FAILED. REPLACED LT FORWARD EMERGENCY EPSU BATTERY PACK IAW AMM 33-51-38-400-002, CHECKS NORMAL.SDR F3LA2011083100666Power Supply · failedPATHWAY EMERGENCY LIGHTS ON & OFF INTERMITTENTLY, EMERGENCY EXIT LIGHT ACFT LT OVERWING EXIT ON THROUGHOUT NIGHT. R & R EPSU EMERGENCY POWER SUPPLY UNIT 11WL WITH SERVICEABLE PART IAW AMM 33-51-38 PB 401, OPS CHECK GOOD.SDR F3LA2011080300662Connector · misinstalledEXTERIOR OVERWING EMERGENCY LIGHTS INOP". "FOUND BOTH EXTERNAL OVERWING EMERGENCY LIGHTS ON THE RT SIDE WERE NOT CONNECTED TO ACFT WIRING. RECONNECTED CONNECTORS TO LIGHT ASSY. SYS OPS CHECKS NORMAL REF AMM 33-S1-1 S PB401. NOTE: THERE WERE NO DEFECTIVE PARSDR F3LA2011071200660Support Fitting · corrodedC-CHECK: NON ROUTINE NR 36085; RT WING MLG SUPPORT RIB 5 FORWARD LUG INNER BORE HAS CORROSION. REFERENCES EO AO-57EO-20243. REMOVED CORROSION BY OVER SIZING BORE TO 3.7995" AND INSTALL NEW BUSHINGS IAW SRM 57-26-13, PARA 5C, FIG 203 AND 204.SDR F3LA2011063000659Thrust Reverser · damagedC-CHECK: NON ROUTINE NR 22652; NR 2 ENGINE HAS LIGHTNING STRIKE AT THE 4 O'CLOCK POSITION. REPAIRED NR 2 ENGINE OTBD THRUST REVERSER AT THE 4 O'CLOCK POSITION IAW CMM 54-30-00, REPAIR NR 13.SDR F3LA2011061400656Door · openLP 540215: AIR TURN BACK, FWD CARGO DOOR OPEN AFTER TAKEOFF "OVERWEIGHT LANDING". PLACED THE CARGO DOOR ON MEL 52-70-01H MDDR 1083274 AND PERFORMED INSPECTION RTS 1715 MCI LOCAL TIME.SDR F3LA2011052300653Support Fitting · corrodedC-CHECK: RT WING MLG SUPPORT RIB 5 FWD LUG INNER BORE HAS CORROSION. IAW EO A0-57EO-20243. REMOVED CORROSION BY OVER SIZING BORE TO 3.8772" AND INSTALLING NEW BUSHINGS. IAW SRM 57-26-13, PAR 5C AND FIG 203 AND 204.SDR F3LA2011052300652Pump · leakingPILOT REPORT YELLOW HYDRAULIC LOW RESERVOIR LEVEL. REMOVED AND REPLACED ENGINED NR2 HYDRAULIC PUMP DRIVER IAW AMM 29-13-51, PB 401, OPS CHECKS GOOD. FOUND SEVERAL LEAK YELLOW SYSTEM LINE TO PRESSURE SWITCH. REMOVED AND REPLACED LINE IAW AMM 28-23-11 LEAKED CHSDR F3LA2011051900646Floorbeam · corrodedC-CHECK: NON ROUTINE NR 1287; CORROSION ON UPPER SURFACE OF RT AFT ENTRY AREA, FLOORBEAM AT FR 68, RBL 48, FOUND TO BE OUT OF LIMITS. R & R FLOORBEAM AT FR 68, RBL 48 IAW SRM 51-24-00, PARA 6.SDR F3LA2011501900645Floor Panel · delaminatedC-CHECK: CABIN FLOOR PANEL 241JF HAS DELAMINATION IN SEVERAL AREAS AND FOUND TO BE OUT OF REPAIRABLE LIMITS. R & R FLOOR PANEL 241JF IAW SRM 53-02-00, PB 101.SDR F3LA201151900644Floor Support · corrodedC-CHECK: CORROSION ON UPPER SURFACE OF RT AFT ENTRY AREA, FLOORBEAM AT FR 68, RBL 30. R & R FLOORBEAM AT FR 66-70, RBL 30 IAW SRM 51-74-00.SDR F3LA201151900643Shear Plate · crackedC-CHECK: NON ROUTINE NR1262; LT AFT LATERAL SHEAR PLATE IS CRACKED, FR69, STR 24. REPLACED LT AFT LATERAL SHEAR PLATE WITH NEW CONFIGURATION IAW EO A0-53EO-31434 AND IAW SRM 51-42-11-1- A, B, C.SDR F3LA201151900642Floorboard · damagedC- CHECK: NON ROUTINE NR1329: COCKPIT FLOORBOARD, 211GF SURFACE IS DAMAGED. FOUND DAMAGE TO FLOORBOARD 211GF BEYOND REPAIRABLE LIMITS. REPLACED FLOORBOARD IAW SRM 53-12-00, DIAGRAM 101.SDR F3LA2011051900642Floorboard · damagedC-CHECK: COCKPIT FLOORBOARD, 211GF SURFACE IS DAMAGED. FOUND DAMAGE TO FLOORBOARD, 211GF BEYOND REPAIRABLE LIMITS. REPLACED FLOORBOARD IAW SRM 53-12-00 IAW DIAGRAM 101.SDR F3LA2011050300639Electrical Box · faultyPILOT REPORT, ON TAKEOFF AMBER NOSE WHEEL STEERING DISCONNECT ILLUMINATED. NO ASSOCIATED ECAM. PILOT DECLARED EMERGENCY BEFORE LANDING. NO FUTHER ABNORMALITIES. TROUBLESHOT IAW TSM 32-51-00-810-833. R & R NWS ELECTRICAL BOX OPS CHECKED GOOD IAW AMM 32-51-1SDR F3LA2011041300636Battery · dischargedC-CHECK: NON ROUTINE NR 61090; EMERGENCY LIGHT EPSU (12WL) BATTERY FAILS SYS TEST. R & R EMERGENCY LIGHT BATTERY 12WL IAW AMM 33-51-38, PB 401. PERFOMED OPS CHECK IAW AMM 33-51-710-001. OPS TEST GOOD.SDR F3LA2011041300635Battery · dischargedC-CHECK: NON ROUTINE NR 61089; EMERGENCY LIGHT EPSU (11WL) BATTERY FAILS SYS TEST. R & R EMERGENCY LIGHT BATTERY 11WL IAW AMM 33-51-38 PB 401. PERFOMED OPS CHECK IAW AMM 33-51-710-001. OPS TEST GOOD.SDR F3LA2011040500631Floor Support · corrodedC-CHECK: NON ROTINE 36933; CABIN FR66, Y-765 FWD OF SPLICE, FLOOR SUPPORT HAS CORROSION AT FLOOR PANEL. REPLACED CABIN FLOOR SUPPORT FR66, Y-765 IAW SRM 51-42-11 PARA 5, PARA 6.D, PARA 5.A. AND B.SDR F3LA2011040500630Floor Support · corrodedC-CHECK: NON ROUTINE NR 36931; CABIN FR66 Y-1292 FWD OF SPLICE FLOOR SUPPORT HAS CORROSION. REPLACED FWD FLOOR SUPPORT IN MAIN CABIN AT FR66 Y-1292 IAW SRM 51-42-11 PARA 5, PARA 6A.(3), PARA 7.A.(6)(7).SDR F3LA2011040500629Floorbeam · corrodedC-CHECK: NON ROUTINE NR 36930; CABIN FR66, Y-765 FWD OF SPLICE HAS CORROSION AT FLOOR PANEL ON FLOOR SUPPORT. REPLACED CABIN FLOOR SUPPORT FR66, Y-765 IAW A319 SRM 51-42-11, PARA 5 AND 6.D AND PARA 5A. AND B.SDR F3LA2011040500628Floor Support · corrodedC-CHECK: NON ROUTINE 36929; CABIN FRAME 68 Y-765, FLOOR SUPPORT HAS SURFACE CORROSION. R & R FLOOR IAW SRM 51-42-11, PARA 5 AND 6.B, PARA 7.B, SRM 51-44-11, PARA 2.A. AND B.SDR F3LA2011040500627Floor Support · corrodedC-CHECK: NON ROUTINE NR 36907; CABIN FR66, Y-1292 AFT OF SPLICE FLOOR SUPPORT HAS CORROSION. REPLACED AFT FLOOR SUPPORT IAW SRM 51-42-11, PARA 5, PARA 6.A.(3) AND PARA 7A.(6)(7).SDR F3LA2011040500626Floor Support · corrodedC-CHECK: NON ROUTINE 36906; CABIN FR68 - FR66 Y-1292 FLOOR SUPPORT HAS CORROSION IN NUMEROUS AREAS. REPLACED FLOOR SUPPORT, MAIN CABIN AT FR68 - FR66 Y-1292 IAW SRM 51-42-11, PARA 5, PARA 6.A.(3), PARA 7.A(6)(7).SDR F3LA2011040500625Floor Support · corrodedNON-ROUTINE 36905; CABIN FR68 Y-1292 AFT OF SPLICE FLOOR SUPPORT HAS CORROSION. REPLACED AFT FLOOR SUPPORT IN MAIN CABIN AT FR68 Y-1292 IAW SRM 51-42-11 PARA 5, PARA 6.A.(3), PARA 7 A.(6)(7).SDR F3LA2011040500624Sill · corrodedNON ROUTINE NR 36903; CABIN FR68 AT RT AT DOOR SILL BEAM HAS CORROSION. REPAIRED SILL BEAM IAW SRM 53-41-14. REPAIR PRINCIPLE K.SDR F3LA2011040500623Plate · corrodedC-CHECK: NON ROUTINE NR 36902; FRAME 70 RT INTERNAL SHEAR PLATE HAS CORROSION. R & R SHEAR PLATE IAW SRM 51-42-11, FIG 8, 51-44-11 PARA 6A (1), 7A(1) AND PARA 7, FIG 12, 51-21-11 PARA 4 (A)-(D), 51-75-12 AND 51-23-11.SDR F3LA2011040500622Floor Support · corrodedC-CHECK: NON ROUTINE NR 36890; CABIN FR68 AT L2 DOOR OTBD FLOOR SUPPORT HAS CORROSION. REPAIRED SILL BEAM IAW SRM 53-41-14, FIG 201, REPAIR PRINCIPLE K.SDR F3LA2011040500621Floor Support · corrodedC-CHECK: NON ROUTINE NR 36889; CABIN FR68-FR66, Y1292 FWD OF SPLICE FLOOR SUPPORT HAS CORROSION. REPLACED FWD FLOOR SUPPORT IN MAIN CABIN AT FR68-FR666, Y1292 IAW SRM 51-42-11, PARA 5, PARA 6.A.(3), PARA 7. A.(6)(7).SDR F3LA2011040500620Skin · dentedC-CHECK: NON ROUTINE NR 36804; FUSELAGE UNDER FWD CARGO DOOR FRAME 26, BETWEEN STR 43 RT AND 43 LT HAS A DENT. REPAIR SKIN DENT REF SRM 53-21-11, PARA 5.K, FIG 214 REPAIR CATEGORY B.SDR F3LA2011032100617Windshield · crackedF/O WINDSHIELD CRACKED FOLLOWING ANTI-ICE RT WINDSHIELD ECAM. R & R THE F/O WINDSHIELD WITH SERVICEABLE WINSHIELD REF AMM 56-11-11-400-000-001.SDR F3LA2011032100616Servo · slowON ROTATION ACFT ROLLS RT REGARDLESS OF WIND. PERFORMED FLT CONTROL MOVEMENT CHECKS FOUNFD LT ELEVATOR SERVO SLOW TO REACT. REF LP 596444, ITEM 1, R & R SERVO CONTROL ELEVATOR LT GREEN HYD REF AMM 27-34-51-400-001 AND 27-34-51-0000.001, OPS CHECK NORMAL.SDR F3LA2011031500615Battery Pack · failedEPSU BATTERY 13WL FAILED OPS TEST IAW REPLACED BATTERY PACK 13WL IAW AMM 33-51-38-400-002.SDR F3LA2011031500614Hinge Fitting · corrodedA/C C-CHECK: NON ROUTINE; FWD AIRFRAME HINGE FITTING FOR LT MAIN GEAR DOOR, FWD LUG FACE OF FITTING, HAS WEAR .013" TO .018" DEEP. CAUSED BY BOLT ROTATING. SPOT FACED FWD LUG BOLT HOLE FACE AND INSTALLED BUSHING. MILLED BUSHING TO LUG THICKNESS. FABRICATE
Back to Airbus A319-111