What was found
EXTRACT FAULT DISPLAYED ON UPPER ECAM SCREEN. VENT MILD FUMES AND FAULT LIGHT. PLACED IN/OVRD. FUMES CLEARED RAPIDLY. REMOVED AND REPLACED AVIONICS EXHAUST FAN AT LOCATION 18HQ, REF AMM 21-26-51-400-001A. OPS CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXTRACT FAULT DISPLAYED ON UPPER ECAM SCREEN. VENT MILD FUMES AND FAULT LIGHT. PLACED IN/OVRD. FUMES CLEARED RAPIDLY. REMOVED AND REPLACED AVIONICS EXHAUST FAN AT LOCATION 18HQ, REF AMM 21-26-51-400-001A. OPS CHECKS GOOD.